| OID symbolic | OID numeric | Type | Access | Description |
| prvtSyncEthernetMIB | 1.3.6.1.4.1.738.1.5.170 | | | This is the MIB module to manage
synchronization over ethernet. |
| prvtSyncEthernetMIBNotifications | 1.3.6.1.4.1.738.1.5.170.0 | | | |
| NTF syncEthernetInvalidESMC | 1.3.6.1.4.1.738.1.5.170.0.1 | | | Invalid ESMC has been received. |
| NTF syncEthernetQualityLevelChange | 1.3.6.1.4.1.738.1.5.170.0.2 | | | Current value of syncEthernetClockSourceQuality has
been changed. |
| NTF syncEthernetInvalidQualityLevelReceived | 1.3.6.1.4.1.738.1.5.170.0.3 | | | Invalid Quality level equals to QL-INVx has been received. |
| NTF syncEthernetDPLLReferenceChange | 1.3.6.1.4.1.738.1.5.170.0.4 | | | DPLL's reference clock changed. |
| NTF syncEthernetDPLLChanged | 1.3.6.1.4.1.738.1.5.170.0.5 | | | Some of the DPLL's operational status changes. |
| NTF syncEthernetDPLLLockFailed | 1.3.6.1.4.1.738.1.5.170.0.6 | | | If after new Reference selection the DPLL can't
lock onto it, this will affect the Clock Source
associated with that reference |
| prvtSyncEthernetMIBObjects | 1.3.6.1.4.1.738.1.5.170.1 | | | |
| I32 syncEthernetHoldOffTime | 1.3.6.1.4.1.738.1.5.170.1.1 | Integer32 | read-write | Timeout value, in millisseconds, for the hold-off timer. |
| I32 syncEthernetWaitToRestoreTime | 1.3.6.1.4.1.738.1.5.170.1.2 | Integer32 | read-write | Timeout value, in minutes, for the wait-to-restore timer. |
| INT syncEthernetG781OptionMode | 1.3.6.1.4.1.738.1.5.170.1.3 | INTEGER | read-write | Specify which G.781 option mode to operate in. |
| syncEthernetClockSourceTable | 1.3.6.1.4.1.738.1.5.170.1.10 | | not-accessible | Source clock synchronization table. |
| syncEthernetClockSourceEntry | 1.3.6.1.4.1.738.1.5.170.1.10.1 | | not-accessible | Source clock synchronization entry. |
| ROW syncEthernetClockSourceRowStatus | 1.3.6.1.4.1.738.1.5.170.1.10.1.2 | RowStatus | read-create | Clock source synchronization table rowstatus. |
| INT syncEthernetClockSourceAdminStatus | 1.3.6.1.4.1.738.1.5.170.1.10.1.3 | INTEGER | read-create | Enable clock source. |
| T/F syncEthernetClockSourceEsmc | 1.3.6.1.4.1.738.1.5.170.1.10.1.4 | TruthValue | read-create | Enable receiving ESMC messages (Synchronization Status Messages).
Only applicable for BITS clock sources. |
| U32 syncEthernetClockSourceFrequency | 1.3.6.1.4.1.738.1.5.170.1.10.1.5 | Unsigned32 | read-create | Specify input frequency - N*8kHz
Only applicable for BITS clock sources. |
| PRV syncEthernetClockSourceQuality | 1.3.6.1.4.1.738.1.5.170.1.10.1.6 | PrvtSyncEthernetQualityLevelType | read-create | Specify quality level
In G781-option I mode, valid values are prs, ssuA, ssuB, dnu.
