LEFTHAND-NETWORKS-NSM-CLUSTERING-MIB :: clusModuleStatsStoreLatencyTotal

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LEFTHAND-NETWORKS-NSM-CLUSTERING-MIB › clusModuleStatsStoreLatencyTotal

clusModuleStatsStoreLatencyTotal

Module: LEFTHAND-NETWORKS-NSM-CLUSTERING-MIB

OID (symbolic): LEFTHAND-NETWORKS-NSM-CLUSTERING-MIB::clusModuleStatsStoreLatencyTotal

OID (numeric): 1.3.6.1.4.1.9804.3.1.1.2.12.46.1.27

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The total time spent waiting for IO operations to complete on the storage module.

What is clusModuleStatsStoreLatencyTotal?

Cumulative milliseconds all I/O requests have spent waiting to complete on this node. Admins graph the delta over a polling interval to derive average per-operation latency and spot a slowing node early.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9804.3.1.1.2.12.46.1.27
snmpwalk -v2c -c public <target> LEFTHAND-NETWORKS-NSM-CLUSTERING-MIB::clusModuleStatsStoreLatencyTotal

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9804.3.1.1.2.12.46.1.27.1
snmpget -v2c -c public <target> LEFTHAND-NETWORKS-NSM-CLUSTERING-MIB::clusModuleStatsStoreLatencyTotal.1

Start monitoring HP StorageWorks P4000 SAN storage node (LeftHand SAN/iQ clustering) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LEFTHAND-NETWORKS-NSM-CLUSTERING-MIB::clusModuleStatsStoreLatencyTotal OID value, configure state conditions and alerts, and monitor any HP StorageWorks P4000 SAN storage node (LeftHand SAN/iQ clustering) from a single console.

How to Use in IPNetwork Monitor

Select an HP StorageWorks P4000 SAN storage node (LeftHand SAN/iQ clustering) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type clusModuleStatsStoreLatencyTotal into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total time spent waiting for IO operations to complete on the storage module. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline (in ms), since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9804leftHandNetworksLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3lhnProductsLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3.1lhnNusDevicesMIBsLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3.1.1lhnNusCommonMIBLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3.1.1.2lhnNsmObjectsLEFTHAND-NETWORKS-NSM-MIB
1.3.6.1.4.1.9804.3.1.1.2.12lhnNsmClusteringLEFTHAND-NETWORKS-NSM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9804.3.1.1.2.12.46clusModuleTableLEFTHAND-NETWORKS-NSM-CLUSTERING-MIB
1.3.6.1.4.1.9804.3.1.1.2.12.46.1clusModuleEntryLEFTHAND-NETWORKS-NSM-CLUSTERING-MIB
1.3.6.1.4.1.9804.3.1.1.2.12.46.1.27clusModuleStatsStoreLatencyTotalLEFTHAND-NETWORKS-NSM-CLUSTERING-MIB