All MIBs › FSC-RAID-MIB › svrLogicalDriveRaidLevel
svrLogicalDriveRaidLevel
Module: FSC-RAID-MIB
OID (symbolic): FSC-RAID-MIB::svrLogicalDriveRaidLevel
OID (numeric): 1.3.6.1.4.1.231.2.49.1.6.2.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: RAID level
What is svrLogicalDriveRaidLevel?
The RAID level this logical drive is configured with, encoded as an integer (e.g. raid5(9), raid10(6), raid6(13)). Knowing the RAID level tells an admin how much fault tolerance the array has and how a rebuild after a disk failure will behave.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.49.1.6.2.1.5 snmpwalk -v2c -c public <target> FSC-RAID-MIB::svrLogicalDriveRaidLevel
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.49.1.6.2.1.5.1 snmpget -v2c -c public <target> FSC-RAID-MIB::svrLogicalDriveRaidLevel.1
Start monitoring Fujitsu Siemens Computers (FSC)/Fujitsu PRIMERGY server (RAID controller/disk health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FSC-RAID-MIB::svrLogicalDriveRaidLevel OID value, configure state conditions and alerts, and monitor any Fujitsu Siemens Computers (FSC)/Fujitsu PRIMERGY server (RAID controller/disk health) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.2 | sniProductMibs | Application-Monitoring-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.2.49 | fscRAIDMIB | FSC-RAID-MIB |
| 1.3.6.1.4.1.231.2.49.1 | svrObjects | FSC-RAID-MIB |
| 1.3.6.1.4.1.231.2.49.1.6 | svrLogicalDriveInfo | FSC-RAID-MIB |
| 1.3.6.1.4.1.231.2.49.1.6.2 | svrLogicalDriveTable | FSC-RAID-MIB |
| 1.3.6.1.4.1.231.2.49.1.6.2.1 | svrLogicalDriveEntry | FSC-RAID-MIB |
| 1.3.6.1.4.1.231.2.49.1.6.2.1.5 | svrLogicalDriveRaidLevel | FSC-RAID-MIB |