All MIBs › HP-ICF-VG-RPTR › hpVgMonGlbHighPriorityOctets
hpVgMonGlbHighPriorityOctets
Module: HP-ICF-VG-RPTR
OID (symbolic): HP-ICF-VG-RPTR::hpVgMonGlbHighPriorityOctets
OID (numeric): 1.3.6.1.4.1.11.2.14.11.3.2.1.1.5
Node type: OBJECT-TYPE
Type: Counter32
Access: read-only
Description: This object is a count of the total number of octets contained in high priority frames that have been received on all ports of this repeater. This counter is a summation of the values of the icfVgPortHighPriorityOctets counter for all of the ports in this repeater.
Note that this counter will roll over very quickly. It is provided for backward compatibility for Network Management protocols that do not support 64 bit counters (e.g. SNMP version 1).
What is hpVgMonGlbHighPriorityOctets?
The total number of octets carried in high-priority frames received across all ports on this repeater; a 32-bit counter kept for SNMPv1 compatibility, since it rolls over quickly under load.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.3.2.1.1.5 snmpwalk -v2c -c public <target> HP-ICF-VG-RPTR::hpVgMonGlbHighPriorityOctets
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.3.2.1.1.5.1 snmpget -v2c -c public <target> HP-ICF-VG-RPTR::hpVgMonGlbHighPriorityOctets.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> hpVgMonGlbHighPriorityOctets.1
Start monitoring HP 100VG-AnyLAN repeater/concentrator (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-ICF-VG-RPTR::hpVgMonGlbHighPriorityOctets OID value, configure state conditions and alerts, and monitor any HP 100VG-AnyLAN repeater/concentrator (legacy) from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.3 | hpicfVg | HP-ICF |
| 1.3.6.1.4.1.11.2.14.11.3.2 | hpVgMonitor | HP-ICF |
| 1.3.6.1.4.1.11.2.14.11.3.2.1 | hpVgMonitorGlobal | HP-ICF |
| 1.3.6.1.4.1.11.2.14.11.3.2.1.1 | hpVgMonCounters | HP-ICF |
| Numeric OID | Name | Module |
|---|---|---|