All MIBs › PSNA-PS-psmA-MIB
Category: System Management, UPS and Power
Description:
Manages power supply module A configuration, input voltage status, and fault notification for modular chassis systems.
Imported Objects
What Is PSNA-PS-psmA-MIB?
PSNA-PS-psmA-MIB is a vendor enterprise MIB focused on power supply module A within a modular chassis system, placing it squarely in the hardware environmental-monitoring technology area. Though its sample content is sparse (only import statements retrieved), the module name and short description indicate it exposes power-supply-specific data: module presence/configuration, input voltage status, and fault condition. Its entire purpose is hardware status monitoring -- confirming whether power supply module A is present, receiving proper input voltage, and operating without fault, with notifications raised on failure conditions. Chassis power-supply MIBs of this kind typically rely on a companion entity/physical-inventory convention (similar to ENTITY-MIB) to identify the module's physical slot, though this cannot be confirmed from the available content. It is deployed in modular/chassis-based network or server equipment where redundant power supplies must be monitored for input power loss or failure. Engineers can download the PSNA-PS-psmA-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in PSNA-PS-psmA-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- power supply module presence
- input voltage status
- power supply fault condition
Supported Devices
- modular chassis network/server equipment with redundant power supplies
Monitoring Examples
An operator would poll the power-supply-A status object to confirm presence and normal input voltage, and would watch for a fault notification if psmA loses input power or reports an internal failure. Comparing status across redundant power modules (A and B, if present) would reveal whether the chassis is running on a single remaining supply after a failure. A transition from a normal to a fault or absent state would typically be treated as a critical hardware alert requiring immediate attention.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| emersonNetworkPower | 1.3.6.1.4.1.13400 | |||
| products | 1.3.6.1.4.1.13400.2 | |||
| psm | 1.3.6.1.4.1.13400.2.8 | |||
| NTF psOnNormal | 1.3.6.1.4.1.13400.2.8.0.1 | INFORMATION: The Power System is on normal status. | ||
| NTF communicationLost | 1.3.6.1.4.1.13400.2.8.0.2 | SEVERE: Communication with the Power System lost. | ||
| NTF communicationResumed | 1.3.6.1.4.1.13400.2.8.0.3 | INFORMATION: Communication with the Power System Resumed. | ||
| NTF acFail | 1.3.6.1.4.1.13400.2.8.0.4 | SEVERE: AC Power failed. | ||
| NTF acResumed | 1.3.6.1.4.1.13400.2.8.0.5 | INFORMATION: AC power Resumed. | ||
| NTF acVoltageoutofRange | 1.3.6.1.4.1.13400.2.8.0.6 | SEVERE: AC voltage is out of normal range. | ||
| NTF acVoltageNormal | 1.3.6.1.4.1.13400.2.8.0.7 | INFORMATION: AC voltage is normal. | ||
| NTF dcVoltageoutofRange | 1.3.6.1.4.1.13400.2.8.0.8 | SEVERE: DC voltage is out of normal range. | ||
| NTF dcVoltageNormal | 1.3.6.1.4.1.13400.2.8.0.9 | INFORMATION: DC voltage is normal. | ||
