| OID symbolic | OID numeric | Type | Access | Description |
| hwSwitchOver | 1.3.6.1.4.1.2011.6.22 | | | This MIB object provides functions of active/standby switchover,
data saving and duplication, and query of data synchronization
status between the active and standby control boards. |
| switchoverMibObject | 1.3.6.1.4.1.2011.6.22.1 | | | |
| hwDataswitchover | 1.3.6.1.4.1.2011.6.22.1.1 | | | |
| INT hwQrydatasyncondition | 1.3.6.1.4.1.2011.6.22.1.1.1 | INTEGER | read-only | The query of the status of data synchronization between
the active and standby control boards. Data synchronization
between the active and standby control boards refers to
that when the active and standby control boards work normally.
The data on the standby control board is synchronized with
that on the active control board.The data synchronization
between the active and standby boards has the following status:
Options:
1. synccompleteness(1)
-indicates that synchronization complete.
2. flashsyncincompleteness(2)
-indicates that operation (loading/backuping/ duplicating/saving/...) is being performed.
3. configbasicdatasyncincompleteness(3)
-indicates that configuration data or basic operation data synchronized incompletely.
4. syncswitchoff(4)
-indicates that the synchronization switch off.
5. peerboardfailure(5)
-indicates that the standby board doesn't exist or fail.
6. dynamicdatasyncincompleteness(6)
-indicates that dynamic service data synchronization is incomplete.
7. patchinconsistent(7)
-indicates that patch files of active board and standby board are inconsistent.
8. patchinconsistentdynamicdatasyncincompleteness(8)
-indicates that patch files of active board and standby board are inconsistent and
dynamic service data synchronization is incomplete. |
| INT hwswitchoverAdminStatus | 1.3.6.1.4.1.2011.6.22.1.1.2 | INTEGER | read-write | Manual active/standby switchover. Active/standby switchover
refers to the process that the standby control board works
as the active control board when the active control board
is faulty or reset, or when the switchover command is issued
manually. If the hwSwitchOverStatus value of the
hwSwitchOverControl object in the table is off(2),
it indicates that the switchover in the system is disabled.
In this case, the manual active/standby switchover cannot be
performed.It is advised to query the value of hwQrydatasyncondition
before setting this value. If the returned value of
hwQrydatasyncondition is synccompleteness(1), the operation is reasonable.
This command will take no effect when the values of
hwAutoswitchoverSwitchStatus, hwAutoswitchoverTime,
hwAutoswitchoverCycle and hwDayNo are set at the same time,
and their original values will remain unchanged.
Options:
1. nooperation(-1) -No operation.
2. switch(1) -Active/standby switchover. |
| INT hwDataSYNSWStatus | 1.3.6.1.4.1.2011.6.22.1.1.3 | INTEGER | read-write | The switch of data synchronization. This object is not supported currently.
Options:
1. on(1) -The switch of data synchronization is on.
2. off(2) -The switch of data synchronization is off.
3. abnormal(3) -System abnormity, switch is on but can't synchronize data
and does not support setting. |
| hwDataSave | 1.3.6.1.4.1.2011.6.22.1.2 | | | |
| INT hwAutoSaveSwitch | 1.3.6.1.4.1.2011.6.22.1.2.1 | INTEGER | read-write | The switch of automatic data saving.
Options:
1. on(1) -indicates that the automatic data saving is enabled.
The system saves the data and configuration files periodically at the specified time.
2. off(2) -indicates that the automatic data saving is disabled.
The system does not save the data and configuration files.
DEFVAL { off } |
| TIK hwAutoSaveCycle | 1.3.6.1.4.1.2011.6.22.1.2.2 | TimeTicks | read-write | The period of automatic data saving. The period is in the unit of 10 ms,
with a value range of 60000-60480000 (10 minutes to one week).
If the data saving is enabled, the default value of this object is 360000 (one hour),
which indicates that the data saving is performed automatically once an hour.
Default: 360000 |
| INT hwImmediateSave | 1.3.6.1.4.1.2011.6.22.1.2.3 | INTEGER | read-write | It is the object for saving the data and the configuration file.
Options:
1. saveDBBDRN(1) -indicates that the data and the configuration file are saved
at the same time.
