All MIBs › SALIX-HNE-MIB › hneSysSyncPrimaryRefLineState
hneSysSyncPrimaryRefLineState
Module: SALIX-HNE-MIB
OID (symbolic): SALIX-HNE-MIB::hneSysSyncPrimaryRefLineState
OID (numeric): 1.3.6.1.4.1.2158.3.1.1.1.1.2.11
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This variable indicates the state of the primary reference line termination point (SONET line) to be used as a timing source by the sync module. This object is relevant if the hneSysSyncTimingMode is set to 'line' and the hneSysSyncPrimaryRefLine is configured.
unknown(0) - the state of the line has not been determined. valid(1) - the line is operating within the frequency specification. lossOfSignalError - loss of signal was detected from the line and has failed the health check. frequencyOffsetError - frequency errors were detected from the line and has failed the health check
What is hneSysSyncPrimaryRefLineState?
Read-only enum reporting the health of the primary reference line used for timing: unknown, valid, lossOfSignalError, or frequencyOffsetError. An admin checks this when timing looks unstable to see whether the primary reference itself has failed its health check.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2158.3.1.1.1.1.2.11 snmpwalk -v2c -c public <target> SALIX-HNE-MIB::hneSysSyncPrimaryRefLineState
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2158.3.1.1.1.1.2.11.1 snmpget -v2c -c public <target> SALIX-HNE-MIB::hneSysSyncPrimaryRefLineState.1
Start monitoring SALIX Technologies network/telecom access equipment (Host Network Element identification/config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SALIX-HNE-MIB::hneSysSyncPrimaryRefLineState OID value, configure state conditions and alerts, and monitor any SALIX Technologies network/telecom access equipment (Host Network Element identification/config) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2158 | salixTechnologies | SALIX-MIB |
| 1.3.6.1.4.1.2158.3 | salixProducts | SALIX-MIB |
| 1.3.6.1.4.1.2158.3.1 | hybridSwitch | SALIX-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2158.3.1.1 | hneMIB | SALIX-HNE-MIB |
| 1.3.6.1.4.1.2158.3.1.1.1 | hneMIBObjects | SALIX-HNE-MIB |
| 1.3.6.1.4.1.2158.3.1.1.1.1 | hneSystem | SALIX-HNE-MIB |
| 1.3.6.1.4.1.2158.3.1.1.1.1.2 | hneSystemSync | SALIX-HNE-MIB |
| 1.3.6.1.4.1.2158.3.1.1.1.1.2.11 | hneSysSyncPrimaryRefLineState | SALIX-HNE-MIB |