RADIO-BRIDGE-MIB :: rbSysReset

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › RADIO-BRIDGE-MIB › rbSysReset

rbSysReset

Module: RADIO-BRIDGE-MIB

OID (symbolic): RADIO-BRIDGE-MIB::rbSysReset

OID (numeric): 1.3.6.1.4.1.31926.1.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Read the variable value and then write this value for reset

What is rbSysReset?

A reboot trigger: per the vendor's description, read the current value and write that same value back to reset the unit. This lets an admin remotely reboot the radio bridge, useful for recovering a hung unit without a truck roll to the tower or rooftop site.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.31926.1.4
snmpwalk -v2c -c public <target> RADIO-BRIDGE-MIB::rbSysReset

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.31926.1.4.1
snmpget -v2c -c public <target> RADIO-BRIDGE-MIB::rbSysReset.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.31926.1.4.1 i <value>

Start monitoring microwave radio bridge link unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the RADIO-BRIDGE-MIB::rbSysReset OID value, configure state conditions and alerts, and monitor any microwave radio bridge link unit from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.31926radioBridgeRootRADIO-BRIDGE-MIB
1.3.6.1.4.1.31926.1radioBridgeSystemRADIO-BRIDGE-MIB
1.3.6.1.4.1.31926.1.4rbSysResetRADIO-BRIDGE-MIB