RBN-OPTICAL-TRANSCEIVER-MIB :: rbnOpticalTransceiverActiveAlarmCount

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › RBN-OPTICAL-TRANSCEIVER-MIB › rbnOpticalTransceiverActiveAlarmCount

rbnOpticalTransceiverActiveAlarmCount

Module: RBN-OPTICAL-TRANSCEIVER-MIB

OID (symbolic): RBN-OPTICAL-TRANSCEIVER-MIB::rbnOpticalTransceiverActiveAlarmCount

OID (numeric): 1.3.6.1.4.1.2352.2.50.1.1.1.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Number of alarms active on the Optical Transceiver

What is rbnOpticalTransceiverActiveAlarmCount?

Reports how many alarms are currently active on this optical transceiver; a non-zero value tells an admin to check the transceiver parameter and lane tables for the specific threshold that's been crossed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2352.2.50.1.1.1.18
snmpwalk -v2c -c public <target> RBN-OPTICAL-TRANSCEIVER-MIB::rbnOpticalTransceiverActiveAlarmCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2352.2.50.1.1.1.18.1
snmpget -v2c -c public <target> RBN-OPTICAL-TRANSCEIVER-MIB::rbnOpticalTransceiverActiveAlarmCount.1

Start monitoring Ericsson SmartEdge SSR line card with pluggable optics (SFP/XFP transceiver inventory/diagnostics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RBN-OPTICAL-TRANSCEIVER-MIB::rbnOpticalTransceiverActiveAlarmCount OID value, configure state conditions and alerts, and monitor any Ericsson SmartEdge SSR line card with pluggable optics (SFP/XFP transceiver inventory/diagnostics) from a single console.

How to Use in IPNetwork Monitor

Select an Ericsson SmartEdge SSR line card with pluggable optic (SFP/XFP transceiver inventory/diagnostics) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rbnOpticalTransceiverActiveAlarmCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the number of alarms active on the Optical Transceiver. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate the underlying set of items changed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2352redBackNetworksRBN-SMI
1.3.6.1.4.1.2352.2rbnMgmtRBN-SMI
1.3.6.1.4.1.2352.2.50rbnAtm2MIBRBN-ATM2-MIB
1.3.6.1.4.1.2352.2.50.1rbnAtm2MIBObjectsRBN-ATM2-MIB
1.3.6.1.4.1.2352.2.50.1.1rbnAtm2VplStatTableRBN-ATM2-MIB
1.3.6.1.4.1.2352.2.50.1.1.1rbnAtm2VplStatEntryRBN-ATM2-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2352.2.50.1.1.1.18rbnOpticalTransceiverActiveAlarmCountRBN-OPTICAL-TRANSCEIVER-MIB