LIEBERT-UPSTATION-S-UPS-MIB :: lcUpsSwitchedReceptOffDelay

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsLIEBERT-UPSTATION-S-UPS-MIBlcUpsSwitchedReceptOffDelay

lcUpsSwitchedReceptOffDelay

Module: LIEBERT-UPSTATION-S-UPS-MIB

OID (symbolic): LIEBERT-UPSTATION-S-UPS-MIB::lcUpsSwitchedReceptOffDelay

OID (numeric): 1.3.6.1.4.1.476.1.1.1.1.12.2.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Setting this object causes the agent to instruct the UPS to turn off a receptacle after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsReceptOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock.

The command can be cancelled by setting lcUpsSwitchedCancelCommand to the value cancel.

What is lcUpsSwitchedReceptOffDelay?

This read-write integer, in seconds, when set instructs the agent to have the UPS turn this specific receptacle off after the given countdown, firing an lcUpsReceptOffTrap when it completes. It's the counterpart to lcUpsSwitchedReceptOnDelay, used to selectively shed a specific load while keeping others powered.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.1.1.1.12.2.1.4
snmpwalk -v2c -c public <target> LIEBERT-UPSTATION-S-UPS-MIB::lcUpsSwitchedReceptOffDelay

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.1.1.1.12.2.1.4.1
snmpget -v2c -c public <target> LIEBERT-UPSTATION-S-UPS-MIB::lcUpsSwitchedReceptOffDelay.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.476.1.1.1.1.12.2.1.4.1 i <value>

Start monitoring Liebert (Emerson) UPStation S series UPS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-UPSTATION-S-UPS-MIB::lcUpsSwitchedReceptOffDelay OID value, configure state conditions and alerts, and monitor any Liebert (Emerson) UPStation S series UPS from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.1liebertUpsLIEBERT-MICRO-UPS-MIB
1.3.6.1.4.1.476.1.1.1luExtensionsLIEBERT-MICRO-UPS-MIB
1.3.6.1.4.1.476.1.1.1.1luCoreLIEBERT-MICRO-UPS-MIB
1.3.6.1.4.1.476.1.1.1.1.12lcUpsSwitchedReceptaclesLIEBERT-UPS-MIB
1.3.6.1.4.1.476.1.1.1.1.12.2lcUpsSwitchedReceptTableLIEBERT-UPS-MIB
1.3.6.1.4.1.476.1.1.1.1.12.2.1lcUpsSwitchedReceptEntryLIEBERT-UPS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.1.1.1.12.2.1.4lcUpsSwitchedReceptOffDelayLIEBERT-UPSTATION-S-UPS-MIB