HM2-DIAGNOSTIC-MIB :: hm2DevSecSenseIec61850MmsEnabled

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-DIAGNOSTIC-MIB › hm2DevSecSenseIec61850MmsEnabled

hm2DevSecSenseIec61850MmsEnabled

Module: HM2-DIAGNOSTIC-MIB

OID (symbolic): HM2-DIAGNOSTIC-MIB::hm2DevSecSenseIec61850MmsEnabled

OID (numeric): 1.3.6.1.4.1.248.11.22.1.3.3.1.18

Node type: OBJECT-TYPE

Type: HmEnabledStatus

Access: read-write

Description: Enable or disable to check if IEC 61850 MMS is enabled on the switch.

What is hm2DevSecSenseIec61850MmsEnabled?

Enables or disables the security check that flags whether the IEC 61850 MMS industrial protocol service is enabled on the switch.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.22.1.3.3.1.18
snmpwalk -v2c -c public <target> HM2-DIAGNOSTIC-MIB::hm2DevSecSenseIec61850MmsEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.22.1.3.3.1.18.1
snmpget -v2c -c public <target> HM2-DIAGNOSTIC-MIB::hm2DevSecSenseIec61850MmsEnabled.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.22.1.3.3.1.18.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> hm2DevSecSenseIec61850MmsEnabled.1

Start monitoring Hirschmann industrial Ethernet switch (self-test/signal-contact diagnostics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-DIAGNOSTIC-MIB::hm2DevSecSenseIec61850MmsEnabled OID value, configure state conditions and alerts, and monitor any Hirschmann industrial Ethernet switch (self-test/signal-contact diagnostics) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.22hm2DiagnosticMibHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1hm2DiagnosticMibObjectsHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.3hm2DiagDeviceMonitorGroupHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.3.3hm2DeviceSecurityGroupHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.3.3.1hm2DevSecConfigGroupHM2-DIAGNOSTIC-MIB
1.3.6.1.4.1.248.11.22.1.3.3.1.18hm2DevSecSenseIec61850MmsEnabledHM2-DIAGNOSTIC-MIB