| OID symbolic | OID numeric | Type | Access | Description |
| rsXx8000 | 1.3.6.1.4.1.2566.127.1.2.167 | | | The subtree for all transmitters of series 8000. |
| rsXx8000Common | 1.3.6.1.4.1.2566.127.1.2.167.1 | | | This is the subtree for values which every equipement of series 8000 suports. |
| rsXx8000CommonObjs | 1.3.6.1.4.1.2566.127.1.2.167.1.1 | | | |
| productInformation | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1 | | | |
| STR serialNumber | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.2 | ReadableString | read-only | The serial number of the device. |
| STR identNumberSW | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.3 | ReadableString | read-only | The Rohde&Schwarz identification number of the software, for example 2094.2090.02. |
| STR versionNumberSW | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.4 | ReadableString | read-only | The Rohde&Schwarz revision number of the software, for example 1.2.1. |
| STR identNumberHW | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.5 | ReadableString | read-only | The Rohde&Schwarz identification number of the hardware, for example 2095.8007.02 (NetCCU). |
| STR versionNumberHW | 1.3.6.1.4.1.2566.127.1.2.167.1.1.1.6 | ReadableString | read-only | The Rohde&Schwarz revision number (product index) of the hardware, for example 03.03. |
| snmpConfig | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2 | | | |
| trapSinkTable | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2 | | not-accessible | This table is for configuration of trapsinks - the IP-addresses where traps/informs are sent to.
This table gives you possibility for easier remote configuration of trapsinks.
Another way, which is predefined by IETF, is to use the MIBs SNMP-TARGET and SNMP-NOTIFICATION. |
| trapSinkEntry | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1 | | not-accessible | An entry for a trapsink. |
| I32 trapSinkNumber | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.1 | Integer32 | not-accessible | The arbitrary number in the list. |
| INT trapSinkVersion | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.2 | INTEGER | read-write | The SNMP-version of sent out alarm.
1: v1Trap
2: v2Trap
3: v2Inform |
| IP trapSinkAddress | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.3 | IpAddress | read-write | The IP-Address of the SNMP manager to which the alarms are sent to. |
| I32 trapSinkPort | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.4 | Integer32 | read-write | The port of the SNMP manager to which the alarms are sent to. |
| I32 trapSinkInformRetry | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.6 | Integer32 | read-write | only used for informs:
number of times to resend the inform |
| I32 trapSinkInformTimeout | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.7 | Integer32 | read-write | only used for informs:
timeout between retries |
| I32 trapSinkInformUnacknowledged | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.8 | Integer32 | read-write | only used for informs:
maximum number of waiting informs
if this is reached, the oldest pending inform is discarded |
| T/F trapSinkUse | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.2.1.9 | TruthValue | read-write | on/off-switch for this sink |
| TRI sendTestTrap | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.3 | Trigger | read-write | 1: idle
2: Agent generates the trap 'testTrap', which is useful when checking the
connection between agent (NetCCU) and your trapsink. |
| TRI irtTrapsAllOn | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.4 | Trigger | read-write | This switches all IRT-traps on - traps for all events are sent out.
In detail, this means in the IRT-MIBs under branches *EventEnable all
OIDs are set to 1.
Caution!
Setting this value influences remote controlling of devices.
Too many alarms may flood your network. Use this only for testing - for
operation, we suggest switch on only a few important traps. |
| TRI irtTrapsAllOff | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.5 | Trigger | read-write | This switches all IRT-traps off - no traps are sent out.
In detail, this means in the IRT-MIBs under branches *EventEnable all
OIDs are set to 2.
Note: This is typically set when using only R&S-MIBs
and you don't need IRT-MIBs. |
| TRI rsTrapsAllOn | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.6 | Trigger | read-write | This switches all R&S-traps on - traps for all events (info, warning, fault) are sent out.
In detail, this means in the R&S-MIBs under *Events - Events*Table in
column event*Mask all OIDs are set to 1.
Caution!
Enabling all traps is not recommended!
Caution!
Setting this value influences remote controlling of devices!
Too many alarms may flood your network. Use this only for testing - for
operation, we suggest switch on only a few important traps.
Caution!
This enables absolutely all R&S alarms!
Make sure you can handle it (network speed, routers, firewalls, NOC database performance etc.). |
| TRI rsTrapsAllOff | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.7 | Trigger | read-write | This switches all R&S-traps off - no traps are sent out.
In detail, this means in the R&S-MIBs under *Events - Events*Table in
column event*Mask all OIDs are set to 2.
Note: This is typically set when using only IRT-MIBs
and you don't need R&S-MIBs. |
| TRI rsTrapsAllFaultsOn | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.8 | Trigger | read-write | This switches all R&S-traps for faults on - traps for all 'faults' are sent out.
In detail, this means in the R&S-MIBs under *Events - Events*Table in
column event*Mask all 'fault'-OIDs are set to '1'.
These traps include the value 'fault(1)' in binding 'eventAlarmClass'.
Note: This is the recommended setting when using R&S-MIBs. It gives you an
overview of the device state. |
| TRI rsTrapsAllFaultsOff | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.9 | Trigger | read-write | This switches all R&S-traps for faults off - no traps for 'faults' are sent out.
