ME1200-QOS-MIB :: me1200QosQceInnerVlanId

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ME1200-QOS-MIB › me1200QosQceInnerVlanId

me1200QosQceInnerVlanId

Module: ME1200-QOS-MIB

OID (symbolic): ME1200-QOS-MIB::me1200QosQceInnerVlanId

OID (numeric): 1.3.6.1.4.1.9.9.815.1.14.1.2.1.10.1.1.18

Node type: OBJECT-TYPE

Type: ME1200Unsigned16

Access: read-write

Description: The inner VLAN ID to be compared. If the InnerVlanIdOp object in the same row is range(2), this object will be the starting VLAN ID of the range. Valid range is 1-4095. This object can only be configured if InnerVlanIdOp is not any(0).

What is me1200QosQceInnerVlanId?

The inner VLAN ID to match, or start of a range; same 1-4095 range and same any(0)-gating as the outer VlanId, but applies to the customer VLAN carried inside a Q-in-Q frame.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.815.1.14.1.2.1.10.1.1.18
snmpwalk -v2c -c public <target> ME1200-QOS-MIB::me1200QosQceInnerVlanId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.815.1.14.1.2.1.10.1.1.18.1
snmpget -v2c -c public <target> ME1200-QOS-MIB::me1200QosQceInnerVlanId.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.815.1.14.1.2.1.10.1.1.18.1 i <value>

Start monitoring Cisco ME1200 carrier Ethernet switch (storm control/WRED QoS) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ME1200-QOS-MIB::me1200QosQceInnerVlanId OID value, configure state conditions and alerts, and monitor any Cisco ME1200 carrier Ethernet switch (storm control/WRED QoS) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.815ciscoME1200MIBCISCOME1200-MIB
1.3.6.1.4.1.9.9.815.1me1200SwitchMgmtCISCOME1200-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.815.1.14me1200QosMIBME1200-QOS-MIB
1.3.6.1.4.1.9.9.815.1.14.1me1200QosMIBObjectsME1200-QOS-MIB
1.3.6.1.4.1.9.9.815.1.14.1.2me1200QosConfigME1200-QOS-MIB
1.3.6.1.4.1.9.9.815.1.14.1.2.1me1200QosGlobalsME1200-QOS-MIB
1.3.6.1.4.1.9.9.815.1.14.1.2.1.10me1200QosQceME1200-QOS-MIB
1.3.6.1.4.1.9.9.815.1.14.1.2.1.10.1me1200QosQceTableME1200-QOS-MIB
1.3.6.1.4.1.9.9.815.1.14.1.2.1.10.1.1me1200QosQceEntryME1200-QOS-MIB
1.3.6.1.4.1.9.9.815.1.14.1.2.1.10.1.1.18me1200QosQceInnerVlanIdME1200-QOS-MIB