Novell-LANalyzer-TR-MIB :: tokenRingOrderFrequencyErrors

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Novell-LANalyzer-TR-MIB › tokenRingOrderFrequencyErrors

tokenRingOrderFrequencyErrors

Module: Novell-LANalyzer-TR-MIB

OID (symbolic): Novell-LANalyzer-TR-MIB::tokenRingOrderFrequencyErrors

OID (numeric): 1.3.6.1.4.1.23.2.15.3.4.1.28

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: The number of frequency errors reported to the Ring Error Monitor. Frequency error indicates that a station detects that the frequency of the incoming signal differs by more than the standard specified margin. Frequency error is non-isolated error. It is a type 3 error and will cause the detect station initiating monitor contention process.

What is tokenRingOrderFrequencyErrors?

Identical in definition to tokenRingHostFrequencyErrors in the host table -- the MIB's DESCRIPTION text for this object is copied verbatim from that host-table entry -- but reported here in the order table, which is keyed and sorted by each station's ring position instead of by MAC address.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.23.2.15.3.4.1.28
snmpwalk -v2c -c public <target> Novell-LANalyzer-TR-MIB::tokenRingOrderFrequencyErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.23.2.15.3.4.1.28.1
snmpget -v2c -c public <target> Novell-LANalyzer-TR-MIB::tokenRingOrderFrequencyErrors.1

Start monitoring Novell LANalyzer network probe/analyzer (Token Ring segment statistics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Novell-LANalyzer-TR-MIB::tokenRingOrderFrequencyErrors OID value, configure state conditions and alerts, and monitor any Novell LANalyzer network probe/analyzer (Token Ring segment statistics) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.23excelanCMU-MIB
1.3.6.1.4.1.23.2genericGroupFASTPATH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.23.2.15ringrmon_mibNovell-LANalyzer-TR-MIB
1.3.6.1.4.1.23.2.15.3tokenRingNovell-LANalyzer-TR-MIB
1.3.6.1.4.1.23.2.15.3.4tokenRingOrderTableNovell-LANalyzer-TR-MIB
1.3.6.1.4.1.23.2.15.3.4.1tokenRingOrderEntryNovell-LANalyzer-TR-MIB
1.3.6.1.4.1.23.2.15.3.4.1.28tokenRingOrderFrequencyErrorsNovell-LANalyzer-TR-MIB