LIEBERT-UPSTATION-S-UPS-MIB :: lcUpsSwitchedReceptLabel

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsLIEBERT-UPSTATION-S-UPS-MIBlcUpsSwitchedReceptLabel

lcUpsSwitchedReceptLabel

Module: LIEBERT-UPSTATION-S-UPS-MIB

OID (symbolic): LIEBERT-UPSTATION-S-UPS-MIB::lcUpsSwitchedReceptLabel

OID (numeric): 1.3.6.1.4.1.476.1.1.1.1.12.2.1.7

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: A user-defined text string associated with a switched receptacle. This may be used to describe the load powered from the receptacle. The text string is stored in non-volatile memory.

What is lcUpsSwitchedReceptLabel?

This read-write string (up to 32 characters), stored in non-volatile memory, is a user-defined label for this switched receptacle, typically describing the load plugged into it. Setting a meaningful label here (e.g. 'Core Switch A') saves guesswork when deciding which receptacle to schedule for a delayed shutdown.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.1.1.1.12.2.1.7
snmpwalk -v2c -c public <target> LIEBERT-UPSTATION-S-UPS-MIB::lcUpsSwitchedReceptLabel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.1.1.1.12.2.1.7.1
snmpget -v2c -c public <target> LIEBERT-UPSTATION-S-UPS-MIB::lcUpsSwitchedReceptLabel.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.476.1.1.1.1.12.2.1.7.1 s <value>

Start monitoring Liebert (Emerson) UPStation S series UPS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-UPSTATION-S-UPS-MIB::lcUpsSwitchedReceptLabel OID value, configure state conditions and alerts, and monitor any Liebert (Emerson) UPStation S series UPS from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.1liebertUpsLIEBERT-MICRO-UPS-MIB
1.3.6.1.4.1.476.1.1.1luExtensionsLIEBERT-MICRO-UPS-MIB
1.3.6.1.4.1.476.1.1.1.1luCoreLIEBERT-MICRO-UPS-MIB
1.3.6.1.4.1.476.1.1.1.1.12lcUpsSwitchedReceptaclesLIEBERT-UPS-MIB
1.3.6.1.4.1.476.1.1.1.1.12.2lcUpsSwitchedReceptTableLIEBERT-UPS-MIB
1.3.6.1.4.1.476.1.1.1.1.12.2.1lcUpsSwitchedReceptEntryLIEBERT-UPS-MIB
Numeric OIDNameModule