LIVINGSTON-PM4-MIB DEFINITIONS ::= BEGIN IMPORTS IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress, sysName FROM RFC1213-MIB lucentPM4 FROM LIVINGSTON-ROOT-MIB; -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent PortMaster private MIB Begin Textual Conventions -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent PortMaster Equipment Types PMUnitType ::= INTEGER { mrgmodule(1), quadt1(2), trie1(3), modem(4), serialport(5), ether0(6), ether1(7), console(8), acpwrsup(9), fan(10), dcpwrsup(11), allunits(255) } PMEquipPRIStatus ::= INTEGER { up(1), down(2), loopback(3), fault(4) } PMEquipStatus ::= INTEGER { up(1), down(2), maintenance(3), fault(4), other(5) } PMDiagCmdStatus ::= INTEGER { success(1), fail(2), inprogress(3), notsupported(4), aborted(5), other(6) } PMDiagTestCntrl ::= INTEGER { normal(1), start(2), stop(3), abort(4) } PMAlarmType ::= INTEGER { informational(1), warning(2), minor(3), major(4), critical(5) } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent PortMaster private MIB End of Textual Conventions -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent PortMaster 4 Enterprise MIB -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4Mib OBJECT IDENTIFIER ::= { lucentPM4 1 } lucentPM4Traps OBJECT IDENTIFIER ::= { lucentPM4 2 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent MIB Information Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4MibRev OBJECT-TYPE SYNTAX DisplayString (SIZE(1..6)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the current MIB revision number. Example of the MIB revision can be PM4xxx for PM4 product and PM3xxx for PM3 products etc. Where xxx can be any combination of alpha-numeric characters." ::= { lucentPM4Mib 1 } lucentPM4SWRev OBJECT-TYPE SYNTAX DisplayString (SIZE(1..10)) ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the ComOS revision number. Example of the ComOS revision can be ComOS4.xx. Where xxx can be any combination of alpha-numeric characters." ::= { lucentPM4Mib 2 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent chassis Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4Chassis OBJECT IDENTIFIER ::= { lucentPM4Mib 3 } lucentPM4ChasSummary OBJECT-TYPE SYNTAX DisplayString (SIZE(55)) ACCESS read-only STATUS mandatory DESCRIPTION "This object provides general information about the PortMaster 4 chassis operational status. This object is read-only. The DisplayString represents a summary of all the devices in the chassis as follows: Bytes 1 - 2 '0''0' Byte 3 'U', 'D', 'M', 'F', 'O' Byte 4 space Bytes 5 - 6 '0''1' Byte 7 'U', 'D', 'M', 'F', 'O' Byte 8 space Bytes 9 - 10 '0''2' Byte 11 'U', 'D', 'M', 'F', 'O' Byte 12 space Bytes 13 - 14 '0''3' Byte 15 'U', 'D', 'M', 'F', 'O' Byte 16 space Bytes 17 - 18 '0''4' Byte 19 'U', 'D', 'M', 'F', 'O' Byte 20 space Bytes 21 - 22 '0''5' Byte 23 'U', 'D', 'M', 'F', 'O' Byte 24 space Bytes 25 - 26 '0''6' Byte 27 'U', 'D', 'M', 'F', 'O' Byte 28 space Bytes 29 - 30 '0''7' Byte 31 'U', 'D', 'M', 'F', 'O' Byte 32 space Bytes 33 - 34 '0''8' Byte 35 'U', 'D', 'M', 'F', 'O' Byte 36 space Bytes 37 - 38 '0''9' Byte 39 'U', 'D', 'M', 'F', 'O' Byte 40 space Bytes 41 - 42 '1''0' Byte 43 'U', 'D', 'M', 'F', 'O' Byte 44 space Bytes 45 - 46 '1''1' Byte 47 'U', 'D', 'M', 'F', 'O' Byte 48 space Bytes 49 - 50 '1''2' Byte 51 'U', 'D', 'M', 'F', 'O' Byte 52 space Bytes 53 - 54 '1''3' Byte 55 'U', 'D', 'M', 'F', 'O' Byte 56 space Bytes 57 - 58 '1''4' Byte 59 'U', 'D', 'M', 'F', 'O' Byte 60 space Bytes 61 - 62 '1''5' Byte 63 'U', 'D', 'M', 'F', 'O' Byte 64 space Bytes 65 - 66 'P''1' Byte 67 'U', 'D', 'M', 'F', 'O' Byte 68 space Bytes 69 - 70 'P''2' Byte 71 'U', 'D', 'M', 'F', 'O' Byte 72 space Bytes 73 - 74 'P''3' Byte 75 'U', 'D', 'M', 'F', 'O' Byte 76 space Bytes 77 - 78 'D''1' Byte 79 'U', 'D', 'M', 'F', 'O' Byte 80 space Bytes 81 - 82 'D''2' Byte 83 'U', 'D', 'M', 'F', 'O' Byte 84 space Bytes 85 - 86 'F''1' Byte 87 'U', 'D', 'M', 'F', 'O' Byte 88 space Bytes 89 - 90 'F''2' Byte 91 'U', 'D', 'M', 'F', 'O' Byte 92 space Bytes 93 - 94 'F''3' Byte 95 'U', 'D', 'M', 'F', 'O' Byte 96 space Bytes 97 - 98 'F''4' Byte 99 'U', 'D', 'M', 'F', 'O' Legend '#''#' Represents the board number 'F''#' Represents the Fan # 'P''#' Represents the Power Supply # 'D''#' Represents the DC Power Supply # 'U' Up 'D' Down 'M' Maintenance 'F' Failed 'O' Other unknown state." ::= { lucentPM4Chassis 1 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Chassis Command Table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4ChasCmdTable OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4ChasCmdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table describing the commands that can be issued to the agent to perform specific actions to any card, port or device in the system. For example to erase the flash or a particular file from the flash. Note that only a station configured with the appropriate authentication string can issue commands to the agent." ::= { lucentPM4Chassis 2 } lucentPM4ChasCmdEntry OBJECT-TYPE SYNTAX LucentPM4ChasCmdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the command table for the chassis commands. This describes one entry or row in the command table." INDEX { lucentPM4ChasCmdIndex } ::= { lucentPM4ChasCmdTable 1 } LucentPM4ChasCmdEntry ::= SEQUENCE { lucentPM4ChasCmdIndex INTEGER, lucentPM4ChasCmdBoardId INTEGER, lucentPM4ChasCmdUnitType PMUnitType, lucentPM4ChasCmdUnitIndex INTEGER, lucentPM4ChasCmdDevId INTEGER, lucentPM4ChasCmdId INTEGER, lucentPM4ChasCmdParams OCTET STRING, lucentPM4ChasCmdResult INTEGER } lucentPM4ChasCmdIndex OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the index in the command table. The values for this object is limited to the size of the command table on the network element. The size of the command table is set to 10 which can be changed if and when users need to schedule more than 10 commands at a given time." ::= { lucentPM4ChasCmdEntry 1 } lucentPM4ChasCmdBoardId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the board for which the command is to be applied. The values for this object is limited to the Max number of boards." ::= { lucentPM4ChasCmdEntry 2 } lucentPM4ChasCmdUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the type of the device to which this command must apply." ::= { lucentPM4ChasCmdEntry 3 } lucentPM4ChasCmdUnitIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the interface index." ::= { lucentPM4ChasCmdEntry 4 } lucentPM4ChasCmdDevId OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the sub-unit id for which the command must be applied to. This value will be used by the agent to index to the correct sub-device on a board. For example, this object can have values from 1 - 96 for the modems or 1 - 4 for T1 or 1 - 3 for the E1." ::= { lucentPM4ChasCmdEntry 5 } lucentPM4ChasCmdId OBJECT-TYPE SYNTAX INTEGER { eraseflashfile(1), eraseallflash(2), saveall(3), resetport(4), resetfilter(5), adduser(6), deleteuser(7), addlocation(8), diallocation(9), addfilter(10), deletefilter(11), addmodem(12), resetvirtport(13), addospfarea(14), resetospf(15), addprop(16), deleteprop(17), resetprop(18), resetether0(19), resetether1(20), resetall(21), resetconsole(22), version(23), traceroutes(24), ptrace(25), ifconfig(26), eraseconfig(27), erasecomos(28), reboot(29) } ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the command. Each command takes a unique value. The completion status of this command is set in the result object of the table." ::= { lucentPM4ChasCmdEntry 6 } lucentPM4ChasCmdParams OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "This object specifies the command parameters. Each parameter must be seperated by a blank space. The last parameter is terminated with a ';'." ::= { lucentPM4ChasCmdEntry 7 } lucentPM4ChasCmdResult OBJECT-TYPE SYNTAX PMDiagCmdStatus ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the command result. The result for each of the previous 10 commands will be stored in a table, which can be retrieved by the client when needed." ::= { lucentPM4ChasCmdEntry 8 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Configuration Management Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4ConfigMgmt OBJECT IDENTIFIER ::= { lucentPM4Mib 4 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- The Lucent Interfaces Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4CmInterfaces OBJECT IDENTIFIER ::= { lucentPM4ConfigMgmt 1} -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- The Lucent Serial Interfaces table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4CmSerial OBJECT IDENTIFIER ::= { lucentPM4CmInterfaces 1 } lucentPM4SerialTable OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4SerialEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of serial interface entries." ::= { lucentPM4CmSerial 1 } lucentPM4SerialEntry OBJECT-TYPE SYNTAX LucentPM4SerialEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A serial interface entry containing objects at the physical and session layer." INDEX { lucentPM4SerialBoardIndex, lucentPM4SerialIndex } ::= { lucentPM4SerialTable 1 } LucentPM4SerialEntry ::= SEQUENCE { lucentPM4SerialBoardIndex INTEGER, lucentPM4SerialUnitType PMUnitType, lucentPM4SerialIndex INTEGER, lucentPM4ModemId INTEGER, lucentPM4SerialPortNumber INTEGER, lucentPM4SerialPhysType INTEGER, lucentPM4SerialPortStatus INTEGER, lucentPM4SerialDS0State INTEGER, lucentPM4SerialUser DisplayString, lucentPM4SerialSessionId DisplayString, lucentPM4SerialTypeHardwired INTEGER, lucentPM4SerialTypeNwDialIn INTEGER, lucentPM4SerialTypeNwDialout INTEGER, lucentPM4SerialTypeLogin INTEGER, lucentPM4SerialTypeDevice INTEGER, lucentPM4SerialTypeDeviceName DisplayString, lucentPM4SerialDirection INTEGER, lucentPm4SerialStarted TimeTicks, lucentPM4SerialIdle TimeTicks, lucentPM4SerialInSpeed Gauge, lucentPM4SerialOutSpeed Gauge, lucentPM4SerialIpAddress IpAddress, lucentPM4SerialifDescr DisplayString, lucentPM4SerialInOctets Counter, lucentPM4SerialOutOctets Counter, lucentPm4SerialQOctets Counter } lucentPM4SerialBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board in the PortMaster chassis. The Max value of this variable is limited by the number of boards in the chassis. This value is limited to 255." ::= { lucentPM4SerialEntry 1 } lucentPM4SerialUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "Unit type indicates the serial port. The interface table ifIndex is a combination of board index, unit type and unit index." ::= { lucentPM4SerialEntry 2 } lucentPM4SerialIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each serial interface on a given board." ::= { lucentPM4SerialEntry 3 } lucentPM4ModemId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This object is the cross reference to the modem interface table index. The value is dynamically assigned when the call is established." ::= { lucentPM4SerialEntry 4 } lucentPM4SerialPortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A serial port to which this modem is assigned for this call." ::= { lucentPM4SerialEntry 5 } lucentPM4SerialPhysType OBJECT-TYPE SYNTAX INTEGER { other(1), -- none of the following async(2), sync(3), isdn(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of physical serial interface, distinguished according to the physical/link protocol(s) being currently used on the interface. When this object is set to asyn(2), then the service types dial-in, dial- out, login, and device are valid. When this object is set to sync(3), the serial service types dial-in, dial- out and hardwired are valid." ::= { lucentPM4SerialEntry 6 } lucentPM4SerialPortStatus OBJECT-TYPE SYNTAX INTEGER { idle(1), connecting(2), established(3), disconnecting(4), command(5), noservice(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the serial interface." ::= { lucentPM4SerialEntry 7 } lucentPM4SerialDS0State OBJECT-TYPE SYNTAX INTEGER { notavailable(1), busyout(2), havecomport(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Cross reference value for each DS0 for a given T1/E1 line and a given board in the PM4 chassis." ::= { lucentPM4SerialEntry 8 } lucentPM4SerialUser OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of the active user. Blank if not active." ::= { lucentPM4SerialEntry 9 } lucentPM4SerialSessionId OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A unique Session Identifier which matches the RADIUS session ID. Blank when not using RADIUS." ::= { lucentPM4SerialEntry 10 } lucentPM4SerialTypeHardwired OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The active type of service being provided by the serial interface." ::= { lucentPM4SerialEntry 11 } lucentPM4SerialTypeNwDialIn OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The active type of service being provided by the serial interface." ::= { lucentPM4SerialEntry 12 } lucentPM4SerialTypeNwDialout OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The active type of service being provided by the serial interface." ::= { lucentPM4SerialEntry 13 } lucentPM4SerialTypeLogin OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The active type of service being provided by the serial interface." ::= { lucentPM4SerialEntry 14 } lucentPM4SerialTypeDevice OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The active type of service being provided by the serial interface." ::= { lucentPM4SerialEntry 15 } lucentPM4SerialTypeDeviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Device name if the lucentPM4SerialTypeDevice is enabled. This is a string of characters (e.g. /dev/tty1) indicating the device name." ::= { lucentPM4SerialEntry 16 } lucentPM4SerialDirection OBJECT-TYPE SYNTAX INTEGER { in(1), out(2), inout(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The direction the active session was initiated." ::= { lucentPM4SerialEntry 17 } lucentPM4SerialStarted OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time this session has been active." ::= { lucentPM4SerialEntry 18 } lucentPM4SerialIdle OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time this session has been idle." ::= { lucentPM4SerialEntry 19 } lucentPM4SerialInSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "An estimate of the serial interface's current inbound bandwidth in bits per second." ::= { lucentPM4SerialEntry 20 } lucentPM4SerialOutSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "An estimate of the serial interface's current outbound bandwidth in bits per second." ::= { lucentPM4SerialEntry 21 } lucentPM4SerialIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The IP address associated with the serial interface. If being used as a network type port, this is the remote user's IP address. If being used as a device or login, this is the IP address of the host the user is connected to." ::= { lucentPM4SerialEntry 22 } lucentPM4SerialifDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing information about the network interface bound to the serial interface." ::= { lucentPM4SerialEntry 23 } lucentPM4SerialInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets received on the serial interface." ::= { lucentPM4SerialEntry 24 } lucentPM4SerialOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets transmitted on the serial interface." ::= { lucentPM4SerialEntry 25 } lucentPM4SerialQOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of octets queued on the serial interface." ::= { lucentPM4SerialEntry 26 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- The Lucent T1/E1 Interface table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4CmT1E1 OBJECT IDENTIFIER ::= { lucentPM4CmInterfaces 2 } lucentPM4T1E1Table OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4T1E1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of T1/E1 interface entries." ::= { lucentPM4CmT1E1 1 } lucentPM4T1E1Entry OBJECT-TYPE SYNTAX LucentPM4T1E1Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "A T1/E1 entry containing objects at the physical layer." INDEX { lucentPM4T1E1BoardIndex, lucentPM4T1E1Index } ::= { lucentPM4T1E1Table 1 } LucentPM4T1E1Entry ::= SEQUENCE { lucentPM4T1E1BoardIndex INTEGER, lucentPM4T1E1UnitType PMUnitType, lucentPM4T1E1Index INTEGER, lucentPM4T1E1SerialIndex INTEGER, lucentPM4T1E1SerialCount INTEGER, lucentPM4T1E1PhysType INTEGER, lucentPM4T1E1Status INTEGER, lucentPM4T1E1Function INTEGER, lucentPM4T1E1Framing INTEGER, lucentPM4T1E1Encoding INTEGER, lucentPM4T1E1PCM INTEGER, lucentPM4T1E1SuperSignal INTEGER, lucentPM4T1E1StartMode INTEGER, lucentPM4T1E1ChangeTime TimeTicks, lucentPM4T1E1RecvLevel Gauge, lucentPM4T1E1BlueAlarms Counter, lucentPM4T1E1YellowAlarms Counter, lucentPM4T1E1CarrierLoss Counter, lucentPM4T1E1SyncLoss Counter, lucentPM4T1E1BipolarErrors Counter, lucentPM4T1E1CRCErrors Counter, lucentPM4T1E1SyncErrors Counter } lucentPM4T1E1BoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board in the PM4 chassis." ::= { lucentPM4T1E1Entry 1 } lucentPM4T1E1UnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "This object specifies the type of the unit as the T1/E1 line. This value is a part of the interface table ifIndex." ::= { lucentPM4T1E1Entry 2 } lucentPM4T1E1Index OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each T1/E1 interface." ::= { lucentPM4T1E1Entry 3 } lucentPM4T1E1SerialIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of the instance for the serial port. This object provides a cross reference from the T1/E1 interface to the serial port to which it is mapped." ::= { lucentPM4T1E1Entry 4 } lucentPM4T1E1SerialCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of serial ports assigned to this interface. If this is a Channelized T1/E1, then the count is 24/32. If this is a fractional T1/E1, then the count can be any number between 1 and a number less than 24/32." ::= { lucentPM4T1E1Entry 5 } lucentPM4T1E1PhysType OBJECT-TYPE SYNTAX INTEGER { t1(1), e1(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of interface (T1 or E1)." ::= { lucentPM4T1E1Entry 6 } lucentPM4T1E1Status OBJECT-TYPE SYNTAX PMEquipPRIStatus ACCESS read-only STATUS mandatory DESCRIPTION "The current operational status of the interface." ::= { lucentPM4T1E1Entry 7 } lucentPM4T1E1Function OBJECT-TYPE SYNTAX INTEGER { isdn(1), channelized(2), clear(3), fractional(4), isdnfrac(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The configured function of the interface." ::= { lucentPM4T1E1Entry 8 } lucentPM4T1E1Framing OBJECT-TYPE SYNTAX INTEGER { esf(1), d4(2), crc4(3), fas(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The configured line framing." ::= { lucentPM4T1E1Entry 9 } lucentPM4T1E1Encoding OBJECT-TYPE SYNTAX INTEGER { ami(1), b8zs(2), hdb3(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The configured line signal encoding." ::= { lucentPM4T1E1Entry 10 } lucentPM4T1E1PCM OBJECT-TYPE SYNTAX INTEGER { ulaw(1), alaw(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The configured voice modulation." ::= { lucentPM4T1E1Entry 11 } lucentPM4T1E1SuperSignal OBJECT-TYPE SYNTAX INTEGER { em(1), groundstart(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The configured supervisory signalling mode for this interface." ::= { lucentPM4T1E1Entry 12 } lucentPM4T1E1StartMode OBJECT-TYPE SYNTAX INTEGER { wink(1), immediate(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The configured start mode for this interface." ::= { lucentPM4T1E1Entry 13 } lucentPM4T1E1ChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The amount of time since the last status change." ::= { lucentPM4T1E1Entry 14 } lucentPM4T1E1RecvLevel OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "An estimate of the serial interface's current recieve signal level in DB." ::= { lucentPM4T1E1Entry 15 } lucentPM4T1E1BlueAlarms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Blue Alarms on the interface." ::= { lucentPM4T1E1Entry 16 } lucentPM4T1E1YellowAlarms OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of Yellow Alarms on the interface." ::= { lucentPM4T1E1Entry 17 } lucentPM4T1E1CarrierLoss OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of times the interface has lost carrier." ::= { lucentPM4T1E1Entry 18 } lucentPM4T1E1SyncLoss OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of times the interface has lost frame synchronization." ::= { lucentPM4T1E1Entry 19 } lucentPM4T1E1BipolarErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of bipolar violations detected on the interface." ::= { lucentPM4T1E1Entry 20 } lucentPM4T1E1CRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frame level CRC errors detected on the