Nortel-MsCarrier-MscPassport-AtmIispMIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 mscPassportMIBs FROM Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB Counter32, DisplayString, StorageType, RowStatus, Gauge32, Integer32, Unsigned32 FROM Nortel-MsCarrier-MscPassport-StandardTextualConventionsMIB Hex, NonReplicated, HexString, AsciiStringIndex FROM Nortel-MsCarrier-MscPassport-TextualConventionsMIB mscAtmIf, mscAtmIfVptIndex, mscAtmIfVpt, mscAtmIfIndex FROM Nortel-MsCarrier-MscPassport-AtmCoreMIB; -- LAST-UPDATED "9909010000Z" -- ORGANIZATION "Nortel Networks" -- CONTACT-INFO " -- Nortel Carrier Data Network Management -- -- Postal: P.O. Box 3511, Station C -- Ottawa, Ontario -- Canada K1Y 4H7 -- -- via the WEB: http://www.nortelnetworks.com -- select 'Contact Us' from the menu -- -- via phone: 1-800-4NORTEL" -- DESCRIPTION -- "The module describing the Nortel MsCarrier MscPassport -- AtmIisp Enterprise MIB." atmIispMIB OBJECT IDENTIFIER ::= { mscPassportMIBs 70 } -- AtmIf/n Iisp -- This component represents an ATM Interim Inter-switch Signaling -- Protocol (IISP) interface. If this component is provisioned, the Uni -- component can not be provisioned under the same AtmIf -- component. If this component is deleted, then all associated Vcc -- components are deleted. mscAtmIfIisp OBJECT IDENTIFIER ::= { mscAtmIf 7 } mscAtmIfIispRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIisp components." ::= { mscAtmIfIisp 1 } mscAtmIfIispRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIisp component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex } ::= { mscAtmIfIispRowStatusTable 1 } MscAtmIfIispRowStatusEntry ::= SEQUENCE { mscAtmIfIispRowStatus RowStatus, mscAtmIfIispComponentName DisplayString, mscAtmIfIispStorageType StorageType, mscAtmIfIispIndex NonReplicated } mscAtmIfIispRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIisp components. These components can be added and deleted." ::= { mscAtmIfIispRowStatusEntry 1 } mscAtmIfIispComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispRowStatusEntry 2 } mscAtmIfIispStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIisp tables." ::= { mscAtmIfIispRowStatusEntry 4 } mscAtmIfIispIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfIisp tables." ::= { mscAtmIfIispRowStatusEntry 10 } mscAtmIfIispProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for the Iisp component." ::= { mscAtmIfIisp 10 } mscAtmIfIispProvEntry OBJECT-TYPE SYNTAX MscAtmIfIispProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispProvTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex } ::= { mscAtmIfIispProvTable 1 } MscAtmIfIispProvEntry ::= SEQUENCE { mscAtmIfIispVersion INTEGER, mscAtmIfIispSide INTEGER, mscAtmIfIispSoftPvcRetryPeriod Unsigned32, mscAtmIfIispSoftPvpAndPvcRetryPeriod Unsigned32, mscAtmIfIispSoftPvpAndPvcHoldOffTime Unsigned32 } mscAtmIfIispVersion OBJECT-TYPE SYNTAX INTEGER { iisp10Sig30(2), iisp10Sig31(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates which specification the IISP interface complies with. The options are iisp10Sig30 which refers to IISP version 1.0 with 3.0 signalling and iisp10Sig31 which refers to IISP version 1.0 with 3.1 signalling. If this attribute is changed, all switched Vcc components in this interface are cleared due to the fact that the two versions are incompatible." DEFVAL { iisp10Sig31 } ::= { mscAtmIfIispProvEntry 1 } mscAtmIfIispSide OBJECT-TYPE SYNTAX INTEGER { networkSide(0), userSide(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates which side the interface is, user or network." DEFVAL { networkSide } ::= { mscAtmIfIispProvEntry 2 } mscAtmIfIispSoftPvcRetryPeriod OBJECT-TYPE SYNTAX Unsigned32 (20..999999) ACCESS read-write STATUS obsolete DESCRIPTION "This attribute specifies the time to wait between call set up retries. The resolution is to the nearest 10 seconds. This attribute has been obsoleted and is replaced by the softPvpAndPvcRetryPeriod attribute." DEFVAL { 60 } ::= { mscAtmIfIispProvEntry 3 } mscAtmIfIispSoftPvpAndPvcRetryPeriod OBJECT-TYPE SYNTAX Unsigned32 (20..999999) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the time to wait between soft PVP or soft PVC call setup retries. The resolution is to the nearest 10 seconds." DEFVAL { 60 } ::= { mscAtmIfIispProvEntry 4 } mscAtmIfIispSoftPvpAndPvcHoldOffTime OBJECT-TYPE SYNTAX Unsigned32 (0 | 50..20000) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies how long to hold off retries following a release or the connection. The resolution is to the nearest 50 ms." DEFVAL { 0 } ::= { mscAtmIfIispProvEntry 5 } mscAtmIfIispAcctOptTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispAcctOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for accounting." ::= { mscAtmIfIisp 11 } mscAtmIfIispAcctOptEntry OBJECT-TYPE SYNTAX MscAtmIfIispAcctOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispAcctOptTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex } ::= { mscAtmIfIispAcctOptTable 1 } MscAtmIfIispAcctOptEntry ::= SEQUENCE { mscAtmIfIispAccountCollection OCTET STRING, mscAtmIfIispAccountConnectionType INTEGER, mscAtmIfIispAccountClass Unsigned32, mscAtmIfIispServiceExchange Unsigned32 } mscAtmIfIispAccountCollection OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is used to turn accounting on or off for SVC and SPVC connections. It also specifies the reason(s) for which accounting data is collected: billing, test, study, audit, or force. If the set of reasons is not empty then accounting records will be generated by this interface in the following situations: - on a TODA changeover if TODA is enabled; - every 12 hours (per connection) if TODA is disabled; - on every call clear (a call record with final cell counts). If none of the reasons is present, then accounting will be suppressed. The reason for collection is recorded in the accounting record, in the attribute callingCollectReason or calledCollectReason as appropriate. Description of bits: bill(0) test(1) study(2) audit(3) force(4)" ::= { mscAtmIfIispAcctOptEntry 1 } mscAtmIfIispAccountConnectionType OBJECT-TYPE SYNTAX INTEGER { origTerm(0), intermediate(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether accounting records generated by this interface should be marked as originating, terminating or intermediate. This attribute, in combination with the direction of the call, determines the value of attribute connPointType of the accounting record and may be used by downstream accounting processes to correlate the records. If the value is origTerm then records generated for incoming calls will be marked as originating and records generated for outgoing calls will be marked as terminating. If the value is intermediate then records generated for all calls will be marked as intermediate." DEFVAL { intermediate } ::= { mscAtmIfIispAcctOptEntry 2 } mscAtmIfIispAccountClass OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the accounting class associated with the interface. Its meaning is determined by the network operator. Its value is simply recorded in the accounting records generated by this interface, in the attribute callingServiceType or calledServiceType as appropriate." DEFVAL { 0 } ::= { mscAtmIfIispAcctOptEntry 3 } mscAtmIfIispServiceExchange OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the data service exchange associated with this interface. Its meaning is determined by the network operator. Its value is simply recorded in the accounting records generated by this interface, in the attribute callingDse or calledDse as appropriate." DEFVAL { 0 } ::= { mscAtmIfIispAcctOptEntry 4 } -- AtmIf/n Iisp Signalling -- AtmIf/n Uni Signalling -- AtmIf/n Pnni Signalling -- AtmIf/n Vpt/m Iisp Signalling -- AtmIf/n Vpt/m Uni Signalling -- AtmIf/n Vpt/m Pnni Signalling -- -- This component represents the signalling entities for the interface. mscAtmIfIispSig OBJECT IDENTIFIER ::= { mscAtmIfIisp 3 } mscAtmIfIispSigRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispSigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIispSig components." ::= { mscAtmIfIispSig 1 } mscAtmIfIispSigRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispSigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIispSig component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispSigIndex } ::= { mscAtmIfIispSigRowStatusTable 1 } MscAtmIfIispSigRowStatusEntry ::= SEQUENCE { mscAtmIfIispSigRowStatus RowStatus, mscAtmIfIispSigComponentName DisplayString, mscAtmIfIispSigStorageType StorageType, mscAtmIfIispSigIndex NonReplicated } mscAtmIfIispSigRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIispSig components. These components cannot be added nor deleted." ::= { mscAtmIfIispSigRowStatusEntry 1 } mscAtmIfIispSigComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispSigRowStatusEntry 2 } mscAtmIfIispSigStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIispSig tables." ::= { mscAtmIfIispSigRowStatusEntry 4 } mscAtmIfIispSigIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfIispSig tables." ::= { mscAtmIfIispSigRowStatusEntry 10 } mscAtmIfIispSigProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispSigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes for the Signalling component." ::= { mscAtmIfIispSig 10 } mscAtmIfIispSigProvEntry OBJECT-TYPE SYNTAX MscAtmIfIispSigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispSigProvTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispSigIndex } ::= { mscAtmIfIispSigProvTable 1 } MscAtmIfIispSigProvEntry ::= SEQUENCE { mscAtmIfIispSigVci Unsigned32, mscAtmIfIispSigAddressConversion INTEGER, mscAtmIfIispSigOperatingMode INTEGER } mscAtmIfIispSigVci OBJECT-TYPE SYNTAX Unsigned32 (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the signalling channel number." DEFVAL { 5 } ::= { mscAtmIfIispSigProvEntry 1 } mscAtmIfIispSigAddressConversion OBJECT-TYPE SYNTAX INTEGER { none(0), nativeE164(1), nsap(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the address conversion on the outgoing signalling PDUs. The options are none, nativeE164, or nsap. The none option is the default and if this option is chosen then nothing is done to the address information element (IE) in the outgoing signalling message. If nativeE164 option is chosen, then only NSAP encapsulated E.164 addresses with zeros in the ESI are converted to native E.164 format in the outgoing signalling message. If the NSAP address is not encapsulated E.164 or the ESI field is not zeros and the nativeE164 option is chosen, then the call is cleared. If the nsap option is chosen, then native E.164 addresses are converted to NSAP E.164 with zeros in the ESI field; otherwise the address is in NSAP format and is not changed." DEFVAL { none } ::= { mscAtmIfIispSigProvEntry 2 } mscAtmIfIispSigOperatingMode OBJECT-TYPE SYNTAX INTEGER { normal(0), provisionedOnly(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the operating mode of the signaling channel. provisionedOnly indicates that only SPVCs and SPVPs are supported on the interface and SVCs are not supported. This value is permitted only on UNI interfaces. normal indicates that SVCs, SPVCs, and SPVPs are supported on the interface." DEFVAL { normal } ::= { mscAtmIfIispSigProvEntry 3 } mscAtmIfIispSigStateTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispSigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide." ::= { mscAtmIfIispSig 11 } mscAtmIfIispSigStateEntry OBJECT-TYPE SYNTAX MscAtmIfIispSigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispSigStateTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispSigIndex } ::= { mscAtmIfIispSigStateTable 1 } MscAtmIfIispSigStateEntry ::= SEQUENCE { mscAtmIfIispSigAdminState INTEGER, mscAtmIfIispSigOperationalState INTEGER, mscAtmIfIispSigUsageState INTEGER } mscAtmIfIispSigAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component." DEFVAL { unlocked } ::= { mscAtmIfIispSigStateEntry 1 } mscAtmIfIispSigOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle." DEFVAL { disabled } ::= { mscAtmIfIispSigStateEntry 2 } mscAtmIfIispSigUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time." DEFVAL { idle } ::= { mscAtmIfIispSigStateEntry 3 } mscAtmIfIispSigOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispSigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute contains the operational attributes for the AtmSignalling component." ::= { mscAtmIfIispSig 12 } mscAtmIfIispSigOperEntry OBJECT-TYPE SYNTAX MscAtmIfIispSigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispSigOperTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispSigIndex } ::= { mscAtmIfIispSigOperTable 1 } MscAtmIfIispSigOperEntry ::= SEQUENCE { mscAtmIfIispSigLastTxCauseCode Unsigned32, mscAtmIfIispSigLastTxDiagCode Hex, mscAtmIfIispSigLastRxCauseCode Unsigned32, mscAtmIfIispSigLastRxDiagCode Hex } mscAtmIfIispSigLastTxCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the cause code in the last transmitted signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages." ::= { mscAtmIfIispSigOperEntry 1 } mscAtmIfIispSigLastTxDiagCode OBJECT-TYPE SYNTAX Hex (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last transmitted signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to 0." ::= { mscAtmIfIispSigOperEntry 2 } mscAtmIfIispSigLastRxCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the cause code in the last received signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages." ::= { mscAtmIfIispSigOperEntry 3 } mscAtmIfIispSigLastRxDiagCode OBJECT-TYPE SYNTAX Hex (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last received signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to 0." ::= { mscAtmIfIispSigOperEntry 4 } mscAtmIfIispSigStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispSigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the statistics associated with the AtmSignalling component." ::= { mscAtmIfIispSig 13 } mscAtmIfIispSigStatsEntry OBJECT-TYPE SYNTAX MscAtmIfIispSigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispSigStatsTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispSigIndex } ::= { mscAtmIfIispSigStatsTable 1 } MscAtmIfIispSigStatsEntry ::= SEQUENCE { mscAtmIfIispSigCurrentConnections Counter32, mscAtmIfIispSigPeakConnections Gauge32, mscAtmIfIispSigSuccessfulConnections Counter32, mscAtmIfIispSigFailedConnections Counter32, mscAtmIfIispSigTxPdus Counter32, mscAtmIfIispSigRxPdus Counter32, mscAtmIfIispSigCurrentPmpConnections Gauge32, mscAtmIfIispSigPeakPmpConnections Gauge32, mscAtmIfIispSigSuccessfulPmpConnections Counter32, mscAtmIfIispSigFailedPmpConnections Counter32, mscAtmIfIispSigNewCurrentConnections Gauge32 } mscAtmIfIispSigCurrentConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS obsolete DESCRIPTION "This attribute indicates the total number of currently active connections." ::= { mscAtmIfIispSigStatsEntry 1 } mscAtmIfIispSigPeakConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the high water mark of active point-to- point and point-to-multipoint connections." ::= { mscAtmIfIispSigStatsEntry 2 } mscAtmIfIispSigSuccessfulConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched point-to- point and point-to-multipoint connections that were successfully