2. notInSave(2) -indicates that the operation of saving the data and
the configuration file at the same time is not being performed. |
| INT hwAutoSaveTimeSwitch | 1.3.6.1.4.1.2011.6.22.1.2.4 | INTEGER | read-write | The switch of automatic data saving at the absolute time.
Options:
1. on(1) -indicates that the automatic data saving at the absolute time is enabled.
That is, the data is saved automatically at the absolute time.
2. off(2) -indicates that the automatic data saving at the absolute time is disabled.
That is, the data is not saved automatically at the absolute time.
Default { off } |
| TIK hwAutoSaveTime | 1.3.6.1.4.1.2011.6.22.1.2.5 | TimeTicks | read-write | The time of automatic data saving. This value can be converted into the hexadecimal
number 0x00hhmmss (hh representing hour, mm representing minute,
and ss representing second), and then can be converted into the value of
the object through a decimal conversion. If the time of automatic data saving
needs to be set to 22:30:00 the corresponding value is 0x00161E00=1449472,
with 1449472 being the set value.
DEFVAL { 0 } |
| INT hwSaveData | 1.3.6.1.4.1.2011.6.22.1.2.6 | INTEGER | read-write | Immediate saving of the database. Only database is saved through the operation
on this object.
Options:
1. nosavedata(-1) -No database saving is performed in the system.
2. savedata(1) -The command for saving the database is being issued or the database is being saved. |
| INT hwSaveConfiguration | 1.3.6.1.4.1.2011.6.22.1.2.7 | INTEGER | read-write | It is the object for saving the configuration file.
Options:
1. saveconfiguration(1) -indicates that only the configuration file is saved,
the data is not saved.
2. notInsaveconfiguration(2) -indicates that the operation of saving only the
configuration file is not being performed. |
| I32 hwSaveRequestID | 1.3.6.1.4.1.2011.6.22.1.2.8 | Integer32 | read-write | The saving of the operation request ID. The request ID is
used for identifying each saving operation.
It must be unique, and cannot be issued separately.
The operation request ID is used for loading the
reliability table and querying whether each saving operation is successful.
The hwSaveRequestID value of -1 indicates there is no saving operation. |
| INT hwActiveConfiguration | 1.3.6.1.4.1.2011.6.22.1.2.9 | INTEGER | read-write | The activation of the configuration files.
Options:
1. noactiveConfiguration(-1) -indicates that the configuration files are not activated.
2. activeConfiguration(1) -indicates the activation of the configuration files of the active control board.
The activation of the configuration files of the control board causes the system
to reset; therefore, it is recommended that you perform the object hwImmediateSave
before performing this object to save the data and configuration files.
3. activeStandbyConfiguration(2) -indicates the activation of the configuration files of
the standby control board. The activation of the configuration files of the
standby control board causes the standby control board to reset. |
| INT hwActiveConfigurationResult | 1.3.6.1.4.1.2011.6.22.1.2.10 | INTEGER | read-only | The result of Configuration Actived.
Options:
1. partialFailure(1) -indicates that activating the configuration files
of the active control board fails.
2. success(2) -indicates that activating the configuration files of
the active control board is successful.
Default { success } |
| TIK hwAutoSaveCfgChangedtimer | 1.3.6.1.4.1.2011.6.22.1.2.11 | TimeTicks | read-write | The time of saving configuration files automatically.
The time is in the unit of 10 ms,with a value range of
12000-8640000 (two minutes to one day). If the value of
the object hwAutoSaveType is configuration(2), it is
180000 (30 minutes) by default, which indicates that the
configuration files are saved automatically each 30 minutes.
Default: 180000 |
| INT hwAutoSaveType | 1.3.6.1.4.1.2011.6.22.1.2.12 | INTEGER | read-write | The type of automatic saving.
Options:
1. database(1) -indicates the saving of only the database.
2. configuration(2) -indicates the saving of only the configuration files.
3. all(3) -indicates the saving of both database and configuration files.
Default { database } |
| INT hwEraseData | 1.3.6.1.4.1.2011.6.22.1.2.13 | INTEGER | read-write | The erasing of the database. If the configuration data of the active or
standby control board needs to be erased, the database requires to be
erased. After the database is erased, the associated active or standby
control board needs to be reset to make the erasing of the database take effect.
