FSC-RAID-MIB DEFINITIONS ::= BEGIN -- MibName=fscRAIDMIB -- -- ServerView RAID Manager MIB - Unified RAID system monitoring for internal RAID controllers -- -- MIB Revision: 1.6.28 -- -- Copyright (c) Fujitsu Technology Solutions 2009 - 2014 -- All rights reserved -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString FROM RFC1213-MIB Counter, Gauge, enterprises FROM RFC1155-SMI; -- The Windows MIB compiler doesn't support IMPORTS. -- In this case uncomment the next few lines. -- -- DisplayString ::= OCTET STRING -- enterprises OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) private(4) 1 } sni OBJECT IDENTIFIER ::= { enterprises 231 } sniProductMibs OBJECT IDENTIFIER ::= { sni 2 } fscRAIDMIB OBJECT IDENTIFIER ::= { sniProductMibs 49 } svrObjects OBJECT IDENTIFIER ::= { fscRAIDMIB 1 } svrNotifications OBJECT IDENTIFIER ::= { fscRAIDMIB 2 } -- -- Textual conventions -- CompStatus ::= INTEGER { ok(1), prefailure(2), failure(3) } TrueFalse ::= INTEGER { false(1), true(2) } Index ::= INTEGER (0..2147483647) -- ********************************************************************************************** -- -- GROUP svrAgentInfo -- DESCRIPTION "This group defines agent specific objects like agent name, -- vendor name and versions" -- -- svrAgentInfo group: 1.3.6.1.4.1.231.2.49.1.1 -- -- ********************************************************************************************** svrAgentInfo OBJECT IDENTIFIER ::= { svrObjects 1 } svrAgentId OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Agent identification string" ::= { svrAgentInfo 1 } svrAgentCompany OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Agent's company name (e.g. Fujitsu)" ::= { svrAgentInfo 2 } svrAgentVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Agent's version string (e.g. 1.05)" ::= { svrAgentInfo 3 } svrAgentBuild OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Compilation time and date of agent program" ::= { svrAgentInfo 4 } -- ********************************************************************************************** -- -- GROUP svrAgentOptions -- DESCRIPTION "This group defines global agent options - currently not used" -- -- svrAgentOptions group: 1.3.6.1.4.1.231.2.49.1.2 -- -- ********************************************************************************************** svrAgentOptions OBJECT IDENTIFIER ::= { svrObjects 2 } -- ********************************************************************************************** -- -- GROUP svrStatus -- DESCRIPTION "This group defines status summary values" -- -- svrStatus group: 1.3.6.1.4.1.231.2.49.1.3 -- -- ********************************************************************************************** svrStatus OBJECT IDENTIFIER ::= { svrObjects 3 } svrStatusLogicalDrives OBJECT-TYPE SYNTAX CompStatus ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive status (summary status of all logical drives at all controllers)" ::= { svrStatus 1 } svrStatusPhysicalDevices OBJECT-TYPE SYNTAX CompStatus ACCESS read-only STATUS mandatory DESCRIPTION "Device status (summary status of all devices at all controllers)" ::= { svrStatus 2 } svrStatusControllers OBJECT-TYPE SYNTAX CompStatus ACCESS read-only STATUS mandatory DESCRIPTION "Controller status (summary status of all controllers, including status of all devices and logical drives of this controller)" ::= { svrStatus 3 } svrStatusOverall OBJECT-TYPE SYNTAX CompStatus ACCESS read-only STATUS mandatory DESCRIPTION "Overall status (overall summary status)" ::= { svrStatus 4 } -- ********************************************************************************************** -- -- GROUP svrControllerInfo -- DESCRIPTION "This group describes the available RAID controllers and their capabilities" -- -- svrControllerInfo group: 1.3.6.1.4.1.231.2.49.1.4 -- -- ********************************************************************************************** svrControllerInfo OBJECT IDENTIFIER ::= { svrObjects 4 } svrNumberRaidControllers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of available ServerView RAID Manager managed RAID controllers/adapters (number of entries in svrCtrlTable)" ::= { svrControllerInfo 1 } -- ---------------------------------------------------------------------------------------------- -- -- TABLE svrCtrlTable -- STATUS mandatory -- DESCRIPTION "Available RAID adapters (supported by ServerView RAID Manager)" -- -- svrCtrlTable: 1.3.6.1.4.1.231.2.49.1.4.2 -- -- ---------------------------------------------------------------------------------------------- svrCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF SvrCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Available RAID adapters (supported by ServerView RAID Manager)" ::= { svrControllerInfo 2 } svrCtrlEntry OBJECT-TYPE SYNTAX SvrCtrlEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { svrCtrlNr } ::= { svrCtrlTable 1 } SvrCtrlEntry ::= SEQUENCE { svrCtrlNr Index, svrCtrlModelName DisplayString, svrCtrlManufacturerName DisplayString, svrCtrlBusLocation DisplayString, svrCtrlBusLocationText DisplayString, svrCtrlHardwareRevision DisplayString, svrCtrlFirmwareRevision DisplayString, svrCtrlBiosRevision DisplayString, svrCtrlNumberChannels INTEGER, svrCtrlMaxChannelInUse INTEGER, svrCtrlNumberPhysDisks INTEGER, svrCtrlNumberLogicalDrives INTEGER, svrCtrlCacheSize INTEGER, svrCtrlBBUStatus INTEGER, svrCtrlStatus CompStatus, svrCtrlInterface INTEGER, svrCtrlBusLocationBus INTEGER, svrCtrlBusLocationDevice INTEGER, svrCtrlBusLocationFunction INTEGER, svrCtrlBusLocationSlot INTEGER, svrCtrlSerialNo DisplayString, svrCtrlDriverName DisplayString, svrCtrlDriverRevision DisplayString, svrCtrlBBUStatusEx INTEGER, svrCtrlDisplayName DisplayString, svrCtrlHostName DisplayString, svrCtrlUEFIDriverRevision DisplayString, svrCtrlBusLocationSegment INTEGER } svrCtrlNr OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Unique controller number (index; starts with 1)" ::= { svrCtrlEntry 1 } svrCtrlModelName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller model name" ::= { svrCtrlEntry 2 } svrCtrlManufacturerName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller manufacturer name" ::= { svrCtrlEntry 3 } svrCtrlBusLocation OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "String describing the location of a RAID controller on PCI or SCSI bus (e.g. 'PCI:Bus=1&Device=6&Function=1&Slot=4', 'SCSI:Host=0&Channel=1&Target=2&LUN=3' or 'LAN:IP=10.0.0.33:5566'...)" ::= { svrCtrlEntry 4 } svrCtrlBusLocationText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "String describing the bus location of a RAID controller as a human readable text (e.g. 'PCI Bus 1, Device 6'...)" ::= { svrCtrlEntry 5 } svrCtrlHardwareRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller hardware version/revision" ::= { svrCtrlEntry 6 } svrCtrlFirmwareRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller firmware version/revision" ::= { svrCtrlEntry 7 } svrCtrlBiosRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller BIOS option ROM version/revision" ::= { svrCtrlEntry 8 } svrCtrlNumberChannels OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of channels/ports at the controller" ::= { svrCtrlEntry 9 } svrCtrlMaxChannelInUse OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of the hightest channel/port that is in use" ::= { svrCtrlEntry 10 } svrCtrlNumberPhysDisks OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of disks" ::= { svrCtrlEntry 11 } svrCtrlNumberLogicalDrives OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of logical drives" ::= { svrCtrlEntry 12 } svrCtrlCacheSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size of onboard cache on the controller (in MBytes)" ::= { svrCtrlEntry 13 } svrCtrlBBUStatus OBJECT-TYPE SYNTAX INTEGER { notAvailable(1), onLine(2), onBattery(3), onBatteryLow(4), charging(5), discharging(6), failed(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of onboard battery backup unit (deprecated)" ::= { svrCtrlEntry 14 } svrCtrlStatus OBJECT-TYPE SYNTAX CompStatus ACCESS read-only STATUS mandatory DESCRIPTION "Overall controller status (including status of all disks and logical drives)" ::= { svrCtrlEntry 15 } svrCtrlInterface OBJECT-TYPE SYNTAX INTEGER { other(1), scsi(2), ide(3), ieee1394(4), sata(5), sas(6), fc(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Disk connection interface" ::= { svrCtrlEntry 16 } svrCtrlBusLocationBus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Bus number of a RAID controller on PCI or SCSI bus" ::= { svrCtrlEntry 17 } svrCtrlBusLocationDevice OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device number of a RAID controller on PCI or SCSI bus" ::= { svrCtrlEntry 18 } svrCtrlBusLocationFunction OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Function number of a RAID controller on PCI or SCSI bus" ::= { svrCtrlEntry 19 } svrCtrlBusLocationSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Slot number of a RAID controller on PCI or SCSI bus" ::= { svrCtrlEntry 20 } svrCtrlSerialNo OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller serial number" ::= { svrCtrlEntry 21 } svrCtrlDriverName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller driver name" ::= { svrCtrlEntry 22 } svrCtrlDriverRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller driver version/revision" ::= { svrCtrlEntry 23 } svrCtrlBBUStatusEx OBJECT-TYPE SYNTAX INTEGER { unknown(1), notInstalled(2), normal(3), charging(4), discharging(5), warning(6), failed(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of onboard battery backup unit" ::= { svrCtrlEntry 24 } svrCtrlDisplayName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller display name" ::= { svrCtrlEntry 25 } svrCtrlHostName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Name or IP address of server where controller is hosted, empty for local host" ::= { svrCtrlEntry 26 } svrCtrlUEFIDriverRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Controller UEFI driver version/revision" ::= { svrCtrlEntry 27 } svrCtrlBusLocationSegment OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Segment number of a RAID controller on PCI bus" ::= { svrCtrlEntry 28 } -- ********************************************************************************************** -- -- GROUP svrPhysicalDeviceInfo -- DESCRIPTION "This group contains information about devices" -- -- svrPhysicalDeviceInfo group: 1.3.6.1.4.1.231.2.49.1.5 -- -- ********************************************************************************************** svrPhysicalDeviceInfo OBJECT IDENTIFIER ::= { svrObjects 5 } svrNumberPhysicalDevices OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of available devices (number of entries in svrPhysicalDeviceTable)" ::= { svrPhysicalDeviceInfo 1 } -- ---------------------------------------------------------------------------------------------- -- -- TABLE svrPhysicalDeviceTable -- STATUS mandatory -- DESCRIPTION "Table containing devices (disks)" -- -- svrPhysicalDeviceTable: 1.3.6.1.4.1.231.2.49.1.5.2 -- -- ---------------------------------------------------------------------------------------------- svrPhysicalDeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF SvrPhysicalDeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing devices (disks)" ::= { svrPhysicalDeviceInfo 2 } svrPhysicalDeviceEntry OBJECT-TYPE SYNTAX SvrPhysicalDeviceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { svrPhysicalDeviceCtrlNr, svrPhysicalDeviceChannel, svrPhysicalDeviceTarget, svrPhysicalDeviceLUN } ::= { svrPhysicalDeviceTable 1 } SvrPhysicalDeviceEntry ::= SEQUENCE { svrPhysicalDeviceCtrlNr Index, svrPhysicalDeviceChannel Index, svrPhysicalDeviceTarget Index, svrPhysicalDeviceLUN Index, svrPhysicalDeviceModelName DisplayString, svrPhysicalDeviceVendorName DisplayString, svrPhysicalDeviceCapacity INTEGER, svrPhysicalDeviceMaxTransferRate INTEGER, svrPhysicalDeviceType INTEGER, svrPhysicalDeviceConfiguredDisk TrueFalse, svrPhysicalDeviceInterface INTEGER, svrPhysicalDeviceErrors Counter, svrPhysicalDeviceNrBadBlocks Counter, svrPhysicalDeviceSmartStatus INTEGER, svrPhysicalDeviceStatus INTEGER, svrPhysicalDeviceFirmwareRevision DisplayString, svrPhysicalDeviceSerialNumber DisplayString, svrPhysicalDeviceForeignConfig TrueFalse, svrPhysicalDeviceIdx INTEGER, svrPhysicalDeviceStatusEx INTEGER, svrPhysicalDeviceCapacityMB INTEGER, svrPhysicalDeviceEnclosureNumber INTEGER, svrPhysicalDeviceSlot INTEGER, svrPhysicalDeviceDisplayName DisplayString, svrPhysicalDevicePowerStatus INTEGER } svrPhysicalDeviceCtrlNr OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Controller number (same as index in svrCtrlTable)" ::= { svrPhysicalDeviceEntry 1 } svrPhysicalDeviceChannel OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Channel/Port number (index) SCSI: bus (channel) number SAS/SATA: port number a value >= 65000 means unknown/invalid (e.g. missing device)" ::= { svrPhysicalDeviceEntry 2 } svrPhysicalDeviceTarget OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Device target number (index) SCSI: target number (SCSI ID) SAS/SATA: device number a value >= 65000 means unknown/invalid (e.g. missing device)" ::= { svrPhysicalDeviceEntry 3 } svrPhysicalDeviceLUN OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Device logical unit number (index) SCSI: logical unit number (SCSI LUN) SAS/SATA: not used (0)" ::= { svrPhysicalDeviceEntry 4 } svrPhysicalDeviceModelName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device model name" ::= { svrPhysicalDeviceEntry 5 } svrPhysicalDeviceVendorName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device vendor (manufacturer) name" ::= { svrPhysicalDeviceEntry 6 } svrPhysicalDeviceCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Disk capacity (GBytes)" ::= { svrPhysicalDeviceEntry 7 } svrPhysicalDeviceMaxTransferRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum transfer rate (MBytes/second) of the disk interface" ::= { svrPhysicalDeviceEntry 8 } svrPhysicalDeviceType OBJECT-TYPE SYNTAX INTEGER { other(1), disk(2), tape(3), printer(4), processor(5), writeOnce(6), cdRomDvd(7), scanner(8), optical(9), jukebox(10), communicationDevice(11), host(98), unknown(99) } ACCESS read-only STATUS mandatory DESCRIPTION "Device type" ::= { svrPhysicalDeviceEntry 9 } svrPhysicalDeviceConfiguredDisk OBJECT-TYPE SYNTAX TrueFalse ACCESS read-only STATUS mandatory DESCRIPTION "This disk is a configured part of RAID array" ::= { svrPhysicalDeviceEntry 10 } svrPhysicalDeviceInterface OBJECT-TYPE SYNTAX INTEGER { other(1), scsi(2), ide(3), ieee1394(4), sata(5), sas(6), fc(7) } ACCESS read-only STATUS mandatory DESCRIPTION "Disk connection interface" ::= { svrPhysicalDeviceEntry 11 } svrPhysicalDeviceErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of read/write/seek or other errors (summary of all error counters)" ::= { svrPhysicalDeviceEntry 12 } svrPhysicalDeviceNrBadBlocks OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of detected bad blocks (0 = unknown or no bad blocks)" ::= { svrPhysicalDeviceEntry 13 } svrPhysicalDeviceSmartStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), failurePredicted(2), smartNotAvailable(3), smartMonitoringDisabled(4) } ACCESS read-only STATUS mandatory DESCRIPTION "SMART status" ::= { svrPhysicalDeviceEntry 14 } svrPhysicalDeviceStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), noDisk(2), online(3), ready(4), failed(5), rebuilding(6), hotspareGlobal(7), hotspareDedicated(8), offline(9), unconfiguredFailed(10), formatting(11), dead(12) } ACCESS read-only STATUS mandatory DESCRIPTION "Device status (deprecated): noDisk(2): device is not a hard disk online(3): device is available and working properly ready(4): device can be used for new configuration failed(5): device is available but no longer working rebuilding(6): device is restoring fault tolerance hotspareGlobal(7): device is a hot spare device for use in any array hotspareDedicated(8): device is a hot spare device for use in a dedicated array offline(9): device is set to non-working state unconfiguredFailed(10): device is not configured but a failure has occurred formatting(15): device is currently being formatted dead(12): device is not available or not responding" ::= { svrPhysicalDeviceEntry 15 } svrPhysicalDeviceFirmwareRevision OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device firmware version/revision" ::= { svrPhysicalDeviceEntry 16 } svrPhysicalDeviceSerialNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device serial number" ::= { svrPhysicalDeviceEntry 17 } svrPhysicalDeviceForeignConfig OBJECT-TYPE SYNTAX TrueFalse ACCESS read-only STATUS mandatory DESCRIPTION "This device has a foreign configuration" ::= { svrPhysicalDeviceEntry 18 } svrPhysicalDeviceIdx OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device SVRAID object index" ::= { svrPhysicalDeviceEntry 19 } svrPhysicalDeviceStatusEx OBJECT-TYPE SYNTAX INTEGER { unknown(1), noDisk(2), available(3), operational(4), failed(5), rebuilding(6), globalHotSpare(7), dedicatedHotSpare(8), offline(9), unconfiguredFailed(10), failedMissing(11), copyBack(12), redundantCopy(13), waiting(14), preparing(15), migrating(16), jbod(17), shielded(18), clearing(19), erasing(20) } ACCESS read-only STATUS mandatory DESCRIPTION "Device status: noDisk(2): device is not a hard disk available(3): device is unconfigured and working properly operational(4): device is configured and working properly failed(5): device is configured but is no longer working rebuilding(6): device is restoring fault tolerance globalHotSpare(7): device is a hot spare device for use in any array dedicatedHotSpare(8): device is a hot spare device for use in a dedicated array offline(9): device is set to non-working state unconfiguredFailed(10): device is not configured but is no longer working failedMissing(11): device is not available anymore copyBack(12): device is target for copyback operation redundantCopy(13): device is target for redundant copy operation waiting(14): device is waiting for copyback to start preparing(15): device is starting up migrating(16): device is part of migration process jbod(17): device is exposed to operating system shielded(18): device is under diagnostic test clearing(19): device is being cleared erasing(20): device is begin erased" ::= { svrPhysicalDeviceEntry 20 } svrPhysicalDeviceCapacityMB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Disk capacity (MBytes)" ::= { svrPhysicalDeviceEntry 21 } svrPhysicalDeviceEnclosureNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device enclosure number (-1 unknown or not in an enclosure)" ::= { svrPhysicalDeviceEntry 22 } svrPhysicalDeviceSlot OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device slot number (-1 unknown)" ::= { svrPhysicalDeviceEntry 23 } svrPhysicalDeviceDisplayName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Device display name" ::= { svrPhysicalDeviceEntry 24 } svrPhysicalDevicePowerStatus OBJECT-TYPE SYNTAX INTEGER { active(1), stopped(2), transition(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Device power status: active(1): device is active stopped(2): device is powered down transition(3): device changes its power status" ::= { svrPhysicalDeviceEntry 25 } -- ********************************************************************************************** -- -- GROUP svrLogicalDriveInfo -- DESCRIPTION "This group contains information about logical RAID drives" -- -- svrLogicalDriveInfo group: 1.3.6.1.4.1.231.2.49.1.6 -- -- ********************************************************************************************** svrLogicalDriveInfo OBJECT IDENTIFIER ::= { svrObjects 6 } svrNumberLogicalDrives OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of available logical drives (number of entries in svrLogicalDriveTable and svrLogicalDriveContentsTable)" ::= { svrLogicalDriveInfo 1 } -- ---------------------------------------------------------------------------------------------- -- -- TABLE svrLogicalDriveTable -- STATUS mandatory -- DESCRIPTION "Table containing logical drives (system drives)" -- -- svrLogicalDriveTable: 1.3.6.1.4.1.231.2.49.1.6.2 -- -- ---------------------------------------------------------------------------------------------- svrLogicalDriveTable OBJECT-TYPE SYNTAX SEQUENCE OF SvrLogicalDriveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing logical drives (system drives)" ::= { svrLogicalDriveInfo 2 } svrLogicalDriveEntry OBJECT-TYPE SYNTAX SvrLogicalDriveEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { svrLogicalDriveCtrlNr, svrLogicalDriveNr } ::= { svrLogicalDriveTable 1 } SvrLogicalDriveEntry ::= SEQUENCE { svrLogicalDriveCtrlNr Index, svrLogicalDriveNr Index, svrLogicalDriveArraySize INTEGER, svrLogicalDriveTotalSize INTEGER, svrLogicalDriveRaidLevel INTEGER, svrLogicalDriveRaidLevelStr DisplayString, svrLogicalDriveStripeSize INTEGER, svrLogicalDriveWriteMode INTEGER, svrLogicalDriveProgress Gauge, svrLogicalDriveStatus INTEGER, svrLogicalDriveName DisplayString, svrLogicalDriveArraySizeMB INTEGER, svrLogicalDriveTotalSizeMB INTEGER, svrLogicalDriveOSDeviceName DisplayString, svrLogicalDriveReadMode INTEGER, svrLogicalDriveCacheMode INTEGER, svrLogicalDriveDiskCacheMode INTEGER, svrLogicalDriveInitStatus INTEGER, svrLogicalDriveStatusEx INTEGER, svrLogicalDriveDisplayName DisplayString } svrLogicalDriveCtrlNr OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Controller number (same as index in svrCtrlTable); if 0, logical drive is not attached to any controller" ::= { svrLogicalDriveEntry 1 } svrLogicalDriveNr OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Unique logical drive number on the specified controller (index; starts with 1)" ::= { svrLogicalDriveEntry 2 } svrLogicalDriveArraySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size (GBytes) of the logical drive (usable space)" ::= { svrLogicalDriveEntry 3 } svrLogicalDriveTotalSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size (GBytes) of the logical drive (physical disk space, size of all drives)" ::= { svrLogicalDriveEntry 4 } svrLogicalDriveRaidLevel OBJECT-TYPE SYNTAX INTEGER { unknown(1), raid0(2), raid01(3), raid1(4), raid1e(5), raid10(6), raid3(7), raid4(8), raid5(9), raid50(10), raid5e(11), raid5ee(12), raid6(13), concat(14), single(15), raid60(16), raid1e0(17), raid0CC(18), raid1CC(19), raid1ECC(20), raid5CC(21), raid00(22) } ACCESS read-only STATUS mandatory DESCRIPTION "RAID level" ::= { svrLogicalDriveEntry 5 } svrLogicalDriveRaidLevelStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "RAID level (as string, e.g. 