ifOtnMonTraceOpSpecificTraceTransmitted

Module: LUM-IFOTNMON-MIB

OID (symbolic): LUM-IFOTNMON-MIB::ifOtnMonTraceOpSpecificTraceTransmitted

OID (numeric): 1.3.6.1.4.1.8708.2.55.2.5.1.1.13

Node type: OBJECT-TYPE

Type: DisplayStringWithNA

Access: read-write

Description: The operator specific trace identifier to be transmitted from this interface.

Set to empty string for default value.

<IP address>:<subrack>:<slot>:<port>

Note that only the last part of the address is used.

The trace _notApplicable_ is used to tell SNMP clients that this attribute is not used in current configuration.

The trace _notAvailable_ is used to tell SNMP clients that this attribute is not possible to read at the moment.

What is ifOtnMonTraceOpSpecificTraceTransmitted?

An operator-specific trace identifier, up to 32 characters, transmitted from this interface, typically formatted as an IP address plus subrack:slot:port (only the last part of the address is actually used). An admin leaves this at its empty default unless the operator has a specific need to embed extra site/port identification beyond the standard SAPI/DAPI trace.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8708.2.55.2.5.1.1.13
snmpwalk -v2c -c public <target> LUM-IFOTNMON-MIB::ifOtnMonTraceOpSpecificTraceTransmitted

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8708.2.55.2.5.1.1.13.1
snmpget -v2c -c public <target> LUM-IFOTNMON-MIB::ifOtnMonTraceOpSpecificTraceTransmitted.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.8708.2.55.2.5.1.1.13.1 s <value>

Start monitoring Infinera optical transport network (OTN) equipment (SM/TCM/PM monitoring) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LUM-IFOTNMON-MIB::ifOtnMonTraceOpSpecificTraceTransmitted OID value, configure state conditions and alerts, and monitor any Infinera optical transport network (OTN) equipment (SM/TCM/PM monitoring) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8708lumentisLUM-REG
1.3.6.1.4.1.8708.2lumGenericLUM-REG
1.3.6.1.4.1.8708.2.55lumIfOtnMonMIBLUM-REG
Numeric OIDNameModule
1.3.6.1.4.1.8708.2.55.2lumIfOtnMonMIBObjectsLUM-IFOTNMON-MIB
1.3.6.1.4.1.8708.2.55.2.5ifOtnMonTraceListLUM-IFOTNMON-MIB
1.3.6.1.4.1.8708.2.55.2.5.1ifOtnMonTraceTableLUM-IFOTNMON-MIB
1.3.6.1.4.1.8708.2.55.2.5.1.1ifOtnMonTraceEntryLUM-IFOTNMON-MIB
1.3.6.1.4.1.8708.2.55.2.5.1.1.13ifOtnMonTraceOpSpecificTraceTransmittedLUM-IFOTNMON-MIB