RADLAN-OSPFV3-MIB :: rlOspfv3OriginateNewLsas

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RADLAN-OSPFV3-MIB › rlOspfv3OriginateNewLsas

rlOspfv3OriginateNewLsas

Module: RADLAN-OSPFV3-MIB

OID (symbolic): RADLAN-OSPFV3-MIB::rlOspfv3OriginateNewLsas

OID (numeric): 1.3.6.1.4.1.89.216.2.1.9

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of new link state advertisements that have been originated. This number is incremented each time the router originates a new LSA.

Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by the value of ospfv3DiscontinuityTime.

What is rlOspfv3OriginateNewLsas?

This counter increments each time the router originates a brand-new LSA of its own. Admins can watch this counter for unusual spikes, which often indicate topology instability causing the router to keep regenerating LSAs. Because it is a counter, it only ever increases between discontinuities, so it should be read as a rate over time rather than an absolute count.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.89.216.2.1.9
snmpwalk -v2c -c public <target> RADLAN-OSPFV3-MIB::rlOspfv3OriginateNewLsas

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.89.216.2.1.9.1
snmpget -v2c -c public <target> RADLAN-OSPFV3-MIB::rlOspfv3OriginateNewLsas.1

Start monitoring Marvell (formerly RADLAN) Layer 3 switches/routers (multi-instance OSPFv3) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADLAN-OSPFV3-MIB::rlOspfv3OriginateNewLsas OID value, configure state conditions and alerts, and monitor any Marvell (formerly RADLAN) Layer 3 switches/routers (multi-instance OSPFv3) from a single console.

How to Use in IPNetwork Monitor

Select a Marvell (formerly RADLAN) Layer 3 switch/router (multi-instance OSPFv3) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rlOspfv3OriginateNewLsas into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of new link state advertisements that have been originated. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.89rndDell-MIB
Numeric OIDNameModule
1.3.6.1.4.1.89.216rlOspfv3RADLAN-OSPFV3-MIB
1.3.6.1.4.1.89.216.2rlOspfv3GeneralGroupTableRADLAN-OSPFV3-MIB
1.3.6.1.4.1.89.216.2.1rlOspfv3GeneralGroupEntryRADLAN-OSPFV3-MIB
1.3.6.1.4.1.89.216.2.1.9rlOspfv3OriginateNewLsasRADLAN-OSPFV3-MIB