'Single', 'Mirror'...)" ::= { svrLogicalDriveEntry 6 } svrLogicalDriveStripeSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "RAID stripe size (in bytes) of the logical drive" ::= { svrLogicalDriveEntry 7 } svrLogicalDriveWriteMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), writeBack(2), writeThrough(3), adaptive(4), writeBackBadBBU(5), readOnly(6), readWrite(7), alwaysReadWrite(8), notAvailable(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive write mode: writeBack(2): cached writeThrough(3): not cached adaptive(4): cached if BBU is working properly, else un-cached writeBackBadBBU(5): remain cached even if BBU fails readOnly(6): cache read operations only readWrite(7): cache read and write operations alwaysReadWrite(8): always cache read and write operations" ::= { svrLogicalDriveEntry 8 } svrLogicalDriveProgress OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive task progress (in percent 0..100) of a rebuild / verify / initialize task. This value is only valid if the drive is performing a longer task like rebuild, verify (consistency check) or initialization and is 100 if no task is in progress or task is finished." ::= { svrLogicalDriveEntry 9 } svrLogicalDriveStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), online(2), degraded(3), offline(4), rebuilding(5), verifying(6), initializing(7), morphing(8), partialDegraded(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the logical drive (deprecated): online(2): drive is OK, all disks working properly degraded(3): one disk in this array failed, redundancy lost offline(4): too many disks in this array failed, drive no longer available rebuilding(5): drive is currently rebuilding (new disk added) verifying(6): drive is currently executing a consistency check initializing(7): drive was just created and is currently being initialized morphing(8): drive is currently being modified (online RAID extension) partialDegraded(9): one disk in this array failed, reduced redundancy still available" ::= { svrLogicalDriveEntry 10 } svrLogicalDriveName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive name" ::= { svrLogicalDriveEntry 11 } svrLogicalDriveArraySizeMB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size (MBytes) of the logical drive (usable space)" ::= { svrLogicalDriveEntry 12 } svrLogicalDriveTotalSizeMB OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Size (MBytes) of the logical drive (physical disk space, size of all drives)" ::= { svrLogicalDriveEntry 13 } svrLogicalDriveOSDeviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Operating system device name" ::= { svrLogicalDriveEntry 14 } svrLogicalDriveReadMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), readAhead(2), noReadAhead(3), adaptive(4), notAvailable(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive read mode" ::= { svrLogicalDriveEntry 15 } svrLogicalDriveCacheMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), cached(2), direct(3), notAvailable(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive cache mode" ::= { svrLogicalDriveEntry 16 } svrLogicalDriveDiskCacheMode OBJECT-TYPE SYNTAX INTEGER { unknown(1), enabled(2), disabled(3), unchanged(4), notAvailable(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive disk cache mode" ::= { svrLogicalDriveEntry 17 } svrLogicalDriveInitStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), initialized(2), notInitialized(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive initialization status" ::= { svrLogicalDriveEntry 18 } svrLogicalDriveStatusEx OBJECT-TYPE SYNTAX INTEGER { unknown(1), operational(2), partiallyDegraded(3), degraded(4), failed(5), rebuilding(6), checking(7), mdcing(8), initializing(9), backgroundInitializing(10), migrating(11), copying(12), offline(13), spareInUse(14), erasing(15) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the logical drive: operational(2): drive is OK, all disks working properly partiallyDegraded(3): one disk in this array failed, reduced redundancy still available degraded(4): one disk in this array failed, redundancy lost failed(5): too many disks in this array failed, drive no longer available rebuilding(6): drive is currently rebuilding checking(7): drive is currently executing a consistency check mdcing(8): drive is currently executing a consistency check and fixes inconsistencies initializing(9): drive is currently being initialized backgroundInitializing(10): drive is currently being initialized in background migrating(11): drive is currently being modified (online RAID extension) copying(12): drive is currently executing a copyback or redundant copy operation offline(13): drive is temporarily not operational spareInUse(14): drive is using a hot spare erasing(15): drive is being erased" ::= { svrLogicalDriveEntry 19 } svrLogicalDriveDisplayName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive display name" ::= { svrLogicalDriveEntry 20 } -- ---------------------------------------------------------------------------------------------- -- -- TABLE svrLogicalDriveContentsTable -- STATUS mandatory -- DESCRIPTION "Table containing the devices belonging to a logical drive -- (logical to device mapping); -- the same device can be member of more than one logical drive." -- -- svrLogicalDriveContentsTable: 1.3.6.1.4.1.231.2.49.1.6.3 -- -- ---------------------------------------------------------------------------------------------- svrLogicalDriveContentsTable OBJECT-TYPE SYNTAX SEQUENCE OF SvrLogicalDriveContentsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing the devices belonging to a logical drive (logical to device mapping); the same device can be member of more than one logical drive." ::= { svrLogicalDriveInfo 3 } svrLogicalDriveContentsEntry OBJECT-TYPE SYNTAX SvrLogicalDriveContentsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { svrLogicalDriveContentsCtrlNr, svrLogicalDriveContentsLogicalDriveNr, svrLogicalDriveContentsNr, svrLogicalDriveContentsIdx } ::= { svrLogicalDriveContentsTable 1 } SvrLogicalDriveContentsEntry ::= SEQUENCE { svrLogicalDriveContentsCtrlNr Index, svrLogicalDriveContentsLogicalDriveNr Index, svrLogicalDriveContentsNr Index, svrLogicalDriveContentsChannel INTEGER, svrLogicalDriveContentsTarget INTEGER, svrLogicalDriveContentsLUN INTEGER, svrLogicalDriveContentsIdx Index, svrLogicalDriveContentsSpanNr INTEGER } svrLogicalDriveContentsCtrlNr OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Controller number (same as index in svrCtrlTable)" ::= { svrLogicalDriveContentsEntry 1 } svrLogicalDriveContentsLogicalDriveNr OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive number (same as index in svrLogicalDriveTable)" ::= { svrLogicalDriveContentsEntry 2 } svrLogicalDriveContentsNr OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Device index (index; starts with 1 for each logical drive)" ::= { svrLogicalDriveContentsEntry 3 } svrLogicalDriveContentsChannel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device channel number (same as index in svrPhysicalDeviceTable)" ::= { svrLogicalDriveContentsEntry 4 } svrLogicalDriveContentsTarget OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device target number (same as index in svrPhysicalDeviceTable)" ::= { svrLogicalDriveContentsEntry 5 } svrLogicalDriveContentsLUN OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Device logical unit number (same as index in svrPhysicalDeviceTable)" ::= { svrLogicalDriveContentsEntry 6 } svrLogicalDriveContentsIdx OBJECT-TYPE SYNTAX Index ACCESS read-only STATUS mandatory DESCRIPTION "Device SVRAID object index (same as Idx in svrPhysicalDeviceTable)" ::= { svrLogicalDriveContentsEntry 7 } svrLogicalDriveContentsSpanNr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Logical drive span number (starts with 1)" ::= { svrLogicalDriveContentsEntry 8 } -- ********************************************************************************************** -- -- GROUP svrNotificationsInfo -- DESCRIPTION "This group defines the trap parameter variables. They are not accessible directly, -- but sent together with traps." -- -- svrNotificationsInfo group: 1.3.6.1.4.1.231.2.49.2.1 -- -- ********************************************************************************************** svrNotificationsInfo OBJECT IDENTIFIER ::= { svrNotifications 1 } svrTrapInfoServerName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Name of the server the trap comes from" ::= { svrNotificationsInfo 1 } svrTrapInfoTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time when the trap occurred (in seconds since 01/01/1970 00:00h)" ::= { svrNotificationsInfo 2 } svrTrapInfoPlaceHolder1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Text to replace %? in trap descriptions" ::= { svrNotificationsInfo 3 } svrTrapInfoPlaceHolder2 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Text to replace %? in trap descriptions" ::= { svrNotificationsInfo 4 } svrTrapInfoPlaceHolder3 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Text to replace %? in trap descriptions" ::= { svrNotificationsInfo 5 } svrTrapInfoPlaceHolder4 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Text to replace %? in trap descriptions" ::= { svrNotificationsInfo 6 } svrTrapInfoPlaceHolder5 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Text to replace %? in trap descriptions" ::= { svrNotificationsInfo 7 } svrTrapInfoPlaceHolder6 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Text to replace %? in trap descriptions" ::= { svrNotificationsInfo 8 } -- ********************************************************************************************** -- -- GROUP svrNotificationsTraps -- DESCRIPTION "This group defines the traps." -- -- Trap enterprise: svrNotifications (1.3.6.1.4.1.231.2.49.2) -- -- ********************************************************************************************** -- EVT_UNDEFINED svrTrapUndefinedEvent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Undefined event." --#TYPE "Undefined event" --#SUMMARY "Undefined event (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "If there are errors directly before or after this event, perform the proper recovery action for that error." --#STATE OPERATIONAL ::= 1 -- EVT_CONNECTED svrTrapConnectedEvent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Connection to ServerView RAID Manager established." --#TYPE "Connection to ServerView RAID Manager established" --#SUMMARY "Connection to ServerView RAID Manager established (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 2 -- EVT_DISCONNECTED svrTrapDisconnectedEvent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disconnected from ServerView RAID Manager." --#TYPE "Disconnected from ServerView RAID Manager" --#SUMMARY "Disconnected from ServerView RAID Manager (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE NONOPERATIONAL ::= 3 -- EVT_UNEXPECTED_DISCONNECT svrTrapUnexpectedDisconnectEvent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unexpected disconnect from ServerView RAID Manager." --#TYPE "Unexpected disconnect from ServerView RAID Manager" --#SUMMARY "Unexpected disconnect from ServerView RAID Manager (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "If problem persists after reboot, call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 4 -- EVT_TEST_TRAP svrTrapTestEvent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Test event." --#TYPE "Test event" --#SUMMARY "Test event (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 5 -- EVT_UNKNOWN svrTrapUnknownEvent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unknown event." --#TYPE "Unknown event" --#SUMMARY "Unknown event (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "If there are errors directly before or after this event, perform the proper recovery action for that error." --#STATE OPERATIONAL ::= 10000 -- EVT_INTERNAL svrTrapInternalEvent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal event." --#TYPE "Internal event" --#SUMMARY "Internal event (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10001 -- EVT_WRITEACCESS_REVOKED svrTrapWriteAccessRevoked TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write access of the ServerView RAID Manager revoked." --#TYPE "Write access of the ServerView RAID Manager revoked" --#SUMMARY "Write access of the ServerView RAID Manager revoked by user %s (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10002 -- EVT_BATTERY_TEMPERATURE_OUT_OF_RANGE svrTrapBatteryTempOutOfRange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU temperature out of range." --#TYPE "BBU temperature out of range" --#SUMMARY "Adapter %s: BBU temperature out of range (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check installation of all air flow channels, closed housing, and unblocked louvers. 2) Check environmental temperature. 3) Check version of RAID controller/iRMC firmware, and BIOS." --#STATE OPERATIONAL ::= 10003 -- EVT_BATTERY_TEMPERATURE_UNSTABLE svrTrapBatteryTempUnstable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU temperature unstable." --#TYPE "BBU temperature unstable" --#SUMMARY "Adapter %s: BBU temperature unstable (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check version of RAID controller/iRMC firmware, and BIOS. 2) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10004 -- EVT_BATTERY_TEMPERATURE_HIGH svrTrapBatteryTempAboveTheshold TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU temperature above threshold." --#TYPE "BBU temperature above threshold" --#SUMMARY "Adapter %s: BBU temperature above threshold (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check installation of all air flow channels, closed housing, and unblocked louvers. 2) Check environmental temperature. 3) Check version of RAID controller/iRMC firmware, and BIOS." --#STATE OPERATIONAL ::= 10005 -- EVT_BATTERY_VOLTAGE_OUT_OF_RANGE svrTrapBatteryVoltageOutOfRange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU voltage out of range." --#TYPE "BBU voltage out of range" --#SUMMARY "Adapter %s: BBU voltage out of range (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check connection between BBU data/power cable and RAID controller. 2) Check version of RAID controller/iRMC firmware, and BIOS. 3) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10006 -- EVT_BATTERY_VOLTAGE_UNSTABLE svrTrapBatteryVoltageUnstable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU voltage unstable." --#TYPE "BBU voltage unstable" --#SUMMARY "Adapter %s: BBU voltage unstable (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check connection between BBU data/power cable and RAID controller. 2) Check version of RAID controller/iRMC firmware, and BIOS. 3) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10007 -- EVT_BATTERY_VOLTAGE_LOW svrTrapBatteryVoltageLow TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU voltage below threshold." --#TYPE "BBU voltage below threshold" --#SUMMARY "Adapter %s: BBU voltage below threshold (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check connection between BBU data/power cable and RAID controller. 2) Check version of RAID controller/iRMC firmware, and BIOS. 3) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10008 -- EVT_BATTERY_COMMUNICATION_ERROR svrTrapBatteryCommunicationError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU communication error." --#TYPE "BBU communication error" --#SUMMARY "Adapter %s: BBU communication error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check connection between BBU data/power cable and RAID controller. 2) Check version of RAID controller/iRMC firmware, and BIOS. 3) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10009 -- EVT_BATTERY_RECONDITION_STARTED svrTrapBatteryReconditionStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU reconditioning started." --#TYPE "BBU reconditioning started" --#SUMMARY "Adapter %s: BBU reconditioning started (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10010 -- EVT_BATTERY_NORMAL svrTrapBatteryStatusNormal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU status becomes normal." --#TYPE "BBU status becomes normal" --#SUMMARY "Adapter %s: BBU status becomes normal (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10011 -- EVT_BATTERY_GOOD svrTrapBatteryGood TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU good." --#TYPE "BBU good" --#SUMMARY "Adapter %s: BBU good (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10012 -- EVT_BATTERY_FAILED svrTrapBatteryFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU failed." --#TYPE "BBU failed" --#SUMMARY "Adapter %s: BBU failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Note: Only informational during recalibration process. 1) Check connection between BBU data/power cable and RAID controller. 2) Check version of RAID controller/iRMC firmware, and BIOS. 3) If problem persists replace BBU." --#STATE NONOPERATIONAL ::= 10013 -- EVT_BATTERY_FAST_CHARGE_FAILED svrTrapBatteryFastChargingFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU fast charging failed." --#TYPE "BBU fast charging failed" --#SUMMARY "Adapter %s: BBU fast charging failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Note: Do not interrupt the charging process by reboots or shutdowns. 1) Check version of RAID controller/iRMC firmware, and BIOS. 2) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10014 -- EVT_BATTERY_CHARGE_COUNT_EXCEEDED svrTrapBatteryChargeCountExceeded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU charge count exceeded." --#TYPE "BBU charge count exceeded" --#SUMMARY "Adapter %s: BBU charge count exceeded (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Initiate manual recalibration process (e.g. via ServerView RAID Manager). Note: Do not interrupt the charging process by reboots or shutdowns. 2) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10015 -- EVT_BATTERY_NEEDS_RECONDITION svrTrapBatteryNeedsRecondition TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU needs reconditioning." --#TYPE "BBU needs reconditioning" --#SUMMARY "Adapter %s: BBU needs reconditioning (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: By default BBU recalibration is automatically initiated every 30 days. 1) If scheduled BBU recalibration is disabled initiate manual recalibration process (e.g. via ServerView RAID Manager)." --#STATE OPERATIONAL ::= 10016 -- EVT_SCSI_SENSE_DATA svrTrapSCSISenseAvailable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SCSI sense data available." --#TYPE "SCSI sense data available" --#SUMMARY "Adapter %s: SCSI sense data on disk (%s) available: %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10017 -- EVT_ASYNCHRONOUS_COMMAND_COMPLETED svrTrapAsyncCommandCompleted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Asynchronous command finished." --#TYPE "Asynchronous command finished" --#SUMMARY "Adapter %s: Asynchronous command finished (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10018 -- EVT_ADAPTER_PAUSED svrTrapAdapterPaused TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter suspended." --#TYPE "Adapter suspended" --#SUMMARY "Adapter %s suspended (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE NONOPERATIONAL ::= 10019 -- EVT_ADAPTER_CONTINUED svrTrapAdapterContinued TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter resumed." --#TYPE "Adapter resumed" --#SUMMARY "Adapter %s resumed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10020 -- EVT_DISK_ONLINE svrTrapPDMarkedOnline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk marked online." --#TYPE "Disk marked online" --#SUMMARY "Adapter %s: Disk (%s) marked online (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10021 -- EVT_DISK_OFFLINE svrTrapPDMarkedOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk marked offline." --#TYPE "Disk marked offline" --#SUMMARY "Adapter %s: Disk (%s) marked offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Note: Only informational if affected disk was manually set offline otherwise: 1) If offline disk is member of an array initiate a rebuild to the offline disk. 2) If problem persists replace affected disk." --#STATE NONOPERATIONAL ::= 10022 -- EVT_DISK_TIME_OUT svrTrapPDTimedOut TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk timed out." --#TYPE "Disk timed out" --#SUMMARY "Adapter %s: Disk (%s) timed out (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Note: In general additional error messages should occur. If there are no other actions defined call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10023 -- EVT_GLOBAL_HOTSPARE_CREATED svrTrapPDCreatedGlobalHotspare TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Global hot spare created on disk." --#TYPE "Global hot spare created on disk" --#SUMMARY "Adapter %s: Global hot spare created on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10024 -- EVT_GLOBAL_HOTSPARE_DELETED svrTrapPDDeletedGlobalHotspare TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Global hot spare deleted on disk." --#TYPE "Global hot spare deleted on disk" --#SUMMARY "Adapter %s: Global hot spare deleted on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10025 -- EVT_DEDICATED_HOTSPARE_CREATED svrTrapPDCreatedDedicatedHotspare TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Dedicated hot spare created on disk." --#TYPE "Dedicated hot spare created on disk" --#SUMMARY "Adapter %s: Dedicated hot spare created on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10026 -- EVT_DEDICATED_HOTSPARE_DELETED svrTrapPDDeletedDedicatedHotspare TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Dedicated hot spare deleted on disk." --#TYPE "Dedicated hot spare deleted on disk" --#SUMMARY "Adapter %s: Dedicated hot spare deleted on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10027 -- EVT_DISK_AVAILABLE svrTrapPDMarkedAvailable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk marked available." --#TYPE "Disk marked available" --#SUMMARY "Adapter %s: Disk (%s) marked available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10028 -- EVT_DISK_REBUILDING svrTrapPDRebuildStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild on disk started." --#TYPE "Rebuild on disk started" --#SUMMARY "Adapter %s: Rebuild on disk (%s) started (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10029 -- EVT_DISK_REBUILD_FAILED svrTrapPDRebuildFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild on disk failed." --#TYPE "Rebuild on disk failed" --#SUMMARY "Adapter %s: Rebuild on disk (%s) failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Manually initiate a second rebuild (e.g. via ServerView RAID Manager). 2) If problem persists replace affected disk." --#STATE DEGRADED ::= 10030 -- EVT_DISK_BAD_BLOCK svrTrapPDBadBlockDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block on disk detected." --#TYPE "Bad block on disk detected" --#SUMMARY "Adapter %s: Bad block on disk (%s) LBA %s detected (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE DEGRADED ::= 10031 -- EVT_PNPADD svrTrapNewPDDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "New disk detected." --#TYPE "New disk detected" --#SUMMARY "Adapter %s: New disk (%s) detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10032 -- EVT_PNPREMOVE svrTrapPDRemoved TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk removed." --#TYPE "Disk removed" --#SUMMARY "Adapter %s: Disk (%s) removed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Only informational if affected disk has been removed otherwise: 1) Unplug affected disk, wait 30 seconds, reinsert it. 2) Replace affected disk. 3) Replace affected backplane or the data cable." --#STATE OPERATIONAL ::= 10033 -- EVT_BAD_SECTOR_CLEARED svrTrapPDBadSectorLogEntryCleared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad sector log entry on disk cleared." --#TYPE "Bad sector log entry on disk cleared" --#SUMMARY "Adapter %s: Bad sector log entry on disk (%s) cleared (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10034 -- EVT_BAD_SECTOR_UPDATED svrTrapPDBadSectorLogUpdated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad sector log on disk updated." --#TYPE "Bad sector log on disk updated" --#SUMMARY "Adapter %s: Bad sector log on disk (%s) updated (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10035 -- EVT_BAD_SECTOR svrTrapPDBadSectorDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad sector on disk detected." --#TYPE "Bad sector on disk detected" --#SUMMARY "Adapter %s: Bad sector on disk (%s) detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE DEGRADED ::= 10036 -- EVT_COD_ERROR svrTrapPDCODIOError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "COD I/O error on disk." --#TYPE "COD I/O error on disk" --#SUMMARY "Adapter %s: COD I/O error on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Manually initiate a rebuild (e.g. via ServerView RAID Manager) of affected disk. 2) If problem persists replace affected disk." --#STATE OPERATIONAL ::= 10037 -- EVT_TASK_ERROR svrTrapPDErrorDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Error on disk detected." --#TYPE "Error on disk detected" --#SUMMARY "Adapter %s: Error on disk (%s) detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10038 -- EVT_RESET_CHANNEL svrTrapChannelReset TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Channel was reset." --#TYPE "Channel was reset" --#SUMMARY "Adapter %s: Channel %s was reset (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10039 -- EVT_IO_RETRY svrTrapPDRetryIO TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Retry I/O on disk." --#TYPE "Retry I/O on disk" --#SUMMARY "Adapter %s: Retry I/O on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "If the problem occurs repeatedly replace affected disk." --#STATE OPERATIONAL ::= 10040 -- EVT_ECC_ERROR svrTrapPDECCError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "ECC error on disk." --#TYPE "ECC error on disk" --#SUMMARY "Adapter %s: ECC error on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "If the problem occurs repeatedly replace affected disk." --#STATE OPERATIONAL ::= 10041 -- EVT_WRITE_MODE_SWITCH svrTrapAdapterWriteModeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write mode changed." --#TYPE "Write mode changed" --#SUMMARY "Adapter %s: Write modes changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10042 -- EVT_MEDIA_ERROR svrTrapPDMediaError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Media error on disk." --#TYPE "Media error on disk" --#SUMMARY "Adapter %s: Media error on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10043 -- EVT_SMART_WARNING svrTrapPDSMARTWarning TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SMART warning on disk." --#TYPE "SMART warning on disk" --#SUMMARY "Adapter %s: SMART warning on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Disk reports a prefailure. The affected disk might fail soon. 1) Replace the disk during next maintenance." --#STATE OPERATIONAL ::= 10044 -- EVT_SMART_ERROR svrTrapPDSMARTError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SMART error on disk." --#TYPE "SMART error on disk" --#SUMMARY "Adapter %s: SMART error on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10045 -- EVT_SWAP_BAD_SWAP svrTrapEnclosureBadPDInserted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad disk inserted in enclosure." --#TYPE "Bad disk inserted in enclosure" --#SUMMARY "Adapter %s: Bad disk inserted in enclosure %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10046 -- EVT_SWAP_POWER_DOWN svrTrapEnclosurePoweredDown TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure powered down." --#TYPE "Enclosure powered down" --#SUMMARY "Adapter %s: Enclosure %s powered down (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "If this error message is not a result of a planned power off of the external storage subsystem: 1) Check the power cable(s). 2) Check the mains voltage. 3) Replace affected power supply(s)." --#STATE NONOPERATIONAL ::= 10047 -- EVT_SWAP_POWER_UP svrTrapEnclosurePoweredUp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure powered up." --#TYPE "Enclosure powered up" --#SUMMARY "Adapter %s: Enclosure %s powered up (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10048 -- EVT_FAN_FAILED svrTrapEnclosureFanFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Fan in enclosure failed." --#TYPE "Fan in enclosure failed" --#SUMMARY "Adapter %s: Fan %s in enclosure %s failed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected fan within the external storage subsystem." --#STATE OPERATIONAL ::= 10049 -- EVT_TEMPERATURE_SENSOR_ALERT svrTrapEnclosureTempSensAboveThreshold TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Temperature sensor in enclosure above threshold." --#TYPE "Temperature sensor in enclosure above threshold" --#SUMMARY "Adapter %s: Temperature sensor %s in enclosure %s above threshold (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check installation of all air flow channels, closed housing, and unblocked louvers. 2) Check environmental temperature." --#STATE OPERATIONAL ::= 10050 -- EVT_POWER_SUPPLY_FAILED svrTrapEnclosurePowerSupplyFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power supply in enclosure failed." --#TYPE "Power supply in enclosure failed" --#SUMMARY "Adapter %s: Power supply %s in enclosure %s failed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Check the power cable. 2) Check the mains voltage. 3) Replace affected power supply." --#STATE OPERATIONAL ::= 10051 -- EVT_POWER_SUPPLY_FAILED_3 svrTrapPD33VPowerFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "3.3V power failed for disk." --#TYPE "3.3V power failed for disk" --#SUMMARY "Adapter %s: 3.3V power failed for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Check whether all cables are correctly connected to the disk backplane connectors. 2) Replace affected disk." --#STATE OPERATIONAL ::= 10052 -- EVT_POWER_SUPPLY_FAILED_5 svrTrapPD50VPowerFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "5.0V power failed for disk." --#TYPE "5.0V power failed for disk" --#SUMMARY "Adapter %s: 5.0V power failed for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Check whether all cables are correctly connected to the disk backplane connectors. 2) Replace affected disk." --#STATE OPERATIONAL ::= 10053 -- EVT_POWER_SUPPLY_FAILED_12 svrTrapPD12VPowerFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "12V power failed for disk." --#TYPE "12V power failed for disk" --#SUMMARY "Adapter %s: 12V power failed for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Check whether all cables are correctly connected to the disk backplane connectors. 2) Replace affected disk." --#STATE NONOPERATIONAL ::= 10054 -- EVT_REBUILD_STARTED svrTrapLDRebuildStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild started on logical drive." --#TYPE "Rebuild started on logical drive" --#SUMMARY "Adapter %s: Rebuild started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10055 -- EVT_REBUILD_FINISHED svrTrapLDRebuildFinished TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild finished on logical drive." --#TYPE "Rebuild finished on logical drive" --#SUMMARY "Adapter %s: Rebuild finished on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10056 -- EVT_REBUILD_FAILED svrTrapLDRebuildFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild failed on logical drive." --#TYPE "Rebuild failed on logical drive" --#SUMMARY "Adapter %s: Rebuild failed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Manually initiate a second rebuild (e.g. via ServerView RAID Manager)." --#STATE DEGRADED ::= 10057 -- EVT_REBUILD_CANCELED svrTrapLDRebuildAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild aborted on logical drive." --#TYPE "Rebuild aborted on logical drive" --#SUMMARY "Adapter %s: Rebuild aborted on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Rebuild was probably aborted by user. Attention: The affected RAID array is still degraded. 1) The rebuild should be started again as soon as possible." --#STATE DEGRADED ::= 10058 -- EVT_REBUILD_PAUSED svrTrapLDRebuildPaused TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild suspended on logical drive." --#TYPE "Rebuild suspended on logical drive" --#SUMMARY "Adapter %s: Rebuild suspended on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10059 -- EVT_CHECK_STARTED svrTrapLDConCheckStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check started on logical drive." --#TYPE "Consistency check started on logical drive" --#SUMMARY "Adapter %s: Consistency check started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10060 -- EVT_CHECK_FINISHED svrTrapLDConCheckFinished TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check finished on logical drive." --#TYPE "Consistency check finished on logical drive" --#SUMMARY "Adapter %s: Consistency check finished on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10061 -- EVT_CHECK_FAILED svrTrapLDConCheckFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check failed on logical drive." --#TYPE "Consistency check failed on logical drive" --#SUMMARY "Adapter %s: Consistency check failed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Failure happens only if a disk out of the logical drive failed. 1) Check state of logical drive. 2) If logical drive is not operational, check state of affected disk. 3) Check for additional error messages for affected disk." --#STATE OPERATIONAL ::= 10062 -- EVT_CHECK_CANCELED svrTrapLDConCheckAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check aborted on logical drive." --#TYPE "Consistency check aborted on logical drive" --#SUMMARY "Adapter %s: Consistency check aborted on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Consistency check was probably aborted by user. 1) The consistency check should be started again as soon as possible." --#STATE OPERATIONAL ::= 10063 -- EVT_CHECK_PAUSED svrTrapLDConCheckPaused TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check suspended on logical drive." --#TYPE "Consistency check suspended on logical drive" --#SUMMARY "Adapter %s: Consistency check suspended on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10064 -- EVT_CHECK_STARTED_UNINITIALIZED svrTrapLDUninitialisedConCheckStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check started on uninitialized logical drive." --#TYPE "Consistency check started on uninitialized logical drive" --#SUMMARY "Adapter %s: Consistency check started on uninitialized logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10065 -- EVT_CHECK_ERROR svrTrapLDConCheckFinishedWithErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check finished with errors on logical drive." --#TYPE "Consistency check finished with errors on logical drive" --#SUMMARY "Adapter %s: Consistency check finished with errors on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Manually initiate second consistency check (MDC). 2) If problem persists backup data from affected logical drive. 3) Delete and recreate affected logical drive. 4) Restore data." --#STATE OPERATIONAL ::= 10066 -- EVT_INCONSISTENT_LBA svrTrapLDInconsistencyDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Inconsistency detected on logical drive." --#TYPE "Inconsistency detected on logical drive" --#SUMMARY "Adapter %s: Inconsistency detected on logical drive %s at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check if logical drive is initialized. If initialized check the following: 1) Backup your data. 2) Start a consistency check with fix. 3) Compare backup data with data on logical drive. 4) If different (data lost), restore last good data." --#STATE OPERATIONAL ::= 10067 -- EVT_MIGRATION_STARTED svrTrapLDMigrationStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Migration started on logical drive." --#TYPE "Migration started on logical drive" --#SUMMARY "Adapter %s: Migration started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10068 -- EVT_MIGRATION_FINISHED svrTrapLDMigrationFinished TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Migration finished on logical drive." --#TYPE "Migration finished on logical drive" --#SUMMARY "Adapter %s: Migration finished on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10069 -- EVT_MIGRATION_FAILED svrTrapLDMigrationFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Migration failed on logical drive." --#TYPE "Migration failed on logical drive" --#SUMMARY "Adapter %s: Migration failed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Note: The logical drive is failed (multi dead). 1) Replace broken drives. 2) Create new configuration and restore last good data." --#STATE OPERATIONAL ::= 10070 -- EVT_MIGRATION_ABORTED svrTrapLDMigrationAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Migration aborted on logical drive." --#TYPE "Migration aborted on logical drive" --#SUMMARY "Adapter %s: Migration aborted on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Migration was probably aborted by user. For information only." --#STATE OPERATIONAL ::= 10071 -- EVT_PATROL_READ_STARTED svrTrapAdapterPatrolReadStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read started." --#TYPE "Patrol Read started" --#SUMMARY "Adapter %s: Patrol Read started (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10072 -- EVT_PATROL_READ_FINISHED svrTrapAdapterPatrolReadCompleted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read finished." --#TYPE "Patrol Read finished" --#SUMMARY "Adapter %s: Patrol Read finished (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10073 -- EVT_PATROL_READ_CANCELED svrTrapAdapterPatrolReadAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read aborted." --#TYPE "Patrol Read aborted" --#SUMMARY "Adapter %s: Patrol Read aborted (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Patrol read was probably aborted by user. For information only." --#STATE OPERATIONAL ::= 10074 -- EVT_PATROL_READ_STOPPED svrTrapAdapterPatrolReadStopped TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read stopped." --#TYPE "Patrol Read stopped" --#SUMMARY "Adapter %s: Patrol Read stopped (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10075 -- EVT_PATROL_READ_PAUSED svrTrapAdapterPatrolReadPaused TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read suspended." --#TYPE "Patrol Read suspended" --#SUMMARY "Adapter %s: Patrol Read suspended (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10076 -- EVT_PATROL_READ_CONTINUED svrTrapAdapterPatrolReadContinued TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read resumed." --#TYPE "Patrol Read resumed" --#SUMMARY "Adapter %s: Patrol Read resumed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10077 -- EVT_LOGICALDRIVE_DEGRADED svrTrapLDDegraded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive degraded." --#TYPE "Logical drive degraded" --#SUMMARY "Adapter %s: Logical drive %s degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Manually initiate a rebuild of affected disk (e.g. via ServerView RAID Manager). 