HPN-ICF-FLASH-MAN-MIB :: hpnicfFlhFileHCSize

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHPN-ICF-FLASH-MAN-MIBhpnicfFlhFileHCSize

hpnicfFlhFileHCSize

Module: HPN-ICF-FLASH-MAN-MIB

OID (symbolic): HPN-ICF-FLASH-MAN-MIB::hpnicfFlhFileHCSize

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.2.1.1.6

Node type: OBJECT-TYPE

Type: CounterBasedGauge64

Access: read-only

Description: The file size in bytes. This node is a 64-bit substitue for hpnicfFlhFileSize.

What is hpnicfFlhFileHCSize?

The size of this file in bytes as a 64-bit gauge, replacing the older 32-bit hpnicfFlhFileSize for files larger than about 2GB.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.2.1.1.6
snmpwalk -v2c -c public <target> HPN-ICF-FLASH-MAN-MIB::hpnicfFlhFileHCSize

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.2.1.1.6.1
snmpget -v2c -c public <target> HPN-ICF-FLASH-MAN-MIB::hpnicfFlhFileHCSize.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> hpnicfFlhFileHCSize.1

Start monitoring HP Networking (H3C-derived) equipment (Flash card management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-FLASH-MAN-MIB::hpnicfFlhFileHCSize OID value, configure state conditions and alerts, and monitor any HP Networking (H3C-derived) equipment (Flash card management) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.5hpnicfFlashHPN-ICF-FLASH-MAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.5.1hpnicfFlashManMIBObjectsHPN-ICF-FLASH-MAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.5.1.1hpnicfFlashDeviceHPN-ICF-FLASH-MAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4hpnicfFlashPartitionsHPN-ICF-FLASH-MAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.2hpnicfFlhFilesHPN-ICF-FLASH-MAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.2.1hpnicfFlhFileTableHPN-ICF-FLASH-MAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.2.1.1hpnicfFlhFileEntryHPN-ICF-FLASH-MAN-MIB
1.3.6.1.4.1.11.2.14.11.15.2.5.1.1.4.2.1.1.6hpnicfFlhFileHCSizeHPN-ICF-FLASH-MAN-MIB