All MIBs › HPN-ICF-FLASH-MAN-MIB › hpnicfFlhRemovable
hpnicfFlhRemovable
Module: HPN-ICF-FLASH-MAN-MIB
OID (symbolic): HPN-ICF-FLASH-MAN-MIB::hpnicfFlhRemovable
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.2.1.9
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-only
Description: The value indicates whether the flash indexed can be removed or not. The true(1) value indicates the flash device CAN be removed.
What is hpnicfFlhRemovable?
Reports whether this flash device can be physically removed from the chassis (true) or is a fixed, built-in component (false), which matters when planning hot-swap maintenance.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.2.1.9 snmpwalk -v2c -c public <target> HPN-ICF-FLASH-MAN-MIB::hpnicfFlhRemovable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.2.1.9.1 snmpget -v2c -c public <target> HPN-ICF-FLASH-MAN-MIB::hpnicfFlhRemovable.1
Start monitoring HP Networking (H3C-derived) equipment (Flash card management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-FLASH-MAN-MIB::hpnicfFlhRemovable OID value, configure state conditions and alerts, and monitor any HP Networking (H3C-derived) equipment (Flash card management) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.5 | hpnicfFlash | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1 | hpnicfFlashManMIBObjects | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1 | hpnicfFlashDevice | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.2 | hpnicfFlashTable | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.2.1 | hpnicfFlashEntry | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.2.1.9 | hpnicfFlhRemovable | HPN-ICF-FLASH-MAN-MIB |