interface." ::= { lucentPM4T1E1Entry 21 } lucentPM4T1E1SyncErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of frame synchronization errors detected on the interface." ::= { lucentPM4T1E1Entry 22 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- The Lucent Modem Interface Configuration table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4CmModem OBJECT IDENTIFIER ::= { lucentPM4CmInterfaces 3 } lucentPM4ModemTable OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4ModemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of modem entries." ::= { lucentPM4CmModem 1 } lucentPM4ModemEntry OBJECT-TYPE SYNTAX LucentPM4ModemEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A modem entry containing objects at the session layer." INDEX { lucentPM4ModemBoardIndex, lucentPM4ModemUnitType, lucentPM4ModemIndex } ::= { lucentPM4ModemTable 1 } LucentPM4ModemEntry ::= SEQUENCE { lucentPM4ModemBoardIndex INTEGER, lucentPM4ModemUnitType PMUnitType, lucentPM4ModemIndex INTEGER, lucentPM4ModemPortName DisplayString, lucentPM4ModemStatus INTEGER, lucentPM4ModemProtocol INTEGER, lucentPM4ModemCompression INTEGER, lucentPM4ModemInSpeed Gauge, lucentPM4ModemOutSpeed Gauge, lucentPM4ModemInByteCount Counter, lucentPM4ModemOutByteCount Counter, lucentPM4ModemRetrains Counter, lucentPM4ModemRenegotiates Counter, lucentPM4ModemCalls Counter, lucentPM4ModemDetects Counter, lucentPM4ModemConnects Counter } lucentPM4ModemBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each modem interface." ::= { lucentPM4ModemEntry 1 } lucentPM4ModemUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "Unit type specifies the type of device or interface." ::= { lucentPM4ModemEntry 2 } lucentPM4ModemIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each modem interface. The value of this object can be 1 - 96 for a Quad T1, 1 - 94 for a Tri E1 card." ::= { lucentPM4ModemEntry 3 } lucentPM4ModemPortName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing the name of the serial interface (ie. S0, S1, etc)." ::= { lucentPM4ModemEntry 4 } lucentPM4ModemStatus OBJECT-TYPE SYNTAX INTEGER { none(1), bound(2), connecting(3), active(4), test(5), down(6), ready(7), halt(8), admin(9) } ACCESS read-only STATUS mandatory DESCRIPTION "A current state of the modem." ::= { lucentPM4ModemEntry 5 } lucentPM4ModemProtocol OBJECT-TYPE SYNTAX INTEGER { none(1), lapm(2), mnp(3), bufferd(4), direct(5), cellular(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The error correcting protocol being used in the modem." ::= { lucentPM4ModemEntry 6 } lucentPM4ModemCompression OBJECT-TYPE SYNTAX INTEGER { none(1), v42bis(2), mnp5(3), stac(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The compression being used in the modem interface." ::= { lucentPM4ModemEntry 7 } lucentPM4ModemInSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "An estimate of the modem interface's current inbound bandwidth in bits per second." ::= { lucentPM4ModemEntry 8 } lucentPM4ModemOutSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "An estimate of the modem interface's current outbound bandwidth in bits per second." ::= { lucentPM4ModemEntry 9 } lucentPM4ModemInByteCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of bytes received on the serial interface." ::= { lucentPM4ModemEntry 10 } lucentPM4ModemOutByteCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of bytes transmitted on the serial interface." ::= { lucentPM4ModemEntry 11 } lucentPM4ModemRetrains OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of retrains attempted by the modem." ::= { lucentPM4ModemEntry 12 } lucentPM4ModemRenegotiates OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of renegotiates attempted by the modem." ::= { lucentPM4ModemEntry 13 } lucentPM4ModemCalls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times a call received by the modem." ::= { lucentPM4ModemEntry 14 } lucentPM4ModemDetects OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of analog calls received by the modem." ::= { lucentPM4ModemEntry 15 } lucentPM4ModemConnects OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of successful calls received by the modem." ::= { lucentPM4ModemEntry 16 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- The Lucent Ethernet Interface table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4CmEther OBJECT IDENTIFIER ::= { lucentPM4CmInterfaces 4 } lucentPM4EtherTable OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4EtherEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of ethernet interface entries. This object is not accessible" ::= { lucentPM4CmEther 1 } lucentPM4EtherEntry OBJECT-TYPE SYNTAX LucentPM4EtherEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Ethernet interface entry containing objects at the Session/Physical layers." INDEX { lucentPM4EtherBoardIndex, lucentPM4EtherIfType, lucentPM4EtherIndex } ::= { lucentPM4EtherTable 1 } LucentPM4EtherEntry ::= SEQUENCE { lucentPM4EtherBoardIndex INTEGER, lucentPM4EtherIfType PMUnitType, lucentPM4EtherIndex INTEGER, lucentPM4EtherIfIndex INTEGER, lucentPM4EtherPortName DisplayString, lucentPM4EtherMacAddr PhysAddress, lucentPM4EtherIPAddr IpAddress, lucentPM4EtherIPGateway IpAddress, lucentPM4EtherPriNameServer IpAddress, lucentPM4EtherAltNameServer IpAddress, lucentPM4EtherSubnetMask IpAddress, lucentPM4EtherInFilter DisplayString, lucentPM4EtherOutFilter DisplayString, lucentPM4EtherOptRip INTEGER, lucentPM4EtherOptSlip INTEGER, lucentPM4EtherOptEtherDown INTEGER, lucentPM4EtherOptBcastHigh INTEGER, lucentPM4EtherOptSnmp INTEGER, lucentPM4EtherOptNoListen INTEGER, lucentPM4EtherOptDefaultRip INTEGER, lucentPM4EtherOptDefaultListen INTEGER, lucentPM4EtherOptIPFilter INTEGER, lucentPM4EtherOptDns INTEGER, lucentPM4EtherOptPmeMsg INTEGER, lucentPM4EtherOptNoClip INTEGER, lucentPM4EtherOptEtherIpx INTEGER, lucentPM4EtherOptNetBIOS INTEGER, lucentPM4EtherOptAccounting INTEGER, lucentPM4EtherOptNoPAP INTEGER } lucentPM4EtherBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each ethernet board. The manager card has two ethernet interfaces at present. The ethernet interface in slot 4 has a board ID 10 and if there is a manager card in slot 5, the board ID for the interface would be 11." ::= { lucentPM4EtherEntry 1 } lucentPM4EtherIfType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "The interface type which together with the board ID and the interface number will uniquely identify the interface." ::= { lucentPM4EtherEntry 2 } lucentPM4EtherIndex OBJECT-TYPE SYNTAX INTEGER { ether0(1), ether1(2), other(3) } ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each ethernet interface. The manager card has two ethernet interfaces at present. ether0(1) represents 10 Base-T interface and ether1(2) specifies the 10/100 Base-T auto-sensing ethernet interface." ::= { lucentPM4EtherEntry 3 } lucentPM4EtherIfIndex OBJECT-TYPE SYNTAX INTEGER { ether0(67436545), ether1(168099841) } ACCESS read-only STATUS mandatory DESCRIPTION "IfIndex cross reference value for the ethernet interfaces. The manager card has two ethernet interfaces at present. ether0(67436545) represents 10 Base-T interface which corresponds to board 4 and interface 1. The enumerated value ether1(168099841) specifies the 10/100 Base-T auto-sensing ethernet interface which corresponds to board 4 and interface 2. We can add the standby manager card ethernet interfaces when they are available." ::= { lucentPM4EtherEntry 4 } lucentPM4EtherPortName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) ACCESS read-write STATUS mandatory DESCRIPTION "A printable ASCII string specifying the name of the ethernet port." ::= { lucentPM4EtherEntry 5 } lucentPM4EtherMacAddress OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "Physical address of the interface." ::= { lucentPM4EtherEntry 6 } lucentPM4EtherIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the interface." ::= { lucentPM4EtherEntry 7 } lucentPM4EtherIpGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the gateway machine." ::= { lucentPM4EtherEntry 8 } lucentPM4EtherPriNameServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the primary name server." ::= { lucentPM4EtherEntry 9 } lucentPM4EtherAltNameServer OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the alternate name server." ::= { lucentPM4EtherEntry 10 } lucentPM4EtherSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the interface. Used to partition the network into different branches." ::= { lucentPM4EtherEntry 11 } lucentPM4EtherInFilter OBJECT-TYPE SYNTAX DisplayString (SIZE(1..16)) ACCESS read-write STATUS mandatory DESCRIPTION "IP Input packet filter. Used to control the type of IP packets reaching the interface." ::= { lucentPM4EtherEntry 12 } lucentPM4EtherOutFilter OBJECT-TYPE SYNTAX DisplayString (SIZE(1..16)) ACCESS read-write STATUS mandatory DESCRIPTION "IP output packet filter. Used to control the type of packets sent out of the interface." ::= { lucentPM4EtherEntry 13 } lucentPM4EtherOptRip OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The RIP protocol enable/disable option." ::= { lucentPM4EtherEntry 14 } lucentPM4EtherOptSlip OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The SLIP protocol enable/disable option." ::= { lucentPM4EtherEntry 15 } lucentPM4EtherOptEtherDown OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Ethernet interface down enable/disable option." ::= { lucentPM4EtherEntry 16 } lucentPM4EtherOptBcastHigh OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Use high one(s) broadcast address enable/disable option." ::= { lucentPM4EtherEntry 17 } lucentPM4EtherOptSnmp OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Default SNMP protocol enable/disable option." ::= { lucentPM4EtherEntry 18 } lucentPM4EtherOptNoListen OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Do not listen to RIP on the ether interface." ::= { lucentPM4EtherEntry 19 } lucentPM4EtherOptDefaultRip OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Default RIP protocol enable/disable option." ::= { lucentPM4EtherEntry 20 } lucentPM4EtherOptDefaultListen OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Default listen enable/disable option." ::= { lucentPM4EtherEntry 21 } lucentPM4EtherOptIPFilter OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "IP