established. The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfIispSigStatsEntry 3 } mscAtmIfIispSigFailedConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched connections that were not successfully established.The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfIispSigStatsEntry 4 } mscAtmIfIispSigTxPdus OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of transmitted signalling PDUs.The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfIispSigStatsEntry 5 } mscAtmIfIispSigRxPdus OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of received signalling PDUs.The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfIispSigStatsEntry 6 } mscAtmIfIispSigCurrentPmpConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of currently active point-to- multipoint connections." ::= { mscAtmIfIispSigStatsEntry 7 } mscAtmIfIispSigPeakPmpConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the high water mark of active point-to- multipoint connections." ::= { mscAtmIfIispSigStatsEntry 8 } mscAtmIfIispSigSuccessfulPmpConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched point-to- multipoint connections that were successfully established. The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfIispSigStatsEntry 9 } mscAtmIfIispSigFailedPmpConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of switched point-to- multipoint connections that were not successfully established.The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfIispSigStatsEntry 10 } mscAtmIfIispSigNewCurrentConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the total number of currently active point-to- point and point-to-multipoint connections." ::= { mscAtmIfIispSigStatsEntry 11 } -- AtmIf/n Uni Sig VirtualChannelDescriptor -- AtmIf/n Uni Ilmi VirtualChannelDescriptor -- AtmIf/n Iisp Sig VirtualChannelDescriptor -- AtmIf/n Pnni Sig VirtualChannelDescriptor -- AtmIf/n Pnni Rcc VirtualChannelDescriptor -- AtmIf/n Vpt/m Uni Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Iisp Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Pnni Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Pnni Rcc VirtualChannelDescriptor -- -- This component contains the provisionable traffic parameters for a -- control channel (Sig, Ilmi or Rcc component). mscAtmIfIispSigVcd OBJECT IDENTIFIER ::= { mscAtmIfIispSig 2 } mscAtmIfIispSigVcdRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispSigVcdRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIispSigVcd components." ::= { mscAtmIfIispSigVcd 1 } mscAtmIfIispSigVcdRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispSigVcdRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIispSigVcd component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispSigIndex, mscAtmIfIispSigVcdIndex } ::= { mscAtmIfIispSigVcdRowStatusTable 1 } MscAtmIfIispSigVcdRowStatusEntry ::= SEQUENCE { mscAtmIfIispSigVcdRowStatus RowStatus, mscAtmIfIispSigVcdComponentName DisplayString, mscAtmIfIispSigVcdStorageType StorageType, mscAtmIfIispSigVcdIndex NonReplicated } mscAtmIfIispSigVcdRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIispSigVcd components. These components can be added and deleted." ::= { mscAtmIfIispSigVcdRowStatusEntry 1 } mscAtmIfIispSigVcdComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispSigVcdRowStatusEntry 2 } mscAtmIfIispSigVcdStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIispSigVcd tables." ::= { mscAtmIfIispSigVcdRowStatusEntry 4 } mscAtmIfIispSigVcdIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfIispSigVcd tables." ::= { mscAtmIfIispSigVcdRowStatusEntry 10 } mscAtmIfIispSigVcdProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispSigVcdProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable traffic attributes for a control channel." ::= { mscAtmIfIispSigVcd 10 } mscAtmIfIispSigVcdProvEntry OBJECT-TYPE SYNTAX MscAtmIfIispSigVcdProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispSigVcdProvTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispSigIndex, mscAtmIfIispSigVcdIndex } ::= { mscAtmIfIispSigVcdProvTable 1 } MscAtmIfIispSigVcdProvEntry ::= SEQUENCE { mscAtmIfIispSigVcdTrafficDescType INTEGER, mscAtmIfIispSigVcdAtmServiceCategory INTEGER, mscAtmIfIispSigVcdWeight Unsigned32, mscAtmIfIispSigVcdQosClass INTEGER, mscAtmIfIispSigVcdTrafficShaping INTEGER, mscAtmIfIispSigVcdUnshapedTransmitQueueing INTEGER, mscAtmIfIispSigVcdUsageParameterControl INTEGER } mscAtmIfIispSigVcdTrafficDescType OBJECT-TYPE SYNTAX INTEGER { n3(3), n6(6), n7(7), n8(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the type of traffic management which is applied to both the transmit and receive direction of this connection as defined in the ATM Forum. The trafficDescType determines the number and meaning of the parameters in the trafficDescParm attribute." DEFVAL { n6 } ::= { mscAtmIfIispSigVcdProvEntry 1 } mscAtmIfIispSigVcdAtmServiceCategory OBJECT-TYPE SYNTAX INTEGER { unspecifiedBitRate(0), constantBitRate(1), rtVariableBitRate(2), nrtVariableBitRate(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the ATM service category for both directions of the connection. The constantBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. The consistent availability of a fixed quantity of bandwidth is considered appropriate for CBR service. Cells which are delayed beyond the value specified by CellTransfer Delay are assumed to be of significantly reduce value to the application. The rtVariableBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. Sources are expected to transmit at a rate which varies with time. Equivalently, the source can be described as 'bursty'. Cells which are delayed beyond the value specified by CTD are assumed to be of significantly reduced value to the application. Real time VBR service may support statistical multiplexing of real time sources. The nrtVariableBitRate service category is intended for non-real time applications which have bursty traffic characteristics and which can be characterized in terms of a PCR, SCR, and MBS. For those cells which are transferred within the traffic contract, the application expects a low cell loss ratio. For all connections, it expects a bound on the mean cell transfer delay. Non-real time VBR service may support statistical multiplexing of connections. The unspecifiedBitRate service is intended for non-real time applications; that is, those not requiring tightly constrained delay and delay variation. UBR sources are expected to be bursty. UBR service supports a high degree of statistical multiplexing among sources. UBR service does not specify traffic related service guarantees. No numerical commitments are made with respect to the cell loss ratio experienced by a UBR connection, or as to the cell transfer delay experienced by cells on the connection." DEFVAL { rtVariableBitRate } ::= { mscAtmIfIispSigVcdProvEntry 3 } mscAtmIfIispSigVcdWeight OBJECT-TYPE SYNTAX Unsigned32 (0 | 1..4095 | 65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies an override for the weight of this unshaped connection. This attribute is ignored for shaped connections, for ABR connections, for connections on a CQC-based ATM FP and basic VPTs. When the value is set to sameAsCa, the weight is determined by the weight policy attribute under the CA service category component for all but standard VPT VCCs. For standard VPT VCCs, the weight is determined by the VCC's service category, when the value is set to sameAsCa. When this attribute is set to a value from 1 to 4095, that value is used for the weight policy of this connection relative to other connections. For all but standard VPT VCCs, weight policy determines the proportion of transit cell opportunities which are allocated to this connection, compared to other connections in the same service category. For standard VPT VCCs, weight policy determines the proportion of transmit cell opportunities which are allocated to this connection, compared to other connections associated with the VPT. When the value is set to upToQueueLimit, the weight policy is limited only by the txQueueLimit. VALUES ( 0 = upToQueueLimit 65535 = sameAsCa )" DEFVAL { 65535 } ::= { mscAtmIfIispSigVcdProvEntry 4 } mscAtmIfIispSigVcdQosClass OBJECT-TYPE SYNTAX INTEGER { n0(0), n1(1), n2(2), n3(3), n4(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the quality of service for both the forward and backward direction for this connection. Class 1 supports a QOS that meets Service Class A performance requirements (Circuit emulation, constant bit rate video). Class 2 supports a QOS that meets Service Class B performance requirements (Variable bit rate audio and video). Class 3 supports a QOS that meets Service Class C performance requirements (Connection-Oriented Data Transfer). Class 4 supports a QOS that meets Service Class D performance requirements (Connectionless Data Transfer). Class 0 is the unspecified bit rate QOS class; no objective is specified for the performance parameters." DEFVAL { n2 } ::= { mscAtmIfIispSigVcdProvEntry 21 } mscAtmIfIispSigVcdTrafficShaping OBJECT-TYPE SYNTAX INTEGER { disabled(1), sameAsCa(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether this connection uses traffic shaping when transmitting traffic to the ATM interface. When sameAsCa is selected, traffic shaping for this connection is based on the trafficShaping attribute of the connection's service category component under the AtmIf CA. If the service category has traffic shaping enabled, then traffic shaping is enabled for the connection. Note that enabling traffic shaping may have no effect under certain cases. These cases are listed in the description of the trafficShaping operational attribute, which is under the Vcc Tm and Vpc Tm components. When disabled is selected, traffic shaping for this connection is disabled." DEFVAL { disabled } ::= { mscAtmIfIispSigVcdProvEntry 50 } mscAtmIfIispSigVcdUnshapedTransmitQueueing OBJECT-TYPE SYNTAX INTEGER { common(1), sameAsCa(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute only applies when this connection is unshaped. This attribute specifies the transmit queueing method for this connection if it is unshaped. Refer to the unshapedTransmitQueueing attribute under the AtmIf CA service category subcomponent for more details on the meaning of this attribute. When this attribute is set to sameAsCa, the transmit queueing method for the connection is based on the unshapedTransmitQueueing attribute of the connection's service category component under the ConnectionAdministrator. When this attribute is set to common, transmit traffic on this unshaped connection is destined for the common queue. The value sameAsInterface is for migration from previous software releases, but should no longer be used" DEFVAL { sameAsCa } ::= { mscAtmIfIispSigVcdProvEntry 60 } mscAtmIfIispSigVcdUsageParameterControl OBJECT-TYPE SYNTAX INTEGER { disabled(1), sameAsCa(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether this connection enforces usage parameter control when receiving traffic from the ATM interface. When sameAsCa is selected, UPC for the connection is based on the usageParameterControl attribute of the connection's service category component under the ConnectionAdministrator. If the service category has UPC enabled, then UPC is enabled for the connection. Note that enabling UPC may have no effect under certain cases. These cases are listed in the description of the usageParameterControl operational attribute, which is under the Vcc Tm or Vpc Tm component. When disabled is selected, UPC for this connection is disabled. The value sameAsInterface is for migration from previous software releases, but should no longer be used" DEFVAL { disabled } ::= { mscAtmIfIispSigVcdProvEntry 70 } mscAtmIfIispSigVcdTdpTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispSigVcdTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute is a vector of five traffic parameters whose meanings are defined by the trafficDescType attribute. The values of peak cell rate (PCR), sustained cell rate (SCR) and requested shaping rate are expressed in cell/s. Maximum burst size (MBS) is expressed in cells. CDVT is expressed in microseconds. The values of PCR, SCR, MBS and CDVT are used for connection admission control (CAC). The value of CDVT is only used for connections where the atmServiceCategory is constantBitRate. For all other values of atmServiceCategory, CDVT is ignored. The values of PCR, SCR and requested shaping rate are used to determine the actual shaping rate where traffic shaping is enabled. When trafficDescType is 3, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameter 1 must be non-zero. Parameters 2 and 3 must be zero. When trafficDescType is 6, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 and 1 traffic; parameter 3 represents the MBS for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. When trafficDescType is 7, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 with cell discard; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. When trafficDescType is 8, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 traffic with cell tagging; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. Whenever it is valid for PCR to be specified, parameter 5 may also be used to specify a requested shaping rate. A non-zero value in parameter 5 overrides the value in parameter 1 and is used as the peak cell rate in calculations of CAC and shaping rate. For trafficDescType 3 the traffic is shaped at the next rate less than the PCR. For trafficDescType 6, 7, and 8, the traffic is shaped at the highest available rate which is between PCR and SCR. However, if there is no available shaping rate between PCR and SCR, traffic is shaped at the next rate above the PCR." ::= { mscAtmIfIispSigVcd 387 } mscAtmIfIispSigVcdTdpEntry OBJECT-TYPE SYNTAX MscAtmIfIispSigVcdTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispSigVcdTdpTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispSigIndex, mscAtmIfIispSigVcdIndex, mscAtmIfIispSigVcdTdpIndex } ::= { mscAtmIfIispSigVcdTdpTable 1 } MscAtmIfIispSigVcdTdpEntry ::= SEQUENCE { mscAtmIfIispSigVcdTdpIndex Integer32, mscAtmIfIispSigVcdTdpValue Unsigned32 } mscAtmIfIispSigVcdTdpIndex OBJECT-TYPE SYNTAX Integer32 (1..5) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the mscAtmIfIispSigVcdTdpTable specific index for the mscAtmIfIispSigVcdTdpTable." ::= { mscAtmIfIispSigVcdTdpEntry 1 } mscAtmIfIispSigVcdTdpValue OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the mscAtmIfIispSigVcdTdpTable." ::= { mscAtmIfIispSigVcdTdpEntry 2 } -- AtmIf/n Iisp Address/address,type -- AtmIf/n Uni Address/address,type -- AtmIf/n Pnni Address/address,type -- AtmIf/n Vpt/m Iisp Address/address,type -- AtmIf/n Vpt/m Uni Address/address,type -- AtmIf/n Vpt/m Pnni Address/address,type -- -- This component represents an address (dynamic or static) -- associated with the interface. The index is a string of 1 to 40 hex -- digits or a single wildcard ('?'), and a type. The type identifies -- whether the Address component is for a primary, alternate, -- registered, or default address. -- -- The types primary and alternate are used for provisioned addresses. -- The type registered is used for dynamic addresses registered -- through ILMI. The