In G781-option II mode, valid values are stu, prs, tnc, st2, st3, smc, st3e, dus, prov. |
| T/F syncEthernetClockSourceQualityChangeNotify | 1.3.6.1.4.1.738.1.5.170.1.10.1.7 | TruthValue | read-create | Enable quality level change notifications |
| PRV syncEthernetClockSourceRecvQualityLevel | 1.3.6.1.4.1.738.1.5.170.1.10.1.8 | PrvtSyncEthernetQualityLevelType | read-only | The received quality level value. |
| DAT syncEthernetClockSourceLastRecvEsmcPduTime | 1.3.6.1.4.1.738.1.5.170.1.10.1.9 | DateAndTime | read-only | Time elapsed since the last valid ESMC message received |
| DAT syncEthernetClockSourceLastRecvEsmcErrorPduTime | 1.3.6.1.4.1.738.1.5.170.1.10.1.10 | DateAndTime | read-only | Time elapsed since the last invalid ESMC message received |
| U32 syncEthernetClockSourceLastRecvEsmcPduType | 1.3.6.1.4.1.738.1.5.170.1.10.1.11 | Unsigned32 | read-only | Last received ESMC message type |
| U32 syncEthernetClockSourceLastRecvLastError | 1.3.6.1.4.1.738.1.5.170.1.10.1.12 | Unsigned32 | read-only | Last error code |
| U32 syncEthernetClockSourceNumRecvEsmcPdu | 1.3.6.1.4.1.738.1.5.170.1.10.1.13 | Unsigned32 | read-only | Total number of received ESMC messages |
| U32 syncEthernetClockSourceNumDiscEsmcPdu | 1.3.6.1.4.1.738.1.5.170.1.10.1.14 | Unsigned32 | read-only | Total number of discarded ESMC messages |
| U32 syncEthernetClockSourceNumSignalFail | 1.3.6.1.4.1.738.1.5.170.1.10.1.15 | Unsigned32 | read-only | Total number of generated signal failure events |
| T/F syncEthernetClockSourceQualityInvalidNotify | 1.3.6.1.4.1.738.1.5.170.1.10.1.16 | TruthValue | read-create | Enable invalid quality notifications |
| T/F syncEthernetClockSourceEsmcInvalidNotify | 1.3.6.1.4.1.738.1.5.170.1.10.1.17 | TruthValue | read-create | Enable invalid ESMC notifications |
| syncEthernetClockOutputTable | 1.3.6.1.4.1.738.1.5.170.1.12 | | not-accessible | Output clock synchronization table. |
| syncEthernetClockOutputEntry | 1.3.6.1.4.1.738.1.5.170.1.12.1 | | not-accessible | Output clock synchronization entry. |
| ROW syncEthernetClockOutputRowStatus | 1.3.6.1.4.1.738.1.5.170.1.12.1.2 | RowStatus | read-create | syncEthernetClockOutput table rowStatus |
| T/F syncEthernetClockOutputEsmc | 1.3.6.1.4.1.738.1.5.170.1.12.1.3 | TruthValue | read-create | Enable sending ESMC messages
Only applicable for BITS clock outputs. |
| U32 syncEthernetClockOutputFrequency | 1.3.6.1.4.1.738.1.5.170.1.12.1.4 | Unsigned32 | read-create | Specify output frequency - N*8kHz
Only applicable for BITS clock outputs. |
| I32 syncEthernetClockOutputDpll | 1.3.6.1.4.1.738.1.5.170.1.12.1.5 | Integer32 | read-create | Assign output clock to DPLL
Only applicable for BITS clock outputs.
