SALIX-HNE-MIB :: hneSonetProtectionRevertive

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SALIX-HNE-MIB › hneSonetProtectionRevertive

hneSonetProtectionRevertive

Module: SALIX-HNE-MIB

OID (symbolic): SALIX-HNE-MIB::hneSonetProtectionRevertive

OID (numeric): 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.5

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Indication of whether or not the role of 'working' should return after a failure is cleared. See GR-253-CORE.

true(1) - protection switching is revertive false(2) - protection switching is non-revertive

What is hneSonetProtectionRevertive?

Read-write boolean controlling whether the 'working' role automatically reverts to the originally-designated line once a protection-switch failure clears, per GR-253-CORE. Enable it when the original working line is preferred and should be restored to active duty as soon as it's healthy again.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.5
snmpwalk -v2c -c public <target> SALIX-HNE-MIB::hneSonetProtectionRevertive

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.5.1
snmpget -v2c -c public <target> SALIX-HNE-MIB::hneSonetProtectionRevertive.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2158.3.1.1.1.2.2.1.5.1 s <value>

Start monitoring SALIX Technologies network/telecom access equipment (Host Network Element identification/config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SALIX-HNE-MIB::hneSonetProtectionRevertive OID value, configure state conditions and alerts, and monitor any SALIX Technologies network/telecom access equipment (Host Network Element identification/config) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2158salixTechnologiesSALIX-MIB
1.3.6.1.4.1.2158.3salixProductsSALIX-MIB
1.3.6.1.4.1.2158.3.1hybridSwitchSALIX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2158.3.1.1hneMIBSALIX-HNE-MIB
1.3.6.1.4.1.2158.3.1.1.1hneMIBObjectsSALIX-HNE-MIB
1.3.6.1.4.1.2158.3.1.1.1.2hneSonetSALIX-HNE-MIB
1.3.6.1.4.1.2158.3.1.1.1.2.2hneSonetProtectionTableSALIX-HNE-MIB
1.3.6.1.4.1.2158.3.1.1.1.2.2.1hneSonetProtectionEntrySALIX-HNE-MIB
1.3.6.1.4.1.2158.3.1.1.1.2.2.1.5hneSonetProtectionRevertiveSALIX-HNE-MIB