PEA-TEST-IPDSLAM DEFINITIONS ::= BEGIN IMPORTS peaIpDslam FROM DIESEL-SMI lineIndex, pvcIndex FROM PEA-BRIDGE-IPDSLAM -- standar X.733 header for the traps managedObjectClass, managedObjectInstance, sequenceNumber, perceivedSeverity, eventTime, eventTypePem, probableCause FROM PEM-STANDARD adslIfTestResult, adslIfTestType, adslIfTestError FROM PEA-IF-IPDSLAM DisplayString FROM SNMPv2-TC MODULE-IDENTITY, Integer32, Unsigned32, Counter32, NOTIFICATION-TYPE, OBJECT-TYPE FROM SNMPv2-SMI OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF ; peaTestIpDslam MODULE-IDENTITY LAST-UPDATED "200405031200Z" ORGANIZATION "Ericsson Diax A/S - Denmark" CONTACT-INFO " Ericsson Diax A/S Faelledvej 17 DK-7600 Struer Denmark E-mail: diax.support.xu@ericsson.com " DESCRIPTION " In this module are defined the control entries for input and output data for SELT (loop qualification) and NOISE tests. " ::= { peaIpDslam 20 } peaTestIpDslamObjects OBJECT IDENTIFIER ::= { peaTestIpDslam 1 } peaTestIpDslamTraps OBJECT IDENTIFIER ::= { peaTestIpDslam 2 } peaTestIpDslamObjectsGroups OBJECT IDENTIFIER ::= { peaTestIpDslam 3 } peaTestIpDslamTrapsGroups OBJECT IDENTIFIER ::= { peaTestIpDslam 4 } --************************************************************************ -- SELT TEST INPUT TABLE --************************************************************************ seltTestInputTable OBJECT-TYPE SYNTAX SEQUENCE OF SeltTestInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the input parameters for the SELT test." ::= { peaTestIpDslamObjects 1 } seltTestInputEntry OBJECT-TYPE SYNTAX SeltTestInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains input parameters for the SELT test for the subscriber line identified by lineIndex." INDEX {lineIndex } ::= { seltTestInputTable 1 } SeltTestInputEntry ::= SEQUENCE { seltNoiseNeAct INTEGER, seltNoiseFeAct INTEGER, seltAdvOutputTableAct INTEGER, --seltDcNoiseAct --seltImpedanceAct --seltWaterIngAct --seltNoiseDuration seltToneProfile INTEGER, seltVop Unsigned32, seltUsToneMask OCTET STRING, seltDsToneMask OCTET STRING, seltUsTransmitLevel Integer32, seltDsTransmitLevel Integer32, seltExtSplitterType INTEGER } seltNoiseNeAct OBJECT-TYPE SYNTAX INTEGER {activated (1), deactivated(0)} MAX-ACCESS read-write STATUS current DESCRIPTION "Value that indicates if Near-end noise should be measured or pre-selected. If the noise should be measured this should be Activated(1). If the noise should be pre-selected seltNoiseNeAct should be set to Deactivated(0)." ::= { seltTestInputEntry 1 } seltNoiseFeAct OBJECT-TYPE SYNTAX INTEGER {activated (1), deactivated(0)} MAX-ACCESS read-write STATUS current DESCRIPTION "Value that indicates if Far-end noise should be measured or pre-selected. If the noise should be measured this should be Activated(1). If the noise should be pre-selected seltNoiseFeAct should be set to Deactivated(0)." ::= { seltTestInputEntry 2 } seltAdvOutputTableAct OBJECT-TYPE SYNTAX INTEGER {activated (1), deactivated(0)} MAX-ACCESS read-write STATUS current DESCRIPTION "Switch that activates presentation of tone information or deactivates it." ::= { seltTestInputEntry 3 } seltToneProfile OBJECT-TYPE SYNTAX INTEGER { ansit1413(0), etsi(1), g9921PotsNonOverlapped(2), g9921PotsOverlapped(3), g9921IsdnNonOverlapped (4), g9922PotsNonOverlapped (8), g9923AnnexA (13), g9923AnnexB (14), g9923AnnexJ (15), g9923ReAnnexAandL (16), g9923ReNarrowPsdAnnexAandL (17), g9925AnnexA(18), g9925AnnexB(19), g9925AnnexM(20), sadsl64(128) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tone profile for different system configurations. The unused values for this parameter are reserved for comming standards or future proprietary techniques." ::= { seltTestInputEntry 8 } seltVop OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "10 km per sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Velocity of propagation is the speed at which an electric signal passes through a cable." ::= { seltTestInputEntry 9 } seltUsToneMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Upstream active tones assumed in capacity estimation. Using single bits in integer set specific tones on /off. Total number of tones is 256." ::= { seltTestInputEntry 10 } seltDsToneMask OBJECT-TYPE SYNTAX OCTET STRING (SIZE (64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Downstream active tones assumed in capacity estimation. Using single bits in integer set specific tones on /off. Total number of tones is 512." ::= { seltTestInputEntry 11 } seltUsTransmitLevel OBJECT-TYPE SYNTAX Integer32 (-128..127) MAX-ACCESS read-write STATUS current DESCRIPTION "Upstream transmit level." ::= { seltTestInputEntry 12 } seltDsTransmitLevel OBJECT-TYPE SYNTAX Integer32 (-128..127) MAX-ACCESS read-write STATUS current DESCRIPTION "Downstream transmit level." ::= { seltTestInputEntry 13 } seltExtSplitterType OBJECT-TYPE SYNTAX INTEGER {noneOrPOTS (0), edf110i(1), edf324Ncd90127R1a(2), edf324EtsiNcd90130R1a(3), kroneIsdn(4)} MAX-ACCESS read-write STATUS current DESCRIPTION "External splitter filter type. This parameter is used to inform the SELT software about any installed external splitter filter. The SELT performance is affected by this parameter. The unused values for this parameter are reserved for coming external splitter types or future proprietary options." ::= { seltTestInputEntry 14 } --************************************************************************ -- SELT NOISE INPUT TABLE --************************************************************************ --seltNoiseInputTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SeltNoiseInputEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "This table provides aditional input parameters -- for the SELT test." -- ::= { peaTestIpDslamObjects 2 } -- --seltNoiseInputEntry OBJECT-TYPE -- SYNTAX SeltNoiseInputEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "An entry contains the aditional input parameters -- for the SELT test for the subscriber line -- identified by lineIndex." -- INDEX {lineIndex } -- ::= { seltNoiseInputTable 1 } -- --SeltNoiseInputEntry ::= -- SEQUENCE { -- lineIndex Unsigned32 -- seltNoiseInputNe OCTET STRING, -- seltNoiseInputFe OCTET STRING -- } --seltNoiseInputNe OBJECT-TYPE -- SYNTAX OCTET STRING (SIZE (512)) -- UNITS "Tenth dBm/Hz" -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Pre-defined noise vector for Near-end (ATU-C) upstream band." -- ::= { seltNoiseInputEntry 1 } --seltNoiseInputFe OBJECT-TYPE -- SYNTAX OCTET STRING (SIZE (512)) -- UNITS "Tenth dBm/Hz" -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Pre-defined noise vector for Far-end (ATU-R) downstream band." -- ::= { seltNoiseInputEntry 2 } --************************************************************************ -- SELT TEST BASIC OUTPUT TABLE --************************************************************************ seltTestBasicOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF SeltTestBasicOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the basic output parameters for the SELT test." ::= { peaTestIpDslamObjects 3 } seltTestBasicOutputEntry OBJECT-TYPE