All MIBs › HM2-DIAGNOSTIC-MIB › hm2PortMonitorConditionCrcFragmentsInterval
hm2PortMonitorConditionCrcFragmentsInterval
Module: HM2-DIAGNOSTIC-MIB
OID (symbolic): HM2-DIAGNOSTIC-MIB::hm2PortMonitorConditionCrcFragmentsInterval
OID (numeric): 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.1
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: Measure interval in seconds (5-180s) for CrcFragments detection.
What is hm2PortMonitorConditionCrcFragmentsInterval?
Sets, in seconds (5-180), the measurement window used to count CRC errors/fragments when detecting that condition on this interface.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.1 snmpwalk -v2c -c public <target> HM2-DIAGNOSTIC-MIB::hm2PortMonitorConditionCrcFragmentsInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.1.1 snmpget -v2c -c public <target> HM2-DIAGNOSTIC-MIB::hm2PortMonitorConditionCrcFragmentsInterval.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.1.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> hm2PortMonitorConditionCrcFragmentsInterval.1
Start monitoring Hirschmann industrial Ethernet switch (self-test/signal-contact diagnostics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-DIAGNOSTIC-MIB::hm2PortMonitorConditionCrcFragmentsInterval OID value, configure state conditions and alerts, and monitor any Hirschmann industrial Ethernet switch (self-test/signal-contact diagnostics) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.248 | hirschmann | HIRSCHMANN-GENERIC-ERROR-MIB |
| 1.3.6.1.4.1.248.11 | hm2ConfigurationMibs | HM2-TC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.248.11.22 | hm2DiagnosticMib | HM2-DIAGNOSTIC-MIB |
| 1.3.6.1.4.1.248.11.22.1 | hm2DiagnosticMibObjects | HM2-DIAGNOSTIC-MIB |
| 1.3.6.1.4.1.248.11.22.1.7 | hm2PortMonitorGroup | HM2-DIAGNOSTIC-MIB |
| 1.3.6.1.4.1.248.11.22.1.7.3 | hm2PortMonitorConditionGroup | HM2-DIAGNOSTIC-MIB |
| 1.3.6.1.4.1.248.11.22.1.7.3.3 | hm2PortMonitorConditionCrcFragmentsGroup | HM2-DIAGNOSTIC-MIB |
| 1.3.6.1.4.1.248.11.22.1.7.3.3.1 | hm2PortMonitorConditionCrcFragmentsIntfTable | HM2-DIAGNOSTIC-MIB |
| 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1 | hm2PortMonitorConditionCrcFragmentsIntfEntry | HM2-DIAGNOSTIC-MIB |
| 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.1 | hm2PortMonitorConditionCrcFragmentsInterval | HM2-DIAGNOSTIC-MIB |