Options:
1. active(1) -indicates the erasing of only the database of the active control board.
2. standby(2) -indicates the erasing of only the database of the standby control board.
3. all(3) -indicates the erasing of both databases of the active and standby control boards.
4. noEraseData(4) -indicates that the operation of erasing the database is not being performed. |
| hwRollBack | 1.3.6.1.4.1.2011.6.22.1.3 | | | |
| INT hwRollBackOper | 1.3.6.1.4.1.2011.6.22.1.3.1 | INTEGER | read-write | This object is used to roll back the system.
Options:
1. initial(1) -Indicates the initial value.
2. rollback(2) -Indicates the system is to be rolled back. |
| hwDuplicate | 1.3.6.1.4.1.2011.6.22.1.4 | | | |
| INT hwSynDataAdminStatus | 1.3.6.1.4.1.2011.6.22.1.4.1 | INTEGER | read-write | Duplication of the host programs, databases, multi-lingual files,
configuration files, and package files from the active control
board to the standby control board.
Options:
1. program(1) -indicates the duplication of the host programs.
2. data(2) -indicates the duplication of the databases.
3. resLocal(3) -indicates the duplication of local multi-lingual files.
4. resGeneral(4) -indicates the duplication of universal multi-lingual files.
5. configuration(5) -indicates the duplication of configuration files.
6. packetfile(6) -indicates the duplication of package files.
7. nosyscontent(255) -indicates that no file is duplicated. |
| I32 hwDuplicateProcess | 1.3.6.1.4.1.2011.6.22.1.4.2 | Integer32 | read-only | The process of duplication.
Range: 0-100 |
| I32 hwCloneRequestID | 1.3.6.1.4.1.2011.6.22.1.4.3 | Integer32 | read-write | The request ID for operation information table.
This object is not supported currently. |
| hwDataChange | 1.3.6.1.4.1.2011.6.22.1.5 | | | |
| U32 hwSystemDataChange | 1.3.6.1.4.1.2011.6.22.1.5.1 | Unsigned32 | read-only | Querying whether the system configuration (database and configuration files)
changes. For the value of this object, 0 indicates that the system configuration
does not change, and other values indicate that the system configuration changes.
When the system is just started and the system configuration does not change,
the initial value of this object is 0. Each time the host configuration changes,
the value of this object increases by 1 continuously. If the system is reset,
the value turns to 0 again. |
| INT hwSystemDataState | 1.3.6.1.4.1.2011.6.22.1.5.2 | INTEGER | read-only | Querying whether the current database is null. A null database refers to the database
with no configuration data.
Options:
1. blank(1) -indicates that the database is null.
2. modified(2) -indicates that the database is not null.
Default { blank } |
| hwSwitchOverTraps | 1.3.6.1.4.1.2011.6.22.2 | | | |
| hwSwitchOverTrapsOids | 1.3.6.1.4.1.2011.6.22.2.1 | | | |
| I32 hwConfigSN | 1.3.6.1.4.1.2011.6.22.2.1.1 | Integer32 | accessible-for-notify | The count of saving the system configurations. |
| I32 hwSynSchedulguage | 1.3.6.1.4.1.2011.6.22.2.1.2 | Integer32 | accessible-for-notify | Progress of the synchronization between the active and standby control boards.
Range: 0-100 |
| I32 hwTrapSaveResult | 1.3.6.1.4.1.2011.6.22.2.1.3 | Integer32 | accessible-for-notify | Result of the data saving.
The returned value 0 indicates that the data is saved successfully.