| NTF llvd | 1.3.6.1.4.1.13400.2.8.0.10 | SEVERE: Load low voltage disconnected. | ||
| NTF llvdResumed | 1.3.6.1.4.1.13400.2.8.0.11 | INFORMATION: Load low voltage disconnection resumed. | ||
| NTF blvd | 1.3.6.1.4.1.13400.2.8.0.12 | SEVERE: Battery low voltage disconnected. | ||
| NTF blvdResumed | 1.3.6.1.4.1.13400.2.8.0.13 | INFORMATION: Battery low voltage disconnection resumed. | ||
| NTF highTemperature | 1.3.6.1.4.1.13400.2.8.0.14 | SEVERE: The temperature around battery is too high. | ||
| NTF highTemperatureResumed | 1.3.6.1.4.1.13400.2.8.0.15 | INFORMATION: The temperature around battery is normal. | ||
| NTF dcRouteDisconnect | 1.3.6.1.4.1.13400.2.8.0.16 | SEVERE: Some DC route(s) disconnected. | ||
| NTF dcRouteDisconnectResumed | 1.3.6.1.4.1.13400.2.8.0.17 | INFORMATION: DC route(s) disconnection resumed. | ||
| NTF batteryRouteDisconnect | 1.3.6.1.4.1.13400.2.8.0.18 | SEVERE: The battery route(s) disconnected. | ||
| NTF batteryRouteDisconnectResumed | 1.3.6.1.4.1.13400.2.8.0.19 | INFORMATION: The battery route(s) disconnection resumed. | ||
| NTF acSPDfault | 1.3.6.1.4.1.13400.2.8.0.20 | SEVERE: AC SPD fault. | ||
| NTF acSPDfaultResumed | 1.3.6.1.4.1.13400.2.8.0.21 | INFORMATION: AC SPD fault resumed. | ||
| NTF acCircuitBreakerfault | 1.3.6.1.4.1.13400.2.8.0.22 | SEVERE: AC circuit breaker fault. | ||
| NTF acCircuitBreakerfaultResumed | 1.3.6.1.4.1.13400.2.8.0.23 | INFORMATION: AC circuit breaker fault resumed. | ||
| NTF batteryCurrentOver | 1.3.6.1.4.1.13400.2.8.0.24 | SEVERE: Battery current is over limit. | ||
| NTF batteryCurrentOverResumed | 1.3.6.1.4.1.13400.2.8.0.25 | INFORMATION: Battery current over resumed. | ||
| NTF rectifierFault | 1.3.6.1.4.1.13400.2.8.0.26 | SEVERE: Some Rectifier(s) fault. | ||
| NTF rectifierFaultResumed | 1.3.6.1.4.1.13400.2.8.0.27 | INFORMATION: Rectifier(s) fault resumed. | ||
| NTF rectifierProtection | 1.3.6.1.4.1.13400.2.8.0.28 | SEVERE: Some Rectifier(s) protection. | ||
| NTF rectifierProtectionResumed | 1.3.6.1.4.1.13400.2.8.0.29 | INFORMATION: Rectifier(s) protection resumed. | ||
| NTF rectifierFanFault | 1.3.6.1.4.1.13400.2.8.0.30 | SEVERE: Some Rectifier(s) fan fault. | ||
| NTF rectifierFanFaultResumed | 1.3.6.1.4.1.13400.2.8.0.31 | INFORMATION: Rectifier(s) fan fault resumed. | ||
| NTF rectifierOverTemperature | 1.3.6.1.4.1.13400.2.8.0.32 | SEVERE: Some Rectifier(s) over temperature. | ||
| NTF rectifierOverTemperatureResumed | 1.3.6.1.4.1.13400.2.8.0.33 | INFORMATION: Rectifier(s) over temperature resumed. | ||
| NTF communicationACDLost | 1.3.6.1.4.1.13400.2.8.0.34 | SEVERE: Power System communication with ACD lost. | ||
| NTF communicationACDResumed | 1.3.6.1.4.1.13400.2.8.0.35 | INFORMATION: Power System communication with ACD resumed. | ||
| NTF communicationDCDLost | 1.3.6.1.4.1.13400.2.8.0.36 | SEVERE: Power System communication with DCD lost. | ||
| NTF communicationDCDResumed | 1.3.6.1.4.1.13400.2.8.0.37 | INFORMATION: Power System communication with DCD resumed. | ||
| NTF communicationRectifierLost | 1.3.6.1.4.1.13400.2.8.0.38 | SEVERE: Power System communication with rectifier lost. | ||
