All MIBs › PEA-TEST-IPDSLAM › loopDiagHlinFePart3High
loopDiagHlinFePart3High
Module: PEA-TEST-IPDSLAM
OID (symbolic): PEA-TEST-IPDSLAM::loopDiagHlinFePart3High
OID (numeric): 1.3.6.1.4.1.193.72.300.20.1.25.1.16
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-only
Description: The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement.
What is loopDiagHlinFePart3High?
The upper half of part 3 of the far-end linear complex channel transfer function (Hlin) per tone (range -32768..32767), packed as 4 bytes per tone (2-byte real, 2-byte imaginary); -32768 in either part means no measurement. Pair with loopDiagHlinFePart3Low and scale via loopDiagHlinFeScalePart3.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.72.300.20.1.25.1.16 snmpwalk -v2c -c public <target> PEA-TEST-IPDSLAM::loopDiagHlinFePart3High
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.193.72.300.20.1.25.1.16.1 snmpget -v2c -c public <target> PEA-TEST-IPDSLAM::loopDiagHlinFePart3High.1
Start monitoring Ericsson (Diax) IP-DSLAM broadband access equipment (SELT/noise test control) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the PEA-TEST-IPDSLAM::loopDiagHlinFePart3High OID value, configure state conditions and alerts, and monitor any Ericsson (Diax) IP-DSLAM broadband access equipment (SELT/noise test control) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.193 | ericsson | ANS-COMMON-MIB |
| 1.3.6.1.4.1.193.72 | diaxMIB | DXD-SMI |
| 1.3.6.1.4.1.193.72.300 | peaIpDslam | DIESEL-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.193.72.300.20 | peaTestIpDslam | PEA-TEST-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.20.1 | peaTestIpDslamObjects | PEA-TEST-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.20.1.25 | loopDiagHlinFeTable | PEA-TEST-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.20.1.25.1 | loopDiagHlinFeEntry | PEA-TEST-IPDSLAM |
| 1.3.6.1.4.1.193.72.300.20.1.25.1.16 | loopDiagHlinFePart3High | PEA-TEST-IPDSLAM |