Description: NAME = ; DESC = When switch type is FRDCE, the \ ifIndex of the local DCE interface. \ (Analogous to the ifIndex pointer in \ MIB II Interfaces Group, but specific \ to the FR End-to-End Connections \ table.) When switch type is HTDS, the \ ifIndex of the local WAN interface. \ (Operational); HELP = ; CAPABILITIES = ;
What is mcmFrConnectIfIndexLocal?
Identifies, together with mcmFrConnectDLCILocal, which local Frame Relay DCE interface row a given end-to-end SPVC mapping belongs to. On an FRDCE switch type this is the ifIndex of the local DCE interface (paralleling ifIndex in the standard Interfaces table), while on an HTDS switch type it instead points to the local WAN interface, so an admin reads this alongside the switch type to know which interface a specific circuit terminates on.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.335.1.4.9.1.1.1.1 snmpwalk -v2c -c public <target> MICOM-FRDCE-MIB::mcmFrConnectIfIndexLocal
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.335.1.4.9.1.1.1.1.1 snmpget -v2c -c public <target> MICOM-FRDCE-MIB::mcmFrConnectIfIndexLocal.1
Start monitoring MICOM Communications Frame Relay switching equipment (SPVC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MICOM-FRDCE-MIB::mcmFrConnectIfIndexLocal OID value, configure state conditions and alerts, and monitor any MICOM Communications Frame Relay switching equipment (SPVC) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.335 | micom | MICOM-OSCAR-MIB |
| 1.3.6.1.4.1.335.1 | products | MICOM-OSCAR-MIB |
| 1.3.6.1.4.1.335.1.4 | micom_oscar | MICOM-OSCAR-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.335.1.4.9 | micom_frdce | MICOM-FRDCE-MIB |
| 1.3.6.1.4.1.335.1.4.9.1 | frdce_configuration | MICOM-FRDCE-MIB |
| 1.3.6.1.4.1.335.1.4.9.1.1 | mcmFrConnectTable | MICOM-FRDCE-MIB |
| 1.3.6.1.4.1.335.1.4.9.1.1.1 | mcmFrConnectEntry | MICOM-FRDCE-MIB |
| 1.3.6.1.4.1.335.1.4.9.1.1.1.1 | mcmFrConnectIfIndexLocal | MICOM-FRDCE-MIB |