Fore-E3-MIB :: e3FramingLOSs

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-E3-MIB › e3FramingLOSs

e3FramingLOSs

Module: Fore-E3-MIB

OID (symbolic): Fore-E3-MIB::e3FramingLOSs

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.4

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of seconds in which Loss Of Signal (LOS) errors were detected by the E3 Receive Framer block.

What is e3FramingLOSs?

Count of seconds in which the E3 Receive Framer detected a Loss Of Signal (LOS) condition, a sign of a broken or disconnected physical link.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.4
snmpwalk -v2c -c public <target> Fore-E3-MIB::e3FramingLOSs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.4.1
snmpget -v2c -c public <target> Fore-E3-MIB::e3FramingLOSs.1

Start monitoring FORE Systems ATM switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-E3-MIB::e3FramingLOSs OID value, configure state conditions and alerts, and monitor any FORE Systems ATM switches from a single console.

How to Use in IPNetwork Monitor

Select an FORE Systems ATM switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type e3FramingLOSs into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of seconds in which Loss Of Signal (LOS) errors were detected by the E3 Receive Framer block. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.5foreE3Fore-E3-MIB
1.3.6.1.4.1.326.2.2.1.1.5.2e3StatsGroupFore-E3-MIB
1.3.6.1.4.1.326.2.2.1.1.5.2.1e3FramingTableFore-E3-MIB
1.3.6.1.4.1.326.2.2.1.1.5.2.1.1e3FramingEntryFore-E3-MIB
1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.4e3FramingLOSsFore-E3-MIB