All MIBs › NORTEL-NMI-FAULT-NOTI-MIB › nortelNMIalarmClearNotification
nortelNMIalarmClearNotification
Module: NORTEL-NMI-FAULT-NOTI-MIB
OID (symbolic): NORTEL-NMI-FAULT-NOTI-MIB::nortelNMIalarmClearNotification
OID (numeric): 1.3.6.1.4.1.562.29.1.6.4.0.201
Node type: NOTIFICATION-TYPE
Description: This notification indicates that one or more previously reported alarms have been cleared and the previously reported alarms are identified via the correlation id list field. The varbinds include alarm context via the ComponentId field and other additional useful information.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' NORTEL-NMI-FAULT-NOTI-MIB::nortelNMIalarmClearNotification snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.562.29.1.6.4.0.201
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:63553->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (151904833) 17 days, 13:57:28.33 SNMPv2-MIB::snmpTrapOID.0 = OID: NORTEL-NMI-FAULT-NOTI-MIB::nortelNMIalarmClearNotification
Start monitoring Nortel (Avaya) networking equipment (NMI fault notifications) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NORTEL-NMI-FAULT-NOTI-MIB::nortelNMIalarmClearNotification OID value, configure state conditions and alerts, and monitor any Nortel (Avaya) networking equipment (NMI fault notifications) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.29 | nortelGenericMIBs | NORTEL-GENERIC-MIB |
| 1.3.6.1.4.1.562.29.1 | nortelNetworkManagementInterfaceMIBs | NORTEL-GENERIC-MIB |
| 1.3.6.1.4.1.562.29.1.6 | nortelNMInotificationsMIB | NORTEL-NMI-NOTIFICATIONS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.29.1.6.4 | nortelNMIfaultNotiMIB | NORTEL-NMI-FAULT-NOTI-MIB |
| 1.3.6.1.4.1.562.29.1.6.4.0 | nortelNMIfaultNotiPrefix | NORTEL-NMI-FAULT-NOTI-MIB |
| 1.3.6.1.4.1.562.29.1.6.4.0.201 | nortelNMIalarmClearNotification | NORTEL-NMI-FAULT-NOTI-MIB |