SYNTAX SeltTestBasicOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the basic output parameters for the SELT test for the subscriber line identified by lineIndex." INDEX {lineIndex } ::= { seltTestBasicOutputTable 1 } SeltTestBasicOutputEntry ::= SEQUENCE { seltLength Unsigned32, seltSingleAttVal Unsigned32, seltAdslDeployment INTEGER, seltTermination INTEGER, seltCapacityUs Unsigned32, seltCapacityDs Unsigned32, --seltBridgetap --seltLoadedCoil --seltImpedenceAGnd --seltImpedanceBGnd --seltImpedanceAB --seltWaterIng seltBasicReliability INTEGER, seltUSMeanNoiseLevel Integer32, seltDSMeanNoiseLevel Integer32, seltAttenLimit Unsigned32 } seltLength OBJECT-TYPE SYNTAX Unsigned32 (0..65535) UNITS "meter" MAX-ACCESS read-only STATUS current DESCRIPTION "Loop length to termination." ::= { seltTestBasicOutputEntry 1 } seltSingleAttVal OBJECT-TYPE SYNTAX Unsigned32 (0..1400) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Attenuation at 300kHz." ::= { seltTestBasicOutputEntry 2 } seltAdslDeployment OBJECT-TYPE SYNTAX INTEGER {possible (0), uncertain(1), notPossible(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Parameter indicating the possibility for ADSL deployment. A value of Possible(0) indicates that the tested loop is possible for ADSL Deployment, Uncertain(1) indicates that it might be possible but some uncertainties exist. A value of NotPossible(2) indicates that ADSL deployment is not possible on the tested loop. Decision is based on parameters calculated in the selt algorithm." ::= { seltTestBasicOutputEntry 3 } seltCapacityUs OBJECT-TYPE SYNTAX Unsigned32 UNITS "bit/sec" MAX-ACCESS read-only STATUS current DESCRIPTION "Total loop capacity in the upstream direction." ::= { seltTestBasicOutputEntry 4 } seltCapacityDs OBJECT-TYPE SYNTAX Unsigned32 UNITS "bit/sec" MAX-ACCESS read-only STATUS current DESCRIPTION "Total loop capacity in the downstream direction." ::= { seltTestBasicOutputEntry 5 } seltTermination OBJECT-TYPE SYNTAX INTEGER {open (0), short(1), matched(2), cpePowerOnAnnexA(3), cpePowerOnAnnexB(4), cpePowerOnAnnexC(5), unknown(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Loop termination at customer side. The values between 6 and 254 are to be defined." ::= { seltTestBasicOutputEntry 6 } seltBasicReliability OBJECT-TYPE SYNTAX INTEGER {reliable (0), modReliable(1), notRealiable(2), newMeasReq(3), unsupportedHw(4), shortLineReliable(5), cpeDetected(6)} MAX-ACCESS read-only STATUS current DESCRIPTION "Reliability of the parameters in the seltTestBasicOutputTable. The values between 7 and 255 are to be defined." ::= { seltTestBasicOutputEntry 7 } seltUSMeanNoiseLevel OBJECT-TYPE SYNTAX Integer32 (-1600..0) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "The mean US noise level present on the line seen from IPDSLAM." ::= { seltTestBasicOutputEntry 8 } seltDSMeanNoiseLevel OBJECT-TYPE SYNTAX Integer32 (-1600..0) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "The mean DS noise level present on the line seen from IPDSLAM." ::= { seltTestBasicOutputEntry 9 } seltAttenLimit OBJECT-TYPE SYNTAX Unsigned32 (0..100) UNITS "dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Reported maximum measurable/reliable attenuation @ 300 kHz." ::= { seltTestBasicOutputEntry 10 } --************************************************************************ -- SELT TEST ADVANCED OUTPUT TABLE --************************************************************************ seltTestAdvOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF SeltTestAdvOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the advanced output parameters for the SELT test." ::= { peaTestIpDslamObjects 4 } seltTestAdvOutputEntry OBJECT-TYPE SYNTAX SeltTestAdvOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the advanced output parameters for the SELT test for the subscriber line identified by lineIndex." INDEX {lineIndex } ::= { seltTestAdvOutputTable 1 } SeltTestAdvOutputEntry ::= SEQUENCE { --seltAdvReliability --seltDcNoiseActFlag seltEcho0 OCTET STRING, seltEcho1 OCTET STRING, seltEcho2 OCTET STRING, seltEcho3 OCTET STRING, seltInsertionLoss0 OCTET STRING, seltInsertionLoss1 OCTET STRING, seltInsertionLoss2 OCTET STRING, seltInsertionLoss3 OCTET STRING, seltNoiseNe0 OCTET STRING, seltNoiseNe1 OCTET STRING, seltNoiseNe2 OCTET STRING, seltNoiseNe3 OCTET STRING, seltNoiseFe0 OCTET STRING, seltNoiseFe1 OCTET STRING, seltNoiseFe2 OCTET STRING, seltNoiseFe3 OCTET STRING, seltSnrNe0 OCTET STRING, seltSnrNe1 OCTET STRING, seltSnrNe2 OCTET STRING, seltSnrNe3 OCTET STRING, seltSnrFe0 OCTET STRING, seltSnrFe1 OCTET STRING, seltSnrFe2 OCTET STRING, seltSnrFe3 OCTET STRING, seltBitLoadingEstNe0 OCTET STRING, seltBitLoadingEstNe1 OCTET STRING, seltBitLoadingEstFe0 OCTET STRING, seltBitLoadingEstFe1 OCTET STRING, seltInsertionLoss4 OCTET STRING, seltInsertionLoss5 OCTET STRING, seltInsertionLoss6 OCTET STRING, seltInsertionLoss7 OCTET STRING, seltNoiseFe4 OCTET STRING, seltNoiseFe5 OCTET STRING, seltNoiseFe6 OCTET STRING, seltNoiseFe7 OCTET STRING, seltSnrFe4 OCTET STRING, seltSnrFe5 OCTET STRING, seltSnrFe6 OCTET STRING, seltSnrFe7 OCTET STRING, seltBitLoadingEstFe2 OCTET STRING, seltBitLoadingEstFe3 OCTET STRING, seltTDR0 OCTET STRING, seltTDR1 OCTET STRING, seltTDR2 OCTET STRING, seltTDR3 OCTET STRING, seltTDR4 OCTET STRING, seltTDR5 OCTET STRING, seltTDR6 OCTET STRING, seltTDR7 OCTET STRING, seltInputImpedance0 OCTET STRING, seltInputImpedance1 OCTET STRING, seltInputImpedance2 OCTET STRING, seltInputImpedance3 OCTET STRING --seltDcNoiseNe --seltDcNoiseFe } seltEcho0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Magnitude of the Echo Frequency Response of the line. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 1 } seltEcho1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Magnitude of the Echo Frequency Response of the line. Part 1. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 2 } seltEcho2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Magnitude of the Echo Frequency Response of the line. Part 2. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 3 } seltEcho3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Magnitude of the Echo Frequency Response of the line. Part 3. