LaserJet-Series-5000-MIB :: jetsend_contact_password

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsLaserJet-Series-5000-MIBjetsend_contact_password

jetsend_contact_password

Module: LaserJet-Series-5000-MIB

OID (symbolic): LaserJet-Series-5000-MIB::jetsend_contact_password

OID (numeric): 1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3.1.1

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: write-only

Description: A C structure containing the following fields: typedef struct { ubyte old_password[8]; ubyte new_password[8];/ } jetsend_change_contact_password_t; where ubyte is an unsigned byte (0-255). Additional information: Controls access to the JetSend processing subsystem. Password absence/presence determines whether the device will allow a session to be established. The following C data structure contains the relevant fields (described in subsequent paragraphs): typedef struct { unsigned char old_password[8]; unsigned char new_password[8]; } Whenever the password is disabled (i.e., is zero-filled for its entire length), the device is indicating its willingness to allow session establishment. Whenever the password is enabled (i.e., has one or more non-zero-filled values), the device is controlling session establishment -- all in-progress JetSend sessions must supply a matching password or the device will reject the in-progress session. To disable the password, specify the matching password via the 'old_password' field and zero-fill the 'new_password' field. To enable the password for the first time, zero-fill the 'old_password' field and specify the new password via the 'new_password' field (the new password should not be zero-filled; otherwise, the password will remain disabled). To enable or change the password thereafter, specify the matching password via the 'old_password' field and specify the new password via the 'new_password' field (the new desired password should not be zero-filled; otherwise, the password will be disabled). To determine if the password is enabled, zero-fill both the 'old_password' and 'new_password' fields. If an error occurs, the password is enabled; otherwise, the password is disabled. (Specifying either an 'old_password' or 'new_password' fields greater than eight (8) bytes causes the error to be returned.)

OID Breakdown

Upper-level ancestors (17 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9net_peripheralCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4netdmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2dmCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1deviceCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.3processing_subsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.3.8jetsend_proc_subCLJ8550-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3jetsend_contactCLJ8550-MIB
1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3.1settings_jetsend_contactCLJ8550-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.9.4.2.1.3.8.3.1.1jetsend_contact_passwordLaserJet-Series-5000-MIB