type default is used for Soft PVP and Soft PVC -- addresses.Virtual interfaces do not have addresses of -- type default. -- -- The wildcard is only valid for provisioned addresses. If the address -- is a single wildcard, then that indicates that the interface supports -- all addresses. If there is no better match, then this interface may be -- chosen in the routing. If there is more than one interface with a -- single wildcard static address, then the choice is driven through a -- round robin algorithm. -- -- The round robin algorithm tries the primary routes and then the -- alternate routes if none of the primary routes succeed. -- If this node participates in a PNNI hierarchy, then a PnniInfo -- subcomponent can be provisioned under the AtmAddress -- component to specify the level to which this address will be -- advertised. mscAtmIfIispAddr OBJECT IDENTIFIER ::= { mscAtmIfIisp 4 } mscAtmIfIispAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIispAddr components." ::= { mscAtmIfIispAddr 1 } mscAtmIfIispAddrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIispAddr component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispAddrAddressIndex, mscAtmIfIispAddrAddressTypeIndex } ::= { mscAtmIfIispAddrRowStatusTable 1 } MscAtmIfIispAddrRowStatusEntry ::= SEQUENCE { mscAtmIfIispAddrRowStatus RowStatus, mscAtmIfIispAddrComponentName DisplayString, mscAtmIfIispAddrStorageType StorageType, mscAtmIfIispAddrAddressIndex AsciiStringIndex, mscAtmIfIispAddrAddressTypeIndex INTEGER } mscAtmIfIispAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIispAddr components. These components can be added and deleted." ::= { mscAtmIfIispAddrRowStatusEntry 1 } mscAtmIfIispAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispAddrRowStatusEntry 2 } mscAtmIfIispAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIispAddr tables." ::= { mscAtmIfIispAddrRowStatusEntry 4 } mscAtmIfIispAddrAddressIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfIispAddr tables." ::= { mscAtmIfIispAddrRowStatusEntry 10 } mscAtmIfIispAddrAddressTypeIndex OBJECT-TYPE SYNTAX INTEGER { primary(0), alternate(1), default(3) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfIispAddr tables." ::= { mscAtmIfIispAddrRowStatusEntry 11 } mscAtmIfIispAddrOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the Address component." ::= { mscAtmIfIispAddr 10 } mscAtmIfIispAddrOperEntry OBJECT-TYPE SYNTAX MscAtmIfIispAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispAddrOperTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispAddrAddressIndex, mscAtmIfIispAddrAddressTypeIndex } ::= { mscAtmIfIispAddrOperTable 1 } MscAtmIfIispAddrOperEntry ::= SEQUENCE { mscAtmIfIispAddrScope INTEGER, mscAtmIfIispAddrReachability INTEGER } mscAtmIfIispAddrScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the scope of the ATM address, which is the highest level to which this address will be advertised in the PNNI hierarchy. If no PnniInfo subcomponent has been provisioned, then the scope will default to the level of this node in the PNNI hierarchy. If this node does not participate in a PNNI hierarchy, then this attribute will have the value of -1." ::= { mscAtmIfIispAddrOperEntry 1 } mscAtmIfIispAddrReachability OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether the address is internal or exterior. An internal reachable address is an address of a destination that is directly attached to the logical node advertising the address. An exterior reachable address is an address that can be reached through a PNNI routing domain, but which is not located in that PNNI routing domain." ::= { mscAtmIfIispAddrOperEntry 2 } -- AtmIf/n Iisp Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Uni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Pnni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Iisp Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Uni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Pnni Address/address,type TerminateSPvpAndSPvc -- -- The presence of this subcomponent indicates that SPvp and SPvc -- call setups terminate at this node if the destination address of the -- SPVP or SPVC matches the Address instance. mscAtmIfIispAddrTermSP OBJECT IDENTIFIER ::= { mscAtmIfIispAddr 2 } mscAtmIfIispAddrTermSPRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispAddrTermSPRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIispAddrTermSP components." ::= { mscAtmIfIispAddrTermSP 1 } mscAtmIfIispAddrTermSPRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispAddrTermSPRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIispAddrTermSP component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispAddrAddressIndex, mscAtmIfIispAddrAddressTypeIndex, mscAtmIfIispAddrTermSPIndex } ::= { mscAtmIfIispAddrTermSPRowStatusTable 1 } MscAtmIfIispAddrTermSPRowStatusEntry ::= SEQUENCE { mscAtmIfIispAddrTermSPRowStatus RowStatus, mscAtmIfIispAddrTermSPComponentName DisplayString, mscAtmIfIispAddrTermSPStorageType StorageType, mscAtmIfIispAddrTermSPIndex NonReplicated } mscAtmIfIispAddrTermSPRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIispAddrTermSP components. These components can be added and deleted." ::= { mscAtmIfIispAddrTermSPRowStatusEntry 1 } mscAtmIfIispAddrTermSPComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispAddrTermSPRowStatusEntry 2 } mscAtmIfIispAddrTermSPStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIispAddrTermSP tables." ::= { mscAtmIfIispAddrTermSPRowStatusEntry 4 } mscAtmIfIispAddrTermSPIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfIispAddrTermSP tables." ::= { mscAtmIfIispAddrTermSPRowStatusEntry 10 } -- AtmIf/n Iisp Addr/address,type PnniInfo -- AtmIf/n Uni Addr/address,type PnniInfo -- AtmIf/n Pnni Addr/address,type PnniInfo -- AtmIf/n Vpt/m Iisp Addr/address,type PnniInfo -- AtmIf/n Vpt/m Uni Addr/address,type PnniInfo -- AtmIf/n Vpt/m Pnni Addr/address,type PnniInfo -- -- This component contains provisioned information associated with -- the ATM address related to PNNI. This component appears only -- under provisioned Address components. mscAtmIfIispAddrPnniInfo OBJECT IDENTIFIER ::= { mscAtmIfIispAddr 3 } mscAtmIfIispAddrPnniInfoRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispAddrPnniInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIispAddrPnniInfo components." ::= { mscAtmIfIispAddrPnniInfo 1 } mscAtmIfIispAddrPnniInfoRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispAddrPnniInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIispAddrPnniInfo component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispAddrAddressIndex, mscAtmIfIispAddrAddressTypeIndex, mscAtmIfIispAddrPnniInfoIndex } ::= { mscAtmIfIispAddrPnniInfoRowStatusTable 1 } MscAtmIfIispAddrPnniInfoRowStatusEntry ::= SEQUENCE { mscAtmIfIispAddrPnniInfoRowStatus RowStatus, mscAtmIfIispAddrPnniInfoComponentName DisplayString, mscAtmIfIispAddrPnniInfoStorageType StorageType, mscAtmIfIispAddrPnniInfoIndex NonReplicated } mscAtmIfIispAddrPnniInfoRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIispAddrPnniInfo components. These components can be added and deleted." ::= { mscAtmIfIispAddrPnniInfoRowStatusEntry 1 } mscAtmIfIispAddrPnniInfoComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispAddrPnniInfoRowStatusEntry 2 } mscAtmIfIispAddrPnniInfoStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIispAddrPnniInfo tables." ::= { mscAtmIfIispAddrPnniInfoRowStatusEntry 4 } mscAtmIfIispAddrPnniInfoIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfIispAddrPnniInfo tables." ::= { mscAtmIfIispAddrPnniInfoRowStatusEntry 10 } mscAtmIfIispAddrPnniInfoProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispAddrPnniInfoProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisioned attributes relating to PNNI for a PnniInfo component." ::= { mscAtmIfIispAddrPnniInfo 10 } mscAtmIfIispAddrPnniInfoProvEntry OBJECT-TYPE SYNTAX MscAtmIfIispAddrPnniInfoProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispAddrPnniInfoProvTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispAddrAddressIndex, mscAtmIfIispAddrAddressTypeIndex, mscAtmIfIispAddrPnniInfoIndex } ::= { mscAtmIfIispAddrPnniInfoProvTable 1 } MscAtmIfIispAddrPnniInfoProvEntry ::= SEQUENCE { mscAtmIfIispAddrPnniInfoScope INTEGER, mscAtmIfIispAddrPnniInfoReachability INTEGER } mscAtmIfIispAddrPnniInfoScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the scope of the ATM address, which is the highest level up to which this address will be advertised in the PNNI hierarchy. The scope must be set to a value numerically less than or equal to the level of the lowest level peer group containing this node. Setting the scope to 0 will cause the address to be advertised globally within this PNNI routing domain." DEFVAL { -1 } ::= { mscAtmIfIispAddrPnniInfoProvEntry 1 } mscAtmIfIispAddrPnniInfoReachability OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates whether the address is internal or exterior. An internal reachable address is an address of a destination that is directly attached to the logical node advertising the address. An exterior reachable address is an address that can be reached through a PNNI routing domain, but which is not located in that PNNI routing domain." DEFVAL { internal } ::= { mscAtmIfIispAddrPnniInfoProvEntry 2 } -- AtmIf/n Uni CallingAddressScreening -- AtmIf/n Iisp CallingAddressScreening -- This component represents the screening of incoming ATM SVC -- call requests against provisioned ATM calling addresses (that is, -- screening SVC calls coming from specific addresses). If this -- component is not provisioned, all call requests are accepted and no -- calling address screening takes place. mscAtmIfIispCallingAScr OBJECT IDENTIFIER ::= { mscAtmIfIisp 5 } mscAtmIfIispCallingAScrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispCallingAScrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIispCallingAScr components." ::= { mscAtmIfIispCallingAScr 1 } mscAtmIfIispCallingAScrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispCallingAScrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIispCallingAScr component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispCallingAScrIndex } ::= { mscAtmIfIispCallingAScrRowStatusTable 1 } MscAtmIfIispCallingAScrRowStatusEntry ::= SEQUENCE { mscAtmIfIispCallingAScrRowStatus RowStatus, mscAtmIfIispCallingAScrComponentName DisplayString, mscAtmIfIispCallingAScrStorageType StorageType, mscAtmIfIispCallingAScrIndex NonReplicated } mscAtmIfIispCallingAScrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIispCallingAScr components. These components can be added and deleted." ::= { mscAtmIfIispCallingAScrRowStatusEntry 1 } mscAtmIfIispCallingAScrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispCallingAScrRowStatusEntry 2 } mscAtmIfIispCallingAScrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIispCallingAScr tables." ::= { mscAtmIfIispCallingAScrRowStatusEntry 4 } mscAtmIfIispCallingAScrIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfIispCallingAScr tables." ::= { mscAtmIfIispCallingAScrRowStatusEntry 10 } mscAtmIfIispCallingAScrProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispCallingAScrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes for the CallingAScr component." ::= { mscAtmIfIispCallingAScr 10 } mscAtmIfIispCallingAScrProvEntry OBJECT-TYPE SYNTAX MscAtmIfIispCallingAScrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispCallingAScrProvTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispCallingAScrIndex } ::= { mscAtmIfIispCallingAScrProvTable 1 } MscAtmIfIispCallingAScrProvEntry ::= SEQUENCE { mscAtmIfIispCallingAScrAdminStatus INTEGER, mscAtmIfIispCallingAScrDefaultInsertionAddress HexString } mscAtmIfIispCallingAScrAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(0), disabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether the calling address screening feature is enabled or disabled. If enabled, incoming SVC calls are screened against provisioned addresses. If enabled and the calling address in the ATM SVC call request is provisioned to be accepted, the call is accepted or rejected according to the action specified for that address. If the value is enabled, and the calling address in the address request is not provisioned, the call is rejected If the value is disabled, no calling address screening is performed." DEFVAL { disabled } ::= { mscAtmIfIispCallingAScrProvEntry 1 } mscAtmIfIispCallingAScrDefaultInsertionAddress OBJECT-TYPE SYNTAX HexString (SIZE (0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the address to be inserted into the SVC connection request if adminStatus is enabled and the connection request does not contain a calling address. If the adminStatus attribute is enabled and this attribute is empty, all incoming SVC calls which do not contain a calling address are rejected." DEFVAL { ''H } -- "" ::= { mscAtmIfIispCallingAScrProvEntry 2 } mscAtmIfIispCallingAScrStatTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispCallingAScrStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains statistics related to the incoming SVC call requests received while the adminStatus attribute is set to enabled." ::= { mscAtmIfIispCallingAScr 11 } mscAtmIfIispCallingAScrStatEntry OBJECT-TYPE SYNTAX MscAtmIfIispCallingAScrStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispCallingAScrStatTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispCallingAScrIndex } ::= { mscAtmIfIispCallingAScrStatTable 1 } MscAtmIfIispCallingAScrStatEntry ::= SEQUENCE { mscAtmIfIispCallingAScrAcceptedCalls Counter32, mscAtmIfIispCallingAScrRejectedCalls Counter32, mscAtmIfIispCallingAScrUnmatchedCalls Counter32 } mscAtmIfIispCallingAScrAcceptedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were accepted because the address specified in the call request matched a provisioned ATM address and the associated action was accept. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfIispCallingAScrStatEntry 1 } mscAtmIfIispCallingAScrRejectedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were rejected because the address specified in the call request matched a provisioned ATM address, but the associated action was reject. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfIispCallingAScrStatEntry 2 } mscAtmIfIispCallingAScrUnmatchedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were rejected because none of the provisioned ATM addresses matched the applicable address in the incoming SVC call request. