ME1200-ACL-MIB :: me1200AclAceArpFlagRequest

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ME1200-ACL-MIB › me1200AclAceArpFlagRequest

me1200AclAceArpFlagRequest

Module: ME1200-ACL-MIB

OID (symbolic): ME1200-ACL-MIB::me1200AclAceArpFlagRequest

OID (numeric): 1.3.6.1.4.1.9.9.815.1.17.1.2.1.2.1.1.608

Node type: OBJECT-TYPE

Type: ME1200AclAceFlagOpcode

Access: read-write

Description: Indicates how a ARP packet's request/reply opcode is to be compared. The value 0 means any ARP opcode is allowed (don't-care field), value 1 means ARP opcode is equal to request opcode and value 2 means ARP opcode is equal to reply opcode. This object can only be configured if FrameType is arp(4).

What is me1200AclAceArpFlagRequest?

Checks the ARP packet's request/reply opcode against a fixed value: 0 ignores it, 1 requires the opcode is a request, and 2 requires it is a reply; helps write ACEs that trigger only on ARP requests, e.g. for ARP-spoofing detection.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.815.1.17.1.2.1.2.1.1.608
snmpwalk -v2c -c public <target> ME1200-ACL-MIB::me1200AclAceArpFlagRequest

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.815.1.17.1.2.1.2.1.1.608.1
snmpget -v2c -c public <target> ME1200-ACL-MIB::me1200AclAceArpFlagRequest.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.815.1.17.1.2.1.2.1.1.608.1 s <value>

Start monitoring Cisco ME1200 Metro Ethernet access switch (ACL/rate limiter) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ME1200-ACL-MIB::me1200AclAceArpFlagRequest OID value, configure state conditions and alerts, and monitor any Cisco ME1200 Metro Ethernet access switch (ACL/rate limiter) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.815ciscoME1200MIBCISCOME1200-MIB
1.3.6.1.4.1.9.9.815.1me1200SwitchMgmtCISCOME1200-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.815.1.17me1200AclMIBME1200-ACL-MIB
1.3.6.1.4.1.9.9.815.1.17.1me1200AclMIBObjectsME1200-ACL-MIB
1.3.6.1.4.1.9.9.815.1.17.1.2me1200AclConfigME1200-ACL-MIB
1.3.6.1.4.1.9.9.815.1.17.1.2.1me1200AclGlobalsME1200-ACL-MIB
1.3.6.1.4.1.9.9.815.1.17.1.2.1.2me1200AclAceME1200-ACL-MIB
1.3.6.1.4.1.9.9.815.1.17.1.2.1.2.1me1200AclAceTableME1200-ACL-MIB
1.3.6.1.4.1.9.9.815.1.17.1.2.1.2.1.1me1200AclAceEntryME1200-ACL-MIB
1.3.6.1.4.1.9.9.815.1.17.1.2.1.2.1.1.608me1200AclAceArpFlagRequestME1200-ACL-MIB