filter enable/disable option." ::= { lucentPM4EtherEntry 22 } lucentPM4EtherOptDns OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "DNS enable/disable option." ::= { lucentPM4EtherEntry 23 } lucentPM4EtherOptPmeMsg OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "PME Msg. enable/disable option. Whatever that means." ::= { lucentPM4EtherEntry 24 } lucentPM4EtherOptNoClip OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "No Clip enable/disable option. Whatever that means." ::= { lucentPM4EtherEntry 25 } lucentPM4EtherOptEtherIpx OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Ether IPX enable/disable option." ::= { lucentPM4EtherEntry 26 } lucentPM4EtherOptNetBIOS OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Net BIOS enable/disable option." ::= { lucentPM4EtherEntry 27 } lucentPM4EtherOptAccounting OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Accounting enable/disable option." ::= { lucentPM4EtherEntry 28 } lucentPM4EtherOptNoPAP OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "PAP enable/disable option." ::= { lucentPM4EtherEntry 29 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Fault Management Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4FaultMgmt OBJECT IDENTIFIER ::= { lucentPM4Mib 5 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Fault Isolation Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4FaultMgmtIsolation OBJECT IDENTIFIER ::= { lucentPM4FaultMgmt 1 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Chassis Global Fault management table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4FaultMgmtChasTrap OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4FMChasTrapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Chassis Trap table which indicates one of several Traps. The chassis trap table stores the previous history of the traps which can be retrieved by the management stations at a later time. This object is not-accessible and present for MIB clarity." ::= { lucentPM4FaultMgmtIsolation 1 } lucentPM4FMChasTrapEntry OBJECT-TYPE SYNTAX LucentPM4FMChasTrapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry in the chassis Trap table. Each trap is uniquely identified by an index. This object is not accessible and present for MIB clarity." INDEX { lucentPM4FMChasTrapIndex } ::= { lucentPM4FaultMgmtChasTrap 1 } LucentPM4FMChasTrapEntry ::= SEQUENCE { lucentPM4FMChasTrapIndex INTEGER, lucentPM4FMChasBoardID INTEGER, lucentPM4FMChasTrapUnitType PMUnitType, lucentPM4FMChasTrapUnitIndex INTEGER, lucentPM4FMChasTrapStatus INTEGER, lucentPM4FMChasTrapSeverity INTEGER, lucentPM4FMChasTrapTimeStamp TimeTicks, lucentPM4FMChasTrapState INTEGER } lucentPM4FMChasTrapIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Index into the Trap table on the agent. This table stores the previous 500 traps which can be retrieved at any given time." ::= { lucentPM4FMChasTrapEntry 1 } lucentPM4FMChasTrapBoardID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Board ID is the board number for which this trap is stored. If the trap is for an auxillary device such as a power supply or fan, this value is set to zero." ::= { lucentPM4FMChasTrapEntry 2 } lucentPM4FMChasTrapUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "Uniquely specifies the unit type for this trap. The unit can be a board or any other device in the chassis such as a fan or a power supply." ::= { lucentPM4FMChasTrapEntry 3 } lucentPM4FMChasTrapUnitIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Uniquely specifies the unit index. The unit index is same as the ifIndex for T1/E1 interfaces, or the modemIndex for the modems or fan or power supply index for fan or power supplies." ::= { lucentPM4FMChasTrapEntry 4 } lucentPM4FMChasTrapStatus OBJECT-TYPE SYNTAX INTEGER { other(1), online(2), offline(3), maintenance(4), fault(5), notinstalled(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Trap status specifies the associated object in the Trap is online(2), offline(3), maintenance(4) or fault(5)." ::= { lucentPM4FMChasTrapEntry 5 } lucentPM4FMChasTrapSeverity OBJECT-TYPE SYNTAX PMAlarmType ACCESS read-only STATUS mandatory DESCRIPTION "Trap severity specifies the severity of the Trap for the associated object." ::= { lucentPM4FMChasTrapEntry 6 } lucentPM4FMChasTrapTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "This object stores the timestamp of this trap." ::= { lucentPM4FMChasTrapEntry 7 } lucentPM4FMChasTrapState OBJECT-TYPE SYNTAX INTEGER { trapsent(1), ackdue(2), acked(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object stores the Trap state of this trap." ::= { lucentPM4FMChasTrapEntry 8 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Fault management objects -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4FMBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Board index uniquely specifies the board in the chassis. This object is set to zero for power supplies, fans and other auxillary devices. This object is not accessible through Get, Get-Next or Set PDUs. It is sent out as part of the Trap." ::= { lucentPM4FaultMgmtIsolation 2 } lucentPM4FMUnitIndex OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "Unit index uniquely specifies the T1/E1 line, or modem or any device (logical/physical) in the chassis. This object is not accessible through Get, Get-Next or Set PDUs. It is sent out as part of the Trap." ::= { lucentPM4FaultMgmtIsolation 3 } lucentPM4FMUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS not-accessible STATUS mandatory DESCRIPTION "Unit type specifies the T1/E1 line, or modem or any device in the chassis. This object is not accessible through Get, Get-Next or Set PDUs. It is sent out as part of the Trap." ::= { lucentPM4FaultMgmtIsolation 4 } lucentPM4FMUnitTrapStatus OBJECT-TYPE SYNTAX INTEGER { other(1), offline(2), online(3), failed(4), restored(5), pwrwarn(6), tempwarn(7), temphot(8), dtrloss(9), carrierloss(10), renegotiation(11), los(12), -- Loss of Signal ais(13), -- Alarm Indication Signal redalarm(14), -- Loss of Framing yellowalarm(15), -- Remote Alarm Indication (indicating remote red alarm) cv(16), -- Code Violation crc(17), -- Cyclic Redundancy Check bpv(18), -- Bipolar Violations fer(19), -- Framing Errors pll(20), -- Phase Locked Loop es(21), -- Errored Seconds ses(22), -- Severely Errored Seconds sefs(23), -- Severely Errored Framing Seconds uas(24), -- Unavailable Seconds dm(25), -- Degraded Minutes les(26), -- Line Errored Seconds css(27), -- Controlled Slip Seconds bes(28) -- Bursty Errored Seconds } ACCESS not-accessible STATUS mandatory DESCRIPTION "Trap status specifies the associated object in the Trap. This object is not accessible other than when produced as the result of a trap." ::= { lucentPM4FaultMgmtIsolation 5 } lucentPM4FMUnitTrapSeverity OBJECT-TYPE SYNTAX PMAlarmType ACCESS not-accessible STATUS mandatory DESCRIPTION "Trap severity specifies the severity of the Trap for the associated object. This object is not accessible except when produced as the result of a trap." ::= { lucentPM4FaultMgmtIsolation 6 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Alarm Configuration Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4FMTrapConfig OBJECT IDENTIFIER ::= { lucentPM4FaultMgmt 2 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Equipment Traps configuration table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4FMEqpTrapCfg OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4FMEqpTrapCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Equipment Trap configuration table configure Traps. The objects in this table are used to enable or disable traps on a per board/interface/device basis. This object is not-accessible and present for MIB clarity." ::= { lucentPM4FMTrapConfig 1 } lucentPM4FMEqpTrapCfgEntry OBJECT-TYPE SYNTAX LucentPM4FMEqpTrapCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry in the equipment Trap config table. Each trap is uniquely identified by the board ID, Unit type and unit index. For auxillary devices such as power supplies and fans, the board index will be zero, the unit index identifies the units and the unit type specifies if the unit is a fan, power supplies etc. This object is not accessible and present for MIB clarity." INDEX { lucentPM4FMEqpBoardIndex, lucentPM4FMEqpUnitType, lucentPM4FMEqpUnitIndex } ::= { lucentPM4FMEqpTrapCfg 1 } LucentPM4FMEqpTrapCfgEntry ::= SEQUENCE { lucentPM4FMEqpBoardIndex INTEGER, lucentPM4FMEqpUnitType PMUnitType, lucentPM4FMEqpunitIndex INTEGER, lucentPM4FMEqpTrapId INTEGER, lucentPM4FMEqpTrapCtl INTEGER, lucentPM4FMEqpTrapRepTimer INTEGER } lucentPM4FMEqpBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Board ID for which the Trap configuration need to apply. The board ID is zero if this trap configuration is for an auxillary device such as fans or power supplies." ::= { lucentPM4FMEqpTrapCfgEntry 1 } lucentPM4FMEqpUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "Unit type alongwith the board index and unit index specifies uniquely the device/interface which is being configured." ::= { lucentPM4FMEqpTrapCfgEntry 2 } lucentPM4FMEqpUnitIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unit index refers to the interface or sub-device such as a modem, serial port etc. For devices such as power supplies and fans this object is zero." ::= { lucentPM4FMEqpTrapCfgEntry 3 } lucentPM4FMEqpTrapId OBJECT-TYPE SYNTAX INTEGER { boardoffline(1), boardonline(2), pwrsupfail(3), pwrsuprestored(4), fanfail(5), fanrestored(6), boardtempwarn(7), boardtempnormal(8), boardtoohot(9), modemfail(10), linedown(11), lineup(12), linethresh(13), boardpwrshutdown(14), radiusauthfail(15) } ACCESS read-write STATUS mandatory DESCRIPTION "Trap ID indicating the trap for which the configuration must apply." ::= { lucentPM4FMEqpTrapCfgEntry 4 } lucentPM4FMEqpTrapCtl OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Trap control which configures the trap off(1) or on(2). When the trap is configured as off(1), the trap is not sent out to the management station. When configures as on(2), the trap is sent to all the management stations configured to receive the trap." ::= { lucentPM4FMEqpTrapCfgEntry 5 } lucentPM4FMEqpRepTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the