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 4 } seltInsertionLoss0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 5 } seltInsertionLoss1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 6 } seltInsertionLoss2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 7 } seltInsertionLoss3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 8 } seltNoiseNe0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Near-end line noise per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 9 } seltNoiseNe1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Near-end line noise per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 10 } seltNoiseNe2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Near-end line noise per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 11 } seltNoiseNe3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Near-end line noise per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 12 } seltNoiseFe0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 13 } seltNoiseFe1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 14 } seltNoiseFe2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 15 } seltNoiseFe3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 16 } seltSnrNe0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 17 } seltSnrNe1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 18 } seltSnrNe2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 19 } seltSnrNe3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 20 } seltSnrFe0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 21 } seltSnrFe1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 22 } seltSnrFe2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 23 } seltSnrFe3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 24 } seltBitLoadingEstNe0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "Bit" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimate of the maximum attainable load of bits per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 25 } seltBitLoadingEstNe1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "Bit" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimate of the maximum attainable load of bits per tone in Upstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 26 } seltBitLoadingEstFe0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "Bit" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimate of the maximum attainable load of bits per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 27 } seltBitLoadingEstFe1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "Bit" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimate of the maximum attainable load of bits per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 28 } seltInsertionLoss4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 29 } seltInsertionLoss5 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 30 } seltInsertionLoss6 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 31 } seltInsertionLoss7 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Line Insertion loss (attenuation) per tone. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 32 } seltNoiseFe4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 33 } seltNoiseFe5 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 34 } seltNoiseFe6 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 35 } seltNoiseFe7 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end line noise per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 36 } seltSnrFe4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 37 } seltSnrFe5 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 38 } seltSnrFe6 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 39 } seltSnrFe7 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal to Noise ration per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 40 } seltBitLoadingEstFe2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "Bit" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimate of the maximum attainable load of bits per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 41 } seltBitLoadingEstFe3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "Bit" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimate of the maximum attainable load of bits per tone in Downstream band. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 42 } seltTDR0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be interpretated in a length unit equal to [x meter], where x = 0.5*seltVop*10000*1/(1024*4312.5) corresponding to an one-way physical length fraction. seltVop is read/write available via seltTestInputEntry. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 43 } seltTDR1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be interpretated in a length unit equal to [x meter], where x = 0.5*seltVop*10000*1/(1024*4312.5) corresponding to an one-way physical length fraction. seltVop is read/write available via seltTestInputEntry. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 44 } seltTDR2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be interpretated in a length unit equal to [x meter], where x = 0.5*seltVop*10000*1/(1024*4312.5) corresponding to an one-way physical length fraction. seltVop is read/write available via seltTestInputEntry. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 45 } seltTDR3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be interpretated in a length unit equal to [x meter], where x = 0.5*seltVop*10000*1/(1024*4312.5) corresponding to an one-way physical length fraction. seltVop is read/write available via seltTestInputEntry. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 46 } seltTDR4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be interpretated in a length unit equal to [x meter], where x = 0.5*seltVop*10000*1/(1024*4312.5) corresponding to an one-way physical length fraction. seltVop is read/write available via seltTestInputEntry. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 47 } seltTDR5 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be interpretated in a length unit equal to [x meter], where x = 0.5*seltVop*10000*1/(1024*4312.5) corresponding to an one-way physical length fraction. seltVop is read/write available via seltTestInputEntry. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 48 } seltTDR6 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be interpretated in a length unit equal to [x meter], where x = 0.5*seltVop*10000*1/(1024*4312.5) corresponding to an one-way physical length fraction. seltVop is read/write available via seltTestInputEntry. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 49 } seltTDR7 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Time Domain Reflectometry (TDR) impulse diagram equivalent. Part 0. Consecutive values are spaced 1/(1024*4312.5) seconds in time. The value spacing can be interpretated in a length unit equal to [x meter], where x = 0.5*seltVop*10000*1/(1024*4312.5) corresponding to an one-way physical length fraction. seltVop is read/write available via seltTestInputEntry. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 50 } seltInputImpedance0 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimated input impedance of the line including far-end termination. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 51 } seltInputImpedance1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimated input impedance of the line including far-end termination. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 52 } seltInputImpedance2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimated input impedance of the line including far-end termination. