HP-ICF-DHCPv6-SNOOP-MIB :: hpicfDSnoopV6CSForwards

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HP-ICF-DHCPv6-SNOOP-MIB › hpicfDSnoopV6CSForwards

hpicfDSnoopV6CSForwards

Module: HP-ICF-DHCPv6-SNOOP-MIB

OID (symbolic): HP-ICF-DHCPv6-SNOOP-MIB::hpicfDSnoopV6CSForwards

OID (numeric): 1.3.6.1.4.1.11.2.14.11.5.1.102.1.2.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: Number of snooped DHCPv6 packets that were successfully forwarded from untrusted client ports towards trusted DHCPv6 server ports.

What is hpicfDSnoopV6CSForwards?

Counts DHCPv6 client packets that were successfully forwarded from untrusted client ports toward trusted DHCPv6 server ports, a healthy baseline number to watch when confirming snooping is passing legitimate client traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.5.1.102.1.2.1
snmpwalk -v2c -c public <target> HP-ICF-DHCPv6-SNOOP-MIB::hpicfDSnoopV6CSForwards

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.5.1.102.1.2.1.1
snmpget -v2c -c public <target> HP-ICF-DHCPv6-SNOOP-MIB::hpicfDSnoopV6CSForwards.1

Start monitoring HP Networking switch (DHCPv6 Snooping) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-ICF-DHCPv6-SNOOP-MIB::hpicfDSnoopV6CSForwards OID value, configure state conditions and alerts, and monitor any HP Networking switch (DHCPv6 Snooping) from a single console.

How to Use in IPNetwork Monitor

Select an HP Networking switch (DHCPv6 Snooping) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hpicfDSnoopV6CSForwards into the Find box to locate it in the OID tree, then select it and click OK. It reports the number of snooped DHCPv6 packets that were successfully forwarded from untrusted client ports towards trusted DHCPv6 server ports. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.5hpicfSwitchCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.5.1hpSwitchCONFIG-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.5.1.102hpicfDSnoopV6HP-ICF-DHCPv6-SNOOP-MIB
1.3.6.1.4.1.11.2.14.11.5.1.102.1hpicfDSnoopV6ObjectsHP-ICF-DHCPv6-SNOOP-MIB
1.3.6.1.4.1.11.2.14.11.5.1.102.1.2hpicfDSnoopV6GlobalStatsHP-ICF-DHCPv6-SNOOP-MIB
1.3.6.1.4.1.11.2.14.11.5.1.102.1.2.1hpicfDSnoopV6CSForwardsHP-ICF-DHCPv6-SNOOP-MIB