PRVT-SYNC-ETHERNET-MIB :: syncEthernetClockSourceRecvQualityLevel

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PRVT-SYNC-ETHERNET-MIB › syncEthernetClockSourceRecvQualityLevel

syncEthernetClockSourceRecvQualityLevel

Module: PRVT-SYNC-ETHERNET-MIB

OID (symbolic): PRVT-SYNC-ETHERNET-MIB::syncEthernetClockSourceRecvQualityLevel

OID (numeric): 1.3.6.1.4.1.738.1.5.170.1.10.1.8

Node type: OBJECT-TYPE

Type: PrvtSyncEthernetQualityLevelType

Access: read-only

Description: The received quality level value.

What is syncEthernetClockSourceRecvQualityLevel?

Reports the clock quality level actually being received on this source via ESMC, which an admin compares against syncEthernetClockSourceQuality to confirm the upstream reference is delivering what's expected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.5.170.1.10.1.8
snmpwalk -v2c -c public <target> PRVT-SYNC-ETHERNET-MIB::syncEthernetClockSourceRecvQualityLevel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.5.170.1.10.1.8.1
snmpget -v2c -c public <target> PRVT-SYNC-ETHERNET-MIB::syncEthernetClockSourceRecvQualityLevel.1

Start monitoring BATM Advanced Communications carrier Ethernet/transport switch (Synchronous Ethernet, SyncE) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-SYNC-ETHERNET-MIB::syncEthernetClockSourceRecvQualityLevel OID value, configure state conditions and alerts, and monitor any BATM Advanced Communications carrier Ethernet/transport switch (Synchronous Ethernet, SyncE) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.738privateVendorOIDPRIV-VENDORDEF-MIB
1.3.6.1.4.1.738.1prvt_productsPRVT-SWITCH-MIB
1.3.6.1.4.1.738.1.5switchPRVT-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.738.1.5.170prvtSyncEthernetMIBPRVT-SYNC-ETHERNET-MIB
1.3.6.1.4.1.738.1.5.170.1prvtSyncEthernetMIBObjectsPRVT-SYNC-ETHERNET-MIB
1.3.6.1.4.1.738.1.5.170.1.10syncEthernetClockSourceTablePRVT-SYNC-ETHERNET-MIB
1.3.6.1.4.1.738.1.5.170.1.10.1syncEthernetClockSourceEntryPRVT-SYNC-ETHERNET-MIB
1.3.6.1.4.1.738.1.5.170.1.10.1.8syncEthernetClockSourceRecvQualityLevelPRVT-SYNC-ETHERNET-MIB