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 53 } seltInputImpedance3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) UNITS "tenth Ohm" MAX-ACCESS read-only STATUS current DESCRIPTION "Estimated input impedance of the line including far-end termination. Part 0. Consecutive values are spaced 4.3125 kHz in frequency. If seltAdvOutputTableAct is deactivated the values should be ignored." ::= { seltTestAdvOutputEntry 54 } --************************************************************************ -- NOISE TEST INPUT TABLE --************************************************************************ --noiseTestInputTable OBJECT-TYPE -- SYNTAX SEQUENCE OF NoiseTestInputEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "This table provides the intput parameters -- for the NOISE test." -- ::= { peaTestIpDslamObjects 5 } --noiseTestInputEntry OBJECT-TYPE -- SYNTAX NoiseTestInputEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "An entry contains the input parameters -- for the NOISE test for the subscriber line -- identified by lineIndex." -- INDEX {lineIndex } -- ::= { noiseTestInputTable 1 } --NoiseTestInputEntry ::= -- SEQUENCE { --lineIndex Unsigned32, --noiseType --noiseDuration --noiseAmplitudeThres --noiseSpectrumThres --noiseHistogramMin --noiseHistogramMax --} --************************************************************************ -- NOISE TEST OUTPUT TABLE --************************************************************************ --noiseTestOutputTable OBJECT-TYPE -- SYNTAX SEQUENCE OF NoiseTestOutputEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "This table provides the output parameters -- for the NOISE test." -- ::= { peaTestIpDslamObjects 6 } --noiseTestOutputEntry OBJECT-TYPE -- SYNTAX NoiseTestOutputEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "An entry contains the output parameters -- for the NOISE test for the subscriber line -- identified by lineIndex." -- INDEX {lineIndex } -- ::= { noiseTestOutputTable 1 } --NoiseTestOutputEntry ::= -- SEQUENCE { --lineIndex Unsigned32, --noiseType --noiseAmplitude --noiseHistogram --noiseSpectrum --noiseNrViolations -- } --************************************************************************ -- ATM PVC TEST INPUT TABLE --************************************************************************ atmPvcTestInputTable OBJECT-TYPE SYNTAX SEQUENCE OF AtmPvcTestInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the input parameters for the ATM PVC test." ::= { peaTestIpDslamObjects 10 } atmPvcTestInputEntry OBJECT-TYPE SYNTAX AtmPvcTestInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains input parameters for the ATM PVC test for the subscriber line identified by lineIndex." INDEX {lineIndex } ::= { atmPvcTestInputTable 1 } AtmPvcTestInputEntry ::= SEQUENCE { atmF5EndToEndLoopbackInterval INTEGER, atmF5EndToEndLoopbackTimeout INTEGER, atmF5EndToEndLoopbackIntervalFine INTEGER, atmF5EndToEndBatchSize INTEGER, atmF5EndToEndBatchCount INTEGER } atmF5EndToEndLoopbackInterval OBJECT-TYPE SYNTAX INTEGER (0..3600) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "A number of 'ATM OAM F5 end-to-end loopback' cell(s) are sent with this interval on each PVC created for the subscriber line identified by lineIndex. The CPE must return a reply within atmF5EndToEndLoopbackTimeout seconds. The value zero indicates that this test is disabled. The first cell will be send when a non-zero value is written into this variable - or when the line is ready. If a resolution in msec is needed, use atmF5EndToEndLoopbackIntervalFine. Note: In order to restart a batch (if atmF5EndToEndBatchCount != 0) this parameter should be set to 0 and then set to the new (or possible) same interval. " ::= { atmPvcTestInputEntry 1 } atmF5EndToEndLoopbackTimeout OBJECT-TYPE SYNTAX INTEGER (1..10) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the the maximum amount of time to wait for F5 replies for a batch. (The batch size is set in atmF5EndToEndBatchSize) " ::= { atmPvcTestInputEntry 2 } atmF5EndToEndLoopbackIntervalFine OBJECT-TYPE SYNTAX INTEGER (100..3600000) UNITS "msec" MAX-ACCESS read-write STATUS current DESCRIPTION "A number of 'ATM OAM F5 end-to-end loopback' cell(s) are sent with this interval on each PVC created for the subscriber line identified by lineIndex. The CPE must return a reply within atmF5EndToEndLoopbackTimeout seconds. The value zero indicates that this test is disabled. The first cell will be send when a non-zero value is written into this variable - or when the line is ready. This parameter follows atmF5EndToEndLoopbackInterval with a finer resolution. Note: In order to restart a batch (if atmF5EndToEndBatchCount != 0) this parameter should be set to 0 and then set to the new (or possible) same interval. " ::= { atmPvcTestInputEntry 3 } atmF5EndToEndBatchSize OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies how many F5 cells that is be sent in an interval given by atmF5EndToEndLoopbackIntervalFine and atmF5EndToEndLoopbackInterval. " ::= { atmPvcTestInputEntry 5 } atmF5EndToEndBatchCount OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies how many batches that should be run before automatically stopping the test. Eg. A BatchCount of 4 and an interval of 3 seconds would run for 12 seconds and send a total of 20 F5 cells if BatchSize equals 5. Note: A BatchCount of 0 indicates that the test should run until it is stopped by setting interval to 0. " ::= { atmPvcTestInputEntry 6 } --************************************************************************ -- ATM PVC TEST OUTPUT TABLE --************************************************************************ atmPvcTestOutputTables OBJECT IDENTIFIER ::= { peaTestIpDslamObjects 12 } atmPvcTestOutputTableVpiIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The vpi index in atmPvcTestOutputTablePvc." ::= { atmPvcTestOutputTables 1 } atmPvcTestOutputTableVciIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The vci index in atmPvcTestOutputTablePvc." ::= { atmPvcTestOutputTables 2 } atmPvcTestOutputTableLine OBJECT-TYPE SYNTAX SEQUENCE OF AtmPvcTestOutputEntryLine MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the output parameters for the ATM PVC test (per line parameters). " ::= { atmPvcTestOutputTables 4 } atmPvcTestOutputEntryLine OBJECT-TYPE SYNTAX AtmPvcTestOutputEntryLine MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains output parameters for the ATM PVC test for the subscriber line identified by lineIndex. " INDEX {lineIndex} ::= { atmPvcTestOutputTableLine 1 } AtmPvcTestOutputEntryLine ::= SEQUENCE { atmF5EndToEndBatchesLeft Counter32 } atmF5EndToEndBatchesLeft OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "If batches are used (defined with atmF5EndToEndBatchCount != 0) This counter states how many batches are left before all batches have been run. " ::= { atmPvcTestOutputEntryLine 1 } atmPvcTestOutputTablePvc OBJECT-TYPE SYNTAX SEQUENCE OF AtmPvcTestOutputEntryPvc MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the output parameters for the ATM PVC test (per pvc parameters). " ::= { atmPvcTestOutputTables 6 } atmPvcTestOutputEntryPvc OBJECT-TYPE SYNTAX AtmPvcTestOutputEntryPvc MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains output parameters for the ATM PVC test for the subscriber PVC identified by lineIndex, atmPvcTestOutputTableVpiIndex, and atmPvcTestOutputTableVciIndex. " INDEX {lineIndex, atmPvcTestOutputTableVpiIndex, atmPvcTestOutputTableVciIndex } ::= { atmPvcTestOutputTablePvc 1 } AtmPvcTestOutputEntryPvc ::= SEQUENCE { atmF5EndToEndTransmitted Counter32, atmF5EndToEndReceived Counter32 } atmF5EndToEndTransmitted OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of F5 cells transmitted on the PVC since the test was started with atmF5EndToEndLoopbackIntervalFine or atmF5EndToEndLoopbackInterval. " ::= { atmPvcTestOutputEntryPvc 1 } atmF5EndToEndReceived OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of F5 cells received on the PVC since the test was started with atmF5EndToEndLoopbackIntervalFine or atmF5EndToEndLoopbackInterval. Note: F5 cells from a previous batch that are received are droped and are not counted here. (ie. very late answers arriving later than atmF5EndToEndLoopbackInterval(Fine) or atmF5EndToEndLoopbackTimeout - whichever are smallest - after transmission of the requests) " ::= { atmPvcTestOutputEntryPvc 2 } --************************************************************************ -- PPPoE TEST INPUT TABLE --************************************************************************ pppoeTestInputTable OBJECT-TYPE SYNTAX SEQUENCE OF PppoeTestInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the input parameters for the 'PPP-over-Ethernet' test. Note: This OID has to be specified in 'adslIfTestType' in order to activate the test. The test is a PADI packet broadcasted on the Ethernet (through the Bridge/Filter for this line). The test succeds when at least one 'Access Concentrator' server replies with a PADO packet. See description of result in pppoeTestOutputTable. The returned AC-Name & Service-Names from each PADO packet will be stored in pppoeTestOutputTable. Abbreviations: - PADI: PPPoE Active Discovery Initiation - PADO: PPPoE Active Discovery Offer - AC-Name: Access Concentrator Name See also: 'peaIfIpDslam.adslIffObjects.adslIfTestTable.adslIfTestEntry.adslIfTestType'" ::= { peaTestIpDslamObjects 20 } pppoeTestInputEntry OBJECT-TYPE SYNTAX PppoeTestInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains input parameters for the 'PPP-over-Ethernet' test for the subscriber line identified by lineIndex. See also summary in pppoeTestInputTable." INDEX {lineIndex } ::= { pppoeTestInputTable 1 } PppoeTestInputEntry ::= SEQUENCE { pppoeServiceRequested DisplayString, pppoeVlanId INTEGER, pppoeTimeout INTEGER, pppoeInnerVlanId INTEGER } pppoeServiceRequested OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The ServiceName used in the PADI packets (PPPoE Active Discovery Initiation) during PPPoE tests (default empty)." ::= { pppoeTestInputEntry 1 } pppoeVlanId OBJECT-TYPE SYNTAX INTEGER (0..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the VLANID used for the pppoeTest (accordingly to 802.1Q). The VLANID must have been configured for this line in the pvcTable. See also 'peaBridgeIpDslam.pvcTable.pvcEntry.pvcStatus.vlanID'" ::= { pppoeTestInputEntry 2 } pppoeTimeout OBJECT-TYPE SYNTAX INTEGER (1..10) UNITS "sec" MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the the maximum amount of time to wait from the PADI packet is broadcasted until all replies (PADI packets) must have arrived." ::= { pppoeTestInputEntry 3 } pppoeInnerVlanId OBJECT-TYPE SYNTAX INTEGER (0..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the InnerVlanId used for the pppoeTest (accordingly to 802.1Q). This object is valid only if vlanTagType value is QinQ (Double Vlan). The innerVlanId must have been configured for this line in the pvcTable. See also 'peaBridgeIpDslam.pvcTable.pvcEntry.pvcStatus.innerVlanId'" ::= { pppoeTestInputEntry 4 } --************************************************************************ -- PPPoE TEST OUTPUT TABLE --************************************************************************ pppoeTestOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF PppoeTestOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the **additional** output parameters for the 'PPP-over-Ethernet' test. The test result can be read in the generic 'adslIfTestResult' variable, which can have the following values: - InProgress - UnableToRun, details in adslIfTestError: +- lanError: The specified VLAN-id is not used by any ATM PVCs that belongs to specified line (or line down). +- configurationOrCustomisationError: Bridge does now allow PPPoE frames for the PVC with specified VLAN-id. +- softwareError: Internal error. - TestFailed, details in adslIfTestError: +- timeoutExpired: No PADO reply received See also: 'peaIfIpDslam.adslIfObjects.adslIfTestTable'" ::= { peaTestIpDslamObjects 21 } pppoeTestOutputEntry OBJECT-TYPE SYNTAX PppoeTestOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains **additional** output parameters for the 'PPP-over-Ethernet' test for the subscriber line identified by lineIndex. Zero or more entries may exists for each line." INDEX {lineIndex, resultIndex } ::= { pppoeTestOutputTable 1 } PppoeTestOutputEntry ::= SEQUENCE { resultIndex Unsigned32, pppoeAccessConcentrator DisplayString, pppoeServiceOffered DisplayString } pppoeAccessConcentrator OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the Access Concentrator reported in a PADO packet." ::= { pppoeTestOutputEntry 1 } pppoeServiceOffered OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of a Service reported in a PADO packet from the Access Concentrator." ::= { pppoeTestOutputEntry 2 } resultIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the entry number for a line." ::= { pppoeTestOutputEntry 3 } -- resultIndex is not included in the pppoeTestOutputEntry table. Thats why SMIC giving error. -- { peaTestIpDslamObjects 22 } --************************************************************************ -- LOOP DIAGNOSTICS RESULT TABLE --************************************************************************ loopDiagResultTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopDiagResultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the per line results of the ADSL2 Loop Diagnostics." ::= { peaTestIpDslamObjects 23 } loopDiagResultEntry OBJECT-TYPE SYNTAX LoopDiagResultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the per line results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex." INDEX {lineIndex } ::= { loopDiagResultTable 1 } LoopDiagResultEntry ::= SEQUENCE { loopDiagStatus INTEGER, loopDiagAttainableBitRateNE Unsigned32, loopDiagLoopAttenuationNE Unsigned32, loopDiagSignalAttenuationNE Unsigned32, loopDiagSnrMarginNE Integer32, loopDiagActualTxPowerFarEndNE Integer32, loopDiagAttainableBitRateFE Unsigned32, loopDiagLoopAttenuationFE Unsigned32, loopDiagSignalAttenuationFE Unsigned32, loopDiagSnrMarginFE Integer32, loopDiagActualTxPowerFarEndFE Integer32 } loopDiagStatus OBJECT-TYPE SYNTAX INTEGER {loopDiagNotStarted (0), loopDiagInProgress (1), loopDiagMeasOk (2), loopDiagSuccess (3), loopDiagFailed (4)} MAX-ACCESS read-only STATUS current DESCRIPTION "Status of current Loop Diagnostics. NOTE that Loop Diagnostics data are only valid in case of status LoopDiagSuccess." ::= { loopDiagResultEntry 1 } loopDiagAttainableBitRateNE OBJECT-TYPE SYNTAX Unsigned32 (0..32768000) UNITS "bps" MAX-ACCESS read-only STATUS current DESCRIPTION "Near-end attainable bit rate in bit per second (bps). Compliant to G.997.1: 7.5.1.13 (ATTNDRus)." ::= { loopDiagResultEntry 2 } loopDiagLoopAttenuationNE OBJECT-TYPE SYNTAX Unsigned32 (0..1023) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Near-end loop attenuation. Range is [1023..0], unit is 0.1 dB. LoopAttenuation = 1023 is a special value indicating that the loop attenuation is outside the represented range. Compliant to G.997.1: 7.5.1.7 (LATNus)." ::= { loopDiagResultEntry 3 } loopDiagSignalAttenuationNE OBJECT-TYPE SYNTAX Unsigned32 (0..1023) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Near-end signal attenuation. Range is [1023..0], unit is 0.1 dB. SignalAttenuation = 1023 is a special value indicating that the attenuation is outside the represented range. Compliant to G.997.1: 7.5.1.9 (SATNus)." ::= { loopDiagResultEntry 4 } loopDiagSnrMarginNE OBJECT-TYPE SYNTAX Integer32 (-512..511) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Near-end signal-to-noise ratio margin. Range is [511..-512], unit is 0.1 dB. snrMargin = -512 is a special value indicating that the signal-to-noise ratio margin is outside the represented range. Compliant to G.997.1: 7.5.1.11 (SNRMus)." ::= { loopDiagResultEntry 5 } loopDiagActualTxPowerFarEndNE OBJECT-TYPE SYNTAX Integer32 (-512..511) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end actual aggregate transmit power as determined by the near-end receive PMD function. Range is [511..-512], unit is 0.1 dBm. actualTxPowerFE = -512 is a special value indicating that the actual aggregate transmit power is outside the represented range. Compliant to G.997.1: 7.5.1.17 (ACTATPus)." ::= { loopDiagResultEntry 6 } loopDiagAttainableBitRateFE OBJECT-TYPE SYNTAX Unsigned32 (0..32768000) UNITS "bps" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end attainable bit rate in bit per second (bps). Compliant to G.997.1: 7.5.1.12 (ATTNDRds)." ::= { loopDiagResultEntry 7 } loopDiagLoopAttenuationFE OBJECT-TYPE SYNTAX Unsigned32 (0..1023) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end loop attenuation. Range is [1023..0], unit is 0.1 dB. LoopAttenuation = 1023 is a special value indicating that the attenuation is outside the represented range. Compliant to G.997.1: 7.5.1.6 (LATNds)." ::= { loopDiagResultEntry 8 } loopDiagSignalAttenuationFE OBJECT-TYPE SYNTAX Unsigned32 (0..1023) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end signal attenuation. Range is [1023..0], unit is 0.1 dB. SignalAttenuation = 1023 is a special value indicating that the attenuation is outside the represented range. Compliant to G.997.1: 7.5.1.8 (SATNds)." ::= { loopDiagResultEntry 9 } loopDiagSnrMarginFE OBJECT-TYPE SYNTAX Integer32 (-512..511) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Far-end signal-to-noise ratio margin. Range is [511..-512], unit is 0.1 dB. SnrMargin = -512 is a special value indicating that the signal-to-noise ratio margin is outside the represented range. Compliant to G.997.1: 7.5.1.10 (SNRMds)." ::= { loopDiagResultEntry 10 } loopDiagActualTxPowerFarEndFE OBJECT-TYPE SYNTAX Integer32 (-512..511) UNITS "tenth dB" MAX-ACCESS read-only STATUS current DESCRIPTION "The near-end actual aggregate transmit power as determined by the far-end receive PMD function. Range is [511..-512], unit is 0.1 dBm. ActualTxPowerFE = -512 is a special value indicating that the actual aggregate transmit power is outside the represented range. Compliant to G.997.1: 7.5.1.16 (ACTATPds)." ::= { loopDiagResultEntry 11 } --************************************************************************ -- LOOP DIAGNOSTICS HLIN NE (US) TABLE --************************************************************************ loopDiagHlinNeTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopDiagHlinNeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the per subcarrier Hlin results of the ADSL2 Loop Diagnostics. The linear complex channel transfer function values for the tone range specified by the partId. Hlin is calculated from the given values as follows: Hlin[i] = (HlinScale/215)*(Hlin[i].real + j*Hlin[i].imag)/215) Compliant to G.997.1: 7.5.1.18.5 (HLINSCus) and 7.5.1.18.6 (HLINpsus)." ::= { peaTestIpDslamObjects 24 } loopDiagHlinNeEntry OBJECT-TYPE SYNTAX LoopDiagHlinNeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the per subcarrier Hlin results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE Low designates the first 32 tones and High is the upper 32 tones for that particular partId." INDEX {lineIndex } ::= { loopDiagHlinNeTable 1 } LoopDiagHlinNeEntry ::= SEQUENCE { loopDiagHlinNeScale Unsigned32, loopDiagHlinNeLow OCTET STRING, loopDiagHlinNeHigh OCTET STRING } loopDiagHlinNeScale OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Scale factor for the normalized complex numbers Hlin." ::= { loopDiagHlinNeEntry 1 } loopDiagHlinNeLow OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Bytes n*4 + [0..1]: Real part (int16) Bytes n*4 + [2..3]: Imaginary part (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinNeEntry 2 } loopDiagHlinNeHigh OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Bytes n*4 + [0..1]: Real part (int16) Bytes n*4 + [2..3]: Imaginary part (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinNeEntry 3 } --************************************************************************ -- LOOP DIAGNOSTICS HLIN FE TABLE --************************************************************************ loopDiagHlinFeTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopDiagHlinFeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the per subcarrier Hlin results of the ADSL2 Loop Diagnostics. The linear complex channel transfer function values for the tone range specified by the partId. Hlin is calculated from the given values as follows: Hlin[i] = (HlinScale/2^15)*(Hlin[i].real + j*Hlin[i].imag)/2^15) Compliant to G.997.1: 7.5.1.18.1 (HLINSCds) and 7.5.1.18.2 (HLINpsds)." ::= { peaTestIpDslamObjects 25 } loopDiagHlinFeEntry OBJECT-TYPE SYNTAX LoopDiagHlinFeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the per subcarrier Hlin results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE: The partId specifies the section of the Hlin table to return. The Hlin values returned correspond to tones: partId * 64 to (partId * 64 + 63). PartId range is [0..7]. Low designates the first 32 tones and High is the upper 32 tones for that particular partId." INDEX {lineIndex } ::= { loopDiagHlinFeTable 1 } LoopDiagHlinFeEntry ::= SEQUENCE { loopDiagHlinFeScalePart0 Unsigned32, loopDiagHlinFeScalePart1 Unsigned32, loopDiagHlinFeScalePart2 Unsigned32, loopDiagHlinFeScalePart3 Unsigned32, loopDiagHlinFeScalePart4 Unsigned32, loopDiagHlinFeScalePart5 Unsigned32, loopDiagHlinFeScalePart6 Unsigned32, loopDiagHlinFeScalePart7 Unsigned32, loopDiagHlinFePart0Low OCTET STRING, loopDiagHlinFePart0High OCTET STRING, loopDiagHlinFePart1Low OCTET STRING, loopDiagHlinFePart1High OCTET STRING, loopDiagHlinFePart2Low OCTET STRING, loopDiagHlinFePart2High OCTET STRING, loopDiagHlinFePart3Low