2) If problem persists replace affected disk." --#STATE DEGRADED ::= 10078 -- EVT_LOGICALDRIVE_FAILED svrTrapLDFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive failed." --#TYPE "Logical drive failed" --#SUMMARY "Adapter %s: Logical drive %s failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Note: Sometimes it is possible to recover without data loss. Further investigation is needed." --#STATE NONOPERATIONAL ::= 10079 -- EVT_LOGICALDRIVE_CREATED svrTrapLDCreated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive created." --#TYPE "Logical drive created" --#SUMMARY "Adapter %s: Logical drive %s created (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10080 -- EVT_LOGICALDRIVE_DELETED svrTrapLDDeleted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive deleted." --#TYPE "Logical drive deleted" --#SUMMARY "Adapter %s: Logical drive %s deleted (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10081 -- EVT_LOGICALDRIVE_OPERATIONAL svrTrapLDOperational TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive operational." --#TYPE "Logical drive operational" --#SUMMARY "Adapter %s: Logical drive %s operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10082 -- EVT_LOGICALDRIVE_DISKERROR svrTrapLDPDError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive error on disk." --#TYPE "Logical drive error on disk" --#SUMMARY "Adapter %s: Logical drive %s: Error on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10083 -- EVT_LOGICALDRIVE_BAD_BLOCK svrTrapLDBadBlockDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive bad block detected." --#TYPE "Logical drive bad block detected" --#SUMMARY "Adapter %s: Logical drive %s: Bad block at LBA %s detected (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Try to rewrite data. 2) If problem persists replace affected disk." --#STATE OPERATIONAL ::= 10084 -- EVT_INITIALIZATION_STARTED svrTrapLDInitStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization started on logical drive." --#TYPE "Initialization started on logical drive" --#SUMMARY "Adapter %s: Initialization started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10085 -- EVT_INITIALIZATION_FINISHED svrTrapLDInitFinished TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization finished on logical drive." --#TYPE "Initialization finished on logical drive" --#SUMMARY "Adapter %s: Initialization finished on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10086 -- EVT_BGI_STARTED svrTrapLDBackInitStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI started on logical drive." --#TYPE "BGI started on logical drive" --#SUMMARY "Adapter %s: BGI started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10087 -- EVT_BGI_FINISHED svrTrapLDBackInitFinished TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI finished on logical drive." --#TYPE "BGI finished on logical drive" --#SUMMARY "Adapter %s: BGI finished on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10088 -- EVT_BGI_CANCELED svrTrapLDBackInitCanceled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI canceled on logical drive." --#TYPE "BGI canceled on logical drive" --#SUMMARY "Adapter %s: BGI canceled on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Background initialization (BGI) resumes automatically after a certain period of time. For information only." --#STATE OPERATIONAL ::= 10089 -- EVT_INITIALIZATION_CANCELED svrTrapLDInitCanceled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization canceled on logical drive." --#TYPE "Initialization canceled on logical drive" --#SUMMARY "Adapter %s: Initialization canceled on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10090 -- EVT_DRIVELETTER_CHANGED svrTrapLDDriveLetterChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Drive letter changed for logical drive." --#TYPE "Drive letter changed for logical drive" --#SUMMARY "Adapter %s: Drive letter changed for logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10091 -- EVT_HOTSPARE_OPERATION_STARTED svrTrapLDHotspareOperationStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hot spare operation on logical drive started." --#TYPE "Hot spare operation on logical drive started" --#SUMMARY "Adapter %s: Hot spare operation on logical drive %s started (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10092 -- EVT_HOTSPARE_OPERATION_FAILED svrTrapLDHotspareOperationFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hot spare operation on logical drive failed." --#TYPE "Hot spare operation on logical drive failed" --#SUMMARY "Adapter %s: Hot spare operation on logical drive %s failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Unplug affected disk, wait 30 seconds, reinsert it. 2) Replace affected disk." --#STATE OPERATIONAL ::= 10093 -- EVT_TEMPORARY_OFFLINE svrTrapLDForcedFromFailedToDegraded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive forced from failed to degraded." --#TYPE "Logical drive forced from failed to degraded" --#SUMMARY "Adapter %s: Logical drive %s forced from failed to degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Temporary offline case. 2) Try to rebuild remaining defect drive." --#STATE DEGRADED ::= 10094 -- EVT_ALARM_ENABLED svrTrapAdapterAlarmEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Alarm enabled." --#TYPE "Alarm enabled" --#SUMMARY "Adapter %s: Alarm enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10095 -- EVT_ALARM_DISABLED svrTrapAdapterAlarmDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Alarm disabled." --#TYPE "Alarm disabled" --#SUMMARY "Adapter %s: Alarm disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10096 -- EVT_AUTO_CHECK_ENABLED svrTrapAdapterAutomaticCheckEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic inconsistency handling enabled." --#TYPE "Automatic inconsistency handling enabled" --#SUMMARY "Adapter %s: Automatic inconsistency handling enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10097 -- EVT_AUTO_CHECK_DISABLED svrTrapAdapterAutomaticCheckDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic inconsistency handling disabled." --#TYPE "Automatic inconsistency handling disabled" --#SUMMARY "Adapter %s: Automatic inconsistency handling disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10098 -- EVT_CHECK_INTERVAL_CHANGED svrTrapAdapterCheckIntervalChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic inconsistency handling Interval changed." --#TYPE "Automatic inconsistency handling Interval changed" --#SUMMARY "Adapter %s: Inconsistency handling interval changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10099 -- EVT_REBUILD_RATE_CHANGED svrTrapAdapterRebuildRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild rate changed." --#TYPE "Rebuild rate changed" --#SUMMARY "Adapter %s: Rebuild rate changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10100 -- EVT_PATROLREAD_DISABLED svrTrapAdapterPatrolReadDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read disabled." --#TYPE "Patrol Read disabled" --#SUMMARY "Adapter %s: Patrol Read disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10101 -- EVT_PATROLREAD_AUTO svrTrapAdapterPatrolReadAutomatic TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read set to automatic." --#TYPE "Patrol Read set to automatic" --#SUMMARY "Adapter %s: Patrol Read set to automatic (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10102 -- EVT_PATROLREAD_MANUAL svrTrapAdapterPatrolReadManual TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read set to manual." --#TYPE "Patrol Read set to manual" --#SUMMARY "Adapter %s: Patrol Read set to manual (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10103 -- EVT_PATROLREAD_DELAY_CHANGED svrTrapAdapterPatrolReadDelayChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read delay changed." --#TYPE "Patrol Read delay changed" --#SUMMARY "Adapter %s: Patrol Read delay changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10104 -- EVT_NORMAL_INITIALIZATION svrTrapAdapterInitNormal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization set to normal." --#TYPE "Initialization set to normal" --#SUMMARY "Adapter %s: Initialization set to normal (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10105 -- EVT_FAST_INITIALIZATION svrTrapAdapterInitFast TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization set to fast." --#TYPE "Initialization set to fast" --#SUMMARY "Adapter %s: Initialization set to fast (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10106 -- EVT_INITIATOR_ID_CHANGED svrTrapAdapterInitiatorIDChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initiator ID changed." --#TYPE "Initiator ID changed" --#SUMMARY "Adapter %s: Initiator ID changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10107 -- EVT_AUTO_REBUILD_ENABLED svrTrapAdapterAutomaticeRebuildEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic rebuild enabled." --#TYPE "Automatic rebuild enabled" --#SUMMARY "Adapter %s: Automatic rebuild enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10108 -- EVT_AUTO_REBUILD_DISABLED svrTrapAdapterAutomaticeRebuildDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic rebuild disabled." --#TYPE "Automatic rebuild disabled" --#SUMMARY "Adapter %s: Automatic rebuild disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10109 -- EVT_NEW_DEVICE_AUTO svrTrapAdapterNewDeviceAutomatic TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "New device set to automatic." --#TYPE "New device set to automatic" --#SUMMARY "Adapter %s: New device set to automatic (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10110 -- EVT_NEW_DEVICE_CTRL_M svrTrapAdapterNewDeviceCTRLM TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "New device set to CTRL-M." --#TYPE "New device set to CTRL-M" --#SUMMARY "Adapter %s: New device set to CtrlM (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10111 -- EVT_MDC_RATE_CHANGED svrTrapAdapterMDCRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC rate changed." --#TYPE "MDC rate changed" --#SUMMARY "Adapter %s: MDC rate changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10112 -- EVT_MDC_RATE_CHANGED_EX svrTrapAdapterMDCRateChangedEx TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC rate changed." --#TYPE "MDC rate changed" --#SUMMARY "Adapter %s: MDC rate changed to %s percent (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10113 -- EVT_BIOS_ENABLED svrTrapAdapterBIOSEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BIOS enabled." --#TYPE "BIOS enabled" --#SUMMARY "Adapter %s: BIOS enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10114 -- EVT_BIOS_DISABLED svrTrapAdapterBIOSDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BIOS disabled." --#TYPE "BIOS disabled" --#SUMMARY "Adapter %s: BIOS disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10115 -- EVT_STOP_ON_ERROR_ENABLED svrTrapAdapterStopOnErrorEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BIOS stop on error enabled." --#TYPE "BIOS stop on error enabled" --#SUMMARY "Adapter %s: BIOS stop on error enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10116 -- EVT_STOP_ON_ERROR_DISABLED svrTrapAdapterStopOnErrorDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BIOS stop on error disabled." --#TYPE "BIOS stop on error disabled" --#SUMMARY "Adapter %s: BIOS stop on error disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10117 -- EVT_DISK_WRITE_CACHE_ENABLED svrTrapAdapterPDWriteCacheEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write cache on all disks enabled." --#TYPE "Write cache on all disks enabled" --#SUMMARY "Adapter %s: Write cache on all disks enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10118 -- EVT_DISK_WRITE_CACHE_DISABLED svrTrapAdapterPDWriteCacheDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write cache on all disks disabled." --#TYPE "Write cache on all disks disabled" --#SUMMARY "Adapter %s: Write cache on all disks disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10119 -- EVT_READAHEAD_ENABLED svrTrapAdapterPDReadAheadEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Read-ahead on all disks enabled." --#TYPE "Read-ahead on all disks enabled" --#SUMMARY "Adapter %s: Read-ahead on all disks enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10120 -- EVT_READAHEAD_DISABLED svrTrapAdapterPDReadAheadDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Read-ahead on all disks disabled." --#TYPE "Read-ahead on all disks disabled" --#SUMMARY "Adapter %s: Read-ahead on all disks disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10121 -- EVT_AUTO_RESUME_ENABLED svrTrapAdapterAutomaticResumeEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic resumption enabled." --#TYPE "Automatic resumption enabled" --#SUMMARY "Adapter %s: Automatic resumption enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10122 -- EVT_AUTO_RESUME_DISABLED svrTrapAdapterAutomaticResumeDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic resumption disabled." --#TYPE "Automatic resumption disabled" --#SUMMARY "Adapter %s: Automatic resumption disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10123 -- EVT_DEVICES_PER_SPIN_CHANGED svrTrapAdapterDevicesPerSpinChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Spinup drive count changed (after next reboot)." --#TYPE "Spinup drive count changed (after next reboot)" --#SUMMARY "Adapter %s: Spinup drive count changed (after next reboot) (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10124 -- EVT_DELAY_BETWEEN_SPINS_CHANGED svrTrapAdapterDelayBetweenSpinsChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Spinup delay changed (after next reboot)." --#TYPE "Spinup delay changed (after next reboot)" --#SUMMARY "Adapter %s: Spinup delay changed (after next reboot) (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10125 -- EVT_CHECK_RATE_CHANGED svrTrapAdapterConCheckRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check rate changed." --#TYPE "Consistency check rate changed" --#SUMMARY "Adapter %s: Consistency check rate changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10126 -- EVT_TEMPORARY_OFFLINE_ENABLED svrTrapAdapterTempOfflineEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Temporary offline enabled." --#TYPE "Temporary offline enabled" --#SUMMARY "Adapter %s: Temporary offline enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10127 -- EVT_TEMPORARY_OFFLINE_DISABLED svrTrapAdapterTempOfflineDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Temporary offline disabled." --#TYPE "Temporary offline disabled" --#SUMMARY "Adapter %s: Temporary offline disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10128 -- EVT_SMART_ENABLED svrTrapAdapterSMARTEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SMART enabled." --#TYPE "SMART enabled" --#SUMMARY "Adapter %s: SMART enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10129 -- EVT_SMART_DISABLED svrTrapAdapterSMARTDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SMART disabled." --#TYPE "SMART disabled" --#SUMMARY "Adapter %s: SMART disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10130 -- EVT_SMART_POLL_INTERVAL_CHANGED svrTrapAdapterSMARTPollIntervalChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SMART poll interval changed." --#TYPE "SMART poll interval changed" --#SUMMARY "Adapter %s: SMART poll interval changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10131 -- EVT_SCAN_CONFIGURATION svrTrapAdapterConfigChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Configuration rescanned." --#TYPE "Configuration rescanned" --#SUMMARY "Adapter %s: Configuration rescanned (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10132 -- EVT_CLEAR_CONFIGURATION svrTrapAdapterConfigCleared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Configuration cleared." --#TYPE "Configuration cleared" --#SUMMARY "Adapter %s: Configuration cleared (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10133 -- EVT_ACTIVITY_CHANGED svrTrapAdapterActivityChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Activity changed." --#TYPE "Activity changed" --#SUMMARY "Adapter %s: Activity changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10134 -- EVT_WIDE_TERMINATION svrTrapChannelTerminationWide TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Channel termination set to wide." --#TYPE "Channel termination set to wide" --#SUMMARY "Adapter %s: Channel %s termination set to wide (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10135 -- EVT_NARROW_TERMINATION svrTrapChannelTerminationNarrow TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Channel termination set to narrow." --#TYPE "Channel termination set to narrow" --#SUMMARY "Adapter %s: Channel %s termination set to narrow (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10136 -- EVT_TERMINATION_DISABLED svrTrapChannelTerminationDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Channel termination disabled." --#TYPE "Channel termination disabled" --#SUMMARY "Adapter %s: Channel %s termination disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10137 -- EVT_ACTIVE_CHANNEL svrTrapChannelActivated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Channel activated." --#TYPE "Channel activated" --#SUMMARY "Adapter %s: Channel %s activated (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10138 -- EVT_QUIET_CHANNEL svrTrapChannelDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Channel disabled." --#TYPE "Channel disabled" --#SUMMARY "Adapter %s: Channel %s disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Connection issue. 2) Check all of your cabling." --#STATE NONOPERATIONAL ::= 10139 -- EVT_DEDICATED_CHANNEL svrTrapChannelDedicated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Channel set to dedicated." --#TYPE "Channel set to dedicated" --#SUMMARY "Adapter %s: Channel %s set to dedicated (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10140 -- EVT_SHARED_CHANNEL svrTrapChannelShared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Channel set to shared." --#TYPE "Channel set to shared" --#SUMMARY "Adapter %s: Channel %s set to shared (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10141 -- EVT_LOGICALDRIVE_READAHEAD_ENABLED svrTrapLDReadAheadEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive: Read-ahead enabled." --#TYPE "Logical drive: Read-ahead enabled" --#SUMMARY "Adapter %s: Logical drive %s: Read-ahead enabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10142 -- EVT_LOGICALDRIVE_READAHEAD_DISABLED svrTrapLDReadAheadDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive: Read-ahead disabled." --#TYPE "Logical drive: Read-ahead disabled" --#SUMMARY "Adapter %s: Logical drive %s: Read-ahead disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10143 -- EVT_ADAPTIVE_READAHEAD_ENABLED svrTrapLDAdaptiveReadAheadEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive: Adaptive read-ahead enabled." --#TYPE "Logical drive: Adaptive read-ahead enabled" --#SUMMARY "Adapter %s: Logical drive %s: Adaptive read-ahead enabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10144 -- EVT_WRITE_THROUGH svrTrapLDWriteModeWriteThrough TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive: Write mode set to Write-through." --#TYPE "Logical drive: Write mode set to Write-through" --#SUMMARY "Adapter %s: Logical drive %s: Write mode set to Write-through (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10145 -- EVT_WRITE_BACK svrTrapLDWriteModeWriteBack TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive: Write mode set to Write-back." --#TYPE "Logical drive: Write mode set to Write-back" --#SUMMARY "Adapter %s: Logical drive %s: Write mode set to Write-back (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10146 -- EVT_DIRECT svrTrapLSIOModeDirect TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive: I/O mode set to direct." --#TYPE "Logical drive: I/O mode set to direct" --#SUMMARY "Adapter %s: Logical drive %s: I/O mode set to direct (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10147 -- EVT_CACHED svrTrapLSIOModeCached TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive: I/O mode set to cached." --#TYPE "Logical drive: I/O mode set to cached" --#SUMMARY "Adapter %s: Logical drive %s: I/O mode set to cached (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10148 -- EVT_TRANSFER_SPEED svrTrapPDTransferSpeedChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Max. transfer speed of disk changed (after next Reboot)." --#TYPE "Max. transfer speed of disk changed (after next Reboot)" --#SUMMARY "Adapter %s: Max. transfer speed of disk (%s) changed (after next reboot) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10149 -- EVT_BUS_WIDTH svrTrapPDBusWidthChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bus width of disk changed (after next Reboot)." --#TYPE "Bus width of disk changed (after next Reboot)" --#SUMMARY "Adapter %s: Bus width of disk (%s) changed (after next reboot) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10150 -- EVT_BBU_VOLTAGE_PROBLEM svrTrapBBUVoltageProblemDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU voltage problem detected." --#TYPE "BBU voltage problem detected" --#SUMMARY "Adapter %s: BBU voltage problem detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check connection between BBU data/power cable and RAID controller. 