All MIBs › HPN-ICF-FLASH-MAN-MIB › hpnicfFlhPartSpaceFree
hpnicfFlhPartSpaceFree
Module: HPN-ICF-FLASH-MAN-MIB
OID (symbolic): HPN-ICF-FLASH-MAN-MIB::hpnicfFlhPartSpaceFree
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.1.1.5
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-only
Description: The flash partition's free space. If the free space of the flash partition exceeds 2,147,483,647 bytes, hpnicfFlhPartHCSpaceFree specifies the actual free space.
What is hpnicfFlhPartSpaceFree?
The amount of unused space remaining in this flash partition, in bytes; this deprecated 32-bit field is superseded by hpnicfFlhPartHCSpaceFree for partitions with more than about 2GB free.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.1.1.5 snmpwalk -v2c -c public <target> HPN-ICF-FLASH-MAN-MIB::hpnicfFlhPartSpaceFree
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.1.1.5.1 snmpget -v2c -c public <target> HPN-ICF-FLASH-MAN-MIB::hpnicfFlhPartSpaceFree.1
Start monitoring HP Networking (H3C-derived) equipment (Flash card management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-FLASH-MAN-MIB::hpnicfFlhPartSpaceFree OID value, configure state conditions and alerts, and monitor any HP Networking (H3C-derived) equipment (Flash card management) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.5 | hpnicfFlash | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1 | hpnicfFlashManMIBObjects | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1 | hpnicfFlashDevice | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4 | hpnicfFlashPartitions | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.1 | hpnicfFlhPartitionTable | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.1.1 | hpnicfFlhPartitionEntry | HPN-ICF-FLASH-MAN-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.1.1.5 | hpnicfFlhPartSpaceFree | HPN-ICF-FLASH-MAN-MIB |