LaserJet-Series8000-MIB :: jetsend_contact_password

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsLaserJet-Series8000-MIBjetsend_contact_password

jetsend_contact_password

Module: LaserJet-Series8000-MIB

OID (symbolic): LaserJet-Series8000-MIB::jetsend_contact_password

OID (numeric): 1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3.1.1

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: write-only

Description: A C structure containing the following fields: typedef struct { ubyte old_password[8]; ubyte new_password[8];/ } jetsend_change_contact_password_t; where ubyte is an unsigned byte (0-255). Additional information: Controls access to the JetSend processing subsystem. Password absence/presence determines whether the device will allow a session to be established. The following C data structure contains the relevant fields (described in subsequent paragraphs): typedef struct { unsigned char old_password[8]; unsigned char new_password[8]; } Whenever the password is disabled (i.e., is zero-filled for its entire length), the device is indicating its willingness to allow session establishment. Whenever the password is enabled (i.e., has one or more non-zero-filled values), the device is controlling session establishment -- all in-progress JetSend sessions must supply a matching password or the device will reject the in-progress session. To disable the password, specify the matching password via the 'old_password' field and zero-fill the 'new_password' field. To enable the password for the first time, zero-fill the 'old_password' field and specify the new password via the 'new_password' field (the new password should not be zero-filled; otherwise, the password will remain disabled). To enable or change the password thereafter, specify the matching password via the 'old_password' field and specify the new password via the 'new_password' field (the new desired password should not be zero-filled; otherwise, the password will be disabled). To determine if the password is enabled, zero-fill both the 'old_password' and 'new_password' fields. If an error occurs, the password is enabled; otherwise, the password is disabled. (Specifying either an 'old_password' or 'new_password' fields greater than eight (8) bytes causes the error to be returned.) This object will be enabled in IR devices even if is does not detect an EIO card.

OID Breakdown

Upper-level ancestors (17 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9net_peripheralCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4netdmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2dmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1deviceCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.3processing_subsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.3.8jetsend_proc_subCLJ8550-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3jetsend_contactCLJ8550-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3.1settings_jetsend_contactCLJ8550-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3.1.1jetsend_contact_passwordLaserJet-Series8000-MIB