2) Check version of RAID controller/iRMC firmware, and BIOS. 3) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10151 -- EVT_BBU_TEMPATURE_PROBLEM svrTrapBBUTempProblemDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU temperature problem detected." --#TYPE "BBU temperature problem detected" --#SUMMARY "Adapter %s: BBU temperature problem detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check installation of all air flow channels, closed housing, and unblocked louvers. 2) Check environmental temperature. 3) Check version of RAID controller/iRMC firmware, and BIOS." --#STATE OPERATIONAL ::= 10152 -- EVT_BBU_CHARGING svrTrapBBUCharging TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU charging." --#TYPE "BBU charging" --#SUMMARY "Adapter %s: BBU charging (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10153 -- EVT_BBU_FAILED svrTrapBBUFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU failed." --#TYPE "BBU failed" --#SUMMARY "Adapter %s: BBU failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Note: Only informational during recalibration process. 1) Check connection between BBU data/power cable and RAID controller. 2) Check version of RAID controller/iRMC firmware, and BIOS. 3) If problem persists replace BBU." --#STATE NONOPERATIONAL ::= 10154 -- EVT_BBU_NORMAL svrTrapBBUNormal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU normal." --#TYPE "BBU normal" --#SUMMARY "Adapter %s: BBU normal (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10155 -- EVT_BBU_DISCHARGING svrTrapBBUDischarging TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU discharging." --#TYPE "BBU discharging" --#SUMMARY "Adapter %s: BBU discharging (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10156 -- EVT_DISK_ERROR_FIXED svrTrapAdapterDiskErrorFixed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk error fixed." --#TYPE "Disk error fixed" --#SUMMARY "Adapter %s: Disk error fixed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10157 -- EVT_DRIVER_WRITE_CACHE_ENABLED svrTrapAdapterDriverWriteCacheEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Driver write cache enabled." --#TYPE "Driver write cache enabled" --#SUMMARY "Adapter %s: Driver write cache enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10158 -- EVT_DRIVER_WRITE_CACHE_DISABLED svrTrapAdapterDriverWriteCacheDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Driver write cache disabled." --#TYPE "Driver write cache disabled" --#SUMMARY "Adapter %s: Driver write cache disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10159 -- EVT_GB_BOUNDARY_ENABLED svrTrapAdapterDriveSizingEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Drive sizing (GB Boundary) enabled." --#TYPE "Drive sizing (GB Boundary) enabled" --#SUMMARY "Adapter %s: Drive sizing (GB boundary) enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10160 -- EVT_GB_BOUNDARY_DISABLED svrTrapAdapterDriveSizingDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Drive sizing (GB Boundary) disabled." --#TYPE "Drive sizing (GB Boundary) disabled" --#SUMMARY "Adapter %s: Drive sizing (GB boundary) disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10161 -- EVT_HOTSPARE_REBUILD_ENABLED svrTrapAdapterHotspareAndAutomaticRebuildEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hot spare support and automatic rebuild enabled." --#TYPE "Hot spare support and automatic rebuild enabled" --#SUMMARY "Adapter %s: Hot spare support and automatic rebuild enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10162 -- EVT_HOTSPARE_REBUILD_DISABLED svrTrapAdapterHotspareAndAutomaticRebuildDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hot spare support and automatic rebuild disabled." --#TYPE "Hot spare support and automatic rebuild disabled" --#SUMMARY "Adapter %s: Hot spare support and automatic rebuild disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10163 -- EVT_TASK_RATE_CHANGED svrTrapAdapterTaskRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Task rate changed." --#TYPE "Task rate changed" --#SUMMARY "Adapter %s: Task rate changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10164 -- EVT_INCONSISTENCY_POLICY_CHECK svrTrapAdapterInonHandlingCheck TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Inconsistency handling set to consistency check." --#TYPE "Inconsistency handling set to consistency check" --#SUMMARY "Adapter %s: Inconsistency handling set to consistency check (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10165 -- EVT_INCONSISTENCY_POLICY_CHECK_ABORT svrTrapAdapterInonHandlingCheckAbort TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Inconsistency handling set to consistency check (abort on first inconsistency)." --#TYPE "Inconsistency handling set to consistency check (abort on first inconsistency)" --#SUMMARY "Adapter %s: Inconsistency handling set to consistency check (abort on first inconsistency) (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10166 -- EVT_INCONSISTENCY_POLICY_MDC svrTrapAdapterInonHandlingMDC TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Inconsistency handling set to MDC." --#TYPE "Inconsistency handling set to MDC" --#SUMMARY "Adapter %s: Inconsistency handling set to MDC (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10167 -- EVT_LOGICALDRIVE_NAME_CHANGED svrTrapLDNameChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive: Name changed." --#TYPE "Logical drive: Name changed" --#SUMMARY "Adapter %s: Logical drive %s: Name changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10168 -- EVT_LOGICALDRIVE_WRITE_MODE_CHANGED svrTrapLDCacheWriteModeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive: Cache write mode changed." --#TYPE "Logical drive: Cache write mode changed" --#SUMMARY "Adapter %s: Logical drive %s: Cache write mode changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10169 -- EVT_REBOOT_REQUIRED svrTrapRebootRequired TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reboot required." --#TYPE "Reboot required" --#SUMMARY "Reboot required (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10170 -- EVT_LOGIN svrTrapModuleLoggedIn TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Module logged in." --#TYPE "Module logged in" --#SUMMARY "User %s (%s) logged in (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10171 -- EVT_LOGOUT svrTrapModuleLoggedOut TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Module logged out." --#TYPE "Module logged out" --#SUMMARY "User %s (%s) logged out (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10172 -- EVT_HOTSPARE_ENABLED svrTrapAdapterHotspareEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hot spare enabled." --#TYPE "Hot spare enabled" --#SUMMARY "Adapter %s: Hot spare enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10173 -- EVT_HOTSPARE_DISABLED svrTrapAdapterHotspareDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hot spare disabled." --#TYPE "Hot spare disabled" --#SUMMARY "Adapter %s: Hot spare disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10174 -- EVT_HOTSWAP_ENABLED svrTrapAdapterHotswapEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hotswap enabled." --#TYPE "Hotswap enabled" --#SUMMARY "Adapter %s: Hot swap enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10175 -- EVT_HOTSWAP_DISABLED svrTrapAdapterHotswapDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hotswap disabled." --#TYPE "Hotswap disabled" --#SUMMARY "Adapter %s: Hot swap disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10176 -- EVT_WRITE_MODE_BACK svrTrapAdapterWriteModeWriteBack TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write mode set to Write-back." --#TYPE "Write mode set to Write-back" --#SUMMARY "Adapter %s: Write mode set to Write-back (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10177 -- EVT_WRITE_MODE_WRITETHROUGH svrTrapAdapterWriteModeWriteThrough TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write mode set to Write-through." --#TYPE "Write mode set to Write-through" --#SUMMARY "Adapter %s: Write mode set to Write-through (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10178 -- EVT_WRITE_MODE_ADAPTIVE svrTrapAdapterWriteModeAdaptive TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write mode set to adaptive." --#TYPE "Write mode set to adaptive" --#SUMMARY "Adapter %s: Write mode set to Adaptive (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10179 -- EVT_BATTERY_CHARGE_STARTED svrTrapBatteryChargeStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU charging started." --#TYPE "BBU charging started" --#SUMMARY "Adapter %s: BBU charging started (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10180 -- EVT_RAID5_INIT_ENABLED svrTrapAdapterAutomaticRAID5InitEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic initialization of RAID-5 enabled." --#TYPE "Automatic initialization of RAID-5 enabled" --#SUMMARY "Adapter %s: Automatic initialization of RAID-5 enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10181 -- EVT_RAID5_INIT_DISABLED svrTrapAdapterAutomaticRAID5InitDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic initialization of RAID-5 disabled." --#TYPE "Automatic initialization of RAID-5 disabled" --#SUMMARY "Adapter %s: Automatic initialization of RAID-5 disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10182 -- EVT_COPY_BACK_ENABLED svrTrapAdapterCopyBackEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback enabled." --#TYPE "Copyback enabled" --#SUMMARY "Adapter %s: Copyback enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10183 -- EVT_COPY_BACK_DISABLED svrTrapAdapterCopyBackDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback disabled." --#TYPE "Copyback disabled" --#SUMMARY "Adapter %s: Copyback disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10184 -- EVT_CLEAR_INITIALIZATION svrTrapAdapterInitClear TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization set to clear." --#TYPE "Initialization set to clear" --#SUMMARY "Adapter %s: Initialization set to clear (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10185 -- EVT_VERIFY_STARTED svrTrapPDVerifyStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Verify started." --#TYPE "Verify started" --#SUMMARY "Adapter %s: Verification started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10186 -- EVT_VERIFY_FINISHED svrTrapPDVerifyFinished TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Verify finished." --#TYPE "Verify finished" --#SUMMARY "Adapter %s: Verification finished on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10187 -- EVT_LOGICALDRIVE_READ_MODE_CHANGED svrTrapLDReadModeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache read mode changed." --#TYPE "Cache read mode changed" --#SUMMARY "Adapter %s: Logical drive %s: Cache read mode changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10188 -- EVT_LOGICALDRIVE_CACHE_MODE_CHANGED svrTrapLDCacheModeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache mode changed." --#TYPE "Cache mode changed" --#SUMMARY "Adapter %s: Logical drive %s: Cache mode changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10189 -- EVT_LOGICALDRIVE_ACCESS_MODE_CHANGED svrTrapLDAcessModeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Access mode changed." --#TYPE "Access mode changed" --#SUMMARY "Adapter %s: Logical drive %s: Access mode changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10190 -- EVT_LOGICALDRIVE_BGI_MODE_CHANGED svrTrapLDBGIModeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI mode changed." --#TYPE "BGI mode changed" --#SUMMARY "Adapter %s: Logical drive %s: BGI mode changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10191 -- EVT_LOGICALDRIVE_DISK_CACHE_MODE_CHANGED svrTrapLDDiskCacheModeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk cache mode changed." --#TYPE "Disk cache mode changed" --#SUMMARY "Adapter %s: Logical drive %s: Disk cache mode changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10192 -- EVT_BOOT svrTrapBoot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware initialization started." --#TYPE "Firmware initialization started" --#SUMMARY "Adapter %s: Firmware initialization started (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10193 -- EVT_VERSION svrTrapVersion TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware version." --#TYPE "Firmware version" --#SUMMARY "Adapter %s: Firmware version %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10194 -- EVT_BBU_TBBU_DIRTY_CACHE_CONFIG_MISMATCH svrTrapBBUTBBUDirtyCacheConfigMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unable to recover cache data from TBBU." --#TYPE "Unable to recover cache data from TBBU" --#SUMMARY "Adapter %s: Unable to recover cache data from TBBU (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10195 -- EVT_BBU_TBBU_DIRTY_CACHE_PROCESSED svrTrapBBUTBBUDirtyCacheProcessed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache data recovered from TBBU successfully." --#TYPE "Cache data recovered from TBBU successfully" --#SUMMARY "Adapter %s: Cache data recovered from TBBU successfully (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10196 -- EVT_CLUST_DOWN svrTrapClustDown TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cluster down; communication with peer lost." --#TYPE "Cluster down; communication with peer lost" --#SUMMARY "Adapter %s: Cluster down; communication with peer lost (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10197 -- EVT_CLUST_OWNERSHIP_CHANGE svrTrapClustOwnershipChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Ownership changed." --#TYPE "Ownership changed" --#SUMMARY "Adapter %s: %s ownership changed from %s to %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10198 -- EVT_CTRL_BGI_RATE_CHANGED svrTrapCtrlBGIRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Background initialization rate changed." --#TYPE "Background initialization rate changed" --#SUMMARY "Adapter %s: BGI rate changed to %s percent (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10199 -- EVT_CTRL_CACHE_DISCARDED svrTrapCtrlCacheDiscarded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Controller cache discarded." --#TYPE "Controller cache discarded" --#SUMMARY "Adapter %s: Adapter cache discarded due to memory/BBU problems (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10200 -- EVT_CTRL_CACHE_REBOOT_CANT_RECOVER svrTrapCtrlCacheRebootCantRecover TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unable to recover cache data." --#TYPE "Unable to recover cache data" --#SUMMARY "Adapter %s: Unable to recover cache data due to configuration mismatch (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10201 -- EVT_CTRL_CACHE_REBOOT_RECOVER svrTrapCtrlCacheRebootRecover TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache data recovered successfully." --#TYPE "Cache data recovered successfully" --#SUMMARY "Adapter %s: Cache data recovered successfully (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10202 -- EVT_CTRL_CACHE_VERSION_MISMATCH svrTrapCtrlCacheVersionMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Controller cache discarded." --#TYPE "Controller cache discarded" --#SUMMARY "Adapter %s: Adapter cache discarded due to firmware version incompatibility (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check version of RAID controller/iRMC firmware, and BIOS." --#STATE OPERATIONAL ::= 10203 -- EVT_CTRL_CRASH svrTrapCtrlCrash TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Fatal firmware error." --#TYPE "Fatal firmware error" --#SUMMARY "Adapter %s: Fatal firmware error: %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Disconnect AC and wait 30 seconds before reconnect." --#STATE NONOPERATIONAL ::= 10204 -- EVT_CTRL_FACTORY_DEFAULTS svrTrapCtrlFactoryDefaults TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Factory defaults restored." --#TYPE "Factory defaults restored" --#SUMMARY "Adapter %s: Factory defaults restored (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10205 -- EVT_CTRL_FLASH_BAD_IMAGE svrTrapCtrlFlashBadImage TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash downloaded image corrupt." --#TYPE "Flash downloaded image corrupt" --#SUMMARY "Adapter %s: Flash downloaded image corrupt (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Download again. 2) Retry flash." --#STATE OPERATIONAL ::= 10206 -- EVT_CTRL_FLASH_ERASE_ERROR svrTrapCtrlFlashEraseError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash erase error." --#TYPE "Flash erase error" --#SUMMARY "Adapter %s: Flash erase error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10207 -- EVT_CTRL_FLASH_ERASE_TIMEOUT svrTrapCtrlFlashEraseTimeout TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash timeout during erase." --#TYPE "Flash timeout during erase" --#SUMMARY "Adapter %s: Flash timeout during erase (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Retry flash. 2) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10208 -- EVT_CTRL_FLASH_GENERAL_ERROR svrTrapCtrlFlashGeneralError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash error." --#TYPE "Flash error" --#SUMMARY "Adapter %s: Flash error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Retry flash. 2) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10209 -- EVT_CTRL_FLASH_IMAGE svrTrapCtrlFlashImage TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flashing image." --#TYPE "Flashing image" --#SUMMARY "Adapter %s: Flashing image: %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10210 -- EVT_CTRL_FLASH_OK svrTrapCtrlFlashOK TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash complete." --#TYPE "Flash complete" --#SUMMARY "Adapter %s: Flash of new firmware image(s) complete (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10211 -- EVT_CTRL_FLASH_PROGRAM_ERROR svrTrapCtrlFlashProgramError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash programming error." --#TYPE "Flash programming error" --#SUMMARY "Adapter %s: Flash programming error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Retry flash. 2) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10212 -- EVT_CTRL_FLASH_PROGRAM_TIMEOUT svrTrapCtrlFlashProgramTimeout TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash timeout during programming." --#TYPE "Flash timeout during programming" --#SUMMARY "Adapter %s: Flash timeout during programming (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Retry flash. 2) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10213 -- EVT_CTRL_FLASH_UNKNOWN_CHIP_TYPE svrTrapCtrlFlashUnknownChipType TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash chip type unknown." --#TYPE "Flash chip type unknown" --#SUMMARY "Adapter %s: Flash chip type unknown (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Retry flash. 2) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10214 -- EVT_CTRL_FLASH_UNKNOWN_CMD_SET svrTrapCtrlFlashUnknownCmdSet TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash command set unknown." --#TYPE "Flash command set unknown" --#SUMMARY "Adapter %s: Flash command set unknown (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Retry flash. 2) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10215 -- EVT_CTRL_FLASH_VERIFY_FAILURE svrTrapCtrlFlashVerifyFailure TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash verify failure." --#TYPE "Flash verify failure" --#SUMMARY "Adapter %s: Flash verification failure (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Retry flash. 2) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10216 -- EVT_CTRL_FLUSH_RATE_CHANGED svrTrapCtrlFlushRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flush rate changed." --#TYPE "Flush rate changed" --#SUMMARY "Adapter %s: Flush rate changed to %s seconds (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10217 -- EVT_CTRL_HIBERNATE svrTrapCtrlHibernate TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hibernate command received." --#TYPE "Hibernate command received" --#SUMMARY "Adapter %s: Hibernate command received from host (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10218 -- EVT_CTRL_LOG_CLEARED svrTrapCtrlLogCleared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Event log cleared." --#TYPE "Event log cleared" --#SUMMARY "Adapter %s: Event log cleared (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10219 -- EVT_CTRL_LOG_WRAPPED svrTrapCtrlLogWrapped TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Event log wrapped." --#TYPE "Event log wrapped" --#SUMMARY "Adapter %s: Event log wrapped (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10220 -- EVT_CTRL_MEM_ECC_MULTI_BIT svrTrapCtrlMemECCMultiBit TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Multi-bit ECC error." --#TYPE "Multi-bit ECC error" --#SUMMARY "Adapter %s: Multi-bit ECC error: ECAR=%s, ELOG=%s, (%s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "If the problem occurs repeatedly replace the RAID controller DIMM module (cache)." --#STATE OPERATIONAL ::= 10221 -- EVT_CTRL_MEM_ECC_SINGLE_BIT svrTrapCtrlMemECCSingleBit TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Single-bit ECC error." --#TYPE "Single-bit ECC error" --#SUMMARY "Adapter %s: Single-bit ECC error: ECAR=%s, ELOG=%s, (%s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "If the problem occurs repeatedly replace the RAID controller DIMM module (cache)." --#STATE OPERATIONAL ::= 10222 -- EVT_CTRL_NOT_ENOUGH_MEMORY svrTrapCtrlNotEnoughMemory TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Not enough controller memory." --#TYPE "Not enough controller memory" --#SUMMARY "Adapter %s: Not enough adapter memory (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Replace the RAID controller DIMM module (cache). 2) If problem persists replace RAID controller." --#STATE OPERATIONAL ::= 10223 -- EVT_CTRL_PR_RATE_CHANGED svrTrapCtrlPrRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read rate changed." --#TYPE "Patrol Read rate changed" --#SUMMARY "Adapter %s: Patrol Read rate changed to %s percent (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10224 -- EVT_CTRL_RECON_RATE_CHANGED svrTrapCtrlReconRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reconstruction rate changed." --#TYPE "Reconstruction rate changed" --#SUMMARY "Adapter %s: Migration rate changed to %s percent (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10225 -- EVT_CTRL_SHUTDOWN svrTrapCtrlShutdown TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Shutdown command received." --#TYPE "Shutdown command received" --#SUMMARY "Adapter %s: Shutdown command received from host (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10226 -- EVT_CTRL_TEST svrTrapCtrlTest TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Test event." --#TYPE "Test event" --#SUMMARY "Adapter %s: Test event: '%s' (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10227 -- EVT_CTRL_TIME_SET svrTrapCTrlTimeSet TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Time established." --#TYPE "Time established" --#SUMMARY "Adapter %s: Time established as %s; (%s seconds since power on) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10228 -- EVT_CTRL_USER_ENTERED_DEBUGGER svrTrapCtrlUserEnteredDebugger TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "User entered firmware debugger." --#TYPE "User entered firmware debugger" --#SUMMARY "Adapter %s: User entered firmware debugger (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10229 -- EVT_LD_BGI_CORRECTED_MEDIUM_ERROR svrTrapLDBGICorrectedMediumError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI corrected medium error." --#TYPE "BGI corrected medium error" --#SUMMARY "Adapter %s: BGI corrected medium error (logical drive %s at LBA %s on disk (%s) at LBA %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10230 -- EVT_LD_BGI_DONE_ERRORS svrTrapLDBGIDoneErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI finished with uncorrectable errors." --#TYPE "BGI finished with uncorrectable errors" --#SUMMARY "Adapter %s: BGI finished with uncorrectable errors on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Initiate consistency check (e.g. via ServerView RAID Manager)." --#STATE OPERATIONAL ::= 10231 -- EVT_LD_BGI_DOUBLE_MEDIUM_ERRORS svrTrapLDBGIDoubleMediumErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI detected uncorrectable double medium errors." --#TYPE "BGI detected uncorrectable double medium errors" --#SUMMARY "Adapter %s: BGI detected uncorrectable multiple medium errors (disk (%s) at LBA %s on logical drive %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10232 -- EVT_LD_BGI_FAILED svrTrapLDBGIFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI failed." --#TYPE "BGI failed" --#SUMMARY "Adapter %s: BGI failed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Restart Background initialization (BGI). 2) Replace affected disk." --#STATE OPERATIONAL ::= 10233 -- EVT_LD_BGI_PROGRESS svrTrapLDBGIProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI progress." --#TYPE "BGI progress" --#SUMMARY "Adapter %s: BGI progress on logical drive %s is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10234 -- EVT_LD_CACHE_POLICY_CHANGE svrTrapLDCachePolicyChange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Policy change." --#TYPE "Policy change" --#SUMMARY "Adapter %s: Logical drive %s: %s changed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10235 -- EVT_LD_MDC_CORRECTED_MEDIUM_ERROR svrTrapLDMDCCorrectedMediumError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC corrected medium error." --#TYPE "MDC corrected medium error" --#SUMMARY "Adapter %s: MDC corrected medium error (logical drive %s at LBA %s on disk (%s) at LBA %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10236 -- EVT_LD_CC_INCONSISTENT_PARITY svrTrapLDCCInconsistentParity TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check found inconsistent parity." --#TYPE "Consistency check found inconsistent parity" --#SUMMARY "Adapter %s: Consistency check found inconsistent parity on logical drive %s at stripe %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Start consistency check again. 2) If problem persists backup data from affected logical drive. 3) Delete and recreate affected logical drive. 4) Restore data." --#STATE OPERATIONAL ::= 10237 -- EVT_LD_CC_INCONSISTENT_PARITY_LOGGING_DISABLED svrTrapLDCCInconsistentParityLoggingDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check inconsistency logging disabled." --#TYPE "Consistency check inconsistency logging disabled" --#SUMMARY "Adapter %s: Consistency check logging disabled on logical drive %s (too many Inconsistencies) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10238 -- EVT_LD_CC_PROGRESS svrTrapLDCCProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check progress." --#TYPE "Consistency check progress" --#SUMMARY "Adapter %s: Consistency check progress on %s is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10239 -- EVT_LD_INIT_FAILED svrTrapLDInitFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization failed." --#TYPE "Initialization failed" --#SUMMARY "Adapter %s: Initialization failed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Start initialization again." --#STATE OPERATIONAL ::= 10240 -- EVT_LD_INIT_PROGRESS svrTrapLDInitProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization progress." --#TYPE "Initialization progress" --#SUMMARY "Adapter %s: Initialization progress on logical drive %s is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10241 -- EVT_LD_INIT_START_FAST svrTrapLDInitStartFast TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Fast initialization started." --#TYPE "Fast initialization started" --#SUMMARY "Adapter %s: Fast initialization started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10242 -- EVT_LD_INIT_START_FULL svrTrapLDInitStartFull TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Full initialization started." --#TYPE "Full initialization started" --#SUMMARY "Adapter %s: Full initialization started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10243 -- EVT_LD_PROP_CHANGE svrTrapLDPropChange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Properties updated." --#TYPE "Properties updated" --#SUMMARY "Adapter %s: Logical drive %s: Property %s updated (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10244 -- EVT_LD_RECON_DOUBLE_MEDIUM_ERRORS svrTrapLDReconDoubleMediumErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reconstruct detected uncorrectable double medium errors." --#TYPE "Reconstruct detected uncorrectable double medium errors" --#SUMMARY "Adapter %s: Migration detected uncorrectable multiple medium errors (logical drive %s at LBA %s on disk (%s) at LBA %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10245 -- EVT_LD_RECON_PROGRESS svrTrapLDReconProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reconstruction progress." --#TYPE "Reconstruction progress" --#SUMMARY "Adapter %s: Migration progress on logical drive %s is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10246 -- EVT_LD_RECON_RESUME svrTrapLDReconResume TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reconstruction resumed." --#TYPE "Reconstruction resumed" --#SUMMARY "Adapter %s: Migration resumed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10247 -- EVT_LD_RECON_RESUME_FAILED svrTrapLDReconResumeFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reconstruction resume failed." --#TYPE "Reconstruction resume failed" --#SUMMARY "Adapter %s: Resume migration of logical drive %s failed due to Configuration Mismatch (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check the RAID configuration and the event log for additional information. 2) Backup data from affected logical drive." --#STATE OPERATIONAL ::= 10248 -- EVT_LD_STATE_CHANGE_OP_TO_OP svrTrapLDStateChangedOpToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to operational." --#TYPE "State change from operational to operational" --#SUMMARY "Adapter %s: State change on logical drive %s from operational to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10249 -- EVT_PD_CLEAR_ABORTED svrTrapPDClearAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Clear aborted." --#TYPE "Clear aborted" --#SUMMARY "Adapter %s: Clear aborted on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10250 -- EVT_PD_CLEAR_FAILED svrTrapPDClearFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Clear failed." --#TYPE "Clear failed" --#SUMMARY "Adapter %s: Clear failed on disk (%s) (error %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check version of RAID controller/iRMC firmware, and BIOS. 2) Verify that current RAID controller drivers are installed. 3) Disconnect AC and wait 30 seconds before reconnect." --#STATE OPERATIONAL ::= 10251 -- EVT_PD_CLEAR_PROGRESS svrTrapLDClearProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Clear progress." --#TYPE "Clear progress" --#SUMMARY "Adapter %s: Clear progress on disk (%s) is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10252 -- EVT_PD_CLEAR_STARTED svrTrapPDClearStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Clear started." --#TYPE "Clear started" --#SUMMARY "Adapter %s: Clear started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10253 -- EVT_PD_CLEAR_SUCCESSFUL svrTrapPDClearSuccessful TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Clear finished." --#TYPE "Clear finished" --#SUMMARY "Adapter %s: Clear finished on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10254 -- EVT_PD_ERR svrTrapPDErr TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Error on disk." --#TYPE "Error on disk" --#SUMMARY "Adapter %s: Error on disk (%s) (error %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10255 -- EVT_PD_FORMAT_COMPLETE svrTrapPDFormatComplete TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Format complete." --#TYPE "Format complete" --#SUMMARY "Adapter %s: Format complete on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10256 -- EVT_PD_FORMAT_STARTED svrTrapPDFormatStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Format started." --#TYPE "Format started" --#SUMMARY "Adapter %s: Format started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10257 -- EVT_PD_HS_SMART_POLL_FAILED svrTrapPDHSSmartPollFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hot spare SMART polling failed." --#TYPE "Hot spare SMART polling failed" --#SUMMARY "Adapter %s: Hot spare SMART polling failed on disk (%s) (error %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10258 -- EVT_PD_NOT_SUPPORTED svrTrapPDNotSupported TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk not supported." --#TYPE "Disk not supported" --#SUMMARY "Adapter %s: Disk (%s) is not supported (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Install supported disk." --#STATE OPERATIONAL ::= 10259 -- EVT_PD_PR_CORRECTED svrTrapPDPRCorrected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read corrected medium error." --#TYPE "Patrol Read corrected medium error" --#SUMMARY "Adapter %s: Patrol Read corrected medium error on disk (%s) at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10260 -- EVT_PD_PR_PROGRESS svrTrapPDPRProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read progress." --#TYPE "Patrol Read progress" --#SUMMARY "Adapter %s: Patrol Read progress on disk (%s) is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10261 -- EVT_PD_PR_UNCORRECTABLE svrTrapPDPRUncorrectable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read found an uncorrectable medium error." --#TYPE "Patrol Read found an uncorrectable medium error" --#SUMMARY "Adapter %s: Patrol Read found an uncorrectable medium error on disk (%s) at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10262 -- EVT_PD_PREDICTIVE_THRESHOLD_EXCEEDED svrTrapPDPredictiveThresholdExceeded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Predictive failure." --#TYPE "Predictive failure" --#SUMMARY "Adapter %s: Predictive failure: Disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Disk reports a prefailure. The affected disk might fail soon. 1) Replace the disk during next maintenance." --#STATE OPERATIONAL ::= 10263 -- EVT_PD_PUNCTURE svrTrapPDPuncture TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Puncturing bad block." --#TYPE "Puncturing bad block" --#SUMMARY "Adapter %s: Puncturing bad block on disk (%s) at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10264 -- EVT_PD_RBLD_ABORT_BY_USER svrTrapPDRbldAbortByUser TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild aborted by user." --#TYPE "Rebuild aborted by user" --#SUMMARY "Adapter %s: Rebuild aborted by user on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10265 -- EVT_PD_RBLD_DONE_LD svrTrapPDRbldDoneLD TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild complete on logical drive." --#TYPE "Rebuild complete on logical drive" --#SUMMARY "Adapter %s: Rebuild complete on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10266 -- EVT_PD_RBLD_DONE_PD svrTrapPDRbldDonePD TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild complete on disk." --#TYPE "Rebuild complete on disk" --#SUMMARY "Adapter %s: Rebuild complete on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10267 -- EVT_PD_RBLD_PROGRESS svrTrapPDRbldProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild progress." --#TYPE "Rebuild progress" --#SUMMARY "Adapter %s: Rebuild progress on disk (%s) is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10268 -- EVT_PD_RBLD_RESUME svrTrapPDRbldResume TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild resumed." --#TYPE "Rebuild resumed" --#SUMMARY "Adapter %s: Rebuild resumed on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10269 -- EVT_PD_RBLD_START_AUTO svrTrapPDRbldStartAuto TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild automatically started." --#TYPE "Rebuild automatically started" --#SUMMARY "Adapter %s: Rebuild automatically started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10270 -- EVT_PD_RBLD_STOP_BY_OWNERSHIP_LOSS svrTrapPDRbldStopByOwnershipLoss TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild stopped." --#TYPE "Rebuild stopped" --#SUMMARY "Adapter %s: Rebuild stopped on disk (%s) due to loss of cluster ownership (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Restart rebuild." --#STATE DEGRADED ::= 10271 -- EVT_PD_REASSIGN_WRITE_FAILED svrTrapPDReassignWriteFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reassign write operation failed." --#TYPE "Reassign write operation failed" --#SUMMARY "Adapter %s: Reassign write operation failed on disk (%s) at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10272 -- EVT_PD_REBUILD_MEDIUM_ERROR svrTrapPDRebuildMediumError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unrecoverable medium error during rebuild." --#TYPE "Unrecoverable medium error during rebuild" --#SUMMARY "Adapter %s: Unrecoverable medium error during rebuild on disk (%s) at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE DEGRADED ::= 10273 -- EVT_PD_REC_CORRECTING svrTrapPDRecCorrecting TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Corrected medium error during recovery." --#TYPE "Corrected medium error during recovery" --#SUMMARY "Adapter %s: Corrected medium error during recovery on disk (%s) at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10274 -- EVT_PD_RECOVER_MEDIUM_ERROR svrTrapPDRecoverMediumError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unrecoverable medium error during recovery." --#TYPE "Unrecoverable medium error during recovery" --#SUMMARY "Adapter %s: Unrecoverable medium error during recovery on disk (%s) at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10275 -- EVT_PD_SENSE svrTrapPDSense TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unexpected sense." --#TYPE "Unexpected sense" --#SUMMARY "Adapter %s: Unexpected sense: Disk (%s), Key/ASC/ASCQ: %s: %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10276 -- EVT_PD_STATE_CHANGE_AVAIL_TO_AVAIL svrTrapPDStateChangeAvailToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from available to available." --#TYPE "State change from available to available" --#SUMMARY "Adapter %s: State change on disk (%s) from available to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10277 -- EVT_PD_STATE_CHANGE_BY_USER_AVAIL_TO_AVAIL svrTrapPDStateChangeByUserAvailToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from available to available." --#TYPE "State change by user from available to available" --#SUMMARY "Adapter %s: State change by user on disk (%s) from available to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10278 -- EVT_PD_REDUNDANT_PATH_BROKEN svrTrapPDRedundantPathBroken TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundant path broken." --#TYPE "Redundant path broken" --#SUMMARY "Adapter %s: Redundant path to disk (%s) broken (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10279 -- EVT_PD_REDUNDANT_PATH_RESTORED svrTrapPDRedundantPathRestored TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundant path restored." --#TYPE "Redundant path restored" --#SUMMARY "Adapter %s: Redundant path to disk (%s) restored (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10280 -- EVT_PD_DEDICATED_SPARE_NO_LONGER_USEFUL svrTrapPDDedicatedSpareNoLongerUseful TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Dedicated hot spare no longer useful." --#TYPE "Dedicated hot spare no longer useful" --#SUMMARY "Adapter %s: Dedicated hot spare (%s) no longer useful due to deleted array (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10281 -- EVT_SAS_TOPOLOGY_LOOP_DETECTED svrTrapSASTolologyLoopDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: Loop detected." --#TYPE "SAS topology error: Loop detected" --#SUMMARY "Adapter %s: SAS topology error: Loop detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10282 -- EVT_SAS_TOPOLOGY_UNADDRESSABLE_DEVICE svrTrapSASTopologyUnaddressableDevice TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: Unaddressable device." --#TYPE "SAS topology error: Unaddressable device" --#SUMMARY "Adapter %s: SAS topology error: Unaddressable device (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10283 -- EVT_SAS_TOPOLOGY_MULTIPLE_PORTS_TO_SAME_ADDR svrTrapSASTopologyMultiplePortsToSameAddr TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: Multiple ports to the same SAS address." --#TYPE "SAS topology error: Multiple ports to the same SAS address" --#SUMMARY "Adapter %s: SAS topology error: Multiple ports to the same SAS address (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10284 -- EVT_SAS_TOPOLOGY_EXPANDER_ERR svrTrapSASTopologyExpanderErr TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: Expander error." --#TYPE "SAS topology error: Expander error" --#SUMMARY "Adapter %s: SAS topology error: Expander error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check the SAS configuration and cabling. 