HUAWEI-LSW-DEV-ADM-MIB

MIB Reference — IPNetwork Monitor

All MIBsHUAWEI-LSW-DEV-ADM-MIB

Organization: Hangzhou H3C Technologies Co., Ltd.

Last Updated: 2009-03-19

Category: Device Management, Vendor: Huawei

Description:

Huawei LAN switch device administration MIB providing platform-specific configuration and status objects for Huawei enterprise LAN switches.

Imported Objects

From HUAWEI-3COM-OID-MIB

lswCommonOBJECT-IDENTITY

From SNMPv2-SMI

Integer32
IpAddress
MODULE-IDENTITY
OBJECT-TYPE
Unsigned32

From SNMPv2-TC

DateAndTime
DisplayString
TEXTUAL-CONVENTION

What Is HUAWEI-LSW-DEV-ADM-MIB?

HUAWEI-LSW-DEV-ADM-MIB is a Huawei enterprise MIB that provides platform-specific device administration objects for Huawei's campus/enterprise LAN switch (LSW) product line. It exposes device-level configuration and administrative status data, covering aspects such as system configuration state, administrative control settings, and platform identification for the switch. Network management systems polling objects under the HUAWEI-LSW-DEV-ADM-MIB OID subtree use it to confirm administrative and configuration health of the switch, complementing standard hardware telemetry—uptime, CPU/memory load, and power/fan status—reported by companion Huawei system MIBs. It is registered under Huawei's enterprise SMI OID structure and is typically deployed alongside other Huawei LSW-series MIBs covering interfaces, VLANs, and environmental monitoring. It is used in enterprise and campus network environments running Huawei LAN switches that are managed via SNMP through Huawei's eSight or third-party network management platforms.

IPNetwork Monitor allows you to monitor SNMP objects defined in HUAWEI-LSW-DEV-ADM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • device administrative configuration status
  • system configuration state
  • administrative control settings
  • platform/version identification

Supported Devices

  • Huawei CloudEngine S5732-H (2024) — full-10GE access LAN switch, 24/48-port models

Monitoring Examples

No specific sample objects were provided for this module, so a concrete polling scenario cannot be built from real object names here. In practice, administrators would enumerate the scalars and tables registered under the Huawei enterprise OID tree for this MIB—typically covering configuration state, administrative mode, and version identification for the LAN switch—using a MIB browser or NMS to confirm the switch's administrative status. This module would ordinarily be polled alongside standard interface (IF-MIB) and system (MIB-II) objects to build a complete picture of switch health, since HUAWEI-LSW-DEV-ADM-MIB itself focuses narrowly on device administration rather than interface or environmental telemetry.

