drrvalueTrippointMode

Module: OMNI-gx2drr3x-MIB

OID (symbolic): OMNI-gx2drr3x-MIB::drrvalueTrippointMode

OID (numeric): 1.3.6.1.4.1.1166.6.1.2.13.3.2.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The value of this object is the current value of trip point mode. There are three possible value: 1-off, 2-alarm_only, 3-alarm&switch.

If module input optical power is higher than the preset trippoint value, no operational difference for these three modes.

If module input optical power is less than the preset trippoint value, 1) When trippoint mode is OFF, no trippoint alarm will be generated and RF output impedance will stay normal as low. 2) When tripoint mode is ALARM_ONLY, trip_point alarm will be generated when the input optical power lower than the preset trippoint level but RF output impedance will stay normal as low. 3) When trippoint mode is ALARM_SWITCH, trip point alarm will be generated and RF output impedance will switch to abnorml as high impedance

What is drrvalueTrippointMode?

Read-write control that selects the trip point behavior: off(1) disables trip point alarming entirely; alarmOnly(2) raises an alarm when input optical power falls below the configured trip point level but keeps RF output impedance normal; alarm-and-Switch(3) both raises the alarm and switches RF output to high impedance. An admin sets this to control failover behavior on low optical signal.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.13.3.2.4
snmpwalk -v2c -c public <target> OMNI-gx2drr3x-MIB::drrvalueTrippointMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.13.3.2.4.1
snmpget -v2c -c public <target> OMNI-gx2drr3x-MIB::drrvalueTrippointMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1166.6.1.2.13.3.2.4.1 i <value>

Start monitoring General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRR3X triple return receiver module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2drr3x-MIB::drrvalueTrippointMode OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend/optical node (GX2 DRR3X triple return receiver module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1166giBCS-IDENT-MIB
1.3.6.1.4.1.1166.6motproxiesBCS-IDENT-MIB
1.3.6.1.4.1.1166.6.1hfcGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2hfcDevicesGX2HFC-MIB
1.3.6.1.4.1.1166.6.1.2.13gx2Drr3xGX2HFC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1166.6.1.2.13.3gx2drr3xDigitalTableOMNI-gx2drr3x-MIB
1.3.6.1.4.1.1166.6.1.2.13.3.2gx2drr3xDigitalEntryOMNI-gx2drr3x-MIB
1.3.6.1.4.1.1166.6.1.2.13.3.2.4drrvalueTrippointModeOMNI-gx2drr3x-MIB