trap is to be repeated, this object specifies the time in seconds. When this object value is set to 0, it indicates the trap is non-repeat trap." ::= { lucentPM4FMEqpTrapCfgEntry 6 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent T1/E1 Threshold Traps configuration table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4FMT1E1ThreshTrapCfg OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4FMThreshT1E1TrapCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "T1/E1 Threshold Trap configuration table to configure the thresholds for various T1/E1 traps. This object is not-accessible and present for MIB clarity." ::= { lucentPM4FMTrapConfig 2 } lucentPM4FMT1E1ThreshTrapCfgEntry OBJECT-TYPE SYNTAX LucentPM4FMThreshT1E1TrapCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry in the T1/E1 threshold trap config table. Each trap is uniquely identified by the board index, unit type and unit index which is the T1/E1 interface number. This object is not accessible and present for MIB clarity." INDEX { lucentPM4FMThreshBoardIndex, lucentPM4FMThreshUnitType, lucentPM4FMThreshUnitIndex } ::= { lucentPM4FMT1E1ThreshTrapCfg 1 } LucentPM4FMThreshT1E1TrapCfgEntry ::= SEQUENCE { lucentPM4FMT1E1ThreshBoardIndex INTEGER, lucentPM4FMT1E1ThreshUnitType INTEGER, lucentPM4FMT1E1ThreshUnitIndex INTEGER, lucentPM4FMT1E1ThreshESs Gauge, lucentPM4FMT1E1ThreshSESs Gauge, lucentPM4FMT1E1ThreshSEFSs Gauge, lucentPM4FMT1E1ThreshUASs Gauge, lucentPM4FMT1E1ThreshCSSs Gauge, lucentPM4FMT1E1ThreshPCVs Gauge, lucentPM4FMT1E1ThreshLESs Gauge, lucentPM4FMT1E1ThreshBESs Gauge, lucentPM4FMT1E1ThreshDMs Gauge, lucentPM4FMT1E1ThreshTrapRepTimer INTEGER, lucentPM4FMT1E1ThreshTrapAck INTEGER } lucentPM4FMT1E1ThreshBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Board ID for which the Trap threshold configuration must apply. It includes boards 1 - 10 and other devices such as power supplies and fans etc." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 1 } lucentPM4FMT1E1ThreshUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "Unit type for which the Trap threshold configuration must be applied." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 2 } lucentPM4FMT1E1ThreshESs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for errored seconds on the interface. A trap is issued when this set limit is exceeded. When this threshold exceeds, the performance of the interface will degrade. A trap is generated to notify the adminstrator to take appropriate action." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 3 } lucentPM4FMT1E1ThreshSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for severely errored seconds on the interface. A trap is issued when this limit is exceeded. A severely errored seconds is a second with 320 or more path code violation error events or one or more out of frame defects or detected AIS defect." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 4 } lucentPM4FMT1E1ThreshSEFSs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for severely errored framing seconds. A trap is issued when this threshold is exceeded. A severely errored framing second is a second with one or more frame defects or detected AIS defect." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 5 } lucentPM4FMT1E1ThreshUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for unavailable seconds. A trap is issued when this set threshold is exceeded. Unavailable seconds are calculated by counting the number of seconds that the interface is unavailable from the onset of 10 SESs. Once unavailable, the interface becomes available at the onset of 10 contiguous no SESs." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 6 } lucentPM4FMT1E1ThreshCSSs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for controlled slip seconds on the interface. A trap is issued when this set threshold is exceeded. A controlled slip second is a one-second interval containing one or more controlled slips." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 7 } lucentPM4FMT1E1ThreshPCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for path code violations on the interface. A trap is issued when this set threshold is exceeded. PCV is a frame syncronization bit error in the D4 and E1-noCRC format interfaces or a CRC error in the ESF (extended super frame) and E1-CRC interface formats." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 8 } lucentPM4FMT1E1ThreshLESs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for line errored seconds on the interface. A trap is sent to the manager when this set threshold is exceeded. A line errored second, according to T1M1.3 is a second in which one or more line code violations were detected." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 9 } lucentPM4FMT1E1ThreshBESs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for bursty errored seconds on the interface. A trap is sent to the manager when this set threshold is exceeded. A bursty errored second is a second with fewer than 320 and more than 1 path code violations." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 10 } lucentPM4FMT1E1ThreshDMs OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for degraded minutes on the interface. A trap is sent to the manager when this set threshold is exceeded. Degraded minutes are determined by collecting all of the available seconds, after removing any severely errored seconds. The resulting seconds is grouped into 60 second intervals and if the cumulative errors during the seconds present in the group exceeds 1E-6." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 11 } lucentPM4FMT1E1ThreshRepTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the trap is to be repeated, this object specifies the time in seconds. When this object value is set to 0, it indicates the trap is non-repeat trap." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 12 } lucentPM4FMT1E1ThreshTrapAck OBJECT-TYPE SYNTAX INTEGER { other(1), noack(2), ack(3) } ACCESS read-write STATUS mandatory DESCRIPTION "If set to ack(3), clears the trap condition. If the value is set to noack(2), leaves the trap condition unchanged." ::= { lucentPM4FMT1E1ThreshTrapCfgEntry 13 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Environment Traps configuration table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4FMEnvTrapCfg OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4FMEnvTrapCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Environment Trap configuration table. This table enables configuration of voltage, power levels and temperature ranges for different units in the chassis. This object is not-accessible and present for MIB clarity." ::= { lucentPM4FMTrapConfig 3 } lucentPM4FMEnvTrapCfgEntry OBJECT-TYPE SYNTAX LucentPM4FMEnvTrapCfgEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry in the environment trap config table. Each trap is uniquely identified by the board index, unit type and unit index. This object is not accessible and present for MIB clarity." INDEX { lucentPM4FMEnvBoardID, lucentPM4FMEnvUnitType, lucentPM4FMEnvUnitIndex } ::= { lucentPM4FMEnvTrapCfg 1 } LucentPM4FMEnvTrapCfgEntry ::= SEQUENCE { lucentPM4FMEnvBoardID INTEGER, lucentPM4FMEnvUnitType PMUnitType, lucentPM4FMEnvUnitIndex INTEGER, lucentPM4FMEnvOptUnitTemp INTEGER, lucentPM4FMEnvUnitTempRange INTEGER, lucentPM4FMEnvOptUnitPwrLvl INTEGER, lucentPM4FMEnvUnitPwrRange INTEGER, lucentPM4FMEnvTrapCtl INTEGER, lucentPM4FMEnvTrapRepTimer INTEGER } lucentPM4FMEnvBoardID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Board ID specifies the board identifier for this trap. If the trap configuration is for an auxillary device such as a power supply or fan, this object will be set to zero. The unit type and the unit index will uniquely identify the auxillary devices." ::= { lucentPM4FMEnvTrapCfgEntry 1 } lucentPM4FMEnvUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "Unit for which the Trap configuration must to apply." ::= { lucentPM4FMEnvTrapCfgEntry 2 } lucentPM4FMEnvUnitIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Unit index specifies the interface or sub-unit for this trap (modem or T1/E1 interface etc.). The unit type and the unit index will uniquely identify the auxillary devices." ::= { lucentPM4FMEnvTrapCfgEntry 3 } lucentPM4FMEnvOptUnitTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The optimum temperature for this unit. A trap is generated when the temperature deviates from the specified range. The temperature is specified as an integer in degrees farenheit." ::= { lucentPM4FMEnvTrapCfgEntry 4 } lucentPM4FMEnvUnitTempRange OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The temperature range above which a trap is generated. The temperature must be specified as an integer in degree Farenhiet (for example +/- 5 degree Far.)