In detail, this means in the R&S-MIBs under *Events - Events*Table in
column event*Mask all 'fault'-OIDs are set to '2'.
These traps include the value 'fault(1)' in binding 'eventAlarmClass'. |
| TRI rsTrapsAllWarningsOn | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.10 | Trigger | read-write | This switches all R&S-traps for warnings on - traps for all 'warnings' are sent out.
In detail, this means in the R&S-MIBs under *Events - Events*Table in
column event*Mask all 'warning'-OIDs are set to '1'.
These traps include the value 'warning(2)' in binding 'eventAlarmClass'.
Note: This is the recommended setting when using R&S-MIBs and you want much more
informations from the device than only faults.
Caution!
This enables lots of alarms.
Make sure you can handle it (network speed, NOC database performance etc.)... |
| TRI rsTrapsAllWarningsOff | 1.3.6.1.4.1.2566.127.1.2.167.1.1.2.11 | Trigger | read-write | This switches all R&S-traps for warnings off - no traps for 'warnings' are sent out.
In detail, this means in the R&S-MIBs under *Events - Events*Table in
column event*Mask all 'warning'-OIDs are set to '2'.
These traps include the value 'warning(2)' in binding 'eventAlarmClass'. |
| transmitterConfig | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3 | | | |
| DAT dateTime | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.1 | DateAndTime | read-write | The date and time for the transmitter.
Notes: Deci-seconds different from 0 are ignored.
The range of distance from UTC is -12h..+14h.
Omitting the optional UTC fields in a set-request results in keeping the
old UTC offset values. |
| ntp | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2 | | | |
| INT ntpMode | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.1 | INTEGER | read-write | Configures the working mode of the NTP client.
disabled: no ntp synchronisation will be done
step: the time will synchronized every NTP sync-time
unknown: NTP mode is currently not determinable. This value must not be written. |
| I32 ntpSyncTimeInterval | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.2 | Integer32 | read-write | Set the intervall, how often the NTP client will be synchronized to the NTP server.
Note: this is useful in step mode only . |
| ntpServerAddrTable | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3 | | not-accessible | Table with server adresses.
Currently maximal one entry is allowed. |
| ntpServerAddrEntry | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3.1 | | not-accessible | An entry for a ntpServerAddrTable. |
| I32 ntpServerAddrIdx | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3.1.1 | Integer32 | not-accessible | index for table entry. |
| STR ntpServerAddress | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.3.1.2 | ReadableString | read-write | host name or IP address of server. |
| INT ntpState | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.4 | INTEGER | read-only | Shows the actual state of the NTP synchronisation. |
| DAT ntpLastSync | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.2.5 | DateAndTime | read-only | The date/time of the last successful synchronisation. |
| swMaintenance | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5 | | | |
| TRI restart | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.1 | Trigger | read-write | Restart the software of transmitter's control unit. |
| swUpdate | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5 | | | |
| TRI swUpdateStart | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.2 | Trigger | read-write | Start software update tool at transmitter side in manual mode. The PC tool can only connect
to transmitter's control unit if the software update tool on the transmitter is started. |
| INT swUpdateMode | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.3 | INTEGER | read-write | Run mode of the software update tool at the transmitter side.
manual: Software update can be started with the Start button. It will stop automaticly after
an idle period of 90 seconds.
permanent: Software update is always running and will never stop. |
| STR swUpdateDeviceName | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.4 | ReadableString | read-write | The Device Name is dedicated to this control unit. It will be shown in the software update tool on the PC to differ devices. |
| STR swUpdateDeviceGroup | 1.3.6.1.4.1.2566.127.1.2.167.1.1.3.5.5.5 | ReadableString | read-write | The Device Group can be used to separate devices in large networks.
It must match the Device Group in software update tool on the PC. |
| rsXx8000CommonEvents | 1.3.6.1.4.1.2566.127.1.2.167.1.2 | | | |
| rsXx8000EventsV2 | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0 | | | |
| NTF testTrap | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.1 | | | This trap is sent to check whether the trapsink is receiving any traps
from this agent. To trigger this trap, set 'sendTestTrap' to '2'. |
| eventTx | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10 | | | |
| eventsTxV2 | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.0 | | | Compatibility to SMIv1. |
| NTF swUpdateStarted | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.0.1 | | | Software update started.
The PC tool can only connect to transmitter's control unit if the software
update tool on the transmitter is started. It uses the network 17 (TCP and UDP). |
| NTF ntpSyncFailed | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.0.2 | | | NTP synchronisation failed. |
| eventsTxTable | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1 | | not-accessible | This table contains necessary information for handling alarms.
For each alarm you have the following information:
- name (get),
- mask to enable/disable sending out (set/get),
- priority (set/get) and
- the current state (get only). |
| eventsTxEntry | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1 | | not-accessible | An event entry always consists of 3 values:
- name: an enumerated list of all possible notifications
- mask: the corresponding mask (enable/disable)
- priority: the corresponding priority (value in range 0..255)
- event: the event itself (active/inactive) |
| EVE eventTxNameIdx | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.1 | EventMaxEntryNumber | not-accessible | The event number as integer.
