All MIBs › RETIX-METROLAN-MIB › ssErrorLog
ssErrorLog
Module: RETIX-METROLAN-MIB
OID (symbolic): RETIX-METROLAN-MIB::ssErrorLog
OID (numeric): 1.3.6.1.4.1.72.20.2.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description:
A stored value indicating that the unit has experienced a fault. Log information is formatted as a four digit hex number. Set to zero to clear the logged fault. Record this value and call Retix technical support.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.72.20.2.3 snmpwalk -v2c -c public <target> RETIX-METROLAN-MIB::ssErrorLog
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.72.20.2.3.1 snmpget -v2c -c public <target> RETIX-METROLAN-MIB::ssErrorLog.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.72.20.2.3.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> ssErrorLog.1