2) If problem persists replace affected backplane." --#STATE OPERATIONAL ::= 10285 -- EVT_SAS_TOPOLOGY_SMP_TIMEOUT svrTrapSASTopologySMPTimeout TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: SMP timeout." --#TYPE "SAS topology error: SMP timeout" --#SUMMARY "Adapter %s: SAS topology error: SMP timeout (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10286 -- EVT_SAS_TOPOLOGY_OUT_OF_ROUTE_ENTRIES svrTrapSASTopologyOutOfRouteEntries TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: Out of route entries." --#TYPE "SAS topology error: Out of route entries" --#SUMMARY "Adapter %s: SAS topology error: Out of route entries (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10287 -- EVT_SAS_TOPOLOGY_INDEX_NOT_FOUND svrTrapSASTopologyIndexNotFound TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: Index not found." --#TYPE "SAS topology error: Index not found" --#SUMMARY "Adapter %s: SAS topology error: Index not found (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10288 -- EVT_SAS_TOPOLOGY_SMP_FUNCTION_FAILED svrTrapSASTopologySMPFunctionFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: SMP function failed." --#TYPE "SAS topology error: SMP function failed" --#SUMMARY "Adapter %s: SAS topology error: SMP function failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10289 -- EVT_SAS_TOPOLOGY_SMP_CRC_ERROR svrTrapSASTopologySMPCRCError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: SMP CRC error." --#TYPE "SAS topology error: SMP CRC error" --#SUMMARY "Adapter %s: SAS topology error: SMP CRC error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10290 -- EVT_SAS_TOPOLOGY_MULITPLE_SUBTRACTIVE svrTrapSASTopologyMultipleSubtractive TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: Multiple subtractive." --#TYPE "SAS topology error: Multiple subtractive" --#SUMMARY "Adapter %s: SAS topology error: Multiple subtractive (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10291 -- EVT_SAS_TOPOLOGY_TABLE_TO_TABLE svrTrapSASTopologyTableToTable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: Table to table." --#TYPE "SAS topology error: Table to table" --#SUMMARY "Adapter %s: SAS topology error: Table to table (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10292 -- EVT_SAS_TOPOLOGY_MULTIPLE_PATHS svrTrapSASTopologyMultiplePaths TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error: Multiple paths." --#TYPE "SAS topology error: Multiple paths" --#SUMMARY "Adapter %s: SAS topology error: Multiple paths (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the SAS configuration and cabling." --#STATE OPERATIONAL ::= 10293 -- EVT_PD_UNUSABLE svrTrapPDUnusable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unable to access disk." --#TYPE "Unable to access disk" --#SUMMARY "Adapter %s: Unable to access disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Unplug affected disk, wait 30 seconds, reinsert it. 2) Replace affected disk. 3) Replace affected backplane." --#STATE OPERATIONAL ::= 10294 -- EVT_PD_SPARE_DEDICATED_NOT_USEFUL_FOR_ALL_ARRAYS svrTrapPDSpareDedicatedNotUsefulForAllArrays TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Dedicated hot spare not useful for all arrays." --#TYPE "Dedicated hot spare not useful for all arrays" --#SUMMARY "Adapter %s: Dedicated hot spare not useful for all arrays (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10295 -- EVT_PD_SPARE_GLOBAL_NOT_COVERING_ALL_ARRAYS svrTrapPDSpareGlobalNotCoveringAllArrays TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Global hot spare does not cover all arrays." --#TYPE "Global hot spare does not cover all arrays" --#SUMMARY "Adapter %s: Global hot spare does not cover all arrays (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: The size of the global hot spare is not sufficient to secure all arrays." --#STATE OPERATIONAL ::= 10296 -- EVT_LD_INCONSISTENT_DUE_AT_STARTUP svrTrapLDInconsistentDueAtStartup TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Marking inconsistent." --#TYPE "Marking inconsistent" --#SUMMARY "Adapter %s: Marking logical drive %s inconsistent due to active writes at shutdown (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Initiate consistency check (e.g. via ServerView RAID Manager)." --#STATE OPERATIONAL ::= 10297 -- EVT_BBU_PRESENT svrTrapBBUPresent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU present." --#TYPE "BBU present" --#SUMMARY "Adapter %s: BBU present (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10298 -- EVT_BBU_NOT_PRESENT svrTrapBBUNotPresent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU not present." --#TYPE "BBU not present" --#SUMMARY "Adapter %s: BBU not present (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "If the system does not have a BBU this is for information only. If the system does have a BBU replace the BBU." --#STATE OPERATIONAL ::= 10299 -- EVT_BBU_NEW_BATTERY_DETECTED svrTrapBBUNewBatteryDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "New BBU detected." --#TYPE "New BBU detected" --#SUMMARY "Adapter %s: New BBU detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10300 -- EVT_BBU_REPLACED svrTrapBBUReplaced TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU has been replaced." --#TYPE "BBU has been replaced" --#SUMMARY "Adapter %s: BBU has been replaced (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10301 -- EVT_BBU_TEMPERATURE_NORMAL svrTrapBBUTemperatureNormal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU temperature is normal." --#TYPE "BBU temperature is normal" --#SUMMARY "Adapter %s: BBU temperature is normal (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10302 -- EVT_BBU_REPLACEMENT_NEEDED_SOH_BAD svrTrapBBUReplacementNeededSOHBad TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU has failed and cannot support data retention." --#TYPE "BBU needs replacement" --#SUMMARY "Adapter %s: BBU has failed and cannot support data retention (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "If the error message occurs right after replacement of the BBU it can be safely ignored. The situation can occur due to the insufficient BBU charge. If the error message occurs during regular operation replace the BBU." --#STATE OPERATIONAL ::= 10303 -- EVT_BBU_RELEARN_STARTED svrTrapBBURelearnStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn started." --#TYPE "BBU relearn started" --#SUMMARY "Adapter %s: BBU relearn started (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10304 -- EVT_BBU_RELEARN_IN_PROGRESS svrTrapBBURelearnInProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn in progress." --#TYPE "BBU relearn in progress" --#SUMMARY "Adapter %s: BBU relearn in progress (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10305 -- EVT_BBU_RELEARN_COMPLETE svrTrapBBURelearnComplete TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn finished." --#TYPE "BBU relearn finished" --#SUMMARY "Adapter %s: BBU relearn finished (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10306 -- EVT_BBU_RELEARN_TIMEOUT svrTrapBBURelearnTimeout TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn timed out." --#TYPE "BBU relearn timed out" --#SUMMARY "Adapter %s: BBU relearn timed out (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Initiate manual recalibration process (e.g. via ServerView RAID Manager). Note: Do not interrupt the charging process by reboots or shutdowns. 2) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10307 -- EVT_BBU_RELEARN_PENDING svrTrapBBURelearnPending TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn pending." --#TYPE "BBU relearn pending" --#SUMMARY "Adapter %s: BBU relearn pending: BBU is under charge (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10308 -- EVT_BBU_RELEARN_POSTPONED svrTrapBBUrelearnPostponed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn postponed." --#TYPE "BBU relearn postponed" --#SUMMARY "Adapter %s: BBU relearn postponed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10309 -- EVT_BBU_RELEARN_WILL_START_IN_4_DAYS svrTrapBBURelearnWillStartIn4Days TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn will start in 4 days." --#TYPE "BBU relearn will start in 4 days" --#SUMMARY "Adapter %s: BBU relearn will start in 4 days (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10310 -- EVT_BBU_RELEARN_WILL_START_IN_2_DAYS svrTrapBBURelearnWillStartIn2Days TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn will start in 2 days." --#TYPE "BBU relearn will start in 2 days" --#SUMMARY "Adapter %s: BBU relearn will start in 2 days (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10311 -- EVT_BBU_RELEARN_WILL_START_IN_1_DAYS svrTrapBBURelearnWillStartIn1Days TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn will start in 1 day." --#TYPE "BBU relearn will start in 1 day" --#SUMMARY "Adapter %s: BBU relearn will start in 1 day (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10312 -- EVT_BBU_RELEARN_WILL_START_IN_5_HOURS svrTrapBBURelearnWillStartIn5Hours TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn will start in 5 hours." --#TYPE "BBU relearn will start in 5 hours" --#SUMMARY "Adapter %s: BBU Relearn will start in 5 hours (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10313 -- EVT_BBU_BATTERY_REMOVED svrTrapBBUBatteryRemoved TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU removed." --#TYPE "BBU removed" --#SUMMARY "Adapter %s: BBU removed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10314 -- EVT_ENCL_DISCOVERED_SES svrTrapEnclDiscoveredSES TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure (SES) discovered." --#TYPE "Enclosure (SES) discovered" --#SUMMARY "Adapter %s: Enclosure (SES) discovered on %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10315 -- EVT_ENCL_DISCOVERED_SAFTE svrTrapEnclDiscoveredSAFTE TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure (SAF-TE) discovered." --#TYPE "Enclosure (SAF-TE) discovered" --#SUMMARY "Adapter %s: Enclosure (SAF-TE) discovered on %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10316 -- EVT_ENCL_COMMUNICATION_LOST svrTrapEnclCommunicationLost TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure communication lost." --#TYPE "Enclosure communication lost" --#SUMMARY "Adapter %s: Enclosure %s communication lost (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Check data cable(s) to enclosure. 2) Check if enclosure is running." --#STATE OPERATIONAL ::= 10317 -- EVT_ENCL_COMMUNICATION_RESTORED svrTrapEnclCommunicationRestored TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure communication restored." --#TYPE "Enclosure communication restored" --#SUMMARY "Adapter %s: Enclosure %s communication restored (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10318 -- EVT_ENCL_FAN_INSERTED svrTrapEnclFanInserted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure fan inserted." --#TYPE "Enclosure fan inserted" --#SUMMARY "Adapter %s: Enclosure %s fan %s inserted (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10319 -- EVT_ENCL_FAN_REMOVED svrTrapEnclFanRemoved TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure fan removed." --#TYPE "Enclosure fan removed" --#SUMMARY "Adapter %s: Enclosure %s fan %s removed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10320 -- EVT_ENCL_SIM_FAILED svrTrapEnclSIMFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure I/O module failed." --#TYPE "Enclosure I/O module failed" --#SUMMARY "Adapter %s: Enclosure %s I/O module %s failed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check the I/O module firmware. 2) Replace I/O module." --#STATE OPERATIONAL ::= 10321 -- EVT_ENCL_SIM_INSERTED svrTrapEnclSIMInserted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure I/O module inserted." --#TYPE "Enclosure I/O module inserted" --#SUMMARY "Adapter %s: Enclosure %s I/O module %s inserted (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10322 -- EVT_ENCL_SIM_REMOVED svrTrapEnclSimRemoved TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure I/O module removed." --#TYPE "Enclosure I/O module removed" --#SUMMARY "Adapter %s: Enclosure %s I/O module %s removed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10323 -- EVT_ENCL_SHUTDOWN svrTrapEnclShutdown TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure shutdown." --#TYPE "Enclosure shutdown" --#SUMMARY "Adapter %s: Enclosure %s shutdown (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10324 -- EVT_ENCL_MAX_PER_PORT_EXCEEDED svrTrapEnclMaxPerPortExceeded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure not supported; too many enclosures connected to port." --#TYPE "Enclosure not supported; too many enclosures connected to port" --#SUMMARY "Adapter %s: Enclosure %s not supported; too many enclosures connected to port (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your enclosure configuration." --#STATE OPERATIONAL ::= 10325 -- EVT_ENCL_FIRMWARE_MISMATCH svrTrapEnclFirmwareMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure firmware mismatch." --#TYPE "Enclosure firmware mismatch" --#SUMMARY "Adapter %s: Enclosure %s firmware mismatch (I/O module %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the I/O module firmware." --#STATE OPERATIONAL ::= 10326 -- EVT_ENCL_BAD_SENSOR svrTrapEnclBadSensor TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure sensor bad." --#TYPE "Enclosure sensor bad" --#SUMMARY "Adapter %s: Enclosure %s sensor %s bad (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the enclosure sensors." --#STATE OPERATIONAL ::= 10327 -- EVT_ENCL_BAD_PHY svrTrapEnclBadPhy TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure PHY bad." --#TYPE "Enclosure PHY bad" --#SUMMARY "Adapter %s: Enclosure %s PHY bad for slot %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10328 -- EVT_ENCL_UNSTABLE svrTrapEnclUnstable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure is unstable." --#TYPE "Enclosure is unstable" --#SUMMARY "Adapter %s: Enclosure %s is unstable (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check the I/O module firmware. 2) Check cable(s) to enclosure." --#STATE OPERATIONAL ::= 10329 -- EVT_ENCL_HARDWARE_ERROR svrTrapEnclHardwareError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure hardware error." --#TYPE "Enclosure hardware error" --#SUMMARY "Adapter %s: Enclosure %s hardware error (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check data cable(s) to enclosure. 2) Check if enclosure is running." --#STATE OPERATIONAL ::= 10330 -- EVT_ENCL_NOT_RESPONDING svrTrapEnclNotResponding TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure not responding." --#TYPE "Enclosure not responding" --#SUMMARY "Adapter %s: Enclosure %s not responding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check data cable(s) to enclosure. 2) Check if enclosure is running." --#STATE OPERATIONAL ::= 10331 -- EVT_ENCL_SAS_SATA_MIXING_DETECTED svrTrapEnclSASSATAMixingDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS/SATA mixing not supported in enclosure." --#TYPE "SAS/SATA mixing not supported in enclosure" --#SUMMARY "Adapter %s: SAS/SATA mixing not supported in enclosure; %s disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your disk configuration within enclosure." --#STATE OPERATIONAL ::= 10332 -- EVT_ENCL_SES_HOTPLUG_DETECTED svrTrapEnclSESHotplugDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure (SES) hotplug not supported." --#TYPE "Enclosure (SES) hotplug not supported" --#SUMMARY "Adapter %s: Enclosure (SES) hot plug on %s was detected, but is not supported (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10333 -- EVT_CLUSTER_ENABLED svrTrapClusterEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Clustering enabled." --#TYPE "Clustering enabled" --#SUMMARY "Adapter %s: Clustering enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10334 -- EVT_CLUSTER_DISABLED svrTrapClusterDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Clustering disabled." --#TYPE "Clustering disabled" --#SUMMARY "Adapter %s: Clustering disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10335 -- EVT_PD_TOO_SMALL_FOR_AUTO_REBUILD svrTrapPDTooSmallForAutoRebuild TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk too small to be used for auto-rebuild." --#TYPE "Disk too small to be used for auto-rebuild" --#SUMMARY "Adapter %s: Disk (%s) too small to be used for auto rebuild (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your disk configuration." --#STATE OPERATIONAL ::= 10336 -- EVT_BBU_GOOD svrTrapBBUGood TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU enabled; changing Write-through virtual disks to Write-back." --#TYPE "BBU enabled; changing Write-through virtual disks to Write-back" --#SUMMARY "Adapter %s: BBU enabled; changing Write-through logical drives to Write-back (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10337 -- EVT_BBU_BAD svrTrapBBUBad TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU disabled; changing Write-back virtual disks to Write-through." --#TYPE "BBU disabled; changing Write-back virtual disks to Write-through" --#SUMMARY "Adapter %s: BBU disabled; changing Write-back logical drives to Write-through (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Check connection between BBU data/power cable and RAID controller. 2) Check version of RAID controller/iRMC firmware, and BIOS. 3) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10338 -- EVT_PD_BBM_LOG_80_PERCENT_FULL svrTrapPDBBMLog80PercentFull TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table 80 percent full." --#TYPE "Bad block table 80 percent full" --#SUMMARY "Adapter %s: Bad block table on disk (%s) is 80 percent full (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10339 -- EVT_PD_BBM_LOG_FULL svrTrapPDBBMLogFull TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table full" --#TYPE "Bad block table full" --#SUMMARY "Adapter %s: Bad block table on disk (%s) is full; unable to log Block %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10340 -- EVT_LD_MDC_OWNERSHIP_LOSS_ABORT svrTrapLDMDCOwnershipLossAbort TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC aborted due to ownership loss." --#TYPE "MDC aborted due to ownership loss" --#SUMMARY "Adapter %s: MDC aborted due to ownership loss on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Restart consistency check (MDC)." --#STATE OPERATIONAL ::= 10341 -- EVT_LD_BGI_OWNERSHIP_LOSS_ABORT svrTrapLDBGIOwnershipLossAbort TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI aborted." --#TYPE "BGI aborted" --#SUMMARY "Adapter %s: BGI aborted due to ownership loss on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Restart Background initialization (BGI)." --#STATE OPERATIONAL ::= 10342 -- EVT_BBU_BATTERY_SOH_INVALID svrTrapBBUBatterySOHInvalid TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU/charger problems detected." --#TYPE "BBU/charger problems detected" --#SUMMARY "Adapter %s: BBU/charger problems detected; SOH bad (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace the BBU." --#STATE OPERATIONAL ::= 10343 -- EVT_CTRL_MEM_ECC_SINGLE_BIT_WARNING svrTrapCtrlMemECCSingleBitWarning TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Single-bit ECC error; warning threshold exceeded." --#TYPE "Single-bit ECC error; warning threshold exceeded" --#SUMMARY "Adapter %s: Single-bit ECC error: ECAR=%s, ELOG=%s, (%s); warning threshold exceeded (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "If the problem occurs repeatedly replace the RAID controller DIMM module (cache)." --#STATE OPERATIONAL ::= 10344 -- EVT_CTRL_MEM_ECC_SINGLE_BIT_CRITICAL svrTrapCtrlMemECCSingleBitCritical TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Single-bit ECC error; critical threshold exceeded." --#TYPE "Single-bit ECC error; critical threshold exceeded" --#SUMMARY "Adapter %s: Single-bit ECC error: ECAR=%s, ELOG=%s, (%s); critical threshold exceeded (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Replace the RAID controller DIMM module (cache). 