| NTF communicationRectifierResumed | 1.3.6.1.4.1.13400.2.8.0.39 | INFORMATION: Power System communication with rectifier resumed. | ||
| NTF dcdcFault | 1.3.6.1.4.1.13400.2.8.0.40 | SEVERE: DC/DC convertor fault. | ||
| NTF dcdcFaultResumed | 1.3.6.1.4.1.13400.2.8.0.41 | INFORMATION: DC/DC convertor fault resumed. | ||
| psAgent | 1.3.6.1.4.1.13400.2.8.1 | |||
| INT agentRevision | 1.3.6.1.4.1.13400.2.8.1.1 | INTEGER | read-only | The firmware revision of the agent. |
| INT agentManagersNum | 1.3.6.1.4.1.13400.2.8.1.2 | INTEGER | read-only | The number of managers that can manage the agent. |
| agentManagersTable | 1.3.6.1.4.1.13400.2.8.1.3 | not-accessible | A list of managers of the agent. The number of entries is given by the value of agentManagersNum. | |
| agentManagersEntry | 1.3.6.1.4.1.13400.2.8.1.3.1 | not-accessible | The managers of the agent. | |
| INT managerIndex | 1.3.6.1.4.1.13400.2.8.1.3.1.1 | INTEGER | read-only | The index of the managers entry. |
| IP managerAddr | 1.3.6.1.4.1.13400.2.8.1.3.1.2 | IpAddress | read-write | The IP address of the manager. |
| STR publicCommunityString | 1.3.6.1.4.1.13400.2.8.1.3.1.3 | DisplayString | read-write | The public community name to use in the query request. |
| STR privateCommunityString | 1.3.6.1.4.1.13400.2.8.1.3.1.4 | DisplayString | read-write | The private community name to use in the control request. |
| INT managerPrivilege | 1.3.6.1.4.1.13400.2.8.1.3.1.5 | INTEGER | read-write | The privilege of the manager to access the agent. setting forbidden(0) indicates the manager have no any privilege to access the agent, setting query(1) indicates the manager can GET information from agent only, setting control(2) indicates the manager can GET information from agent and send control command to the agent. setting administrator(3) indicates the manager has all management privilege including set or modify this managers table. |
| INT acceptTrapLevel | 1.3.6.1.4.1.13400.2.8.1.3.1.6 | INTEGER | read-write | The severity threshold of traps to send to the manager. traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager. setting noTraps(4) indicates agent do not send any traps to the manager. |
| INT managerAccept | 1.3.6.1.4.1.13400.2.8.1.3.1.7 | INTEGER | read-write | An entry will be added if new(1), will be modified if modify(2), and will be removed if delete(3). |
| psCommon | 1.3.6.1.4.1.13400.2.8.2 | |||
| psIdent | 1.3.6.1.4.1.13400.2.8.2.1 | |||
| STR psIdentControllerModel | 1.3.6.1.4.1.13400.2.8.2.1.1 | DisplayString | read-only | The controller model of the Power System. |
| STR psIdentFirmwareRevision | 1.3.6.1.4.1.13400.2.8.2.1.2 | DisplayString | read-only | The firmware revision of the controller of the Power System. |
| STR psIdentFactory | 1.3.6.1.4.1.13400.2.8.2.1.3 | DisplayString | read-only | The name of the Power System manufacturer. |
| psSpecial | 1.3.6.1.4.1.13400.2.8.3 | |||
| psm_a | 1.3.6.1.4.1.13400.2.8.3.1 | |||
| psBattery | 1.3.6.1.4.1.13400.2.8.3.1.2 | |||
| INT psBatteryVoltage | 1.3.6.1.4.1.13400.2.8.3.1.2.1 | INTEGER | read-only | The voltage of battery in 0.1 VDC. |
| INT psBatteryCurrent | 1.3.6.1.4.1.13400.2.8.3.1.2.2 | INTEGER | read-only | The total current of the batteries in 0.1 ADC. |