OIDs
OID symbolicOID numericTypeAccessDescription
hwLswDeviceAdmin1.3.6.1.4.1.2011.2.23.1.18The latest baseline.
hwLswSystemPara1.3.6.1.4.1.2011.2.23.1.18.1
IP hwLswSysIpAddr1.3.6.1.4.1.2011.2.23.1.18.1.1IpAddressread-onlySystem IP address, which is the primary IP address of the VLAN interface that has smallest VLAN ID and is configured IP address.
IP hwLswSysIpMask1.3.6.1.4.1.2011.2.23.1.18.1.2IpAddressread-onlyMask of the system IP address.
I32 hwLswSysCpuRatio1.3.6.1.4.1.2011.2.23.1.18.1.3Integer32read-onlyCPU usage of the system in accuracy of 1%, and the range of value is 1 to 100.
STR hwLswSysVersion1.3.6.1.4.1.2011.2.23.1.18.1.4DisplayStringread-onlyInformation of the system version.
DAT hwLswSysTime1.3.6.1.4.1.2011.2.23.1.18.1.5DateAndTimeread-writeSystem time.
INT hwLswSysUNMCastDropEnable1.3.6.1.4.1.2011.2.23.1.18.1.6INTEGERread-writeEnable or disable discarding of unknown multicast packet.
I32 hwLswSysManagementVlan1.3.6.1.4.1.2011.2.23.1.18.1.7Integer32read-writeSystem management VLAN.
STR hwLswSysVlanRange1.3.6.1.4.1.2011.2.23.1.18.1.8DisplayStringread-writeSystem VLAN range, if set VLAN range, must bind mangement IP/Mask.
IP hwLswSysManagementIpAddr1.3.6.1.4.1.2011.2.23.1.18.1.9IpAddressread-writeSystem IP address.
IP hwLswSysManagementIpMask1.3.6.1.4.1.2011.2.23.1.18.1.10IpAddressread-writeMask of the system IP address.
I32 hwMacAddressCountPort1.3.6.1.4.1.2011.2.23.1.18.1.11Integer32read-onlySupportted MAC address number on port.
I32 hwMacAddressCountMachine1.3.6.1.4.1.2011.2.23.1.18.1.12Integer32read-onlySupportted MAC address number on machine.
U32 hwLswSysPhyMemory1.3.6.1.4.1.2011.2.23.1.18.1.13Unsigned32read-onlyThe memory of physical. For the distributed device, it represents the memory size on the master slot. If the amount of physical memory exceeds 4,294,967,295 bytes, the value remains 4,294,967,295 bytes.
U32 hwLswSysMemory1.3.6.1.4.1.2011.2.23.1.18.1.14Unsigned32read-onlyThe memory of system. Note that the system memory means the memory can be used by the software platform. For the distributed device, it represents the memory size on the master slot. If the amount of system memory exceeds 4,294,967,295 bytes, the value remains 4,294,967,295 bytes.
U32 hwLswSysMemoryUsed1.3.6.1.4.1.2011.2.23.1.18.1.15Unsigned32read-onlyThe system memory in use. Note that the system memory means the memory can be used by the software platform. For the distributed device, it represents the memory size on the master slot. If the amount of used memory exceeds 4,294,967,295 bytes, the value remains 4,294,967,295 bytes.
U32 hwLswSysMemoryRatio1.3.6.1.4.1.2011.2.23.1.18.1.16Unsigned32read-onlyThe percentage of system memory in use. Note that the system memory means the memory can be used by the software platform. hwLswSysMemoryUsed hwLswSysMemoryRatio = -------------------- hwLswSysMemory For the distributed device, it represents the memory used ratio on the master slot.
I32 hwLswSysTemperature1.3.6.1.4.1.2011.2.23.1.18.1.17Integer32read-onlyThe temperature of system. For the distributed device, it represents the temperature on the master slot.
hwLswSlotConf1.3.6.1.4.1.2011.2.23.1.18.4
hwLswFrameTable1.3.6.1.4.1.2011.2.23.1.18.4.2not-accessibleFrame information table.
hwLswFrameEntry1.3.6.1.4.1.2011.2.23.1.18.4.2.1not-accessibleFrame description table entry.
I32 hwLswFrameIndex1.3.6.1.4.1.2011.2.23.1.18.4.2.1.1Integer32read-onlyThe unique index of frame.
I32 hwLswFrameType1.3.6.1.4.1.2011.2.23.1.18.4.2.1.2Integer32read-onlyFrame type.
STR hwLswFrameDesc1.3.6.1.4.1.2011.2.23.1.18.4.2.1.3DisplayStringread-writeFrame description.
I32 hwLswSlotNumber1.3.6.1.4.1.2011.2.23.1.18.4.2.1.4Integer32read-onlyNumber of slots of the current frame.
INT hwLswFrameAdminStatus1.3.6.1.4.1.2011.2.23.1.18.4.2.1.5INTEGERread-onlyThe Status of frame.