This is a helper column and therefore not-accessible. |
| INT eventTxName | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.2 | INTEGER | read-only | The event number as integer and the value as readable text.
The enumeration correlates with the notifications under eventsTxV2. |
| EVE eventTxMask | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.3 | EventMask | read-write | See TextualConvention for details. |
| EVE eventTxPriority | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.4 | EventPriority | read-write | See TextualConvention for details. |
| EVE eventTxEvent | 1.3.6.1.4.1.2566.127.1.2.167.1.2.0.10.1.1.5 | EventState | read-only | See TextualConvention for details. |
| eventHistory | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1 | | | Information about sent out events. |
| C32 counterEvents | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.1 | Counter32 | read-only | The total number of traps sent out.
This is an increasing value. |
| eventHistoryTable | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2 | | not-accessible | The table of the last 100 messages sent out. |
| eventHistoryEntry | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1 | | not-accessible | An event entry. |
| I32 eventHistoryNumber | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.1 | Integer32 | not-accessible | The trap number. |
| INT eventHistoryModule | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.2 | INTEGER | read-only | This column indicates the physical module the corresponding message is for. |
| I32 eventHistoryEvent | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.3 | Integer32 | read-only | This column indicates the event.
In correlation with column eventHistoryModule, you can see the name of the event here.
For this, you need to have a look at the event definitions of the corresponding MIB.
Example:
For a DVB transmitter an entry in eventHistoryModule is netccu(2) and
the value in eventHistoryEvent is 1.
A look at eventsTxV2 of RS-XX8000-DVB-TX-MIB shows, 1 is txSummaryFault. |
| EVE eventHistoryEventState | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.4 | EventState | read-only | See TextualConvention for details. |
| DAT eventHistoryEventDate | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.5 | DateAndTime | read-only | This column indicates the date and time of the event. |
| IND eventHistoryTx | 1.3.6.1.4.1.2566.127.1.2.167.1.2.1.2.1.101 | IndexTransmitter | read-only | The transmitter index in case of NTx or Np1 systems.
For variants with one transmitter only (SingleTx) this index is always transmitterB(1). |
| eventMapObjects | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3 | | | |
| EVE eventAlarmPriority | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.1 | EventPriority | accessible-for-notify | This OID holds the value for the priority when sending out a notification. |
| EVE eventAlarmClass | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.2 | EventClass | accessible-for-notify | See TextualConvention for details. |
| EVE eventEvent | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.3 | EventState | accessible-for-notify | This OID holds the value for the event itself when sending out a notification. |
| IND indexAB | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.5 | IndexAB | accessible-for-notify | This OID holds the value for the module A (exciterA, outputstageA) or
B (exciterB, outputstageB) when sending out a notification. |
| IND indexRack | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.6 | IndexRack | accessible-for-notify | This OID holds the value for the rack when sending out a notification. |
| IND indexAmplifier | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.7 | IndexAmplifier | accessible-for-notify | This OID holds the value for the amplifier when sending out a notification. |
| IND indexProgram | 1.3.6.1.4.1.2566.127.1.2.167.1.2.3.8 | IndexProgram | accessible-for-notify | This object holds the value for the program when sending out a notification. |
| rsXx8000CommonConf | 1.3.6.1.4.1.2566.127.1.2.167.1.3 | | | |
| rsXx8000CommonGroups | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1 | | | |
| groupNotifyTest | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.1 | | | test notifications. |
| groupNotify | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.2 | | | notifications for all transmitters. |
| groupEventTest | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.6 | | | The objects sent with testTrap. |
| groupEventHistory | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.8 | | | Contains all objects from 'eventHistory'. |
| groupEventObjects | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.9 | | | Contains all objects from 'eventMapObjects'. |
| groupProductInformation | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.11 | | | Contains all objects from 'productInformation' (R&S typeplate). |
| groupSnmpConfig | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.12 | | | Contains all objects from 'snmpConfig'. |
| groupTransmitterConfig | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.13 | | | objects from 'transmitterConfig'. |
| groupNTP | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.14 | | | objects from 'ntp' |
| groupSwMaintenance | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.15 | | | objects from 'swMaintenance' |
| groupNotifyNTP | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.16 | | | Notifications from the NTP client. |
| groupObsoletedObjects | 1.3.6.1.4.1.2566.127.1.2.167.1.3.1.17 | | | Description. |
| rsXx8000CommonCompls | 1.3.6.1.4.1.2566.127.1.2.167.1.3.2 | | | |
| xx8000BasicCompliance | 1.3.6.1.4.1.2566.127.1.2.167.1.3.2.1 | | | The compliance statement for XX8000 entities which implement this MIB module. |
| rsXx8000MibModule | 1.3.6.1.4.1.2566.149.1.163 | | | This MIB defines general objects of XX8000 transmitting systems from Rohde & Schwarz.
Use this MIB for things all transmitters support via SNMP, e.g.:
- product information
- installation / configuration issues (trapsinks, managers aso.)
The following MIBs are related to this:
- RS-COMMON-MIB - mandatory for this MIB. |