RAISECOM-DOT1AG-MIB :: rcDot1agCfmMepCcmSequenceErrors

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RAISECOM-DOT1AG-MIB › rcDot1agCfmMepCcmSequenceErrors

rcDot1agCfmMepCcmSequenceErrors

Module: RAISECOM-DOT1AG-MIB

OID (symbolic): RAISECOM-DOT1AG-MIB::rcDot1agCfmMepCcmSequenceErrors

OID (numeric): 1.3.6.1.4.1.8886.6.1.32.1.7.1.1.17

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of out-of-sequence CCMs received from all remote MEPs.

What is rcDot1agCfmMepCcmSequenceErrors?

This counts CCMs received out of sequence from any remote MEP, a sign of lost or reordered CCM frames on the path.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8886.6.1.32.1.7.1.1.17
snmpwalk -v2c -c public <target> RAISECOM-DOT1AG-MIB::rcDot1agCfmMepCcmSequenceErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8886.6.1.32.1.7.1.1.17.1
snmpget -v2c -c public <target> RAISECOM-DOT1AG-MIB::rcDot1agCfmMepCcmSequenceErrors.1

Start monitoring Raisecom, Inc. carrier Ethernet switches (802.1ag CFM extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RAISECOM-DOT1AG-MIB::rcDot1agCfmMepCcmSequenceErrors OID value, configure state conditions and alerts, and monitor any Raisecom, Inc. carrier Ethernet switches (802.1ag CFM extensions) from a single console.

How to Use in IPNetwork Monitor

Select a Raisecom, Inc. carrier Ethernet switch (802.1ag CFM extensions) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rcDot1agCfmMepCcmSequenceErrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of out-of-sequence CCMs received from all remote MEPs. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8886raisecomRAISECOM-BASE-MIB
1.3.6.1.4.1.8886.6iscomSeriesRAISECOM-BASE-MIB
1.3.6.1.4.1.8886.6.1iscomSwitchRAISECOM-BASE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8886.6.1.32rcDot1agRAISECOM-DOT1AG-MIB
1.3.6.1.4.1.8886.6.1.32.1rcDot1agMIBObjectsRAISECOM-DOT1AG-MIB
1.3.6.1.4.1.8886.6.1.32.1.7rcDot1agCfmMepRAISECOM-DOT1AG-MIB
1.3.6.1.4.1.8886.6.1.32.1.7.1rcDot1agCfmMepTableRAISECOM-DOT1AG-MIB
1.3.6.1.4.1.8886.6.1.32.1.7.1.1rcDot1agCfmMepEntryRAISECOM-DOT1AG-MIB
1.3.6.1.4.1.8886.6.1.32.1.7.1.1.17rcDot1agCfmMepCcmSequenceErrorsRAISECOM-DOT1AG-MIB