." ::= { lucentPM4FMEnvTrapCfgEntry 5 } lucentPM4FMEnvOptUnitPwrLvl OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The optimal power level that is appropriate for this unit. A trap is generated when the power level fluctuates outside the limits set." ::= { lucentPM4FMEnvTrapCfgEntry 6 } lucentPM4FMEnvUnitPwrRange OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The power range specified in volts. A trap is generated when the power level fluctuates outside the Opt Pwr +/- Range set." ::= { lucentPM4FMEnvTrapCfgEntry 7 } lucentPM4FMEnvTrapCtl OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The trap control used to turn the environment traps on or off for the specified unit(s)." ::= { lucentPM4FMEnvTrapCfgEntry 8 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Performance Management Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4PerfMgmt OBJECT IDENTIFIER ::= { lucentPM4Mib 6 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent T1/E1 Performance Management Current Interval Table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4T1E1PerfMgmt OBJECT IDENTIFIER ::= { lucentPM4PerfMgmt 1 } lucentPM4T1E1PMCur OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4T1E1PMCurEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Performance management table representing the performance statistics of T1/E1 interfaces in the box. This table represents the current 15 mins statistics. This object is not accessible and present for clarity purpose. This table is part of RFC 1406." ::= { lucentPM4T1E1PerfMgmt 1 } lucentPM4T1E1PMCurEntry OBJECT-TYPE SYNTAX LucentPM4T1E1PMCurEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Performance management table entries for all the T1/E1 interfaces in the box. This table represents the current 15 mins statistics. This object is not accessible and present for clarity purpose." INDEX { lucentPM4T1E1PMBoardID, lucentPM4T1E1PMUnitType, lucentPM4T1E1PMLineNum } ::= { lucentPM4T1E1PMCur 1 } LucentPM4T1E1PMCurEntry ::= SEQUENCE { lucentPM4T1E1PMCurBoardID INTEGER, lucentPM4T1E1PMCurUnitType PMUnitType, lucentPM4T1E1PMCurLineNum INTEGER, lucentPM4T1E1PMCurIfIndex INTEGER, lucentPM4T1E1PMCurESs Gauge, lucentPM4T1E1PMCurSESs Gauge, lucentPM4T1E1PMCurSEFs Gauge, lucentPM4T1E1PMCurUASs Gauge, lucentPM4T1E1PMCurCSSs Gauge, lucentPM4T1E1PMCurPCVs Gauge, lucentPM4T1E1PMCurLESs Gauge, lucentPM4T1E1PMCurBESs Gauge, lucentPM4T1E1PMCurDMs Gauge, lucentPM4T1E1PMCurLCVs Gauge } lucentPM4T1E1PMCurBoard OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Board number of the interface. The global interface number is computed by using the Most Significant byte of the ifIndex and the Least Significant 2 bytes represents the interface index. Byte 3 will represent the unit type which would be a T1 or E1." ::= { lucentPM4T1E1PMCurEntry 1 } lucentPM4T1E1PMCurUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "Unit type indicates the type of interface as T1/E1 or T3/E3 in future. This is part of the interface table ifIndex which is constructed with boardID, unit type and unit index." ::= { lucentPM4T1E1PMCurEntry 2 } lucentPM4T1E1PMCurLineNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Line number uniquely identifies the T1/E1 interface on a given board." ::= { lucentPM4T1E1PMCurEntry 3 } lucentPM4T1E1PMCurIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interface table ifIndex cross reference. The global interface number is computed by using the Most Significant byte as the board ID and the Least Significant 2 bytes represents the interface index. The third byte represents the unit type which will be a T1 or E1. Thus board 0 interface 3 is represented as 0x00050003. The global interface number corresponds to the IfIndex in MIB II." ::= { lucentPM4T1E1PMCurEntry 4 } lucentPM4T1E1PMCurESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of errored seconds, encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 5 } lucentPM4T1E1PMCurSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Seconds encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 6 } lucentPM4T1E1PMCurSEFSs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Framing Seconds encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 7 } lucentPM4T1E1PMCurUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Unavailable Seconds encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 8 } lucentPM4T1E1PMCurCSSs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Controlled Slip Seconds encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 9 } lucentPM4T1E1PMCurPCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Path Coding Violations encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 10 } lucentPM4T1E1PMCurLESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Line Errored Seconds encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 11 } lucentPM4T1E1PMCurBESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bursty Errored Seconds encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 12 } lucentPM4T1E1PMCurDMs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Degraded Minutes encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 13 } lucentPM4T1E1PMCurLCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Line Code Violations encountered by the line in the current 15 mins interval." ::= { lucentPM4T1E1PMCurEntry 14 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent T1/E1 Performance Management Previous Intervals Table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4T1E1PMInt OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4T1E1PMIntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Performance management table representing the performance statistics of T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose. This table is part of RFC 1406." ::= { lucentPM4PerfMgmt 2 } lucentPM4T1E1PMIntEntry OBJECT-TYPE SYNTAX LucentPM4T1E1PMIntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Performance management table entries for all the T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose." INDEX { lucentPM4T1E1PMIntBoard, lucentPM4T1E1PMIntUnitType, lucentPM4T1E1PMIntLineNum, lucentPM4T1E1PMIntInterval } ::= { lucentPM4T1E1PMInt 1 } LucentPM4T1E1PMIntEntry ::= SEQUENCE { lucentPM4T1E1PMIntBoard INTEGER, lucentPM4T1E1PMIntUnitType PMUnitType, lucentPM4T1E1PMIntLineNum INTEGER, lucentPM4T1E1PMIntIfIndex INTEGER, lucentPM4T1E1PMIntInterval INTEGER, lucentPM4T1E1PMIntESs Gauge, lucentPM4T1E1PMIntSESs Gauge, lucentPM4T1E1PMIntSEFs Gauge, lucentPM4T1E1PMIntUASs Gauge, lucentPM4T1E1PMIntCSSs Gauge, lucentPM4T1E1PMIntPCVs Gauge, lucentPM4T1E1PMIntLESs Gauge, lucentPM4T1E1PMIntBESs Gauge, lucentPM4T1E1PMIntDMs Gauge, lucentPM4T1E1PMIntLCVs Gauge } lucentPM4T1E1PMIntBoard OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Board number of the interface. The global interface number is computed by using the Most Significant nibble of the ifIndex and the Least Significant nibble represents the interface index. Thus board 0 interface 3 is represented as 0x03 or 03 decimal and board 10 interface 3 is represented as 0xa3 or 163 decimal. In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface number corresponds to the IfIndex of MIB II." ::= { lucentPM4T1E1PMIntEntry 1 } lucentPM4T1E1PMIntUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "Unit type indicates the type of physical or logical device. The unit type for this table is either T1 or E1." ::= { lucentPM4T1E1PMIntEntry 2 } lucentPM4T1E1PMIntLineNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Line number uniquely identifies the T1/E1 interface for this board." ::= { lucentPM4T1E1PMIntEntry 3 } lucentPM4T1E1PMIntInterval OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "Interval number for a given board. The 24 hr period is divided into 96 15 min intervals, where 1 is the most recent and 96 is the least recent." ::= { lucentPM4T1E1PMIntEntry 4 } lucentPM4T1E1PMIntIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interface table ifIndex cross reference. The global interface number is computed by using the Most Significant byte as the board ID and the Least Significant 2 bytes represents the interface index. The third byte represents the unit type which will be a T1 or E1. Thus board 0 interface 3 is represented as 0x00050003. The global interface number corresponds to the IfIndex in MIB II." ::= { lucentPM4T1E1PMIntEntry 5 } lucentPM4T1E1PMIntESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of errored seconds, encountered by the line in the last 24 hrs divided into 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 6 } lucentPM4T1E1PMIntSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Seconds encountered by the line for one of the 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 7 } lucentPM4T1E1PMIntSEFSs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Severely Errored Framing Seconds encountered by the line for one of the 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 8 } lucentPM4T1E1PMIntUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Unavailable Seconds encountered by the line for one of the 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 9 } lucentPM4T1E1PMIntCSSs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Controlled Slip Seconds encountered by the line for one of the 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 10 } lucentPM4T1E1PMIntPCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Path Coding Violations encountered by the line for one of the 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 11 } lucentPM4T1E1PMIntLESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Line Errored Seconds encountered by the line for one of the 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 12 } lucentPM4T1E1PMIntBESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Bursty Errored Seconds encountered by the line for one of the 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 13 } lucentPM4T1E1PMIntDMs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Degraded Minutes encountered by the line for one of the 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 14 } lucentPM4T1E1PMIntLCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of Line Code Violations encountered by the line for one of the 96 15 mins intervals." ::= { lucentPM4T1E1PMIntEntry 15 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent T1/E1 Performance Management Total Cumulative Values Table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4T1E1PMTotal OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4T1E1PMTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Performance management table representing the performance statistics of T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose. This table is part of RFC 1406." ::= { lucentPM4PerfMgmt 3 } lucentPM4T1E1PMTotalEntry OBJECT-TYPE SYNTAX LucentPM4T1E1PMIntEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Performance management table entries for all the T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose." INDEX { lucentPM4T1E1PMTotalBoard, lucentPM4T1E1PMTotalUnitType, lucentPM4T1E1PMTotalLineNum, lucentPM4T1E1PMTotalInterval } ::= { lucentPM4T1E1PMTotal 1 } LucentPM4T1E1PMTotalEntry ::= SEQUENCE { lucentPM4T1E1PMTotalBoard INTEGER, lucentPM4T1E1PMTotalUnitType PMUnitType, lucentPM4T1E1PMTotalLineNum INTEGER, lucentPM4T1E1PMTotalIfIndex INTEGER, lucentPM4T1E1PMTotalESs Gauge, lucentPM4T1E1PMTotalSESs Gauge, lucentPM4T1E1PMTotalSEFs Gauge, lucentPM4T1E1PMTotalUASs Gauge, lucentPM4T1E1PMTotalCSSs Gauge, lucentPM4T1E1PMTotalPCVs Gauge, lucentPM4T1E1PMTotalLESs Gauge, lucentPM4T1E1PMTotalBESs Gauge, lucentPM4T1E1PMTotalDMs Gauge, lucentPM4T1E1PMTotalLCVs Gauge } lucentPM4T1E1PMTotalBoard OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Board number of the interface. The global interface number is computed by using the Most Significant nibble of the ifIndex and the Least Significant nibble represents the interface index. Thus board 0 interface 3 is represented as 0x03 or 03 decimal and board 10 interface 3 is represented as 0xa3 or 163 decimal. In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface number corresponds to the IfIndex of MIB II. This table stores the cumulative values for the past 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 1 } lucentPM4T1E1PMTotalUnitType OBJECT-TYPE SYNTAX PMUnitType ACCESS read-only STATUS mandatory DESCRIPTION "Unit type indicates the type of physical or logical device. The unit type for this table is either T1 or E1." ::= { lucentPM4T1E1PMTotalEntry 2 } lucentPM4T1E1PMTotalLineNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Interface number for a given board. The global interface number is computed by using the Most Significant nibble of the ifIndex and the Least Significant nibble represents the interface index. Thus board 0 interface 3 is represented as 0x03 or 03 decimal and board 10 interface 3 is represented as 0xa3 or 163 decimal. In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface number corresponds to the IfIndex in MIB II." ::= { lucentPM4T1E1PMTotalEntry 3 } lucentPM4T1E1PMTotalIfIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "IfIndex cross reference value. This value is obtained from the Board/board number and interface number by combining them into the LSByte. The upper nibble represents the board and the lower nibble represents the line number." ::= { lucentPM4T1E1PMTotalEntry 4 } lucentPM4T1E1PMTotalESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value of errored seconds, encountered by the line in the last 24 hrs." ::= { lucentPM4T1E1PMTotalEntry 5 } lucentPM4T1E1PMTotalSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value Severely Errored Seconds encountered by the line for the 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 6 } lucentPM4T1E1PMTotalSEFSs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value of Severely Errored Framing Seconds encountered by the line for the 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 7 } lucentPM4T1E1PMTotalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value of Unavailable Seconds encountered by the line for the 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 8 } lucentPM4T1E1PMTotalCSSs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value of Controlled Slip Seconds encountered by the line for the 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 9 } lucentPM4T1E1PMTotalPCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value of Path Coding Violations encountered by the line for the 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 10 } lucentPM4T1E1PMTotalLESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value of Line Errored Seconds encountered by the line for the 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 11 } lucentPM4T1E1PMTotalBESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value of Bursty Errored Seconds encountered by the line for the 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 12 } lucentPM4T1E1PMTotalDMs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value of Degraded Minutes encountered by the line for the 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 13 } lucentPM4T1E1PMTotalLCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The cumulative value of Line Code Violations encountered by the line for the 24 hr period." ::= { lucentPM4T1E1PMTotalEntry 14 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Security Management Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4SecurityMgmt OBJECT IDENTIFIER ::= { lucentPM4Mib 7 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Administration Management Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4AcctMgmt OBJECT IDENTIFIER ::= { lucentPM4Mib 8 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Administration Management Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4AcctMgmtComm OBJECT IDENTIFIER ::= { lucentPM4AcctMgmt 1 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent SNMP Read/Write Community Table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4SnmpCommTable OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4SnmpCommEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The SNMP Community Table. This table contains entries to restrict the SNMP get and set operations." ::= { lucentPM4AcctMgmtComm 1 } lucentPM4SnmpCommEntry OBJECT-TYPE SYNTAX LucentPM4SnmpCommEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The entries in the community table." INDEX { lucentPM4SnmpCommName } ::= { lucentPM4SnmpCommTable 1 } LucentPM4SnmpCommEntry ::= SEQUENCE { lucentPM4SnmpCommIndex INTEGER, lucentPM4SnmpCommName DisplayString, lucentPM4SnmpCommIpAddr IpAddress, lucentPM4SnmpCommReadAccess INTEGER, lucentPM4SnmpCommWriteAccess INTEGER, lucentPM4SnmpCommTraps INTEGER, lucentPM4SnmpCommStatus INTEGER, lucentPM4SnmpCommLastError DisplayString } lucentPM4SnmpCommIndex OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-only STATUS mandatory DESCRIPTION "The index of the command in the command table. A MAX of 10 network management stations must be specified along with their community names." ::= { lucentPM4SnmpCommEntry 1 } lucentPM4SnmpCommName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) ACCESS not-accessible STATUS mandatory DESCRIPTION "The name of the SNMP Community for SNMP readers and writers. The size of the string is limited to 32 characters. All characters in the string must be printable." ::= { lucentPM4SnmpCommEntry 2 } lucentPM4SnmpCommIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP Address of the remote community." ::= { lucentPM4SnmpCommEntry 3 } lucentPM4SnmpCommReadAccess OBJECT-TYPE SYNTAX INTEGER { disable(1), ensable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Read access enable or disable for this community. When enabled, it allows read-only variable access using this community string by the SNMP client." ::= { lucentPM4SnmpCommEntry 4 } lucentPM4SnmpCommWriteAccess OBJECT-TYPE SYNTAX INTEGER { disable(1), ensable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Write access enable or disable for this community. When enabled, the agent allows write access to the parameters on the agent by the SNMP clients." ::= { lucentPM4SnmpCommEntry 5 } lucentPM4SnmpCommTraps OBJECT-TYPE SYNTAX INTEGER { disable(1), ensable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Traps receiving capability enable or disable for this community. When enabled, the SNMP agent forwards the traps generated in the box to this SNMP client." ::= { lucentPM4SnmpCommEntry 6 } lucentPM4SnmpCommStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), delete(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The status of the entry for this community. If the status is set to normal, it allows requests from this SNMP client else it discards the requests from this client." ::= { lucentPM4SnmpCommEntry 7 } lucentPM4SnmpCommLastError OBJECT-TYPE SYNTAX DisplayString (SIZE (0..511)) ACCESS read-only STATUS mandatory DESCRIPTION "If there is an error on a request, this variable may contain a message indicating the error." ::= { lucentPM4SnmpCommEntry 8 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Administration Management Group -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4AcctMgmtCallEvent OBJECT IDENTIFIER ::= { lucentPM4AcctMgmt 2 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent Billing/Accounting Information Table -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4AMCallEventTable OBJECT-TYPE SYNTAX SEQUENCE OF LucentPM4AMCallEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Call accounting table containing a list of call events, which may be used for billing purposes." ::= { lucentPM4AcctMgmtCallEvent 1 } lucentPM4AMCallEventEntry OBJECT-TYPE SYNTAX LucentPM4AMCallEventEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The entries in the accounting/billing table." INDEX { lucentPM4AMCEIndex } ::= { lucentPM4AMCallEventTable 1 } LucentPM4AMCallEventEntry ::= SEQUENCE { lucentPM4AMCEIndex INTEGER, lucentPM4AMCETimeStamp INTEGER, lucentPM4AMCEType INTEGER, lucentPM4AMCESvcType INTEGER, lucentPM4AMCEUName DisplayString, lucentPM4AMCEModemBoard INTEGER, lucentPM4AMCEModemID INTEGER, lucentPM4AMCEModemPort DisplayString, lucentPM4AMCEDataRate INTEGER, lucentPM4AMCECallingPartyID DisplayString, lucentPM4AMCECalledPartyID DisplayString, lucentPM4AMCEInOctets INTEGER, lucentPM4AMCEOutOctets INTEGER, lucentPM4AMCECallCharge INTEGER, lucentPM4AMCEDisconnReason INTEGER } lucentPM4AMCEIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Call event index used as an index into the call event table. The table stores call events which may be used for billing." ::= { lucentPM4AMCallEventEntry 1 } lucentPM4AMCETimeStamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp for this event in seconds since the last reboot." ::= { lucentPM4AMCallEventEntry 2 } lucentPM4AMCEType OBJECT-TYPE SYNTAX INTEGER { calloriginated(1), callanswered(2), callcleared(3), servicechanged(4), namechanged(5), baudratechanged(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the type of event associated with this entry in the call event table." ::= { lucentPM4AMCallEventEntry 3 } lucentPM4AMCESvcType OBJECT-TYPE SYNTAX INTEGER { none(1), ppp(2), slip(3), mpp(4), x25(5), combinet(6), frameRelay(7), euraw(8), euui(9), telnet(10), telnetBinary(11), rawTcp(12), terminalServer(13), mp(14), virtualConnect(15), x25DChannel(16) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of service provided to the user. This field is meaningful if the event type is servicechanged(4), or namechanged(5) events. In all other cases, this object must return none(1)." ::= { lucentPM4AMCallEventEntry 4 } lucentPM4AMCEUName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User name of the dialed in user. This object returns the valid user name when the event type is servicechanged(4) or namechanged(5). In all other cases, it returns a NULL." ::= { lucentPM4AMCallEventEntry 5 } lucentPM4AMCEModemBoard OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Board ID of the modem which handled this call. This value can be used to diagnose modem related problems (dropping the call, retraining too frequently etc.)