All MIBs › LIVINGSTON-PM4-MIB › lucentPM4ChasCmdBoardId
lucentPM4ChasCmdBoardId
Module: LIVINGSTON-PM4-MIB
OID (symbolic): LIVINGSTON-PM4-MIB::lucentPM4ChasCmdBoardId
OID (numeric): 1.3.6.1.4.1.307.1.1.2.1.3.2.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This object specifies the board for which the command is to be applied. The values for this object is limited to the Max number of boards.
What is lucentPM4ChasCmdBoardId?
Identifies which board in the chassis a scheduled command (in lucentPM4ChasCmdId) should be applied to, limited to the maximum number of boards the chassis supports. This is set alongside lucentPM4ChasCmdIndex when queuing an action like erasing flash or resetting a specific card.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.307.1.1.2.1.3.2.1.2 snmpwalk -v2c -c public <target> LIVINGSTON-PM4-MIB::lucentPM4ChasCmdBoardId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.307.1.1.2.1.3.2.1.2.1 snmpget -v2c -c public <target> LIVINGSTON-PM4-MIB::lucentPM4ChasCmdBoardId.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.307.1.1.2.1.3.2.1.2.1 i <value>
Start monitoring Lucent/Livingston PortMaster remote access servers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIVINGSTON-PM4-MIB::lucentPM4ChasCmdBoardId OID value, configure state conditions and alerts, and monitor any Lucent/Livingston PortMaster remote access servers from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.307 | livingston | LIVINGSTON-SNMP |
| 1.3.6.1.4.1.307.1 | product | LIVINGSTON-ROOT-MIB |
| 1.3.6.1.4.1.307.1.1 | lucentPMProduct | LIVINGSTON-ROOT-MIB |
| 1.3.6.1.4.1.307.1.1.2 | lucentPM4 | LIVINGSTON-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.307.1.1.2.1 | lucentPM4Mib | LIVINGSTON-PM4-MIB |
| 1.3.6.1.4.1.307.1.1.2.1.3 | lucentPM4Chassis | LIVINGSTON-PM4-MIB |
| 1.3.6.1.4.1.307.1.1.2.1.3.2 | lucentPM4ChasCmdTable | LIVINGSTON-PM4-MIB |
| 1.3.6.1.4.1.307.1.1.2.1.3.2.1 | lucentPM4ChasCmdEntry | LIVINGSTON-PM4-MIB |
| 1.3.6.1.4.1.307.1.1.2.1.3.2.1.2 | lucentPM4ChasCmdBoardId | LIVINGSTON-PM4-MIB |