All MIBs › PRVT-MPLS-TE-MIB › mplsTunnelErrorLastErrorType
mplsTunnelErrorLastErrorType
Module: PRVT-MPLS-TE-MIB
OID (symbolic): PRVT-MPLS-TE-MIB::mplsTunnelErrorLastErrorType
OID (numeric): 1.3.6.1.4.1.738.1.6.5.2.1.18.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The nature of the last error. Provides interpretation context for mplsTunnelErrorProtocolCode and mplsTunnelErrorProtocolSubcode.
A value of noError (0) shows that there is no error associated with this tunnel and means that the other objects in this table entry have no meaning.
A value of unknown (1) shows that there is an error but that no additional information about the cause is known. The error may have been received in a signaled message or generated locally.
A value of protocol (2) or pathComputation (3) indicates that the cause of an error and identifies an error that has been received through signaling or will itself be signaled.
A value of localConfiguration (4), localResources (5) or localOther (6) identifies an error which has been detected by the local node, but which will not be reported through signaling.
What is mplsTunnelErrorLastErrorType?
The nature of the last error recorded for this tunnel: noError(0) means the rest of this table row is meaningless, unknown(1) means an error occurred with no further detail, protocol(2)/pathComputation(3) mean signaling supplied a specific cause, and localConfiguration(4)/localResources(5)/localOther(6) mean the local node detected the error itself without it being signaled elsewhere.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.738.1.6.5.2.1.18.1.1 snmpwalk -v2c -c public <target> PRVT-MPLS-TE-MIB::mplsTunnelErrorLastErrorType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.738.1.6.5.2.1.18.1.1.1 snmpget -v2c -c public <target> PRVT-MPLS-TE-MIB::mplsTunnelErrorLastErrorType.1
Start monitoring BATM Advanced Communications MPLS-capable router/switch (MPLS TE tunnels) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PRVT-MPLS-TE-MIB::mplsTunnelErrorLastErrorType OID value, configure state conditions and alerts, and monitor any BATM Advanced Communications MPLS-capable router/switch (MPLS TE tunnels) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.738 | privateVendorOID | PRIV-VENDORDEF-MIB |
| 1.3.6.1.4.1.738.1 | prvt_products | PRVT-SWITCH-MIB |
| 1.3.6.1.4.1.738.1.6 | ipSwitch | PRVT-SWITCH-MIB |
| 1.3.6.1.4.1.738.1.6.5 | mpls | PRVT-CR-LDP-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.738.1.6.5.2 | mplsTeMIB | PRVT-MPLS-TE-MIB |
| 1.3.6.1.4.1.738.1.6.5.2.1 | mplsTeObjects | PRVT-MPLS-TE-MIB |
| 1.3.6.1.4.1.738.1.6.5.2.1.18 | mplsTunnelErrorTable | PRVT-MPLS-TE-MIB |
| 1.3.6.1.4.1.738.1.6.5.2.1.18.1 | mplsTunnelErrorEntry | PRVT-MPLS-TE-MIB |
| 1.3.6.1.4.1.738.1.6.5.2.1.18.1.1 | mplsTunnelErrorLastErrorType | PRVT-MPLS-TE-MIB |