PKTC-IETF-SIG-MIB :: pktcSigPulseSignalFrequency

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › PKTC-IETF-SIG-MIB › pktcSigPulseSignalFrequency

pktcSigPulseSignalFrequency

Module: PKTC-IETF-SIG-MIB

OID (symbolic): PKTC-IETF-SIG-MIB::pktcSigPulseSignalFrequency

OID (numeric): 1.3.6.1.2.1.169.1.1.20.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object is only applicable to the initialRing, enableMeterPulse, and meterPulseBurst signal types. This object identifies the frequency of the generated signal. The following table defines the default values for this object depending on signal type:

pktcSigPulseSignalType Default initialRing 25 enableMeterPulse 16000 meterPulseBurst 16000

The value of twentyfive MUST only be used for the initialRing signal type. The values of twelvethousand and sixteenthousand MUST only be used for enableMeterPulse and meterPulseBurst signal types. An attempt to set this object while the value of pktcSigPulseSignalType is not initialRing, enableMeterPulse, or meterPulseBurst will result in an 'inconsistentValue' error.

What is pktcSigPulseSignalFrequency?

Sets the tone frequency used for pulse-type signals (initial ring, meter pulse enable, or meter pulse burst); each signal type accepts only its own specific frequency values, and using it with an unrelated signal type triggers an inconsistentValue error.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.169.1.1.20.1.2
snmpwalk -v2c -c public <target> PKTC-IETF-SIG-MIB::pktcSigPulseSignalFrequency

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.169.1.1.20.1.2.1
snmpget -v2c -c public <target> PKTC-IETF-SIG-MIB::pktcSigPulseSignalFrequency.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.2.1.169.1.1.20.1.2.1 i <value>

Start monitoring PacketCable/IPCablecom-compliant cable-telephony equipment (Network Call Signaling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PKTC-IETF-SIG-MIB::pktcSigPulseSignalFrequency OID value, configure state conditions and alerts, and monitor any PacketCable/IPCablecom-compliant cable-telephony equipment (Network Call Signaling) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAPERTUS-NPG-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.169pktcIetfSigMibPKTC-IETF-SIG-MIB
1.3.6.1.2.1.169.1pktcSigMibObjectsPKTC-IETF-SIG-MIB
1.3.6.1.2.1.169.1.1pktcSigDevObjectsPKTC-IETF-SIG-MIB
1.3.6.1.2.1.169.1.1.20pktcSigPulseSignalTablePKTC-IETF-SIG-MIB
1.3.6.1.2.1.169.1.1.20.1pktcSigPulseSignalEntryPKTC-IETF-SIG-MIB
1.3.6.1.2.1.169.1.1.20.1.2pktcSigPulseSignalFrequencyPKTC-IETF-SIG-MIB