All MIBs › Nortel-MsCarrier-MscPassport-AtmIispMIB › mscAtmIfIispSigAddressConversion
mscAtmIfIispSigAddressConversion
Module: Nortel-MsCarrier-MscPassport-AtmIispMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-AtmIispMIB::mscAtmIfIispSigAddressConversion
OID (numeric): 1.3.6.1.4.1.562.36.2.1.114.7.3.10.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute specifies the address conversion on the outgoing signalling PDUs. The options are none, nativeE164, or nsap. The none option is the default and if this option is chosen then nothing is done to the address information element (IE) in the outgoing signalling message. If nativeE164 option is chosen, then only NSAP encapsulated E.164 addresses with zeros in the ESI are converted to native E.164 format in the outgoing signalling message. If the NSAP address is not encapsulated E.164 or the ESI field is not zeros and the nativeE164 option is chosen, then the call is cleared. If the nsap option is chosen, then native E.164 addresses are converted to NSAP E.164 with zeros in the ESI field; otherwise the address is in NSAP format and is not changed.
What is mscAtmIfIispSigAddressConversion?
Controls address-format conversion applied to outgoing signalling messages: none (leave the address IE untouched, the default), nativeE164 (convert NSAP-encapsulated E.164 addresses with a zero ESI to native E.164 format, clearing the call if the address doesn't qualify), or nsap (convert native E.164 addresses to NSAP-encapsulated E.164 format). Set this to match whatever address format the peer switch expects.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.7.3.10.1.2 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmIispMIB::mscAtmIfIispSigAddressConversion
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.114.7.3.10.1.2.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-AtmIispMIB::mscAtmIfIispSigAddressConversion.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.114.7.3.10.1.2.1 i <value>
Start monitoring Nortel MSC Passport ATM switch (IISP inter-switch signaling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-AtmIispMIB::mscAtmIfIispSigAddressConversion OID value, configure state conditions and alerts, and monitor any Nortel MSC Passport ATM switch (IISP inter-switch signaling) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.114 | mscAtmIf | Nortel-MsCarrier-MscPassport-AtmCoreMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.114.7 | mscAtmIfIisp | Nortel-MsCarrier-MscPassport-AtmIispMIB |
| 1.3.6.1.4.1.562.36.2.1.114.7.3 | mscAtmIfIispSig | Nortel-MsCarrier-MscPassport-AtmIispMIB |
| 1.3.6.1.4.1.562.36.2.1.114.7.3.10 | mscAtmIfIispSigProvTable | Nortel-MsCarrier-MscPassport-AtmIispMIB |
| 1.3.6.1.4.1.562.36.2.1.114.7.3.10.1 | mscAtmIfIispSigProvEntry | Nortel-MsCarrier-MscPassport-AtmIispMIB |
| 1.3.6.1.4.1.562.36.2.1.114.7.3.10.1.2 | mscAtmIfIispSigAddressConversion | Nortel-MsCarrier-MscPassport-AtmIispMIB |