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfIispCallingAScrStatEntry 3 } -- AtmIf/n Uni CallingAScr Address/addr,action -- AtmIf/n Iisp CallingAScr Address/addr,action -- AtmIf/n Uni CalledAScr Address/addr,action -- AtmIf/n Iisp CalledAScr Address/addr,action -- This component specifies a calling (or called) address with an -- action to accept or reject a connection request which contains a -- matching calling (or called) address. -- For the Calling Address Screening feature, if the specified action is -- accept, any call whose calling address matches that address is -- accepted. If the specified action is reject, any call whose calling -- address matches that address is rejected. -- For the Called Address Screening feature, if the specified action is -- accept, any call whose called address matches that address, is -- accepted. If the specified action is reject, any call whose called -- address matches that address is rejected. -- For both features, the incoming SVC call request is rejected if the -- address is not provisioned and the feature is enabled. mscAtmIfIispCallingAScrAddr OBJECT IDENTIFIER ::= { mscAtmIfIispCallingAScr 2 } mscAtmIfIispCallingAScrAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispCallingAScrAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIispCallingAScrAddr components." ::= { mscAtmIfIispCallingAScrAddr 1 } mscAtmIfIispCallingAScrAddrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispCallingAScrAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIispCallingAScrAddr component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispCallingAScrIndex, mscAtmIfIispCallingAScrAddrAddressIndex, mscAtmIfIispCallingAScrAddrAddressActionIndex } ::= { mscAtmIfIispCallingAScrAddrRowStatusTable 1 } MscAtmIfIispCallingAScrAddrRowStatusEntry ::= SEQUENCE { mscAtmIfIispCallingAScrAddrRowStatus RowStatus, mscAtmIfIispCallingAScrAddrComponentName DisplayString, mscAtmIfIispCallingAScrAddrStorageType StorageType, mscAtmIfIispCallingAScrAddrAddressIndex AsciiStringIndex, mscAtmIfIispCallingAScrAddrAddressActionIndex INTEGER } mscAtmIfIispCallingAScrAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIispCallingAScrAddr components. These components can be added and deleted." ::= { mscAtmIfIispCallingAScrAddrRowStatusEntry 1 } mscAtmIfIispCallingAScrAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispCallingAScrAddrRowStatusEntry 2 } mscAtmIfIispCallingAScrAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIispCallingAScrAddr tables." ::= { mscAtmIfIispCallingAScrAddrRowStatusEntry 4 } mscAtmIfIispCallingAScrAddrAddressIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfIispCallingAScrAddr tables." ::= { mscAtmIfIispCallingAScrAddrRowStatusEntry 10 } mscAtmIfIispCallingAScrAddrAddressActionIndex OBJECT-TYPE SYNTAX INTEGER { accept(0), reject(1) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfIispCallingAScrAddr tables." ::= { mscAtmIfIispCallingAScrAddrRowStatusEntry 11 } -- AtmIf/n Uni CalledAddressScreening -- AtmIf/n Iisp CalledAddressScreening -- This component represents the screening of incoming ATM SVC -- call requests against provisioned ATM called addresses (that is, -- going to specific destinations). If this component is not provisioned, -- all call requests are accepted and no called address screening takes -- place. mscAtmIfIispCalledAScr OBJECT IDENTIFIER ::= { mscAtmIfIisp 6 } mscAtmIfIispCalledAScrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispCalledAScrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIispCalledAScr components." ::= { mscAtmIfIispCalledAScr 1 } mscAtmIfIispCalledAScrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispCalledAScrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIispCalledAScr component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispCalledAScrIndex } ::= { mscAtmIfIispCalledAScrRowStatusTable 1 } MscAtmIfIispCalledAScrRowStatusEntry ::= SEQUENCE { mscAtmIfIispCalledAScrRowStatus RowStatus, mscAtmIfIispCalledAScrComponentName DisplayString, mscAtmIfIispCalledAScrStorageType StorageType, mscAtmIfIispCalledAScrIndex NonReplicated } mscAtmIfIispCalledAScrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIispCalledAScr components. These components can be added and deleted." ::= { mscAtmIfIispCalledAScrRowStatusEntry 1 } mscAtmIfIispCalledAScrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispCalledAScrRowStatusEntry 2 } mscAtmIfIispCalledAScrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIispCalledAScr tables." ::= { mscAtmIfIispCalledAScrRowStatusEntry 4 } mscAtmIfIispCalledAScrIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfIispCalledAScr tables." ::= { mscAtmIfIispCalledAScrRowStatusEntry 10 } mscAtmIfIispCalledAScrProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispCalledAScrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes for the CalledAScr component." ::= { mscAtmIfIispCalledAScr 10 } mscAtmIfIispCalledAScrProvEntry OBJECT-TYPE SYNTAX MscAtmIfIispCalledAScrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispCalledAScrProvTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispCalledAScrIndex } ::= { mscAtmIfIispCalledAScrProvTable 1 } MscAtmIfIispCalledAScrProvEntry ::= SEQUENCE { mscAtmIfIispCalledAScrAdminStatus INTEGER } mscAtmIfIispCalledAScrAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(0), disabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether the called address screening feature is enabled or disabled. If the value is enabled, incoming SVC calls will be screened against provisioned called addresses. If the value is enabled and the called address in the ATM SVC call request has been provisioned, the call is accepted or rejected according to the action specified for that address. If the value is enabled and the called address in the call request is not provisioned, the call is rejected. If the value is disabled, no called address screening is performed." DEFVAL { disabled } ::= { mscAtmIfIispCalledAScrProvEntry 1 } mscAtmIfIispCalledAScrStatTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispCalledAScrStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains statistics related to the incoming SVC call requests received while the adminStatus attribute is set to enabled." ::= { mscAtmIfIispCalledAScr 11 } mscAtmIfIispCalledAScrStatEntry OBJECT-TYPE SYNTAX MscAtmIfIispCalledAScrStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfIispCalledAScrStatTable." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispCalledAScrIndex } ::= { mscAtmIfIispCalledAScrStatTable 1 } MscAtmIfIispCalledAScrStatEntry ::= SEQUENCE { mscAtmIfIispCalledAScrAcceptedCalls Counter32, mscAtmIfIispCalledAScrRejectedCalls Counter32, mscAtmIfIispCalledAScrUnmatchedCalls Counter32 } mscAtmIfIispCalledAScrAcceptedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were accepted because the address specified in the call request matched a provisioned ATM address and the associated action was accept. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfIispCalledAScrStatEntry 1 } mscAtmIfIispCalledAScrRejectedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were rejected because the address specified in the call request matched a provisioned ATM address, but the associated action was reject. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfIispCalledAScrStatEntry 2 } mscAtmIfIispCalledAScrUnmatchedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were rejected because none of the provisioned ATM addresses matched the applicable address in the incoming SVC call request. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfIispCalledAScrStatEntry 3 } -- AtmIf/n Uni CallingAScr Address/addr,action -- AtmIf/n Iisp CallingAScr Address/addr,action -- AtmIf/n Uni CalledAScr Address/addr,action -- AtmIf/n Iisp CalledAScr Address/addr,action -- This component specifies a calling (or called) address with an -- action to accept or reject a connection request which contains a -- matching calling (or called) address. -- For the Calling Address Screening feature, if the specified action is -- accept, any call whose calling address matches that address is -- accepted. If the specified action is reject, any call whose calling -- address matches that address is rejected. -- For the Called Address Screening feature, if the specified action is -- accept, any call whose called address matches that address, is -- accepted. If the specified action is reject, any call whose called -- address matches that address is rejected. -- For both features, the incoming SVC call request is rejected if the -- address is not provisioned and the feature is enabled. mscAtmIfIispCalledAScrAddr OBJECT IDENTIFIER ::= { mscAtmIfIispCalledAScr 2 } mscAtmIfIispCalledAScrAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfIispCalledAScrAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfIispCalledAScrAddr components." ::= { mscAtmIfIispCalledAScrAddr 1 } mscAtmIfIispCalledAScrAddrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfIispCalledAScrAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfIispCalledAScrAddr component." INDEX { mscAtmIfIndex, mscAtmIfIispIndex, mscAtmIfIispCalledAScrIndex, mscAtmIfIispCalledAScrAddrAddressIndex, mscAtmIfIispCalledAScrAddrAddressActionIndex } ::= { mscAtmIfIispCalledAScrAddrRowStatusTable 1 } MscAtmIfIispCalledAScrAddrRowStatusEntry ::= SEQUENCE { mscAtmIfIispCalledAScrAddrRowStatus RowStatus, mscAtmIfIispCalledAScrAddrComponentName DisplayString, mscAtmIfIispCalledAScrAddrStorageType StorageType, mscAtmIfIispCalledAScrAddrAddressIndex AsciiStringIndex, mscAtmIfIispCalledAScrAddrAddressActionIndex INTEGER } mscAtmIfIispCalledAScrAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfIispCalledAScrAddr components. These components can be added and deleted." ::= { mscAtmIfIispCalledAScrAddrRowStatusEntry 1 } mscAtmIfIispCalledAScrAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfIispCalledAScrAddrRowStatusEntry 2 } mscAtmIfIispCalledAScrAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfIispCalledAScrAddr tables." ::= { mscAtmIfIispCalledAScrAddrRowStatusEntry 4 } mscAtmIfIispCalledAScrAddrAddressIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfIispCalledAScrAddr tables." ::= { mscAtmIfIispCalledAScrAddrRowStatusEntry 10 } mscAtmIfIispCalledAScrAddrAddressActionIndex OBJECT-TYPE SYNTAX INTEGER { accept(0), reject(1) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfIispCalledAScrAddr tables." ::= { mscAtmIfIispCalledAScrAddrRowStatusEntry 11 } -- AtmIf/n VirtualPathTerminator/m Iisp -- This component represents a virtual ATM Interim Inter-switch -- Signaling Protocol (IISP) interface. If this component is -- provisioned, neither a Uni component nor a Pnni component can be -- provisioned under the same Vpt component. If this component is -- deleted, then all associated Vcc components are deleted. mscAtmIfVptIisp OBJECT IDENTIFIER ::= { mscAtmIfVpt 6 } mscAtmIfVptIispRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIisp components." ::= { mscAtmIfVptIisp 1 } mscAtmIfVptIispRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIisp component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex } ::= { mscAtmIfVptIispRowStatusTable 1 } MscAtmIfVptIispRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispRowStatus RowStatus, mscAtmIfVptIispComponentName DisplayString, mscAtmIfVptIispStorageType StorageType, mscAtmIfVptIispIndex NonReplicated } mscAtmIfVptIispRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIisp components. These components can be added and deleted." ::= { mscAtmIfVptIispRowStatusEntry 1 } mscAtmIfVptIispComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispRowStatusEntry 2 } mscAtmIfVptIispStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIisp tables." ::= { mscAtmIfVptIispRowStatusEntry 4 } mscAtmIfVptIispIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptIisp tables." ::= { mscAtmIfVptIispRowStatusEntry 10 } mscAtmIfVptIispProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for the Iisp component." ::= { mscAtmIfVptIisp 10 } mscAtmIfVptIispProvEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispProvTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex } ::= { mscAtmIfVptIispProvTable 1 } MscAtmIfVptIispProvEntry ::= SEQUENCE { mscAtmIfVptIispVersion INTEGER, mscAtmIfVptIispSide INTEGER, mscAtmIfVptIispSoftPvcRetryPeriod Unsigned32, mscAtmIfVptIispSoftPvpAndPvcRetryPeriod Unsigned32, mscAtmIfVptIispSoftPvpAndPvcHoldOffTime Unsigned32 } mscAtmIfVptIispVersion OBJECT-TYPE SYNTAX INTEGER { iisp10Sig30(2), iisp10Sig31(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates which specification the IISP interface complies with. The options are iisp10Sig30 which refers to IISP version 1.0 with 3.0 signalling and iisp10Sig31 which refers to IISP version 1.0 with 3.1 signalling. If this attribute is changed, all switched Vcc components in this interface are cleared due to the fact that the two versions are incompatible." DEFVAL { iisp10Sig31 } ::= { mscAtmIfVptIispProvEntry 1 } mscAtmIfVptIispSide OBJECT-TYPE SYNTAX INTEGER { networkSide(0), userSide(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates which side the interface is, user or network." DEFVAL { networkSide } ::= { mscAtmIfVptIispProvEntry 2 } mscAtmIfVptIispSoftPvcRetryPeriod OBJECT-TYPE SYNTAX Unsigned32 (20..999999) ACCESS read-write STATUS obsolete DESCRIPTION "This attribute specifies the time to wait between call set up retries. The resolution is to the nearest 10 seconds. This attribute has been obsoleted and is replaced by the softPvpAndPvcRetryPeriod attribute." DEFVAL { 60 } ::= { mscAtmIfVptIispProvEntry 3 } mscAtmIfVptIispSoftPvpAndPvcRetryPeriod OBJECT-TYPE SYNTAX Unsigned32 (20..999999) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the time to wait between soft PVP or soft PVC call setup retries. The resolution is to the nearest 10 seconds." DEFVAL { 60 } ::= { mscAtmIfVptIispProvEntry 4 } mscAtmIfVptIispSoftPvpAndPvcHoldOffTime OBJECT-TYPE SYNTAX Unsigned32 (0 | 50..20000) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies how long to hold off retries following a release or the connection. The resolution is to the nearest 50 ms." DEFVAL { 0 } ::= { mscAtmIfVptIispProvEntry 5 } mscAtmIfVptIispAcctOptTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispAcctOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for accounting." ::= { mscAtmIfVptIisp 11 } mscAtmIfVptIispAcctOptEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispAcctOptEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispAcctOptTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex } ::= { mscAtmIfVptIispAcctOptTable 1 } MscAtmIfVptIispAcctOptEntry ::= SEQUENCE { mscAtmIfVptIispAccountCollection OCTET STRING, mscAtmIfVptIispAccountConnectionType INTEGER, mscAtmIfVptIispAccountClass Unsigned32, mscAtmIfVptIispServiceExchange Unsigned32 } mscAtmIfVptIispAccountCollection OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is used to turn accounting on or off for SVC and SPVC connections. It also specifies the reason(s) for which accounting data is collected: billing, test, study, audit, or force. If the set of reasons is not empty then accounting records will be generated by this interface in the following situations: - on a TODA changeover if TODA is enabled; - every 12 hours (per connection) if TODA is disabled; - on every call clear (a call record with final cell counts). If none of the reasons is present, then accounting will be suppressed. The reason for collection is recorded in the accounting record, in the attribute callingCollectReason or calledCollectReason as appropriate. Description of bits: bill(0) test(1) study(2) audit(3) force(4)" ::= { mscAtmIfVptIispAcctOptEntry 1 } mscAtmIfVptIispAccountConnectionType OBJECT-TYPE SYNTAX INTEGER { origTerm(0), intermediate(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether accounting records generated by this interface should be marked as