." ::= { lucentPM4AMCallEventEntry 6 } lucentPM4AMCEModemID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the specific modem on a board which handled this call. Can be used to diagnose modem related problems." ::= { lucentPM4AMCallEventEntry 7 } lucentPM4AMCEModemPort OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A textual string containing the name of the serial interface (ie. S0, S1, etc)." ::= { lucentPM4AMCallEventEntry 8 } lucentPM4AMCEDataRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the speed of this connection. Speed is specified as baud rate for modem calls and receive data rate for ISDN calls. This object returns a 0 for call answered and call cleared events." ::= { lucentPM4AMCallEventEntry 9 } lucentPM4AMCECallingPartyID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Calling party ID. This object is valid only for call answered, call originated, and call cleared events. For all invalid event types, this object is set to NULL." ::= { lucentPM4AMCallEventEntry 10 } lucentPM4AMCECalledPartyID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Called party ID. This object is valid only for call answered, call originated, and call cleared events. For all invalid event types, this object is set to NULL." ::= { lucentPM4AMCallEventEntry 11 } lucentPM4AMCEInOctets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total octets received during this call. This object is cleared at the end of each call." ::= { lucentPM4AMCallEventEntry 12 } lucentPM4AMCEOutOctets OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total octets sent out during this call. This object is cleared at the end of each call." ::= { lucentPM4AMCallEventEntry 13 } lucentPM4AMCECallCharge OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Call charge for this call. This object is valid only when the event is call cleared. For all other events this object is set to zero." ::= { lucentPM4AMCallEventEntry 14 } lucentPM4AMCEDisconnReason OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), unknown(2), disconnected(3), clidAuthFailed(4), -- Radius authorization failed clidAuthServTimeout(5), -- Radius client timeout clidAuthRequestCallback(6), preT310Timeout(7), -- disconnect timer timeout noModemAvailable(9), -- all modems assigned to calls noModemNoCarrier(10), -- no carrier detected noModemLossCarrier(11), -- lost carrier during call noModemResultCodes(12), noModemOpenFailed(13), noModemOpenFailedDiag(14), tsUserExit(20), -- user exited the terminal server tsIdleTimeout(21), -- timed out waiting for user input tsExitTelnet(22), -- user exited telnet session tsNoIPAddr(23), -- no IP address, cannot assign one tsExitTcp(24), tsPassWordFail(25), -- exit due to failed password tsRawTCPDisable(26), tsControlC(27), -- Control C detected tsDestroyed(28), tsClosedVirtualConnect(29), -- virtual terminal connection closed tsVirtualConnectDestroyed(30), tsExitRlogin(31), tsRloginBadOption(32), -- bad rlogin command option tsErrorResource(33), mpNullMessageTimeout(35), pppLcpTimeout(40), -- Link Control Protocol timeout pppLcpNegotiateFail(41), -- LCP negotiation failed pppPAPAuthFail(42), -- PAP authentication failed pppCHAPAuthFail(43), -- CHAP authentication failed pppRemoteAuthFail(44), pppRcvTerminate(45), -- received terminate request from far end pppCloseEvent(46), -- PPP close event pppCloseNoNcpsOpened(47), pppCloseUnknownMpBundle(48), pppCloseMpAddChanFail(49), tsExitErrTooMany(50), tsExitErrResource(51), tsExitErrInvalidIP(52), tsExitErrHostName(53), tsExitErrBadPort(54), tsExitErrHostReset(60), tsExitErrConnRefused(61), tsExitErrTimedOut(62), tsExitErrClosed(63), tsExitErrNetUnreach(64), tsExitErrHostUnreach(65), tsExitErrNetAdminUnreach(66), tsExitErrHostAdminUnreach(67), tsExitErrPortUnreach(68), sessTimeOut(100), sessFailSecurity(101), sessCallback(102), invalidProtocol(120), requestByRadiusClient(150), localAdmin(151), localSnmp(152), -- disconnected by SNMP request v110Timeout(160), pppAuthTimeout(170), userCallClearRequest(180), remoteEndHungUp(185), resourceQuiesced(190), maxCallDurationReached(195), lowMemory(201), boardDied(210) } ACCESS read-only STATUS mandatory DESCRIPTION "Reason for the disconnect." ::= { lucentPM4AMCallEventEntry 15 } -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- Lucent PortMaster 4 Traps -- ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ lucentPM4BoardOfflineTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitTrapStatus } DESCRIPTION "Board down trap. The variable bindings in the Trap packet provide information about the chassis name, board number and the trap status. This Trap must be cleared manually." ::= 1 lucentPM4BoardOnlineTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitTrapStatus } DESCRIPTION "Board up trap. The variable bindings in the Trap packet provide information about the chassis name, board number and the trap status. This Trap must be cleared manually." ::= 2 lucentPM4PwrSupFailTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMUnitType, lucentPM4FMUnitIndex, lucentPM4FMUnitTrapStatus } DESCRIPTION "Power supply failed trap. The variable bindings in the Trap packet provide information about the chassis name, power supply unit and the trap status. This Trap must be cleared manually." ::= 3 lucentPM4PwrSupWarnTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMUnitType, lucentPM4FMUnitIndex, lucentPM4FMUnitTrapStatus } DESCRIPTION "Power supply warning trap. The variable bindings in the Trap packet provide information about the chassis name, power supply unit and the trap status. This Trap is issued when the power supply fluctuates between a set threshold. This Trap must be cleared manually." ::= 4 lucentPM4PwrSupRestoredTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMUnitType, lucentPM4FMUnitIndex, lucentPM4FMUnitTrapStatus } DESCRIPTION "Power supply restored trap. The variable bindings in the Trap packet provide information about the chassis name, power supply unit and the trap status. This Trap is issued when a failed power supply is restored. This must be cleared manually." ::= 5 lucentPM4FanFailTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMUnitType, lucentPM4FMUnitIndex, lucentPM4FMUnitTrapStatus } DESCRIPTION "Fan failure trap. The variable bindings in the Trap packet provide information about the chassis name, fan number and the trap status. This Trap must be cleared manually." ::= 6 lucentPM4FanRestoredTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMUnitType, lucentPM4FMUnitIndex, lucentPM4FMUnitTrapStatus } DESCRIPTION "Fan restored trap. The variable bindings in the Trap packet provide information about the chassis name, fan number and the trap status. This Trap is issued when the failed fan is restored. This trap must be cleared manually." ::= 7 lucentPM4BoardTempWarnTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitTrapStatus } DESCRIPTION "Board temperature warning trap. The variable bindings in the Trap packet provide information about the chassis name, unit and the trap status. This Trap is issued when the board temperature exceeds a set threshold value. This trap must be cleared manually." ::= 8 lucentPM4BoardTempNormalTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitTrapStatus } DESCRIPTION "Board temperature normal trap. The variable bindings in the Trap packet provide information about the chassis name, unit and the trap status. This Trap is issued when the board temperature returns to normal. This trap must be cleared manually." ::= 9 lucentPM4BoardTooHotTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitTrapStatus } DESCRIPTION "Board trap. The variable bindings in the Trap packet provide information about the chassis name, board number and the trap status. This Trap must be cleared manually." ::= 10 lucentPM4ModemFailTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitIndex, lucentPM4FMUnitTrapStatus } DESCRIPTION "Modem failure trap. The variable bindings in the Trap packet provide information about the chassis name, modem number and the trap status. This Trap must be cleared manually." ::= 11 lucentPM4T1E1LineDownTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitIndex, lucentPM4FMUnitTrapStatus } DESCRIPTION "T1/E1 Line trap. The variable bindings in the Trap packet provide all the information for the clients to display the Board ID, Line ID and the status of the line. This Trap could be generated when the line comes up or goes down once. It must be cleared manually." ::= 12 lucentPM4T1E1LineUpTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitIndex, lucentPM4FMUnitTrapStatus } DESCRIPTION "T1/E1 Line trap. The variable bindings in the Trap packet provide all the information for the clients to display the Board ID, Line ID and the status of the line. This Trap could be generated when the line comes up or goes down once. It must be cleared manually." ::= 13 lucentPM4T1E1LineThreshTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitIndex, lucentPM4FMUnitTrapStatus } DESCRIPTION "T1/E1 Line trap. The variable bindings in the Trap packet provide all the information for the clients to display the Board ID, Line ID and the trap type. This Trap could be generated when the thresholds for the various performance statistics (ES, SES etc.) exceed. It must be cleared manually." ::= 14 lucentPM4BoardPwrOffTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitType, lucentPM4FMUnitTrapStatus } DESCRIPTION "This trap is issued when the power supply to the board is not enough. The variable bindings in the Trap packet provide information about the chassis name, board/board number and the trap status. This Trap must be cleared manually." ::= 15 lucentPM4RadiusAuthFailTrap TRAP-TYPE ENTERPRISE lucentPM4Traps VARIABLES { sysName, lucentPM4FMBoardIndex, lucentPM4FMUnitIndex } DESCRIPTION "This trap is issued when the Radius authentication fails. This Trap must be cleared manually. The trap provides information about the board and the modem number." ::= 16 END