OCTET STRING, loopDiagHlinFePart3High OCTET STRING, loopDiagHlinFePart4Low OCTET STRING, loopDiagHlinFePart4High OCTET STRING, loopDiagHlinFePart5Low OCTET STRING, loopDiagHlinFePart5High OCTET STRING, loopDiagHlinFePart6Low OCTET STRING, loopDiagHlinFePart6High OCTET STRING, loopDiagHlinFePart7Low OCTET STRING, loopDiagHlinFePart7High OCTET STRING } loopDiagHlinFeScalePart0 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Scale factor for the normalized complex numbers Hlin." ::= { loopDiagHlinFeEntry 1 } loopDiagHlinFeScalePart1 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Scale factor for the normalized complex numbers Hlin." ::= { loopDiagHlinFeEntry 2 } loopDiagHlinFeScalePart2 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Scale factor for the normalized complex numbers Hlin." ::= { loopDiagHlinFeEntry 3 } loopDiagHlinFeScalePart3 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Scale factor for the normalized complex numbers Hlin." ::= { loopDiagHlinFeEntry 4 } loopDiagHlinFeScalePart4 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Scale factor for the normalized complex numbers Hlin." ::= { loopDiagHlinFeEntry 5 } loopDiagHlinFeScalePart5 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Scale factor for the normalized complex numbers Hlin." ::= { loopDiagHlinFeEntry 6 } loopDiagHlinFeScalePart6 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Scale factor for the normalized complex numbers Hlin." ::= { loopDiagHlinFeEntry 7 } loopDiagHlinFeScalePart7 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Scale factor for the normalized complex numbers Hlin." ::= { loopDiagHlinFeEntry 8 } loopDiagHlinFePart0Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 9 } loopDiagHlinFePart0High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 10 } loopDiagHlinFePart1Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 11 } loopDiagHlinFePart1High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 12 } loopDiagHlinFePart2Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 13 } loopDiagHlinFePart2High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 14 } loopDiagHlinFePart3Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 15 } loopDiagHlinFePart3High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 16 } loopDiagHlinFePart4Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 17 } loopDiagHlinFePart4High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 18 } loopDiagHlinFePart5Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 19 } loopDiagHlinFePart5High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 20 } loopDiagHlinFePart6Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 21 } loopDiagHlinFePart6High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 22 } loopDiagHlinFePart7Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 23 } loopDiagHlinFePart7High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The linear complex channel transfer function values for the tone range specified by the partId. Range is [32767..-32768]. Bytes n*4 + [0..1]: Real part(n) (int16) Bytes n*4 + [2..3]: Imaginary part(n) (int16) real[n] = imag[n] = -32768 indicates no measurement." ::= { loopDiagHlinFeEntry 24 } --************************************************************************ -- LOOP DIAGNOSTICS HLOG TABLE --************************************************************************ loopDiagHlogTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopDiagHlogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the per subcarrier Hlog results of the ADSL2 Loop Diagnostics. Hlog is calculated from the given values, as follows: Hlog[i] = 6 - hlogNE(i)/10(dB) and Hlog[i] = 6 - hlogFE(i)/10(dB) Compliant to G.997.1: 7.5.1.18.4 (HLOGpsds) and 7.5.1.18.8 (HLOGpsus)" ::= { peaTestIpDslamObjects 26 } loopDiagHlogEntry OBJECT-TYPE SYNTAX LoopDiagHlogEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the per subcarrier Hlog results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE: The partId specifies the section of the far-end (US) Hlog table to return. The hlog values returned correspond to tones partId * 128 to (partId * 128 + 127). PartId range is [3..0]. Low designates the first 64 tones and High is the upper 64 tones for that particular partId." INDEX {lineIndex } ::= { loopDiagHlogTable 1 } LoopDiagHlogEntry ::= SEQUENCE { loopDiagHlogNE OCTET STRING, loopDiagHlogFEPart0Low OCTET STRING, loopDiagHlogFEPart0High OCTET STRING, loopDiagHlogFEPart1Low OCTET STRING, loopDiagHlogFEPart1High OCTET STRING, loopDiagHlogFEPart2Low OCTET STRING, loopDiagHlogFEPart2High OCTET STRING, loopDiagHlogFEPart3Low OCTET STRING, loopDiagHlogFEPart3High OCTET STRING } loopDiagHlogNE OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The near-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: Hlog(n) (uint16)" ::= { loopDiagHlogEntry 1 } loopDiagHlogFEPart0Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: Hlog(n) (uint16)" ::= { loopDiagHlogEntry 2 } loopDiagHlogFEPart0High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: Hlog(n) (uint16)" ::= { loopDiagHlogEntry 3 } loopDiagHlogFEPart1Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: Hlog(n) (uint16)" ::= { loopDiagHlogEntry 4 } loopDiagHlogFEPart1High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: Hlog(n) (uint16)" ::= { loopDiagHlogEntry 5 } loopDiagHlogFEPart2Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: Hlog(n) (uint16)" ::= { loopDiagHlogEntry 6 } loopDiagHlogFEPart2High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: Hlog(n) (uint16)" ::= { loopDiagHlogEntry 7 } loopDiagHlogFEPart3Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: Hlog(n) (uint16)" ::= { loopDiagHlogEntry 8 } loopDiagHlogFEPart3High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end logarithmic scale channel transfer function magnitudes. Range is [1023..0]. The value 1023 indicates no measurement available. Bytes n*2 + [0..1]: Hlog(n) (uint16)" ::= { loopDiagHlogEntry 9 } --************************************************************************ -- LOOP DIAGNOSTICS QLN TABLE --************************************************************************ loopDiagQlnTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopDiagQlnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the per subcarrier Qln results of the ADSL2 Loop Diagnostics. QLN is calculated from the given values as follows: QLN[i] = -23 - (n[i]/2)(dBm/Hz), where n designates the QlnNE and QlnFE respectively. Compliant to G.997.1: 7.5.1.19.2 (QLNpsds) and 7.5.1.19.4 (QLNpsus)" ::= { peaTestIpDslamObjects 27 } loopDiagQlnEntry OBJECT-TYPE SYNTAX LoopDiagQlnEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the per subcarrier Qln results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE: The partId specifies the section of the far-end (US) QLN table to return. The QLN values returned correspond to tones partId * 256 to (partId * 256 + 255). PartId range is [1..0]. Low designates the first 128 tones and High is the upper 128 tones for that particular partId." INDEX {lineIndex } ::= { loopDiagQlnTable 1 } LoopDiagQlnEntry ::= SEQUENCE { loopDiagQlnNE OCTET STRING, loopDiagQlnFEPart0Low OCTET STRING, loopDiagQlnFEPart0High OCTET STRING, loopDiagQlnFEPart1Low OCTET STRING, loopDiagQlnFEPart1High OCTET STRING } loopDiagQlnNE OBJECT-TYPE SYNTAX OCTET STRING (SIZE (64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The near-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagQlnEntry 1 } loopDiagQlnFEPart0Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagQlnEntry 2 } loopDiagQlnFEPart0High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagQlnEntry 3 } loopDiagQlnFEPart1Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagQlnEntry 4 } loopDiagQlnFEPart1High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end quiet line noise PSD. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagQlnEntry 5 } --************************************************************************ -- LOOP DIAGNOSTICS SNR TABLE --************************************************************************ loopDiagSnrTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopDiagSnrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides the per subcarrier Snr results of the ADSL2 Loop Diagnostics. SNR is calculated from the given values as follows: SNR[i] = -32 + (n[i]/2)(dB) where n designates the SnrNE and SnrFE respectively. Compliant to G.997.1: 7.5.1.20.2 (SNRpsds) and 7.5.1.20.4 (SNRpsus)" ::= { peaTestIpDslamObjects 28 } loopDiagSnrEntry OBJECT-TYPE SYNTAX LoopDiagSnrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry contains the per subcarrier Snr results of the ADSL2 Loop Diagnostics for the subscriber line identified by lineIndex. NOTE: The partId specifies the section of the far-end (US) SNR table to return. The SNR values returned correspond to tones partId * 256 to (partId * 256 + 255). PartId range is [0..1]. Low designates the first 128 tones and High is the upper 128 tones for that particular partId." INDEX {lineIndex } ::= { loopDiagSnrTable 1 } LoopDiagSnrEntry ::= SEQUENCE { loopDiagSnrNE OCTET STRING, loopDiagSnrFEPart0Low OCTET STRING, loopDiagSnrFEPart0High OCTET STRING, loopDiagSnrFEPart1Low OCTET STRING, loopDiagSnrFEPart1High OCTET STRING } loopDiagSnrNE OBJECT-TYPE SYNTAX OCTET STRING (SIZE (64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The near-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagSnrEntry 1 } loopDiagSnrFEPart0Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagSnrEntry 2 } loopDiagSnrFEPart0High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagSnrEntry 3 } loopDiagSnrFEPart1Low OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagSnrEntry 4 } loopDiagSnrFEPart1High OBJECT-TYPE SYNTAX OCTET STRING (SIZE (128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The far-end signal-to-noise ratio. Range is [255..0]. The value 255 indicates no measurement available." ::= { loopDiagSnrEntry 5 } --************************************************************************ -- trap definitions --************************************************************************ peaTestIpDslamTrapsEntry OBJECT IDENTIFIER ::= { peaTestIpDslamTraps 0 } ifTestCompletion NOTIFICATION-TYPE OBJECTS { managedObjectClass, managedObjectInstance, sequenceNumber, perceivedSeverity, eventTime, eventTypePem, probableCause, adslIfTestResult, adslIfTestType, adslIfTestError } STATUS current DESCRIPTION "Indicates that the test is ready. Valid from: EDA 1.1R2A Parameters 1: Managed object class IP DSLAM Port 2: Managed object ID (MAC + PortNo) 3: Sequence number (Alarm sequence number) 4: Perceived severity Warning 5: Event time (Timestamp is retrieved from a SNTP server) 6: Event type Equipment 7: Probable cause Other 8: Test Result (Success, NotSupported, UnableToRun, Aborted or Failed) 9: Test Type (Type of the test performed) 10: Test Error (Probable cause value) " --Ericsson Diax additional information: --Format: Test is ready from: $2; Probable cause: $7; TestResult: $8; TestType: $9; TestError: $10; Sequence Number: $3; ::= { peaTestIpDslamTrapsEntry 1 } peaTestIpDslamObjectsGroup OBJECT-GROUP OBJECTS { seltNoiseNeAct, seltNoiseFeAct, seltAdvOutputTableAct, seltToneProfile, seltVop, seltUsToneMask, seltDsToneMask, seltUsTransmitLevel, seltDsTransmitLevel, seltExtSplitterType, seltLength, seltSingleAttVal, seltAdslDeployment, seltTermination, seltCapacityUs, seltCapacityDs, seltBasicReliability, seltUSMeanNoiseLevel, seltDSMeanNoiseLevel, seltAttenLimit, seltEcho0, seltEcho1, seltEcho2, seltEcho3, seltInsertionLoss0, seltInsertionLoss1, seltInsertionLoss2, seltInsertionLoss3, seltNoiseNe0, seltNoiseNe1, seltNoiseNe2, seltNoiseNe3, seltNoiseFe0, seltNoiseFe1, seltNoiseFe2, seltNoiseFe3, seltSnrNe0, seltSnrNe1, seltSnrNe2, seltSnrNe3, seltSnrFe0, seltSnrFe1, seltSnrFe2, seltSnrFe3, seltBitLoadingEstNe0, seltBitLoadingEstNe1, seltBitLoadingEstFe0, seltBitLoadingEstFe1, seltInsertionLoss4, seltInsertionLoss5, seltInsertionLoss6, seltInsertionLoss7, seltNoiseFe4, seltNoiseFe5, seltNoiseFe6, seltNoiseFe7, seltSnrFe4, seltSnrFe5, seltSnrFe6, seltSnrFe7, seltBitLoadingEstFe2, seltBitLoadingEstFe3, seltTDR0, seltTDR1, seltTDR2, seltTDR3, seltTDR4, seltTDR5, seltTDR6, seltTDR7, seltInputImpedance0, seltInputImpedance1, seltInputImpedance2, seltInputImpedance3, atmF5EndToEndLoopbackInterval, atmF5EndToEndLoopbackTimeout, pppoeServiceRequested, pppoeVlanId, pppoeTimeout, pppoeInnerVlanId, pppoeAccessConcentrator, pppoeServiceOffered, loopDiagStatus, loopDiagAttainableBitRateNE, loopDiagLoopAttenuationNE, loopDiagSignalAttenuationNE, loopDiagSnrMarginNE, loopDiagActualTxPowerFarEndNE, loopDiagAttainableBitRateFE, loopDiagLoopAttenuationFE, loopDiagSignalAttenuationFE, loopDiagSnrMarginFE, loopDiagActualTxPowerFarEndFE, loopDiagHlinNeScale, loopDiagHlinNeLow, loopDiagHlinNeHigh, loopDiagHlinFeScalePart0, loopDiagHlinFeScalePart1, loopDiagHlinFeScalePart2, loopDiagHlinFeScalePart3 , loopDiagHlinFeScalePart4, loopDiagHlinFeScalePart5, loopDiagHlinFeScalePart6, loopDiagHlinFeScalePart7, loopDiagHlinFePart0Low, loopDiagHlinFePart0High, loopDiagHlinFePart1Low, loopDiagHlinFePart1High, loopDiagHlinFePart2Low, loopDiagHlinFePart2High, loopDiagHlinFePart3Low, loopDiagHlinFePart3High, loopDiagHlinFePart4Low, loopDiagHlinFePart4High, loopDiagHlinFePart5Low, loopDiagHlinFePart5High, loopDiagHlinFePart6Low, loopDiagHlinFePart6High, loopDiagHlinFePart7Low, loopDiagHlinFePart7High, loopDiagHlogNE, loopDiagHlogFEPart0Low, loopDiagHlogFEPart0High, loopDiagHlogFEPart1Low, loopDiagHlogFEPart1High, loopDiagHlogFEPart2Low, loopDiagHlogFEPart2High, loopDiagHlogFEPart3Low, loopDiagHlogFEPart3High, loopDiagQlnNE, loopDiagQlnFEPart0Low, loopDiagQlnFEPart0High, loopDiagQlnFEPart1Low, loopDiagQlnFEPart1High, loopDiagSnrNE, loopDiagSnrFEPart0Low, loopDiagSnrFEPart0High, loopDiagSnrFEPart1Low, loopDiagSnrFEPart1High } STATUS current DESCRIPTION "Objects for the fssServiceLine Group" ::= { peaTestIpDslamObjectsGroups 1 } peaTestIpDslamTrapsGroup NOTIFICATION-GROUP NOTIFICATIONS { ifTestCompletion } STATUS current DESCRIPTION "Deprecated Notifications Group" ::= { peaTestIpDslamTrapsGroups 2 } END