originating, terminating or intermediate. This attribute, in combination with the direction of the call, determines the value of attribute connPointType of the accounting record and may be used by downstream accounting processes to correlate the records. If the value is origTerm then records generated for incoming calls will be marked as originating and records generated for outgoing calls will be marked as terminating. If the value is intermediate then records generated for all calls will be marked as intermediate." DEFVAL { intermediate } ::= { mscAtmIfVptIispAcctOptEntry 2 } mscAtmIfVptIispAccountClass OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the accounting class associated with the interface. Its meaning is determined by the network operator. Its value is simply recorded in the accounting records generated by this interface, in the attribute callingServiceType or calledServiceType as appropriate." DEFVAL { 0 } ::= { mscAtmIfVptIispAcctOptEntry 3 } mscAtmIfVptIispServiceExchange OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the data service exchange associated with this interface. Its meaning is determined by the network operator. Its value is simply recorded in the accounting records generated by this interface, in the attribute callingDse or calledDse as appropriate." DEFVAL { 0 } ::= { mscAtmIfVptIispAcctOptEntry 4 } mscAtmIfVptIispVProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispVProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable attributes for the Iisp component which are specific to virtual IISP interfaces." ::= { mscAtmIfVptIisp 12 } mscAtmIfVptIispVProvEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispVProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispVProvTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex } ::= { mscAtmIfVptIispVProvTable 1 } MscAtmIfVptIispVProvEntry ::= SEQUENCE { mscAtmIfVptIispVpci Unsigned32 } mscAtmIfVptIispVpci OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the Virtual Path Connection Identifier (VPCI) to be used between this signalling entity and its peer. The VPCI of the peer virtual IISP must have the same value for switched connections to be set up across the interface." DEFVAL { 0 } ::= { mscAtmIfVptIispVProvEntry 1 } -- AtmIf/n Iisp Signalling -- AtmIf/n Uni Signalling -- AtmIf/n Pnni Signalling -- AtmIf/n Vpt/m Iisp Signalling -- AtmIf/n Vpt/m Uni Signalling -- AtmIf/n Vpt/m Pnni Signalling -- -- This component represents the signalling entities for the interface. mscAtmIfVptIispSig OBJECT IDENTIFIER ::= { mscAtmIfVptIisp 3 } mscAtmIfVptIispSigRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispSigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIispSig components." ::= { mscAtmIfVptIispSig 1 } mscAtmIfVptIispSigRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispSigRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIispSig component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispSigIndex } ::= { mscAtmIfVptIispSigRowStatusTable 1 } MscAtmIfVptIispSigRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispSigRowStatus RowStatus, mscAtmIfVptIispSigComponentName DisplayString, mscAtmIfVptIispSigStorageType StorageType, mscAtmIfVptIispSigIndex NonReplicated } mscAtmIfVptIispSigRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIispSig components. These components cannot be added nor deleted." ::= { mscAtmIfVptIispSigRowStatusEntry 1 } mscAtmIfVptIispSigComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispSigRowStatusEntry 2 } mscAtmIfVptIispSigStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIispSig tables." ::= { mscAtmIfVptIispSigRowStatusEntry 4 } mscAtmIfVptIispSigIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptIispSig tables." ::= { mscAtmIfVptIispSigRowStatusEntry 10 } mscAtmIfVptIispSigProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispSigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes for the Signalling component." ::= { mscAtmIfVptIispSig 10 } mscAtmIfVptIispSigProvEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispSigProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispSigProvTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispSigIndex } ::= { mscAtmIfVptIispSigProvTable 1 } MscAtmIfVptIispSigProvEntry ::= SEQUENCE { mscAtmIfVptIispSigVci Unsigned32, mscAtmIfVptIispSigAddressConversion INTEGER, mscAtmIfVptIispSigOperatingMode INTEGER } mscAtmIfVptIispSigVci OBJECT-TYPE SYNTAX Unsigned32 (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the signalling channel number." DEFVAL { 5 } ::= { mscAtmIfVptIispSigProvEntry 1 } mscAtmIfVptIispSigAddressConversion OBJECT-TYPE SYNTAX INTEGER { none(0), nativeE164(1), nsap(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the address conversion on the outgoing signalling PDUs. The options are none, nativeE164, or nsap. The none option is the default and if this option is chosen then nothing is done to the address information element (IE) in the outgoing signalling message. If nativeE164 option is chosen, then only NSAP encapsulated E.164 addresses with zeros in the ESI are converted to native E.164 format in the outgoing signalling message. If the NSAP address is not encapsulated E.164 or the ESI field is not zeros and the nativeE164 option is chosen, then the call is cleared. If the nsap option is chosen, then native E.164 addresses are converted to NSAP E.164 with zeros in the ESI field; otherwise the address is in NSAP format and is not changed." DEFVAL { none } ::= { mscAtmIfVptIispSigProvEntry 2 } mscAtmIfVptIispSigOperatingMode OBJECT-TYPE SYNTAX INTEGER { normal(0), provisionedOnly(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the operating mode of the signaling channel. provisionedOnly indicates that only SPVCs and SPVPs are supported on the interface and SVCs are not supported. This value is permitted only on UNI interfaces. normal indicates that SVCs, SPVCs, and SPVPs are supported on the interface." DEFVAL { normal } ::= { mscAtmIfVptIispSigProvEntry 3 } mscAtmIfVptIispSigStateTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispSigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide." ::= { mscAtmIfVptIispSig 11 } mscAtmIfVptIispSigStateEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispSigStateEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispSigStateTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispSigIndex } ::= { mscAtmIfVptIispSigStateTable 1 } MscAtmIfVptIispSigStateEntry ::= SEQUENCE { mscAtmIfVptIispSigAdminState INTEGER, mscAtmIfVptIispSigOperationalState INTEGER, mscAtmIfVptIispSigUsageState INTEGER } mscAtmIfVptIispSigAdminState OBJECT-TYPE SYNTAX INTEGER { locked(0), unlocked(1), shuttingDown(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component." DEFVAL { unlocked } ::= { mscAtmIfVptIispSigStateEntry 1 } mscAtmIfVptIispSigOperationalState OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle." DEFVAL { disabled } ::= { mscAtmIfVptIispSigStateEntry 2 } mscAtmIfVptIispSigUsageState OBJECT-TYPE SYNTAX INTEGER { idle(0), active(1), busy(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time." DEFVAL { idle } ::= { mscAtmIfVptIispSigStateEntry 3 } mscAtmIfVptIispSigOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispSigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute contains the operational attributes for the AtmSignalling component." ::= { mscAtmIfVptIispSig 12 } mscAtmIfVptIispSigOperEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispSigOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispSigOperTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispSigIndex } ::= { mscAtmIfVptIispSigOperTable 1 } MscAtmIfVptIispSigOperEntry ::= SEQUENCE { mscAtmIfVptIispSigLastTxCauseCode Unsigned32, mscAtmIfVptIispSigLastTxDiagCode Hex, mscAtmIfVptIispSigLastRxCauseCode Unsigned32, mscAtmIfVptIispSigLastRxDiagCode Hex } mscAtmIfVptIispSigLastTxCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the cause code in the last transmitted signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages." ::= { mscAtmIfVptIispSigOperEntry 1 } mscAtmIfVptIispSigLastTxDiagCode OBJECT-TYPE SYNTAX Hex (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last transmitted signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to 0." ::= { mscAtmIfVptIispSigOperEntry 2 } mscAtmIfVptIispSigLastRxCauseCode OBJECT-TYPE SYNTAX Unsigned32 (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the cause code in the last received signalling message that contains the CAUSE information element. The cause code is used to describe the reason for generating certain signalling messages." ::= { mscAtmIfVptIispSigOperEntry 3 } mscAtmIfVptIispSigLastRxDiagCode OBJECT-TYPE SYNTAX Hex (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the diagnostic code in the last received signalling message. The diagnostic code is contained in the CAUSE information element and identifies an information element type or timer type. The diagnostic code is present only if a procedural error is detected by the signalling protocol. A diagnostic code is always accompanied by the cause code. If there is no failure, this attribute is set to 0." ::= { mscAtmIfVptIispSigOperEntry 4 } mscAtmIfVptIispSigStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispSigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the statistics associated with the AtmSignalling component." ::= { mscAtmIfVptIispSig 13 } mscAtmIfVptIispSigStatsEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispSigStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispSigStatsTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispSigIndex } ::= { mscAtmIfVptIispSigStatsTable 1 } MscAtmIfVptIispSigStatsEntry ::= SEQUENCE { mscAtmIfVptIispSigCurrentConnections Counter32, mscAtmIfVptIispSigPeakConnections Gauge32, mscAtmIfVptIispSigSuccessfulConnections Counter32, mscAtmIfVptIispSigFailedConnections Counter32, mscAtmIfVptIispSigTxPdus Counter32, mscAtmIfVptIispSigRxPdus Counter32, mscAtmIfVptIispSigCurrentPmpConnections Gauge32, mscAtmIfVptIispSigPeakPmpConnections Gauge32, mscAtmIfVptIispSigSuccessfulPmpConnections Counter32, mscAtmIfVptIispSigFailedPmpConnections Counter32, mscAtmIfVptIispSigNewCurrentConnections Gauge32 } mscAtmIfVptIispSigCurrentConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS obsolete DESCRIPTION "This attribute indicates the total number of currently active connections." ::= { mscAtmIfVptIispSigStatsEntry 1 } mscAtmIfVptIispSigPeakConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the high water mark of active point-to- point and point-to-multipoint connections." ::= { mscAtmIfVptIispSigStatsEntry 2 } mscAtmIfVptIispSigSuccessfulConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched point-to- point and point-to-multipoint connections that were successfully established. The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfVptIispSigStatsEntry 3 } mscAtmIfVptIispSigFailedConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched connections that were not successfully established.The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfVptIispSigStatsEntry 4 } mscAtmIfVptIispSigTxPdus OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of transmitted signalling PDUs.The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfVptIispSigStatsEntry 5 } mscAtmIfVptIispSigRxPdus OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of received signalling PDUs.The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfVptIispSigStatsEntry 6 } mscAtmIfVptIispSigCurrentPmpConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the number of currently active point-to- multipoint connections." ::= { mscAtmIfVptIispSigStatsEntry 7 } mscAtmIfVptIispSigPeakPmpConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the high water mark of active point-to- multipoint connections." ::= { mscAtmIfVptIispSigStatsEntry 8 } mscAtmIfVptIispSigSuccessfulPmpConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the total number of switched point-to- multipoint connections that were successfully established. The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfVptIispSigStatsEntry 9 } mscAtmIfVptIispSigFailedPmpConnections OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the number of switched point-to- multipoint connections that were not successfully established.The counter wraps to 0 when the maximum value is exceeded." ::= { mscAtmIfVptIispSigStatsEntry 10 } mscAtmIfVptIispSigNewCurrentConnections OBJECT-TYPE SYNTAX Gauge32 (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the total number of currently active point-to- point and point-to-multipoint connections." ::= { mscAtmIfVptIispSigStatsEntry 11 } -- AtmIf/n Uni Sig VirtualChannelDescriptor -- AtmIf/n Uni Ilmi VirtualChannelDescriptor -- AtmIf/n Iisp Sig VirtualChannelDescriptor -- AtmIf/n Pnni Sig VirtualChannelDescriptor -- AtmIf/n Pnni Rcc VirtualChannelDescriptor -- AtmIf/n Vpt/m Uni Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Iisp Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Pnni Sig VirtualChannelDescriptor -- AtmIf/n Vpt/m Pnni Rcc VirtualChannelDescriptor -- -- This component contains the provisionable traffic parameters for a -- control channel (Sig, Ilmi or Rcc component). mscAtmIfVptIispSigVcd OBJECT IDENTIFIER ::= { mscAtmIfVptIispSig 2 } mscAtmIfVptIispSigVcdRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispSigVcdRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIispSigVcd components." ::= { mscAtmIfVptIispSigVcd 1 } mscAtmIfVptIispSigVcdRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispSigVcdRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIispSigVcd component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispSigIndex, mscAtmIfVptIispSigVcdIndex } ::= { mscAtmIfVptIispSigVcdRowStatusTable 1 } MscAtmIfVptIispSigVcdRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispSigVcdRowStatus RowStatus, mscAtmIfVptIispSigVcdComponentName DisplayString, mscAtmIfVptIispSigVcdStorageType StorageType, mscAtmIfVptIispSigVcdIndex NonReplicated } mscAtmIfVptIispSigVcdRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIispSigVcd components. These components can be added and deleted." ::= { mscAtmIfVptIispSigVcdRowStatusEntry 1 } mscAtmIfVptIispSigVcdComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispSigVcdRowStatusEntry 2 } mscAtmIfVptIispSigVcdStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIispSigVcd tables." ::= { mscAtmIfVptIispSigVcdRowStatusEntry 4 } mscAtmIfVptIispSigVcdIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptIispSigVcd tables." ::= { mscAtmIfVptIispSigVcdRowStatusEntry 10 } mscAtmIfVptIispSigVcdProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispSigVcdProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This group contains the provisionable traffic attributes for a control channel." ::= { mscAtmIfVptIispSigVcd 10 } mscAtmIfVptIispSigVcdProvEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispSigVcdProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispSigVcdProvTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispSigIndex, mscAtmIfVptIispSigVcdIndex } ::= { mscAtmIfVptIispSigVcdProvTable 1 } MscAtmIfVptIispSigVcdProvEntry ::= SEQUENCE { mscAtmIfVptIispSigVcdTrafficDescType INTEGER, mscAtmIfVptIispSigVcdAtmServiceCategory INTEGER, mscAtmIfVptIispSigVcdWeight Unsigned32, mscAtmIfVptIispSigVcdQosClass INTEGER, mscAtmIfVptIispSigVcdTrafficShaping INTEGER, mscAtmIfVptIispSigVcdUnshapedTransmitQueueing INTEGER, mscAtmIfVptIispSigVcdUsageParameterControl INTEGER } mscAtmIfVptIispSigVcdTrafficDescType OBJECT-TYPE SYNTAX INTEGER { n3(3), n6(6), n7(7), n8(8) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the type of traffic management which is applied to both the transmit and receive direction of this connection as defined in the ATM Forum. The trafficDescType determines the number and meaning of the parameters in the trafficDescParm attribute." DEFVAL { n6 } ::= { mscAtmIfVptIispSigVcdProvEntry 1 } mscAtmIfVptIispSigVcdAtmServiceCategory OBJECT-TYPE SYNTAX INTEGER { unspecifiedBitRate(0), constantBitRate(1), rtVariableBitRate(2), nrtVariableBitRate(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the ATM service category for both directions of the connection. The constantBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. The consistent availability of a fixed quantity of bandwidth is considered appropriate for CBR service. Cells which are delayed beyond the value specified by CellTransfer Delay are assumed to be of significantly reduce value to the application. The rtVariableBitRate service category is intended for real time applications, that is those requiring tightly constrained delay and delay variation, as would be appropriate for voice and video applications. Sources are expected to transmit at a rate which varies with time. Equivalently, the source can be described as 'bursty'. Cells which are delayed beyond the value specified by CTD are assumed to be of significantly reduced value to the application. Real time VBR service may support statistical multiplexing of real time sources. The nrtVariableBitRate service category is intended for non-real time applications which have bursty traffic characteristics and which can be characterized in terms of a PCR, SCR, and MBS. For those cells which are transferred within the traffic contract, the application expects a low cell loss ratio. For all connections, it expects a bound on the mean cell transfer delay. Non-real time VBR service may support statistical multiplexing of connections. The unspecifiedBitRate service is intended for non-real time applications; that is, those not requiring tightly constrained delay and delay variation. UBR sources are expected to be bursty. UBR service supports a high degree of statistical multiplexing among sources. UBR service does not specify traffic related service guarantees. No numerical commitments are made with respect to the cell loss ratio experienced by a UBR connection, or as to the cell transfer delay experienced by cells on the connection." DEFVAL { rtVariableBitRate } ::= { mscAtmIfVptIispSigVcdProvEntry 3 } mscAtmIfVptIispSigVcdWeight OBJECT-TYPE SYNTAX Unsigned32 (0 | 1..4095 | 65535) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies an override for the weight of this unshaped connection. This attribute is ignored for shaped connections, for ABR connections, for connections on a CQC-based ATM FP and basic VPTs. When the value is set to sameAsCa, the weight is determined by the weight policy attribute under the CA service category component for all but standard VPT VCCs. For standard VPT VCCs, the weight is determined by the VCC's service category, when the value is set to sameAsCa. When this attribute is set to a value from 1 to 4095, that value is used for the weight policy of this connection relative to other connections. For all but standard VPT VCCs, weight policy determines the proportion of transit cell opportunities which are allocated to this connection, compared to other connections in the same service category. For standard VPT VCCs, weight policy determines the proportion of transmit cell opportunities which are allocated to this connection, compared to other connections associated with the VPT. When the value is set to upToQueueLimit, the weight policy is limited only by the txQueueLimit. VALUES ( 0 = upToQueueLimit 65535 = sameAsCa )" DEFVAL { 65535 } ::= { mscAtmIfVptIispSigVcdProvEntry 4 } mscAtmIfVptIispSigVcdQosClass OBJECT-TYPE SYNTAX INTEGER { n0(0), n1(1), n2(2), n3(3), n4(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the quality of service for both the forward and backward direction for this connection. Class 1 supports a QOS that meets Service Class A performance requirements (Circuit emulation, constant bit rate video). Class 2 supports a QOS that meets Service Class B performance requirements (Variable bit rate audio and video). Class 3 supports a QOS that meets Service Class C performance requirements (Connection-Oriented Data Transfer). Class 4 supports a QOS that meets Service Class D performance requirements (Connectionless Data Transfer). Class 0 is the unspecified bit rate QOS class; no objective is specified for the performance parameters." DEFVAL { n2 } ::= { mscAtmIfVptIispSigVcdProvEntry 21 } mscAtmIfVptIispSigVcdTrafficShaping OBJECT-TYPE SYNTAX INTEGER { disabled(1), sameAsCa(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether this connection uses traffic shaping when transmitting traffic to the ATM interface. When sameAsCa is selected, traffic shaping for this connection is based on the trafficShaping attribute of the connection's service category component under the AtmIf CA. If the service category has traffic shaping enabled, then traffic shaping is enabled for the connection. Note that enabling traffic shaping may have no effect under certain cases. These cases are listed in the description of the trafficShaping operational attribute, which is under the Vcc Tm and Vpc Tm components. When disabled is selected, traffic shaping for this connection is disabled." DEFVAL { disabled } ::= { mscAtmIfVptIispSigVcdProvEntry 50 } mscAtmIfVptIispSigVcdUnshapedTransmitQueueing OBJECT-TYPE SYNTAX INTEGER { common(1), sameAsCa(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute only applies when this connection is unshaped. This attribute specifies the transmit queueing method for this connection if it is unshaped. Refer to the unshapedTransmitQueueing attribute under the AtmIf CA service category subcomponent for more details on the meaning of this attribute. When this attribute is set to sameAsCa, the transmit queueing method for the connection is based on the unshapedTransmitQueueing attribute of the connection's service category component under the ConnectionAdministrator. When this attribute is set to common, transmit traffic on this unshaped connection is destined for the common queue. The value sameAsInterface is for migration from previous software releases, but should no longer be used" DEFVAL { sameAsCa } ::= { mscAtmIfVptIispSigVcdProvEntry 60 } mscAtmIfVptIispSigVcdUsageParameterControl OBJECT-TYPE SYNTAX INTEGER { disabled(1), sameAsCa(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether this connection enforces usage parameter control when receiving traffic from the ATM interface. When sameAsCa is selected, UPC for the connection is based on the usageParameterControl attribute of the connection's service category component under the ConnectionAdministrator. If the service category has UPC enabled, then UPC is enabled for the connection. Note that enabling UPC may have no effect under certain cases. These cases are listed in the description of the usageParameterControl operational attribute, which is under the Vcc Tm or Vpc Tm component. When disabled is selected, UPC for this connection is disabled. The value sameAsInterface is for migration from previous software releases, but should no longer be used" DEFVAL { disabled } ::= { mscAtmIfVptIispSigVcdProvEntry 70 } mscAtmIfVptIispSigVcdTdpTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispSigVcdTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute is a vector of five traffic parameters whose meanings are defined by the trafficDescType attribute. The values of peak cell rate (PCR), sustained cell rate (SCR) and requested shaping rate are expressed in cell/s. Maximum burst size (MBS) is expressed in cells. CDVT is expressed in microseconds. The values of PCR, SCR, MBS and CDVT are used for connection admission control (CAC). The value of CDVT is only used for connections where the atmServiceCategory is constantBitRate. For all other values of atmServiceCategory, CDVT is ignored. The values of PCR, SCR and requested shaping rate are used to determine the actual shaping rate where traffic shaping is enabled. When trafficDescType is 3, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameter 1 must be non-zero. Parameters 2 and 3 must be zero. When trafficDescType is 6, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 and 1 traffic; parameter 3 represents the MBS for CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. When trafficDescType is 7, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 with cell discard; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. When trafficDescType is 8, parameter 1 represents the PCR for CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP equal to 0 traffic with cell tagging; parameter 3 represents the MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT; and parameter 5 represents the requested shaping rate. A non-zero value in parameter 5 overrides any value in parameter 1. This result is used as the PCR. Parameters 1, 2, and 3 must be non-zero. Parameter 1 must be greater than or equal to parameter 2. Parameter 5 must either be zero (unused) or greater than or equal to parameter 2. Whenever it is valid for PCR to be specified, parameter 5 may also be used to specify a requested shaping rate. A non-zero value in parameter 5 overrides the value in parameter 1 and is used as the peak cell rate in calculations of CAC and shaping rate. For trafficDescType 3 the traffic is shaped at the next rate less than the PCR. For trafficDescType 6, 7, and 8, the traffic is shaped at the highest available rate which is between PCR and SCR. However, if there is no available shaping rate between PCR and SCR, traffic is shaped at the next rate above the PCR." ::= { mscAtmIfVptIispSigVcd 387 } mscAtmIfVptIispSigVcdTdpEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispSigVcdTdpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispSigVcdTdpTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispSigIndex, mscAtmIfVptIispSigVcdIndex, mscAtmIfVptIispSigVcdTdpIndex } ::= { mscAtmIfVptIispSigVcdTdpTable 1 } MscAtmIfVptIispSigVcdTdpEntry ::= SEQUENCE { mscAtmIfVptIispSigVcdTdpIndex Integer32, mscAtmIfVptIispSigVcdTdpValue Unsigned32 } mscAtmIfVptIispSigVcdTdpIndex OBJECT-TYPE SYNTAX Integer32 (1..5) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the mscAtmIfVptIispSigVcdTdpTable specific index for the mscAtmIfVptIispSigVcdTdpTable." ::= { mscAtmIfVptIispSigVcdTdpEntry 1 } mscAtmIfVptIispSigVcdTdpValue OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This variable represents an individual value for the mscAtmIfVptIispSigVcdTdpTable." ::= { mscAtmIfVptIispSigVcdTdpEntry 2 } -- AtmIf/n Iisp Address/address,type -- AtmIf/n Uni Address/address,type -- AtmIf/n Pnni Address/address,type -- AtmIf/n Vpt/m Iisp Address/address,type -- AtmIf/n Vpt/m Uni Address/address,type -- AtmIf/n Vpt/m Pnni Address/address,type -- -- This component represents an address (dynamic or static) -- associated with the interface. The index is a string of 1 to 40 hex -- digits or a single wildcard ('?'), and a type. The type identifies -- whether the Address component is for a primary, alternate, -- registered, or default address. -- -- The types primary and alternate are used for provisioned addresses. -- The type registered is used for dynamic addresses registered -- through ILMI. The type default is used for Soft PVP and Soft PVC -- addresses.Virtual interfaces do not have addresses of -- type default. -- -- The wildcard is only valid for provisioned addresses. If the address -- is a single wildcard, then that indicates that the interface supports -- all addresses. If there is no better match, then this interface may be -- chosen in the routing. If there is more than one interface with a -- single wildcard static address, then the choice is driven through a -- round robin algorithm. -- -- The round robin algorithm tries the primary routes and then the -- alternate routes if none of the primary routes succeed. -- If this node participates in a PNNI hierarchy, then a PnniInfo -- subcomponent can be provisioned under the AtmAddress -- component to specify the level to which this address will be -- advertised. mscAtmIfVptIispAddr OBJECT IDENTIFIER ::= { mscAtmIfVptIisp 4 } mscAtmIfVptIispAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIispAddr components." ::= { mscAtmIfVptIispAddr 1 } mscAtmIfVptIispAddrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIispAddr component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispAddrAddressIndex, mscAtmIfVptIispAddrAddressTypeIndex } ::= { mscAtmIfVptIispAddrRowStatusTable 1 } MscAtmIfVptIispAddrRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispAddrRowStatus RowStatus, mscAtmIfVptIispAddrComponentName DisplayString, mscAtmIfVptIispAddrStorageType StorageType, mscAtmIfVptIispAddrAddressIndex AsciiStringIndex, mscAtmIfVptIispAddrAddressTypeIndex INTEGER } mscAtmIfVptIispAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIispAddr components. These components can be added and deleted." ::= { mscAtmIfVptIispAddrRowStatusEntry 1 } mscAtmIfVptIispAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispAddrRowStatusEntry 2 } mscAtmIfVptIispAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIispAddr tables." ::= { mscAtmIfVptIispAddrRowStatusEntry 4 } mscAtmIfVptIispAddrAddressIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfVptIispAddr tables." ::= { mscAtmIfVptIispAddrRowStatusEntry 10 } mscAtmIfVptIispAddrAddressTypeIndex OBJECT-TYPE SYNTAX INTEGER { primary(0), alternate(1), default(3) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfVptIispAddr tables." ::= { mscAtmIfVptIispAddrRowStatusEntry 11 } mscAtmIfVptIispAddrOperTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the operational attributes for the Address component." ::= { mscAtmIfVptIispAddr 10 } mscAtmIfVptIispAddrOperEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispAddrOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispAddrOperTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispAddrAddressIndex, mscAtmIfVptIispAddrAddressTypeIndex } ::= { mscAtmIfVptIispAddrOperTable 1 } MscAtmIfVptIispAddrOperEntry ::= SEQUENCE { mscAtmIfVptIispAddrScope INTEGER, mscAtmIfVptIispAddrReachability INTEGER } mscAtmIfVptIispAddrScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the scope of the ATM address, which is the highest level to which this address will be advertised in the PNNI hierarchy. If no PnniInfo subcomponent has been provisioned, then the scope will default to the level of this node in the PNNI hierarchy. If this node does not participate in a PNNI hierarchy, then this attribute will have the value of -1." ::= { mscAtmIfVptIispAddrOperEntry 