HM2-DIAGNOSTIC-MIB :: hm2PortMonitorConditionCrcFragmentsCount

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-DIAGNOSTIC-MIB › hm2PortMonitorConditionCrcFragmentsCount

hm2PortMonitorConditionCrcFragmentsCount

Module: HM2-DIAGNOSTIC-MIB

OID (symbolic): HM2-DIAGNOSTIC-MIB::hm2PortMonitorConditionCrcFragmentsCount

OID (numeric): 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: CrcFragments counter (1-1000000).

What is hm2PortMonitorConditionCrcFragmentsCount?

Sets how many CRC-errored/fragment frames (1-1,000,000) within the measurement interval are needed to trigger the CRC-fragments condition on this interface.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.2
snmpwalk -v2c -c public <target> HM2-DIAGNOSTIC-MIB::hm2PortMonitorConditionCrcFragmentsCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.2.1
snmpget -v2c -c public <target> HM2-DIAGNOSTIC-MIB::hm2PortMonitorConditionCrcFragmentsCount.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.2.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> hm2PortMonitorConditionCrcFragmentsCount.1

Start monitoring Hirschmann industrial Ethernet switch (self-test/signal-contact diagnostics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-DIAGNOSTIC-MIB::hm2PortMonitorConditionCrcFragmentsCount OID value, configure state conditions and alerts, and monitor any Hirschmann industrial Ethernet switch (self-test/signal-contact diagnostics) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.22hm2DiagnosticMibHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1hm2DiagnosticMibObjectsHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.7hm2PortMonitorGroupHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.7.3hm2PortMonitorConditionGroupHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.7.3.3hm2PortMonitorConditionCrcFragmentsGroupHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.7.3.3.1hm2PortMonitorConditionCrcFragmentsIntfTableHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.7.3.3.1.1hm2PortMonitorConditionCrcFragmentsIntfEntryHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.7.3.3.1.1.2hm2PortMonitorConditionCrcFragmentsCountHM2-DIAGNOSTIC-MIB