HM2-NETCONFIG-MIB :: hm2NetOobMgmtAction

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-NETCONFIG-MIB › hm2NetOobMgmtAction

hm2NetOobMgmtAction

Module: HM2-NETCONFIG-MIB

OID (symbolic): HM2-NETCONFIG-MIB::hm2NetOobMgmtAction

OID (numeric): 1.3.6.1.4.1.248.11.20.1.6.50

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object, when read, always returns a value of other(1). Setting the object to activate(2) causes a reconfiguration of the out-of-band IP protocol stack with the current values of hm2NetOobMgmtLocalIPAddr, hm2NetOobMgmtPrefixLength and hm2NetOobMgmtGatewayIPAddr.

What is hm2NetOobMgmtAction?

Always reads back as other(1); setting it to activate(2) commits the pending out-of-band IP address, prefix length, and gateway settings to the running configuration. An admin uses this as the commit step after staging new OOB network settings, mirroring hm2NetAction for the in-band interface.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.20.1.6.50
snmpwalk -v2c -c public <target> HM2-NETCONFIG-MIB::hm2NetOobMgmtAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.20.1.6.50.1
snmpget -v2c -c public <target> HM2-NETCONFIG-MIB::hm2NetOobMgmtAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.20.1.6.50.1 i <value>

Start monitoring Hirschmann HiOS industrial Ethernet switch (management network config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-NETCONFIG-MIB::hm2NetOobMgmtAction OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch (management network config) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.20hm2NetConfigMibHM2-NETCONFIG-MIB
1.3.6.1.4.1.248.11.20.1hm2NetConfigMibObjectsHM2-NETCONFIG-MIB
1.3.6.1.4.1.248.11.20.1.6hm2NetOobMgmtGroupHM2-NETCONFIG-MIB
1.3.6.1.4.1.248.11.20.1.6.50hm2NetOobMgmtActionHM2-NETCONFIG-MIB