hwLswSlotTable1.3.6.1.4.1.2011.2.23.1.18.4.3not-accessibleSlot description table.
hwLswSlotEntry1.3.6.1.4.1.2011.2.23.1.18.4.3.1not-accessibleSlot description table entry.
I32 hwLswSlotIndex1.3.6.1.4.1.2011.2.23.1.18.4.3.1.1Integer32read-onlySlot index. When the slot is empty, listed as vacant slot.
HWL hwLswSlotType1.3.6.1.4.1.2011.2.23.1.18.4.3.1.2HwLswTypeOfSlotread-onlySlot type. BOM number is recommended.
STR hwLswSlotDesc1.3.6.1.4.1.2011.2.23.1.18.4.3.1.3DisplayStringread-writeSlot description.
I32 hwLswSlotCpuRatio1.3.6.1.4.1.2011.2.23.1.18.4.3.1.4Integer32read-onlyCPU usage of the slot in accuracy of 1%, and the range of value is 1 to 100.
STR hwLswSlotPcbVersion1.3.6.1.4.1.2011.2.23.1.18.4.3.1.5DisplayStringread-onlyHardware version of the board.
STR hwLswSlotSoftwareVersion1.3.6.1.4.1.2011.2.23.1.18.4.3.1.6DisplayStringread-onlySoftware version of the board.
I32 hwLswSubslotNumber1.3.6.1.4.1.2011.2.23.1.18.4.3.1.7Integer32read-onlyNumber of the cards of the board.
INT hwLswSlotAdminStatus1.3.6.1.4.1.2011.2.23.1.18.4.3.1.8INTEGERread-onlySlot status.
INT hwLswSlotOperStatus1.3.6.1.4.1.2011.2.23.1.18.4.3.1.9INTEGERread-writeSlot operation status.
U32 hwLswSlotPhyMemory1.3.6.1.4.1.2011.2.23.1.18.4.3.1.10Unsigned32read-onlyThe memory of physical on the board. If the amount of physical memory exceeds 4,294,967,295 bytes, the value remains 4,294,967,295 bytes.
U32 hwLswSlotMemory1.3.6.1.4.1.2011.2.23.1.18.4.3.1.11Unsigned32read-onlyThe memory of system on the board. Note that the system memory means the memory can be used by the software platform. If the amount of system memory exceeds 4,294,967,295 bytes, the value remains 4,294,967,295 bytes.
U32 hwLswSlotMemoryUsed1.3.6.1.4.1.2011.2.23.1.18.4.3.1.12Unsigned32read-onlyThe system memory in use on the board. Note that the system memory means the memory can be used by the software platform. If the amount of used memory exceeds 4,294,967,295 bytes, the value remains 4,294,967,295 bytes.
U32 hwLswSlotMemoryRatio1.3.6.1.4.1.2011.2.23.1.18.4.3.1.13Unsigned32read-onlyThe percentage of system memory in use on the board. Note that the system memory means the memory can be used by the software platform.
I32 hwLswSlotTemperature1.3.6.1.4.1.2011.2.23.1.18.4.3.1.14Integer32read-onlyThe temperature of system on the board.
hwLswSubslotTable1.3.6.1.4.1.2011.2.23.1.18.4.4not-accessibleSubslot description table.
hwLswSubslotEntry1.3.6.1.4.1.2011.2.23.1.18.4.4.1not-accessibleSubslot description table entry.
I32 hwLswSubslotIndex1.3.6.1.4.1.2011.2.23.1.18.4.4.1.1Integer32read-onlySubslot index.
HWL hwLswSubslotType1.3.6.1.4.1.2011.2.23.1.18.4.4.1.2HwLswTypeOfSlotread-onlyType of the pinch board in the subslot.
I32 hwLswSubslotPortNum1.3.6.1.4.1.2011.2.23.1.18.4.4.1.3Integer32read-onlyNumber of physical ports in the pinch board.
INT hwLswSubslotAdminStatus1.3.6.1.4.1.2011.2.23.1.18.4.4.1.4INTEGERread-onlyStatus of the pinch board in the subslot.
I32 hwLswSubslotFirstIfIndex1.3.6.1.4.1.2011.2.23.1.18.4.4.1.5Integer32read-onlyThe value of ifIndex of the first physical port in the pinch board.
hwLswPortTable1.3.6.1.4.1.2011.2.23.1.18.4.5not-accessiblePort configuration table.
hwLswPortEntry1.3.6.1.4.1.2011.2.23.1.18.4.5.1not-accessiblePort configuration table entry.
I32 hwLswPortIndex1.3.6.1.4.1.2011.2.23.1.18.4.5.1.1Integer32read-onlyThe port number on the device. The first port number is 1, which is reserved if the port does not exist.
INT hwLswPortType1.3.6.1.4.1.2011.2.23.1.18.4.5.1.2INTEGERread-onlyNormally the port type is the same as its card type. When there are different types of ports in one card, use the actual port type.
I32 hwLswPortIfindex1.3.6.1.4.1.2011.2.23.1.18.4.5.1.3Integer32read-onlyThe value of ifIndex of the port.
INT hwLswPortIsPlugged1.3.6.1.4.1.2011.2.23.1.18.4.5.1.4INTEGERread-onlyPort is plugged or not.