1 } mscAtmIfVptIispAddrReachability OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether the address is internal or exterior. An internal reachable address is an address of a destination that is directly attached to the logical node advertising the address. An exterior reachable address is an address that can be reached through a PNNI routing domain, but which is not located in that PNNI routing domain." ::= { mscAtmIfVptIispAddrOperEntry 2 } -- AtmIf/n Iisp Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Uni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Pnni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Iisp Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Uni Address/address,type TerminateSPvpAndSPvc -- AtmIf/n Vpt/m Pnni Address/address,type TerminateSPvpAndSPvc -- -- The presence of this subcomponent indicates that SPvp and SPvc -- call setups terminate at this node if the destination address of the -- SPVP or SPVC matches the Address instance. mscAtmIfVptIispAddrTermSP OBJECT IDENTIFIER ::= { mscAtmIfVptIispAddr 2 } mscAtmIfVptIispAddrTermSPRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispAddrTermSPRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIispAddrTermSP components." ::= { mscAtmIfVptIispAddrTermSP 1 } mscAtmIfVptIispAddrTermSPRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispAddrTermSPRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIispAddrTermSP component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispAddrAddressIndex, mscAtmIfVptIispAddrAddressTypeIndex, mscAtmIfVptIispAddrTermSPIndex } ::= { mscAtmIfVptIispAddrTermSPRowStatusTable 1 } MscAtmIfVptIispAddrTermSPRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispAddrTermSPRowStatus RowStatus, mscAtmIfVptIispAddrTermSPComponentName DisplayString, mscAtmIfVptIispAddrTermSPStorageType StorageType, mscAtmIfVptIispAddrTermSPIndex NonReplicated } mscAtmIfVptIispAddrTermSPRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIispAddrTermSP components. These components can be added and deleted." ::= { mscAtmIfVptIispAddrTermSPRowStatusEntry 1 } mscAtmIfVptIispAddrTermSPComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispAddrTermSPRowStatusEntry 2 } mscAtmIfVptIispAddrTermSPStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIispAddrTermSP tables." ::= { mscAtmIfVptIispAddrTermSPRowStatusEntry 4 } mscAtmIfVptIispAddrTermSPIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptIispAddrTermSP tables." ::= { mscAtmIfVptIispAddrTermSPRowStatusEntry 10 } -- AtmIf/n Iisp Addr/address,type PnniInfo -- AtmIf/n Uni Addr/address,type PnniInfo -- AtmIf/n Pnni Addr/address,type PnniInfo -- AtmIf/n Vpt/m Iisp Addr/address,type PnniInfo -- AtmIf/n Vpt/m Uni Addr/address,type PnniInfo -- AtmIf/n Vpt/m Pnni Addr/address,type PnniInfo -- -- This component contains provisioned information associated with -- the ATM address related to PNNI. This component appears only -- under provisioned Address components. mscAtmIfVptIispAddrPnniInfo OBJECT IDENTIFIER ::= { mscAtmIfVptIispAddr 3 } mscAtmIfVptIispAddrPnniInfoRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispAddrPnniInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIispAddrPnniInfo components." ::= { mscAtmIfVptIispAddrPnniInfo 1 } mscAtmIfVptIispAddrPnniInfoRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispAddrPnniInfoRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIispAddrPnniInfo component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispAddrAddressIndex, mscAtmIfVptIispAddrAddressTypeIndex, mscAtmIfVptIispAddrPnniInfoIndex } ::= { mscAtmIfVptIispAddrPnniInfoRowStatusTable 1 } MscAtmIfVptIispAddrPnniInfoRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispAddrPnniInfoRowStatus RowStatus, mscAtmIfVptIispAddrPnniInfoComponentName DisplayString, mscAtmIfVptIispAddrPnniInfoStorageType StorageType, mscAtmIfVptIispAddrPnniInfoIndex NonReplicated } mscAtmIfVptIispAddrPnniInfoRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIispAddrPnniInfo components. These components can be added and deleted." ::= { mscAtmIfVptIispAddrPnniInfoRowStatusEntry 1 } mscAtmIfVptIispAddrPnniInfoComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispAddrPnniInfoRowStatusEntry 2 } mscAtmIfVptIispAddrPnniInfoStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIispAddrPnniInfo tables." ::= { mscAtmIfVptIispAddrPnniInfoRowStatusEntry 4 } mscAtmIfVptIispAddrPnniInfoIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptIispAddrPnniInfo tables." ::= { mscAtmIfVptIispAddrPnniInfoRowStatusEntry 10 } mscAtmIfVptIispAddrPnniInfoProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispAddrPnniInfoProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisioned attributes relating to PNNI for a PnniInfo component." ::= { mscAtmIfVptIispAddrPnniInfo 10 } mscAtmIfVptIispAddrPnniInfoProvEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispAddrPnniInfoProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispAddrPnniInfoProvTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispAddrAddressIndex, mscAtmIfVptIispAddrAddressTypeIndex, mscAtmIfVptIispAddrPnniInfoIndex } ::= { mscAtmIfVptIispAddrPnniInfoProvTable 1 } MscAtmIfVptIispAddrPnniInfoProvEntry ::= SEQUENCE { mscAtmIfVptIispAddrPnniInfoScope INTEGER, mscAtmIfVptIispAddrPnniInfoReachability INTEGER } mscAtmIfVptIispAddrPnniInfoScope OBJECT-TYPE SYNTAX INTEGER (-1..104) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the scope of the ATM address, which is the highest level up to which this address will be advertised in the PNNI hierarchy. The scope must be set to a value numerically less than or equal to the level of the lowest level peer group containing this node. Setting the scope to 0 will cause the address to be advertised globally within this PNNI routing domain." DEFVAL { -1 } ::= { mscAtmIfVptIispAddrPnniInfoProvEntry 1 } mscAtmIfVptIispAddrPnniInfoReachability OBJECT-TYPE SYNTAX INTEGER { internal(0), exterior(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute indicates whether the address is internal or exterior. An internal reachable address is an address of a destination that is directly attached to the logical node advertising the address. An exterior reachable address is an address that can be reached through a PNNI routing domain, but which is not located in that PNNI routing domain." DEFVAL { internal } ::= { mscAtmIfVptIispAddrPnniInfoProvEntry 2 } -- AtmIf/n Uni CallingAddressScreening -- AtmIf/n Iisp CallingAddressScreening -- This component represents the screening of incoming ATM SVC -- call requests against provisioned ATM calling addresses (that is, -- screening SVC calls coming from specific addresses). If this -- component is not provisioned, all call requests are accepted and no -- calling address screening takes place. mscAtmIfVptIispCallingAScr OBJECT IDENTIFIER ::= { mscAtmIfVptIisp 5 } mscAtmIfVptIispCallingAScrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispCallingAScrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIispCallingAScr components." ::= { mscAtmIfVptIispCallingAScr 1 } mscAtmIfVptIispCallingAScrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispCallingAScrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIispCallingAScr component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispCallingAScrIndex } ::= { mscAtmIfVptIispCallingAScrRowStatusTable 1 } MscAtmIfVptIispCallingAScrRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispCallingAScrRowStatus RowStatus, mscAtmIfVptIispCallingAScrComponentName DisplayString, mscAtmIfVptIispCallingAScrStorageType StorageType, mscAtmIfVptIispCallingAScrIndex NonReplicated } mscAtmIfVptIispCallingAScrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIispCallingAScr components. These components can be added and deleted." ::= { mscAtmIfVptIispCallingAScrRowStatusEntry 1 } mscAtmIfVptIispCallingAScrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispCallingAScrRowStatusEntry 2 } mscAtmIfVptIispCallingAScrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIispCallingAScr tables." ::= { mscAtmIfVptIispCallingAScrRowStatusEntry 4 } mscAtmIfVptIispCallingAScrIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptIispCallingAScr tables." ::= { mscAtmIfVptIispCallingAScrRowStatusEntry 10 } mscAtmIfVptIispCallingAScrProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispCallingAScrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes for the CallingAScr component." ::= { mscAtmIfVptIispCallingAScr 10 } mscAtmIfVptIispCallingAScrProvEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispCallingAScrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispCallingAScrProvTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispCallingAScrIndex } ::= { mscAtmIfVptIispCallingAScrProvTable 1 } MscAtmIfVptIispCallingAScrProvEntry ::= SEQUENCE { mscAtmIfVptIispCallingAScrAdminStatus INTEGER, mscAtmIfVptIispCallingAScrDefaultInsertionAddress HexString } mscAtmIfVptIispCallingAScrAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(0), disabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether the calling address screening feature is enabled or disabled. If enabled, incoming SVC calls are screened against provisioned addresses. If enabled and the calling address in the ATM SVC call request is provisioned to be accepted, the call is accepted or rejected according to the action specified for that address. If the value is enabled, and the calling address in the address request is not provisioned, the call is rejected If the value is disabled, no calling address screening is performed." DEFVAL { disabled } ::= { mscAtmIfVptIispCallingAScrProvEntry 1 } mscAtmIfVptIispCallingAScrDefaultInsertionAddress OBJECT-TYPE SYNTAX HexString (SIZE (0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the address to be inserted into the SVC connection request if adminStatus is enabled and the connection request does not contain a calling address. If the adminStatus attribute is enabled and this attribute is empty, all incoming SVC calls which do not contain a calling address are rejected." DEFVAL { ''H } -- "" ::= { mscAtmIfVptIispCallingAScrProvEntry 2 } mscAtmIfVptIispCallingAScrStatTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispCallingAScrStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains statistics related to the incoming SVC call requests received while the adminStatus attribute is set to enabled." ::= { mscAtmIfVptIispCallingAScr 11 } mscAtmIfVptIispCallingAScrStatEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispCallingAScrStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispCallingAScrStatTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispCallingAScrIndex } ::= { mscAtmIfVptIispCallingAScrStatTable 1 } MscAtmIfVptIispCallingAScrStatEntry ::= SEQUENCE { mscAtmIfVptIispCallingAScrAcceptedCalls Counter32, mscAtmIfVptIispCallingAScrRejectedCalls Counter32, mscAtmIfVptIispCallingAScrUnmatchedCalls Counter32 } mscAtmIfVptIispCallingAScrAcceptedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were accepted because the address specified in the call request matched a provisioned ATM address and the associated action was accept. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfVptIispCallingAScrStatEntry 1 } mscAtmIfVptIispCallingAScrRejectedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were rejected because the address specified in the call request matched a provisioned ATM address, but the associated action was reject. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfVptIispCallingAScrStatEntry 2 } mscAtmIfVptIispCallingAScrUnmatchedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were rejected because none of the provisioned ATM addresses matched the applicable address in the incoming SVC call request. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfVptIispCallingAScrStatEntry 3 } -- AtmIf/n Uni CallingAScr Address/addr,action -- AtmIf/n Iisp CallingAScr Address/addr,action -- AtmIf/n Uni CalledAScr Address/addr,action -- AtmIf/n Iisp CalledAScr Address/addr,action -- This component specifies a calling (or called) address with an -- action to accept or reject a connection request which contains a -- matching calling (or called) address. -- For the Calling Address Screening feature, if the specified action is -- accept, any call whose calling address matches that address is -- accepted. If the specified action is reject, any call whose calling -- address matches that address is rejected. -- For the Called Address Screening feature, if the specified action is -- accept, any call whose called address matches that address, is -- accepted. If the specified action is reject, any call whose called -- address matches that address is rejected. -- For both features, the incoming SVC call request is rejected if the -- address is not provisioned and the feature is enabled. mscAtmIfVptIispCallingAScrAddr OBJECT IDENTIFIER ::= { mscAtmIfVptIispCallingAScr 2 } mscAtmIfVptIispCallingAScrAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispCallingAScrAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIispCallingAScrAddr components." ::= { mscAtmIfVptIispCallingAScrAddr 1 } mscAtmIfVptIispCallingAScrAddrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispCallingAScrAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIispCallingAScrAddr component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispCallingAScrIndex, mscAtmIfVptIispCallingAScrAddrAddressIndex, mscAtmIfVptIispCallingAScrAddrAddressActionIndex } ::= { mscAtmIfVptIispCallingAScrAddrRowStatusTable 1 } MscAtmIfVptIispCallingAScrAddrRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispCallingAScrAddrRowStatus RowStatus, mscAtmIfVptIispCallingAScrAddrComponentName DisplayString, mscAtmIfVptIispCallingAScrAddrStorageType StorageType, mscAtmIfVptIispCallingAScrAddrAddressIndex AsciiStringIndex, mscAtmIfVptIispCallingAScrAddrAddressActionIndex INTEGER } mscAtmIfVptIispCallingAScrAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIispCallingAScrAddr components. These components can be added and deleted." ::= { mscAtmIfVptIispCallingAScrAddrRowStatusEntry 1 } mscAtmIfVptIispCallingAScrAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispCallingAScrAddrRowStatusEntry 2 } mscAtmIfVptIispCallingAScrAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIispCallingAScrAddr tables." ::= { mscAtmIfVptIispCallingAScrAddrRowStatusEntry 4 } mscAtmIfVptIispCallingAScrAddrAddressIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfVptIispCallingAScrAddr tables." ::= { mscAtmIfVptIispCallingAScrAddrRowStatusEntry 10 } mscAtmIfVptIispCallingAScrAddrAddressActionIndex OBJECT-TYPE SYNTAX INTEGER { accept(0), reject(1) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfVptIispCallingAScrAddr tables." ::= { mscAtmIfVptIispCallingAScrAddrRowStatusEntry 11 } -- AtmIf/n Uni CalledAddressScreening -- AtmIf/n Iisp CalledAddressScreening -- This component represents the screening of incoming ATM SVC -- call requests against provisioned ATM called addresses (that is, -- going to specific destinations). If this component is not provisioned, -- all call requests are accepted and no called address screening takes -- place. mscAtmIfVptIispCalledAScr