Must be set to the syncEthernetDpllModuleId value of an existing
row in syncEthernetDpllTable. |
| PRV syncEthernetClockOutputQualityLevel | 1.3.6.1.4.1.738.1.5.170.1.12.1.6 | PrvtSyncEthernetQualityLevelType | read-only | Last quality level value sent |
| DAT syncEthernetClockOutputLastQualityLevelChange | 1.3.6.1.4.1.738.1.5.170.1.12.1.7 | DateAndTime | read-only | Time elapsed since the last quality level change |
| T/F syncEthernetClockOutputMsgEvent | 1.3.6.1.4.1.738.1.5.170.1.12.1.8 | TruthValue | read-only | Last ESMC message type sent |
| U32 syncEthernetClockOutputNumTransmittedEsmcPdu | 1.3.6.1.4.1.738.1.5.170.1.12.1.9 | Unsigned32 | read-only | Total number of ESMC messages sent |
| U32 syncEthernetClockOutputNumTransmittedEventEsmcPdu | 1.3.6.1.4.1.738.1.5.170.1.12.1.10 | Unsigned32 | read-only | Total number of ESMC messages sent |
| syncEthernetDpllTable | 1.3.6.1.4.1.738.1.5.170.1.14 | | not-accessible | Synchronization DPLL table |
| syncEthernetDpllEntry | 1.3.6.1.4.1.738.1.5.170.1.14.1 | | not-accessible | Synchronization DPLL entry |
| I32 syncEthernetDpllModuleId | 1.3.6.1.4.1.738.1.5.170.1.14.1.1 | Integer32 | not-accessible | Synchronization DPLL module index |
| ROW syncEthernetDpllRowStatus | 1.3.6.1.4.1.738.1.5.170.1.14.1.2 | RowStatus | read-create | Synchronization DPLL rowstatus |
| INT syncEthernetDpllAdminStatus | 1.3.6.1.4.1.738.1.5.170.1.14.1.3 | INTEGER | read-create | Administrative status of the DPLL |
| INT syncEthernetDpllReferenceSelection | 1.3.6.1.4.1.738.1.5.170.1.14.1.4 | INTEGER | read-create | Specify reference selection mode |
| T/F syncEthernetDpllEnableQualityLevel | 1.3.6.1.4.1.738.1.5.170.1.14.1.5 | TruthValue | read-create | Enable reference selection based on quality level
Only applicable when syncEthernetDpllReferenceSelection equals g781. |
| T/F syncEthernetDpllStatusChangeNotify | 1.3.6.1.4.1.738.1.5.170.1.14.1.6 | TruthValue | read-create | Enable DPLL status change notifications |
| T/F syncEthernetDpllReferenceChangeNotify | 1.3.6.1.4.1.738.1.5.170.1.14.1.7 | TruthValue | read-create | Enable reference clock change notifications |
| INT syncEthernetDpllStatus | 1.3.6.1.4.1.738.1.5.170.1.14.1.8 | INTEGER | read-only | DPLL operational status |
| DAT syncEthernetDpllStatusLastChange | 1.3.6.1.4.1.738.1.5.170.1.14.1.9 | DateAndTime | read-only | Time since last DPLL status change |
| PRV syncEthernetDpllSystemQualityLevel | 1.3.6.1.4.1.738.1.5.170.1.14.1.10 | PrvtSyncEthernetQualityLevelType | read-only | System quality level |
| DAT syncEthernetDpllSystemQualityLevelLastChange | 1.3.6.1.4.1.738.1.5.170.1.14.1.11 | DateAndTime | read-only | Time since last system quality level change |
| OCT syncEthernetDpllSelectedReferenceClock | 1.3.6.1.4.1.738.1.5.170.1.14.1.12 | OCTET STRING | read-only | The selected reference clock source |
| DAT syncEthernetDpllSelectedReferenceClockChange | 1.3.6.1.4.1.738.1.5.170.1.14.1.13 | DateAndTime | read-only | Time since last reference clock change |
| syncEthernetDpllClkRefTable | 1.3.6.1.4.1.738.1.5.170.1.16 | | not-accessible | Synchronization DPLL clock reference table |
| syncEthernetDpllClkRefEntry | 1.3.6.1.4.1.738.1.5.170.1.16.1 | | not-accessible | Synchronization DPLL clock reference entry |
| ROW syncEthernetDpllClkRefRowStatus | 1.3.6.1.4.1.738.1.5.170.1.16.1.2 | RowStatus | read-create | Synchronization DPLL clock reference rowstatus |
| U32 syncEthernetDpllClkRefPriority | 1.3.6.1.4.1.738.1.5.170.1.16.1.3 | Unsigned32 | read-create | Specify reference clock priority |
| T/F syncEthernetDpllClkRefLockOut | 1.3.6.1.4.1.738.1.5.170.1.16.1.4 | TruthValue | read-create | Lock reference clock |
| I32 syncEthernetDpllClkRefFailStatus | 1.3.6.1.4.1.738.1.5.170.1.16.1.5 | Integer32 | read-only | DPLL reference clock status |