NMS-EPON-ONU-PARAM :: temperatureAlarmUpLimitEnable

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › NMS-EPON-ONU-PARAM › temperatureAlarmUpLimitEnable

temperatureAlarmUpLimitEnable

Module: NMS-EPON-ONU-PARAM

OID (symbolic): NMS-EPON-ONU-PARAM::temperatureAlarmUpLimitEnable

OID (numeric): 1.3.6.1.4.1.11606.10.101.201.1.1.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Enable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable.

What is temperatureAlarmUpLimitEnable?

Enables or disables raising an alarm when this ONU's temperature climbs above the configured upper threshold; disabled by default.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11606.10.101.201.1.1.1.10
snmpwalk -v2c -c public <target> NMS-EPON-ONU-PARAM::temperatureAlarmUpLimitEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11606.10.101.201.1.1.1.10.1
snmpget -v2c -c public <target> NMS-EPON-ONU-PARAM::temperatureAlarmUpLimitEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11606.10.101.201.1.1.1.10.1 i <value>

Start monitoring NMS Communications EPON ONU customer-premises equipment (alarm thresholds) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NMS-EPON-ONU-PARAM::temperatureAlarmUpLimitEnable OID value, configure state conditions and alerts, and monitor any NMS Communications EPON ONU customer-premises equipment (alarm thresholds) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11606pbnPBN-ROOT
1.3.6.1.4.1.11606.10nmsNMS-SMI
1.3.6.1.4.1.11606.10.101nmsEPONGroupNMS-SMI
Numeric OIDNameModule
1.3.6.1.4.1.11606.10.101.201nmsOnuPerfNMS-EPON-ONU-PARAM
1.3.6.1.4.1.11606.10.101.201.1nmsOnuPerfSetNMS-EPON-ONU-PARAM
1.3.6.1.4.1.11606.10.101.201.1.1onuPerformParameterAlarmsSetTableNMS-EPON-ONU-PARAM
1.3.6.1.4.1.11606.10.101.201.1.1.1onuPerformParameterAlarmsSetEntryNMS-EPON-ONU-PARAM
1.3.6.1.4.1.11606.10.101.201.1.1.1.10temperatureAlarmUpLimitEnableNMS-EPON-ONU-PARAM