OBJECT IDENTIFIER ::= { mscAtmIfVptIisp 6 } mscAtmIfVptIispCalledAScrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispCalledAScrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIispCalledAScr components." ::= { mscAtmIfVptIispCalledAScr 1 } mscAtmIfVptIispCalledAScrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispCalledAScrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIispCalledAScr component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispCalledAScrIndex } ::= { mscAtmIfVptIispCalledAScrRowStatusTable 1 } MscAtmIfVptIispCalledAScrRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispCalledAScrRowStatus RowStatus, mscAtmIfVptIispCalledAScrComponentName DisplayString, mscAtmIfVptIispCalledAScrStorageType StorageType, mscAtmIfVptIispCalledAScrIndex NonReplicated } mscAtmIfVptIispCalledAScrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIispCalledAScr components. These components can be added and deleted." ::= { mscAtmIfVptIispCalledAScrRowStatusEntry 1 } mscAtmIfVptIispCalledAScrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispCalledAScrRowStatusEntry 2 } mscAtmIfVptIispCalledAScrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIispCalledAScr tables." ::= { mscAtmIfVptIispCalledAScrRowStatusEntry 4 } mscAtmIfVptIispCalledAScrIndex OBJECT-TYPE SYNTAX NonReplicated ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents the index for the mscAtmIfVptIispCalledAScr tables." ::= { mscAtmIfVptIispCalledAScrRowStatusEntry 10 } mscAtmIfVptIispCalledAScrProvTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispCalledAScrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains the provisionable attributes for the CalledAScr component." ::= { mscAtmIfVptIispCalledAScr 10 } mscAtmIfVptIispCalledAScrProvEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispCalledAScrProvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispCalledAScrProvTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispCalledAScrIndex } ::= { mscAtmIfVptIispCalledAScrProvTable 1 } MscAtmIfVptIispCalledAScrProvEntry ::= SEQUENCE { mscAtmIfVptIispCalledAScrAdminStatus INTEGER } mscAtmIfVptIispCalledAScrAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(0), disabled(1) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies whether the called address screening feature is enabled or disabled. If the value is enabled, incoming SVC calls will be screened against provisioned called addresses. If the value is enabled and the called address in the ATM SVC call request has been provisioned, the call is accepted or rejected according to the action specified for that address. If the value is enabled and the called address in the call request is not provisioned, the call is rejected. If the value is disabled, no called address screening is performed." DEFVAL { disabled } ::= { mscAtmIfVptIispCalledAScrProvEntry 1 } mscAtmIfVptIispCalledAScrStatTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispCalledAScrStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This attribute group contains statistics related to the incoming SVC call requests received while the adminStatus attribute is set to enabled." ::= { mscAtmIfVptIispCalledAScr 11 } mscAtmIfVptIispCalledAScrStatEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispCalledAScrStatEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the mscAtmIfVptIispCalledAScrStatTable." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispCalledAScrIndex } ::= { mscAtmIfVptIispCalledAScrStatTable 1 } MscAtmIfVptIispCalledAScrStatEntry ::= SEQUENCE { mscAtmIfVptIispCalledAScrAcceptedCalls Counter32, mscAtmIfVptIispCalledAScrRejectedCalls Counter32, mscAtmIfVptIispCalledAScrUnmatchedCalls Counter32 } mscAtmIfVptIispCalledAScrAcceptedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were accepted because the address specified in the call request matched a provisioned ATM address and the associated action was accept. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfVptIispCalledAScrStatEntry 1 } mscAtmIfVptIispCalledAScrRejectedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were rejected because the address specified in the call request matched a provisioned ATM address, but the associated action was reject. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfVptIispCalledAScrStatEntry 2 } mscAtmIfVptIispCalledAScrUnmatchedCalls OBJECT-TYPE SYNTAX Counter32 ACCESS read-only STATUS mandatory DESCRIPTION "This attribute counts the incoming SVC calls which were rejected because none of the provisioned ATM addresses matched the applicable address in the incoming SVC call request. When the counter exceeds the maximum, it wraps to 0." ::= { mscAtmIfVptIispCalledAScrStatEntry 3 } -- AtmIf/n Uni CallingAScr Address/addr,action -- AtmIf/n Iisp CallingAScr Address/addr,action -- AtmIf/n Uni CalledAScr Address/addr,action -- AtmIf/n Iisp CalledAScr Address/addr,action -- This component specifies a calling (or called) address with an -- action to accept or reject a connection request which contains a -- matching calling (or called) address. -- For the Calling Address Screening feature, if the specified action is -- accept, any call whose calling address matches that address is -- accepted. If the specified action is reject, any call whose calling -- address matches that address is rejected. -- For the Called Address Screening feature, if the specified action is -- accept, any call whose called address matches that address, is -- accepted. If the specified action is reject, any call whose called -- address matches that address is rejected. -- For both features, the incoming SVC call request is rejected if the -- address is not provisioned and the feature is enabled. mscAtmIfVptIispCalledAScrAddr OBJECT IDENTIFIER ::= { mscAtmIfVptIispCalledAScr 2 } mscAtmIfVptIispCalledAScrAddrRowStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF MscAtmIfVptIispCalledAScrAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This entry controls the addition and deletion of mscAtmIfVptIispCalledAScrAddr components." ::= { mscAtmIfVptIispCalledAScrAddr 1 } mscAtmIfVptIispCalledAScrAddrRowStatusEntry OBJECT-TYPE SYNTAX MscAtmIfVptIispCalledAScrAddrRowStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A single entry in the table represents a single mscAtmIfVptIispCalledAScrAddr component." INDEX { mscAtmIfIndex, mscAtmIfVptIndex, mscAtmIfVptIispIndex, mscAtmIfVptIispCalledAScrIndex, mscAtmIfVptIispCalledAScrAddrAddressIndex, mscAtmIfVptIispCalledAScrAddrAddressActionIndex } ::= { mscAtmIfVptIispCalledAScrAddrRowStatusTable 1 } MscAtmIfVptIispCalledAScrAddrRowStatusEntry ::= SEQUENCE { mscAtmIfVptIispCalledAScrAddrRowStatus RowStatus, mscAtmIfVptIispCalledAScrAddrComponentName DisplayString, mscAtmIfVptIispCalledAScrAddrStorageType StorageType, mscAtmIfVptIispCalledAScrAddrAddressIndex AsciiStringIndex, mscAtmIfVptIispCalledAScrAddrAddressActionIndex INTEGER } mscAtmIfVptIispCalledAScrAddrRowStatus OBJECT-TYPE SYNTAX RowStatus ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used as the basis for SNMP naming of mscAtmIfVptIispCalledAScrAddr components. These components can be added and deleted." ::= { mscAtmIfVptIispCalledAScrAddrRowStatusEntry 1 } mscAtmIfVptIispCalledAScrAddrComponentName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This variable provides the component's string name for use with the ASCII Console Interface" ::= { mscAtmIfVptIispCalledAScrAddrRowStatusEntry 2 } mscAtmIfVptIispCalledAScrAddrStorageType OBJECT-TYPE SYNTAX StorageType ACCESS read-only STATUS mandatory DESCRIPTION "This variable represents the storage type value for the mscAtmIfVptIispCalledAScrAddr tables." ::= { mscAtmIfVptIispCalledAScrAddrRowStatusEntry 4 } mscAtmIfVptIispCalledAScrAddrAddressIndex OBJECT-TYPE SYNTAX AsciiStringIndex (SIZE (1..40)) ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfVptIispCalledAScrAddr tables." ::= { mscAtmIfVptIispCalledAScrAddrRowStatusEntry 10 } mscAtmIfVptIispCalledAScrAddrAddressActionIndex OBJECT-TYPE SYNTAX INTEGER { accept(0), reject(1) } ACCESS not-accessible STATUS mandatory DESCRIPTION "This variable represents an index for the mscAtmIfVptIispCalledAScrAddr tables." ::= { mscAtmIfVptIispCalledAScrAddrRowStatusEntry 11 } -- -- Version and Compliance statements -- -- Object-Group Statement: -- A list of all current accessible leaf objects. -- OBJECTS { mscAtmIfVptIispSoftPvpAndPvcRetryPeriod, -- mscAtmIfIispVersion, -- mscAtmIfVptIispSigVcdAtmServiceCategory, -- mscAtmIfIispAddrPnniInfoReachability, -- mscAtmIfIispSigCurrentPmpConnections, -- mscAtmIfVptIispServiceExchange, -- mscAtmIfIispSigNewCurrentConnections, -- mscAtmIfVptIispCallingAScrAcceptedCalls, -- mscAtmIfVptIispAddrPnniInfoRowStatus, -- mscAtmIfIispAddrRowStatus, -- mscAtmIfVptIispSigAdminState, -- mscAtmIfIispCalledAScrAcceptedCalls, -- mscAtmIfIispCalledAScrAddrStorageType, -- mscAtmIfIispSide, -- mscAtmIfIispSigAddressConversion, -- mscAtmIfIispComponentName, -- mscAtmIfVptIispSigRowStatus, -- mscAtmIfIispCalledAScrRejectedCalls, -- mscAtmIfVptIispCallingAScrAddrStorageType, -- mscAtmIfIispAddrTermSPStorageType, -- mscAtmIfVptIispSigVcdTrafficShaping, -- mscAtmIfIispSigVcdStorageType, -- mscAtmIfVptIispCallingAScrRowStatus, -- mscAtmIfVptIispSigOperatingMode, -- mscAtmIfIispAccountConnectionType, -- mscAtmIfVptIispCalledAScrAddrComponentName, -- mscAtmIfIispAddrPnniInfoStorageType, -- mscAtmIfIispSigFailedPmpConnections, -- mscAtmIfVptIispSigSuccessfulConnections, -- mscAtmIfVptIispCalledAScrRejectedCalls, -- mscAtmIfIispSigPeakPmpConnections, -- mscAtmIfIispSigRowStatus, -- mscAtmIfVptIispAddrRowStatus, -- mscAtmIfIispSigVci, -- mscAtmIfIispCalledAScrRowStatus, -- mscAtmIfIispCalledAScrUnmatchedCalls, -- mscAtmIfVptIispCallingAScrStorageType, -- mscAtmIfIispAddrScope, -- mscAtmIfVptIispSigVcdQosClass, -- mscAtmIfVptIispAddrComponentName, -- mscAtmIfIispSigVcdUnshapedTransmitQueueing, -- mscAtmIfIispAddrTermSPRowStatus, -- mscAtmIfIispSigComponentName, -- mscAtmIfIispSigVcdRowStatus, -- mscAtmIfVptIispSigFailedConnections, -- mscAtmIfVptIispSigCurrentPmpConnections, -- mscAtmIfVptIispCalledAScrAdminStatus, -- mscAtmIfIispCallingAScrComponentName, -- mscAtmIfVptIispSigVcdWeight, -- mscAtmIfVptIispSigVcdStorageType, -- mscAtmIfVptIispSigLastRxCauseCode, -- mscAtmIfVptIispAddrPnniInfoStorageType, -- mscAtmIfIispAddrPnniInfoRowStatus, -- mscAtmIfIispSigSuccessfulConnections, -- mscAtmIfIispSigOperatingMode, -- mscAtmIfVptIispSigAddressConversion, -- mscAtmIfVptIispCalledAScrStorageType, -- mscAtmIfVptIispCalledAScrAddrRowStatus, -- mscAtmIfVptIispAddrPnniInfoComponentName, -- mscAtmIfVptIispCallingAScrAddrRowStatus, -- mscAtmIfIispAccountCollection, -- mscAtmIfVptIispSigRxPdus, -- mscAtmIfVptIispAddrTermSPStorageType, -- mscAtmIfVptIispSide, -- mscAtmIfIispAddrStorageType, -- mscAtmIfIispStorageType, -- mscAtmIfVptIispAddrPnniInfoReachability, -- mscAtmIfIispSigRxPdus, -- mscAtmIfVptIispSigLastRxDiagCode, -- mscAtmIfVptIispCalledAScrUnmatchedCalls, -- mscAtmIfVptIispSigLastTxCauseCode, -- mscAtmIfVptIispSigPeakPmpConnections, -- mscAtmIfIispSigSuccessfulPmpConnections, -- mscAtmIfIispSigLastTxDiagCode, -- mscAtmIfIispAddrReachability, -- mscAtmIfVptIispVersion, -- mscAtmIfIispSigFailedConnections, -- mscAtmIfVptIispSigVcdTdpValue, -- mscAtmIfVptIispSigVcdTrafficDescType, -- mscAtmIfVptIispSigNewCurrentConnections, -- mscAtmIfIispCallingAScrAddrComponentName, -- mscAtmIfIispSigVcdUsageParameterControl, -- mscAtmIfIispRowStatus, -- mscAtmIfVptIispSigOperationalState, -- mscAtmIfVptIispCallingAScrComponentName, -- mscAtmIfIispCalledAScrStorageType, -- mscAtmIfIispCallingAScrAdminStatus, -- mscAtmIfIispSigStorageType, -- mscAtmIfIispSoftPvpAndPvcHoldOffTime, -- mscAtmIfIispCallingAScrAcceptedCalls, -- mscAtmIfIispCallingAScrDefaultInsertionAddress, -- mscAtmIfVptIispComponentName, -- mscAtmIfVptIispAccountClass, -- mscAtmIfIispSoftPvpAndPvcRetryPeriod, -- mscAtmIfVptIispVpci, -- mscAtmIfIispSigVcdAtmServiceCategory, -- mscAtmIfIispAddrPnniInfoScope, -- mscAtmIfVptIispCalledAScrComponentName, -- mscAtmIfVptIispCallingAScrRejectedCalls, -- mscAtmIfIispServiceExchange, -- mscAtmIfVptIispAccountConnectionType, -- mscAtmIfVptIispAddrPnniInfoScope, -- mscAtmIfIispSigAdminState, -- mscAtmIfVptIispSigFailedPmpConnections, -- mscAtmIfVptIispAddrTermSPComponentName, -- mscAtmIfIispAccountClass, -- mscAtmIfIispCallingAScrUnmatchedCalls, -- mscAtmIfIispSigVcdTdpValue, -- mscAtmIfVptIispSigVci, -- mscAtmIfVptIispCalledAScrRowStatus, -- mscAtmIfVptIispSigSuccessfulPmpConnections, -- mscAtmIfIispSigVcdTrafficDescType, -- mscAtmIfVptIispCallingAScrAddrComponentName, -- mscAtmIfVptIispSigVcdUnshapedTransmitQueueing, -- mscAtmIfVptIispAddrTermSPRowStatus, -- mscAtmIfVptIispSigComponentName, -- mscAtmIfVptIispSigVcdRowStatus, -- mscAtmIfIispAddrComponentName, -- mscAtmIfIispSigUsageState, -- mscAtmIfVptIispSigPeakConnections, -- mscAtmIfIispCalledAScrAddrRowStatus, -- mscAtmIfIispSigVcdWeight, -- mscAtmIfVptIispAddrScope, -- mscAtmIfVptIispSigTxPdus, -- mscAtmIfIispSigTxPdus, -- mscAtmIfIispSigLastRxCauseCode, -- mscAtmIfIispCallingAScrAddrStorageType, -- mscAtmIfIispCallingAScrStorageType, -- mscAtmIfVptIispSigVcdComponentName, -- mscAtmIfIispSigVcdQosClass, -- mscAtmIfVptIispSigUsageState, -- mscAtmIfVptIispAccountCollection, -- mscAtmIfIispCallingAScrRejectedCalls, -- mscAtmIfIispCalledAScrAddrComponentName, -- mscAtmIfIispSigOperationalState, -- mscAtmIfVptIispCallingAScrUnmatchedCalls, -- mscAtmIfVptIispAddrStorageType, -- mscAtmIfVptIispStorageType, -- mscAtmIfIispCalledAScrComponentName, -- mscAtmIfIispCalledAScrAdminStatus, -- mscAtmIfVptIispCalledAScrAcceptedCalls, -- mscAtmIfIispAddrTermSPComponentName, -- mscAtmIfIispSigVcdComponentName, -- mscAtmIfIispSigPeakConnections, -- mscAtmIfVptIispSigVcdUsageParameterControl, -- mscAtmIfVptIispAddrReachability, -- mscAtmIfIispAddrPnniInfoComponentName, -- mscAtmIfVptIispCalledAScrAddrStorageType, -- mscAtmIfIispCallingAScrAddrRowStatus, -- mscAtmIfIispCallingAScrRowStatus, -- mscAtmIfIispSigVcdTrafficShaping, -- mscAtmIfVptIispSigLastTxDiagCode, -- mscAtmIfIispSigLastRxDiagCode, -- mscAtmIfVptIispRowStatus, -- mscAtmIfVptIispCallingAScrAdminStatus, -- mscAtmIfIispSigLastTxCauseCode, -- mscAtmIfVptIispSigStorageType, -- mscAtmIfVptIispSoftPvpAndPvcHoldOffTime, -- mscAtmIfVptIispCallingAScrDefaultInsertionAddress } -- STATUS mandatory -- DESCRIPTION -- "A list of all current accessible leaf objects." atmIispGroup OBJECT IDENTIFIER ::= { atmIispMIB 1 } atmIispGroupCA OBJECT IDENTIFIER ::= { atmIispGroup 1 } atmIispGroupCA02 OBJECT IDENTIFIER ::= { atmIispGroupCA 3 } atmIispGroupCA02A OBJECT IDENTIFIER ::= { atmIispGroupCA02 2 } -- Agent-Capabilities Statement: -- PRODUCT-RELEASE "MscPassport Release 1.2 AtmIisp." -- STATUS mandatory -- DESCRIPTION "Carrier Passport AtmIisp MIB: MIB Version CA02A, -- Software Version CA02S9C." -- SUPPORTS Nortel-MsCarrier-MscPassport-AtmIispMIB -- INCLUDES { atmIispGroupCA02A } atmIispCapabilities OBJECT IDENTIFIER ::= { atmIispMIB 3 } atmIispCapabilitiesCA OBJECT IDENTIFIER ::= { atmIispCapabilities 1 } atmIispCapabilitiesCA02 OBJECT IDENTIFIER ::= { atmIispCapabilitiesCA 3 } atmIispCapabilitiesCA02A OBJECT IDENTIFIER ::= { atmIispCapabilitiesCA02 2 } END