The returned value 1 indicates that the data saving fails. |
| hwSwitchOverCommonTraps | 1.3.6.1.4.1.2011.6.22.2.2 | | | |
| hwSwitchOverCommonTrapsPrefix | 1.3.6.1.4.1.2011.6.22.2.2.0 | | | |
| NTF hwSysCfgChangedTrap | 1.3.6.1.4.1.2011.6.22.2.2.0.1 | | | This trap message is reported when the system database is being saved. |
| NTF hwSynScheduleTrap | 1.3.6.1.4.1.2011.6.22.2.2.0.2 | | | This trap message, indicating the synchronization progress, is reported during the data synchronization
between the active and standby control boards. |
| NTF hwSaveConfigStartTrap | 1.3.6.1.4.1.2011.6.22.2.2.0.3 | | | This trap is reported when configuration file starts to be saved. |
| NTF hwSaveConfigCompleteTrap | 1.3.6.1.4.1.2011.6.22.2.2.0.4 | | | This trap is reported when configuration file is saved completely. |
| hwSwitchOverAlarmTraps | 1.3.6.1.4.1.2011.6.22.2.3 | | | |
| hwSwitchOverAlarmTrapsPrefix | 1.3.6.1.4.1.2011.6.22.2.3.0 | | | |
| NTF hwSwitchoverTrap | 1.3.6.1.4.1.2011.6.22.2.3.0.1 | | | This trap is reported when the switchover occurs between the active and standby boards. |
| NTF hwBatchBackupStartTrap | 1.3.6.1.4.1.2011.6.22.2.3.0.2 | | | This trap is reported when the system batch hot backup starts. |
| NTF hwBatchBackupCompleteTrap | 1.3.6.1.4.1.2011.6.22.2.3.0.3 | | | This trap is reported when the system batch hot backup is complete. |
| NTF hwInUpgradeTrap | 1.3.6.1.4.1.2011.6.22.2.3.0.4 | | | This trap is reported when the system enters the in-service upgrade scenario. |
| NTF hwSoftVersionInconsistentTrap | 1.3.6.1.4.1.2011.6.22.2.3.0.5 | | | This trap is reported when software versions of active and standby boards are inconsistent. |
| hwSwitchOverControl | 1.3.6.1.4.1.2011.6.22.3 | | | |
| INT hwSwitchOverStatus | 1.3.6.1.4.1.2011.6.22.3.1 | INTEGER | read-write | The switch of the active/standby switchover.
Options:
1. on(1) -indicates that the active/standby switchover is enabled.
2. off(2) -indicates that the active/standby switchover is disabled.
If the active/standby switchover is disabled, the system cannot
perform data synchronization between the active and standby control
boards, manual active/standby switchover,
and automatic active/standby switchover.
Default:on(1) |
| INT hwSwitchOverPeriod | 1.3.6.1.4.1.2011.6.22.3.2 | INTEGER | read-write | The period of the active/standby switchover.
Options:
1. day(1) -indicates that the switchover is performed once a day.
2. week(2) -indicates that the switchover is performed once a week.
3. month(3) -indicates that the switchover is performed once a month.
Default { day } |
| I32 hwSwitchOverInverseDayNo | 1.3.6.1.4.1.2011.6.22.3.3 | Integer32 | read-write | Days since the periodic switchover has been started. Its value
range depends on the value of object hwSwitchOverPeriod.
When hwSwitchOverPeriod is set to day(1), the default value of this object is 1;
When hwSwitchOverPeriod is set to week(2), the value range of this object is 1-7
When hwSwitchOverPeriod is set to month(3), the value range of this object is 1-31.
Default:1. |
| OCT hwSwitchOverTime | 1.3.6.1.4.1.2011.6.22.3.4 | OCTET STRING | read-write | Time when switchover will happen. Time is set by a string in the format of hh:mm:ss.
The value range of hh is from 00 to 23. The value range of mm is from 00 to 59.
The value range of ss is from 00 to 59.
Default:03:00:00 |
| INT hwAutoSwitchOverStatus | 1.3.6.1.4.1.2011.6.22.3.5 | INTEGER | read-write | Status of auto switchover function. If the value of switchover switch hwSwitchOverStatus
is off(2), the system cannot perform the active/standby switchover.
Options:
1.on(1) -indicates that the automatic switchover is enabled. In this case,
if the values of the hwSwitchOverPeriod, hwSwitchOverInverseDayNo,
and hwSwitchOverTime are set, the system performs the automatic switchover periodically;
if the values of the hwSwitchOverPeriod, hwSwitchOverInverseDayNo, and hwSwitchOverTime
are not set or only partially set, the objects that are not set with values use the default
value, and the system also performs the automatic switchover periodically.
2.off(2) -indicates that the automatic switchover is disabled. If this object is not set with a value,
the system does not perform the automatic switchover.
Default { off } |