REPEATER-REV4-MIB :: rptrPortAlarmCollPortDisable

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › REPEATER-REV4-MIB › rptrPortAlarmCollPortDisable

rptrPortAlarmCollPortDisable

Module: REPEATER-REV4-MIB

OID (symbolic): REPEATER-REV4-MIB::rptrPortAlarmCollPortDisable

OID (numeric): 1.3.6.1.4.1.52.4.1.1.1.4.3.3.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Set will permit a port to be disabled on a collision alarm condition. Get will show whether the port disabling is allowed or not.

What is rptrPortAlarmCollPortDisable?

Controls whether this specific port is automatically disabled when its own collision alarm condition fires — enable(2) permits the port to be shut down on alarm, disable(1) leaves it running.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.1.4.3.3.1.8
snmpwalk -v2c -c public <target> REPEATER-REV4-MIB::rptrPortAlarmCollPortDisable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.1.4.3.3.1.8.1
snmpget -v2c -c public <target> REPEATER-REV4-MIB::rptrPortAlarmCollPortDisable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.1.1.1.4.3.3.1.8.1 i <value>

Start monitoring vendor-neutral, standards-based MIB (RFC 1516/IEEE 802.3), Ethernet repeater hubs (port status/collision statistics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the REPEATER-REV4-MIB::rptrPortAlarmCollPortDisable OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB (RFC 1516/IEEE 802.3), Ethernet repeater hubs (port status/collision statistics) from a single console.

OID Breakdown

Upper-level ancestors (15 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.1ctronCTRON-ISDN-CONFIGURATION-MIB
1.3.6.1.4.1.52.4.1.1ctPhysicalCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1.1repeaterRev4CTRON-MIB-NAMES
1.3.6.1.4.1.52.4.1.1.1.4repeaterRev4REPEATER-MIB
1.3.6.1.4.1.52.4.1.1.1.4.3rptrPortREPEATER-MIB
1.3.6.1.4.1.52.4.1.1.1.4.3.3rptrPortAlarmTableREPEATER-MIB
1.3.6.1.4.1.52.4.1.1.1.4.3.3.1rptrPortAlarmEntryREPEATER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.1.1.1.4.3.3.1.8rptrPortAlarmCollPortDisableREPEATER-REV4-MIB