GEPARALLELUPS-MIB :: upsInputLineBads

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GEPARALLELUPS-MIB › upsInputLineBads

upsInputLineBads

Module: GEPARALLELUPS-MIB

OID (symbolic): GEPARALLELUPS-MIB::upsInputLineBads

OID (numeric): 1.3.6.1.4.1.818.1.1.10.3.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.(*)

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.818.1.1.10.3.1
snmpwalk -v2c -c public <target> GEPARALLELUPS-MIB::upsInputLineBads

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.818.1.1.10.3.1.1
snmpget -v2c -c public <target> GEPARALLELUPS-MIB::upsInputLineBads.1

Start monitoring GE Digital Energy parallel/redundant UPS system with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GEPARALLELUPS-MIB::upsInputLineBads OID value, configure state conditions and alerts, and monitor any GE Digital Energy parallel/redundant UPS system from a single console.

How to Use in IPNetwork Monitor

Select a GE Digital Energy parallel/redundant UPS system as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type upsInputLineBads into the Find box to locate it in the OID tree, then select it and click OK. It reports a count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.818imvGE-PARALLELUPS
1.3.6.1.4.1.818.1geHardwareGE-PARALLELUPS
1.3.6.1.4.1.818.1.1geUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.10geGenericUPSGE-PARALLELUPS
1.3.6.1.4.1.818.1.1.10.3upsInput_genGE-PARALLELUPS
Numeric OIDNameModule
1.3.6.1.4.1.818.1.1.10.3.1upsInputLineBadsGEPARALLELUPS-MIB