SALIX-HNE-MIB :: hneSysSyncRevertiveSwitch

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SALIX-HNE-MIB › hneSysSyncRevertiveSwitch

hneSysSyncRevertiveSwitch

Module: SALIX-HNE-MIB

OID (symbolic): SALIX-HNE-MIB::hneSysSyncRevertiveSwitch

OID (numeric): 1.3.6.1.4.1.2158.3.1.1.1.1.2.4

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Indication of whether or not the active reference should revert to primary if that reference becomes available after a failure is cleared.

true(1) - reference switching is revertive false(2) - reference switching is non-revertive

What is hneSysSyncRevertiveSwitch?

Read-write boolean controlling whether the active timing reference automatically switches back to primary once it becomes healthy again after a failure. Enable revertive switching when the primary reference is known to be the higher-quality source and you always want it preferred once restored.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2158.3.1.1.1.1.2.4
snmpwalk -v2c -c public <target> SALIX-HNE-MIB::hneSysSyncRevertiveSwitch

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2158.3.1.1.1.1.2.4.1
snmpget -v2c -c public <target> SALIX-HNE-MIB::hneSysSyncRevertiveSwitch.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2158.3.1.1.1.1.2.4.1 s <value>

Start monitoring SALIX Technologies network/telecom access equipment (Host Network Element identification/config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SALIX-HNE-MIB::hneSysSyncRevertiveSwitch OID value, configure state conditions and alerts, and monitor any SALIX Technologies network/telecom access equipment (Host Network Element identification/config) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2158salixTechnologiesSALIX-MIB
1.3.6.1.4.1.2158.3salixProductsSALIX-MIB
1.3.6.1.4.1.2158.3.1hybridSwitchSALIX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2158.3.1.1hneMIBSALIX-HNE-MIB
1.3.6.1.4.1.2158.3.1.1.1hneMIBObjectsSALIX-HNE-MIB
1.3.6.1.4.1.2158.3.1.1.1.1hneSystemSALIX-HNE-MIB
1.3.6.1.4.1.2158.3.1.1.1.1.2hneSystemSyncSALIX-HNE-MIB
1.3.6.1.4.1.2158.3.1.1.1.1.2.4hneSysSyncRevertiveSwitchSALIX-HNE-MIB