All MIBs › HPNSAECC-MIB › hpnsaEccSBEOverflow
hpnsaEccSBEOverflow
Module: HPNSAECC-MIB
OID (symbolic): HPNSAECC-MIB::hpnsaEccSBEOverflow
OID (numeric): 1.3.6.1.4.1.11.2.23.6.0.4354
Node type: NOTIFICATION-TYPE
Description: Error logging for ECC single-bit errors has been disabled due to too many SBE's detected in a short time period
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' HPNSAECC-MIB::hpnsaEccSBEOverflow snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.11.2.23.6.0.4354
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:52415->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (228109503) 26 days, 9:38:15.03 SNMPv2-MIB::snmpTrapOID.0 = OID: HPNSAECC-MIB::hpnsaEccSBEOverflow
Start monitoring HP NetServer/ProLiant server (legacy ECC memory error counters) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPNSAECC-MIB::hpnsaEccSBEOverflow OID value, configure state conditions and alerts, and monitor any HP NetServer/ProLiant server (legacy ECC memory error counters) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.23 | hpnsa | HPHOTSWAP2SUBSYSTEM-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.23.6 | hpnsaECC | HPNSAECC-MIB |
| 1.3.6.1.4.1.11.2.23.6.0.4354 | hpnsaEccSBEOverflow | HPNSAECC-MIB |