| INT psBatteryTemperature | 1.3.6.1.4.1.13400.2.8.3.1.2.3 | INTEGER | read-only | The temperature around the battery in 0.1 Celsius degree. |
| psInput | 1.3.6.1.4.1.13400.2.8.3.1.3 | |||
| INT psInputLineAVoltage | 1.3.6.1.4.1.13400.2.8.3.1.3.1 | INTEGER | read-only | The AC line A voltage in 0.1 VAC. |
| INT psInputLineBVoltage | 1.3.6.1.4.1.13400.2.8.3.1.3.2 | INTEGER | read-only | The AC line B voltage in 0.1 VAC. |
| INT psInputLineCVoltage | 1.3.6.1.4.1.13400.2.8.3.1.3.3 | INTEGER | read-only | The AC line C voltage in 0.1 VAC. |
| psOutput | 1.3.6.1.4.1.13400.2.8.3.1.4 | |||
| INT psOutputVoltage | 1.3.6.1.4.1.13400.2.8.3.1.4.1 | INTEGER | read-only | The DC voltage of the Power System in 0.1 VDC. |
| INT psOutputCurrent | 1.3.6.1.4.1.13400.2.8.3.1.4.2 | INTEGER | read-only | The DC current of the Power System in 0.1 ADC. |
| psStatus | 1.3.6.1.4.1.13400.2.8.3.1.5 | |||
| INT psStatusAlarm | 1.3.6.1.4.1.13400.2.8.3.1.5.1 | INTEGER | read-only | The alarm status of the Power System. |
| INT psStatusCommunication | 1.3.6.1.4.1.13400.2.8.3.1.5.2 | INTEGER | read-only | The status of communication with the Power System. interrupt(3) indicates some errors occurred between Power System and agent. |
| INT psStatusControlMode | 1.3.6.1.4.1.13400.2.8.3.1.5.3 | INTEGER | read-only | The AUTO/MANUAL control mode of the Power System. |
| INT psStatusChargingMode | 1.3.6.1.4.1.13400.2.8.3.1.5.4 | INTEGER | read-only | The status of battery charging, floatCharging(2), equalizeCharging(3), testing(4). |
| psTest | 1.3.6.1.4.1.13400.2.8.3.1.6 | |||
| psControl | 1.3.6.1.4.1.13400.2.8.3.1.7 | |||
| psConfig | 1.3.6.1.4.1.13400.2.8.3.1.8 | |||
| psm_a9 | 1.3.6.1.4.1.13400.2.8.3.2 | |||
| psAlarm | 1.3.6.1.4.1.13400.2.8.4 | |||
| INT psAlarmPresentNum | 1.3.6.1.4.1.13400.2.8.4.1 | INTEGER | read-only | The present number of active alarams. |
| psAlarmPresentTable | 1.3.6.1.4.1.13400.2.8.4.2 | not-accessible | A list of current alarms, The number of entries is given by the value of psAlarmPresentNum. | |
| psAlarmPresentEntry | 1.3.6.1.4.1.13400.2.8.4.2.1 | not-accessible | The present alarms list. | |
| INT presentAlarmIndex | 1.3.6.1.4.1.13400.2.8.4.2.1.1 | INTEGER | read-only | The index of the present alaram entry. |
| STR presentAlarmTime | 1.3.6.1.4.1.13400.2.8.4.2.1.2 | DisplayString | read-only | The time of the alarm generated, format as mm/dd/yyyy hh:mm:ss |
| INT presentAlarmId | 1.3.6.1.4.1.13400.2.8.4.2.1.3 | INTEGER | read-only | The alarm ID. |
| STR presentAlarmName | 1.3.6.1.4.1.13400.2.8.4.2.1.4 | DisplayString | read-only | The name of the alarm. |
| INT presentAlaramLevel | 1.3.6.1.4.1.13400.2.8.4.2.1.5 | INTEGER | read-only | The alarm level. |
| STR trapArgsString | 1.3.6.1.4.1.13400.2.8.4.2008 | DisplayString | read-only | This OID allows Power System traps to be sent with an octet string argument that may not be defined in the PSNA_PS_MIB. A get of this OID will return a NULL string. |
RFC description
Power supply unit monitoring including battery, input/output and status on Emerson systems.
Start monitoring modular chassis network/server equipment with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.