hwLswPortLoopbackTable1.3.6.1.4.1.2011.2.23.1.18.4.6not-accessiblePort loopback test table.
hwLswPortLoopbackEntry1.3.6.1.4.1.2011.2.23.1.18.4.6.1not-accessiblePort loopback test table entry.
INT hwLswPortLoopbackIsSupport1.3.6.1.4.1.2011.2.23.1.18.4.6.1.1INTEGERread-onlyThe loopback type can be supported by current port.
INT hwLswPortLoopbackOperate1.3.6.1.4.1.2011.2.23.1.18.4.6.1.2INTEGERread-writePort loopback operate type. Read operation not supported.
INT hwLswPortLoopbackResult1.3.6.1.4.1.2011.2.23.1.18.4.6.1.3INTEGERread-onlyLoopback test result of the port, used for checking if the test is successful. Only after the testing will the query value on the node make sense.
INT hwLswPortLoopbackAutoStopSupport1.3.6.1.4.1.2011.2.23.1.18.4.6.1.4INTEGERread-onlyWhether this port support NEED-MANNUL-NOLOOP mode or not.
INT hwLswPortLoopbackRemoteResult1.3.6.1.4.1.2011.2.23.1.18.4.6.1.5INTEGERread-writeThe remote loopback test result of the port, used for checking if the test is successful. Only after the testing will the query value on the node make sense.
INT hwLswPortLoopbackLocalResult1.3.6.1.4.1.2011.2.23.1.18.4.6.1.6INTEGERread-writeThe local loopback test result of the port, used for checking if the test is successful. Only after the testing will the query value on the node make sense.
INT hwLswPortLoopbackInternalResult1.3.6.1.4.1.2011.2.23.1.18.4.6.1.7INTEGERread-writeThe internal loopback test result of the port, used for checking if the test is successful. Only after the testing will the query value on the node make sense.
INT hwLswPortLoopbackExternalResult1.3.6.1.4.1.2011.2.23.1.18.4.6.1.8INTEGERread-writeThe external loopback test result of the port, used for checking if the test is successful. Only after the testing will the query value on the node make sense.
hwLswFabricTable1.3.6.1.4.1.2011.2.23.1.18.4.7not-accessibleThis table contains the information of fabric.
hwLswFabricEntry1.3.6.1.4.1.2011.2.23.1.18.4.7.1not-accessibleAn entry in hwLswFabricTable.
I32 hwLswFabricChannelIndex1.3.6.1.4.1.2011.2.23.1.18.4.7.1.1Integer32not-accessibleThe channel number of fabric.
I32 hwLswFabricUtilIn1.3.6.1.4.1.2011.2.23.1.18.4.7.1.2Integer32read-onlyIngress utilization of fabric.
I32 hwLswFabricUtilOut1.3.6.1.4.1.2011.2.23.1.18.4.7.1.3Integer32read-onlyEgress utilization of fabric.
I32 hwLswFabricPeakIn1.3.6.1.4.1.2011.2.23.1.18.4.7.1.4Integer32read-onlyIngress peak of utilization for fabric.
DAT hwLswFabricPeakInTime1.3.6.1.4.1.2011.2.23.1.18.4.7.1.5DateAndTimeread-onlyIngress peak time of utilization for fabric.
I32 hwLswFabricPeakOut1.3.6.1.4.1.2011.2.23.1.18.4.7.1.6Integer32read-onlyEgress peak of utilization for fabric.
DAT hwLswFabricPeakOutTime1.3.6.1.4.1.2011.2.23.1.18.4.7.1.7DateAndTimeread-onlyEgress peak time of utilization for fabric.

FAQ

What kind of data does HUAWEI-LSW-DEV-ADM-MIB expose on a Huawei enterprise LAN switch?
It provides platform-specific configuration and status objects for administering the switch, giving an SNMP manager a way to read and adjust Huawei-specific device settings that sit alongside the standard interface/bridge data reported by vendor-neutral MIBs.

When would an administrator reach for HUAWEI-LSW-DEV-ADM-MIB instead of a standard MIB like IF-MIB?
When the task requires viewing or setting Huawei-specific device administration configuration and status that isn't represented in vendor-neutral interface MIBs — for example, confirming platform-level settings unique to the Huawei LAN switch line during a device audit.

RFC description

Huawei LAN switch device administration MIB; manages device-level configuration and administrative parameters on Huawei switches.

Start monitoring Huawei LAN switch (LSW series, device administration) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download HUAWEI-LSW-DEV-ADM-MIB