2) If problem persists replace RAID controller." --#STATE OPERATIONAL ::= 10345 -- EVT_CTRL_MEM_ECC_SINGLE_BIT_DISABLED svrTrapCtrlMemECCSingleBitDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Single-bit ECC error: further reporting disabled." --#TYPE "Single-bit ECC error: further reporting disabled" --#SUMMARY "Adapter %s: Single-bit ECC error: ECAR=%s, ELOG=%s, (%s); further reporting disabled (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10346 -- EVT_ENCL_POWER_SUPPLY_CABLE_REMOVED svrTrapEnclPowerSupplyCableRemoved TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure power supply cable removed." --#TYPE "Enclosure power supply cable removed" --#SUMMARY "Adapter %s: Enclosure %s power supply %s cable removed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the enclosure power cable(s)." --#STATE OPERATIONAL ::= 10347 -- EVT_ENCL_POWER_SUPPLY_CABLE_INSERTED svrTrapEnclPowerSupplyCableInserted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure power supply cable inserted." --#TYPE "Enclosure power supply cable inserted" --#SUMMARY "Adapter %s: Enclosure %s power supply %s cable inserted (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10348 -- EVT_ENCL_FAN_RETURNED_TO_NORMAL svrTrapEnclFanReturnedToNormal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure fan returned to normal." --#TYPE "Enclosure fan returned to normal" --#SUMMARY "Adapter %s: Enclosure %s fan %s returned to normal (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10349 -- EVT_DIAG_BBU_RETENTION_TEST_STARTED_ON_PREV_BOOT svrTrapDiagBBURetentionTestStartedOnPrevReboot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU retention started on previous Boot." --#TYPE "BBU retention started on previous Boot" --#SUMMARY "Adapter %s: BBU retention started on previous boot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10350 -- EVT_DIAG_BBU_RETENTION_PASSED svrTrapDiagBBURetentionPassed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU retention test passed." --#TYPE "BBU retention test passed" --#SUMMARY "Adapter %s: BBU retention test passed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10351 -- EVT_DIAG_BAT_RETENTION_TEST_FAILED svrTrapDiagBatRetentionTestFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU retention test failed." --#TYPE "BBU retention test failed" --#SUMMARY "Adapter %s: BBU retention test failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Note: In general additional error messages should occur. If there are no other actions defined call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10352 -- EVT_DIAG_NVRAM_RET_TEST_STARTED_ON_PREV_BOOT svrTrapDiagNVRAMRetTestStartedOnPrevReboot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Retention test started on previous reboot." --#TYPE "Retention test started on previous reboot" --#SUMMARY "Adapter %s: Retention test started on previous reboot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10353 -- EVT_DIAG_NVRAM_RENTION_TEST_SUCCESS svrTrapDiagRetentionTestSuccess TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "NVRAM retention test passed." --#TYPE "NVRAM retention test passed" --#SUMMARY "Adapter %s: NVRAM retention test passed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10354 -- EVT_DIAG_NVRAM_RENTION_TEST_FAILED svrTrapDiagNVRAMRentionTestFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "NVRAM retention test failed." --#TYPE "NVRAM retention test failed" --#SUMMARY "Adapter %s: NVRAM retention test failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Note: In general additional error messages should occur. If there are no other actions defined call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10355 -- EVT_DIAG_SELF_CHECK_TEST_PASS svrTrapDiagSelfCheckTestPass TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Self check test finished successfully." --#TYPE "Self check test finished successfully" --#SUMMARY "Adapter %s: %s test finished %s passes successfully (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10356 -- EVT_DIAG_SELF_CHECK_TEST_FAIL svrTrapDiagSelfCheckTestFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Self check test failed." --#TYPE "Self check test failed" --#SUMMARY "Adapter %s: %s test failed on %s pass. fail data: errorOffset=%s goodData=%s badData=%s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 7, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Note: In general additional error messages should occur. If there are no other actions defined call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10357 -- EVT_DIAG_SELF_CHECK_DONE svrTrapDiagSelfCheckDone TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Self check diagnostics finished." --#TYPE "Self check diagnostics finished" --#SUMMARY "Adapter %s: Self-check diagnostics finished (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10358 -- EVT_FOREIGN_CFG_DETECTED svrTrapForeignCfgDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Foreign configuration detected." --#TYPE "Foreign configuration detected" --#SUMMARY "Adapter %s: Foreign configuration detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10359 -- EVT_FOREIGN_CFG_IMPORTED svrTrapForeignCfgImported TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Foreign configuration imported." --#TYPE "Foreign configuration imported" --#SUMMARY "Adapter %s: Foreign configuration imported (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10360 -- EVT_FOREIGN_CFG_CLEARED svrTrapForeignCfgCleared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Foreign configuration cleared." --#TYPE "Foreign configuration cleared" --#SUMMARY "Adapter %s: Foreign configuration cleared (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10361 -- EVT_NVRAM_CORRUPT svrTrapNVRAMCorrupt TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "NVRAM is corrupt; reinitializing." --#TYPE "NVRAM is corrupt; reinitializing" --#SUMMARY "Adapter %s: NVRAM is corrupt; reinitializing (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "If the problem occurs repeatedly replace the RAID controller." --#STATE OPERATIONAL ::= 10362 -- EVT_NVRAM_MISMATCH svrTrapNVRAMMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "NVRAM mismatch occurred." --#TYPE "NVRAM mismatch occurred" --#SUMMARY "Adapter %s: NVRAM mismatch occurred (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "If the problem occurs repeatedly replace the RAID controller." --#STATE OPERATIONAL ::= 10363 -- EVT_SAS_WIDE_PORT_LINK_LOST svrTrapSASWidePortLinkLost TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS wide port lost link on PHY." --#TYPE "SAS wide port lost link on PHY" --#SUMMARY "Adapter %s: SAS wide port %s lost link on PHY %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Unplug affected disk, wait 30 seconds, reinsert it. 2) Check/replace cable between controller and affected disk. 3) Check version of RAID controller/iRMC firmware, and BIOS. 4) Replace affected disk." --#STATE OPERATIONAL ::= 10364 -- EVT_SAS_WIDE_PORT_LINK_RESTORED svrTrapSASWidePortLinkRestored TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS wide port restored link on PHY." --#TYPE "SAS wide port restored link on PHY" --#SUMMARY "Adapter %s: SAS wide port %s restored link on PHY %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10365 -- EVT_SAS_PHY_ERROR_RATE_EXCEEDED svrTrapSASPhyErrorRateExceeded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS port has exceeded the allowed error rate." --#TYPE "SAS port has exceeded the allowed error rate" --#SUMMARY "Adapter %s: SAS port %s, PHY %s has exceeded the allowed error rate (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Disk reports errors. The affected disk might fail soon. 1) Replace the disk as soon as possible." --#STATE OPERATIONAL ::= 10366 -- EVT_SATA_BAD_BLOCK_REMAPED svrTrapSATABadBlockRemaped TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block reassigned." --#TYPE "Bad block reassigned" --#SUMMARY "Adapter %s: Bad block reassigned on disk (%s) from LBA %s to LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "If the problem occurs repeatedly replace the disk during next maintenance." --#STATE OPERATIONAL ::= 10367 -- EVT_CTRL_HOTPLUG_DETECTED svrTrapCtrlHotplugDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Controller hot plug detected." --#TYPE "Controller hot plug detected" --#SUMMARY "Adapter %s: Adapter hot plug detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10368 -- EVT_ENCL_TEMPERATURE_DIFFERENTIAL svrTrapEnclTemperatureDifferential TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure temperature sensor differential detected." --#TYPE "Enclosure temperature sensor differential detected" --#SUMMARY "Adapter %s: Enclosure %s temperature sensor %s differential detected (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10369 -- EVT_DIAG_DISK_TEST_CANNOT_START svrTrapDiagDiskTestCannotStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk test cannot start. No qualifying disks found." --#TYPE "Disk test cannot start. No qualifying disks found" --#SUMMARY "Adapter %s: Disk test cannot start. No qualifying disks found (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10370 -- EVT_DIAG_TIME_NOT_SUFFICIENT svrTrapDiagTimeNotSufficient TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Time duration provided by host is not sufficient for self-checking." --#TYPE "Time duration provided by host is not sufficient for self-checking" --#SUMMARY "Adapter %s: Time duration provided by host is not sufficient for self-checking (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10371 -- EVT_PD_MARK_MISSING svrTrapPDTMarkMissing TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Marked as missing." --#TYPE "Marked as missing" --#SUMMARY "Adapter %s: Disk (%s) on array %s row %s marked as missing (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10372 -- EVT_PD_REPLACE_MISSING svrTrapPDReplaceMissing TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Replaced missing." --#TYPE "Replaced missing" --#SUMMARY "Adapter %s: Disk (%s) replaced missing on array %s row %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10373 -- EVT_ENCL_TEMPERATURE_RETURNED_TO_NORMAL svrTrapEnclTemperatureReturnedToNormal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure temperature sensor returned to normal." --#TYPE "Enclosure temperature sensor returned to normal" --#SUMMARY "Adapter %s: Enclosure %s temperature sensor %s returned to normal (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10374 -- EVT_ENCL_FIRMWARE_FLASH_IN_PROGRESS svrTrapEnclFirmwareFlashInProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure firmware download in progress." --#TYPE "Enclosure firmware download in progress" --#SUMMARY "Adapter %s: Enclosure %s firmware download in progress (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10375 -- EVT_ENCL_FIRMWARE_DOWNLOAD_FAILED svrTrapEnclFirmwareDownloadFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure firmware download failed." --#TYPE "Enclosure firmware download failed" --#SUMMARY "Adapter %s: Enclosure %s firmware download failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10376 -- EVT_PD_NOT_CERTIFIED svrTrapPDNotCertified TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk is not certified." --#TYPE "Disk is not certified" --#SUMMARY "Adapter %s: Disk (%s) is not certified (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the type of your disk." --#STATE OPERATIONAL ::= 10377 -- EVT_CTRL_CACHE_DISCARD_BY_USER svrTrapCtrlCacheDiscardByUser TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Dirty cache data discarded by user." --#TYPE "Dirty cache data discarded by user" --#SUMMARY "Adapter %s: Dirty cache data discarded by user (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10378 -- EVT_CTRL_BOOT_MISSING_PDS svrTrapCtrlBootMissingPDs TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "PDs missing from configuration at boot." --#TYPE "PDs missing from configuration at boot" --#SUMMARY "Adapter %s: Disks missing from configuration at boot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your RAID configuration." --#STATE OPERATIONAL ::= 10379 -- EVT_CTRL_BOOT_LDS_WILL_GO_OFFLINE svrTrapCtrlBootLDsWillGoOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "VDs missing drives and will go offline at boot." --#TYPE "VDs missing drives and will go offline at boot" --#SUMMARY "Adapter %s: Logical drives missing drives and will go offline at boot: %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your RAID configuration." --#STATE OPERATIONAL ::= 10380 -- EVT_CTRL_BOOT_LDS_MISSING svrTrapCtrlBootLDsMissing TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "VDs missing at boot." --#TYPE "VDs missing at boot" --#SUMMARY "Adapter %s: Logical drives missing at boot: %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your RAID configuration." --#STATE OPERATIONAL ::= 10381 -- EVT_CTRL_BOOT_CONFIG_MISSING svrTrapCtrlBootConfigMissing TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Previous configuration completely missing at boot." --#TYPE "Previous configuration completely missing at boot" --#SUMMARY "Adapter %s: Previous configuration completely missing at boot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your RAID configuration." --#STATE OPERATIONAL ::= 10382 -- EVT_BBU_CHARGE_COMPLETE svrTrapBBUChargeComplete TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU charging complete." --#TYPE "BBU charging complete" --#SUMMARY "Adapter %s: BBU charging complete (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10383 -- EVT_ENCL_FAN_SPEED_CHANGED svrTrapEnclFanSpeedChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure fan speed changed." --#TYPE "Enclosure fan speed changed" --#SUMMARY "Adapter %s: Enclosure %s fan %s speed changed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10384 -- EVT_PD_SPARE_DEDICATED_IMPORTED_AS_GLOBAL svrTrapPDSpareDedicatedImportedAsGlobal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Dedicated spare imported as global due to missing arrays." --#TYPE "Dedicated spare imported as global due to missing arrays" --#SUMMARY "Adapter %s: Dedicated hot spare (%s) imported as global due to missing arrays (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10385 -- EVT_PD_NO_REBUILD_SAS_SATA_MIX_NOT_ALLOWED_IN_LD svrTrapPDNoRebuildSASSATAMixNotAllowedInLD TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk rebuild not possible as SAS/SATA mixing is not supported in an array." --#TYPE "Disk rebuild not possible as SAS/SATA mixing is not supported in an array" --#SUMMARY "Adapter %s: Disk (%s) rebuild not possible as SAS/SATA mixing is not supported in an array (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10386 -- EVT_SEP_IS_BEING_REBOOTED svrTrapSEPIsBeingRebooted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "I/O module has been rebooted as part of enclosure firmware download." --#TYPE "I/O module has been rebooted as part of enclosure firmware download" --#SUMMARY "Adapter %s: I/O module %s has been rebooted as part of enclosure firmware download. It will be unavailable until reboot completes (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10387 -- EVT_LD_PARTIALLY_DEGRADED svrTrapLDPartiallyDegraded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is partially degraded." --#TYPE "Logical drive is partially degraded" --#SUMMARY "Adapter %s: Logical drive %s partially degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE DEGRADED ::= 10388 -- EVT_BBU_RELEARN_REQUESTED svrTrapBBURelearnRequested TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU requires reconditioning." --#TYPE "BBU requires reconditioning" --#SUMMARY "Adapter %s: BBU requires reconditioning; please initiate a LEARN cycle (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10389 -- EVT_COERCION_MODE_CHANGED svrTrapCoercionModeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Coercion mode changed." --#TYPE "Coercion mode changed" --#SUMMARY "Adapter %s: Coercion mode changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10390 -- EVT_BBU_AUTO_LEARN_MODE_CHANGED svrTrapBBUAutoLearnModeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU automatic Learn mode changed." --#TYPE "BBU automatic Learn mode changed" --#SUMMARY "Adapter %s: BBU automatic learn mode changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10391 -- EVT_BBU_AUTO_LEARN_PERIOD_CHANGED svrTrapBBUAutoModeLearnPeriodChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU automatic learn period changed." --#TYPE "BBU automatic learn period changed" --#SUMMARY "Adapter %s: BBU automatic learn period changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10392 -- EVT_BBU_LEARN_DELAY_INTERVAL_CHANGED svrTrapBBULearnDelayIntervalChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU learn delay interval changed." --#TYPE "BBU learn delay interval changed" --#SUMMARY "Adapter %s: BBU learn delay interval changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10393 -- EVT_BBU_NEXT_LEARN_TIME_CHANGED svrTrapBBUNextLearnTimeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU next learn time changed." --#TYPE "BBU next learn time changed" --#SUMMARY "Adapter %s: BBU next learn time changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10394 -- EVT_PATROLREAD_MAXPD_CHANGED svrTrapPatrolreadMaxPDChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Max. disk count for Patrol Read changed." --#TYPE "Max. disk count for Patrol Read changed" --#SUMMARY "Adapter %s: Max. disk count for Patrol Read changed to %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10395 -- EVT_PATROLREAD_CONTINUOUS_PATROLLING_ENABLED svrTrapPatrolreadContinuousPatrollingEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Continuous patrolling enabled." --#TYPE "Continuous patrolling enabled" --#SUMMARY "Adapter %s: Continuous patrolling enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10396 -- EVT_PATROLREAD_CONTINUOUS_PATROLLING_DISABLED svrTrapPatrolreadContinousPatrollingDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Continuous patrolling disabled." --#TYPE "Continuous patrolling disabled" --#SUMMARY "Adapter %s: Continuous patrolling disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10397 -- EVT_MDC_ERROR svrTrapLDMDCFinishedWithErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC finished with errors on logical drive." --#TYPE "MDC finished with errors on logical drive" --#SUMMARY "Adapter %s: MDC finished with errors on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Manually initiate second consistency check (MDC). 2) If problem persists replace affected disk." --#STATE OPERATIONAL ::= 10398 -- EVT_LD_DISABLED_NO_SUPPORT_FOR_RAID5 svrTrapLDDisabledNoSupportForRAID5 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive disabled because RAID-5 not supported." --#TYPE "Logical drive disabled because RAID-5 not supported" --#SUMMARY "Adapter %s: Logical drive %s disabled because RAID-5 is not supported by this RAID key (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10399 -- EVT_LD_DISABLED_NO_SUPPORT_FOR_RAID6 svrTrapLDDisabledNoSupportForRAID6 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive disabled because RAID-6 not supported." --#TYPE "Logical drive disabled because RAID-6 not supported" --#SUMMARY "Adapter %s: Logical drive %s disabled because RAID-6 is not supported by this RAID key (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10400 -- EVT_LD_DISABLED_NO_SUPPORT_FOR_SAS svrTrapLDDisabledNoSupportForSAS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive disabled because SAS drives not supported." --#TYPE "Logical drive disabled because SAS drives not supported" --#SUMMARY "Adapter %s: Logical drive %s disabled because SAS drives are not supported by this RAID key (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the disks." --#STATE OPERATIONAL ::= 10401 -- EVT_CTRL_BOOT_MISSING_PDS_EXT svrTrapCtrlBootMissingPDsExt TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disks missing." --#TYPE "Disks missing" --#SUMMARY "Adapter %s: Disks missing (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your RAID configuration." --#STATE OPERATIONAL ::= 10402 -- EVT_REBUILD_RATE_CHANGED_EX svrTrapAdapterRebuildRateChangedEx TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild rate changed." --#TYPE "Rebuild rate changed" --#SUMMARY "Adapter %s: Rebuild rate changed to %s percent (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10403 -- EVT_CHECK_RATE_CHANGED_EX svrTrapAdapterConCheckRateChangedEx TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check rate changed." --#TYPE "Consistency check rate changed" --#SUMMARY "Adapter %s: Consistency check rate changed to %s percent (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10404 -- EVT_SMART_POLL_INTERVAL_CHANGED_EX svrTrapAdapterSMARTPollIntervalChangedEx TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SMART poll interval changed." --#TYPE "SMART poll interval changed" --#SUMMARY "Adapter %s: SMART poll interval changed to %s s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10405 -- EVT_MDC_STARTED svrTrapLDMDCStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC started on logical drive." --#TYPE "MDC started on logical drive" --#SUMMARY "Adapter %s: MDC started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10406 -- EVT_MDC_FINISHED svrTrapLDMDCFinished TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC finished on logical drive." --#TYPE "MDC finished on logical drive" --#SUMMARY "Adapter %s: MDC finished on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10407 -- EVT_MDC_FAILED svrTrapLDMDCFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC failed on logical drive." --#TYPE "MDC failed on logical drive" --#SUMMARY "Adapter %s: MDC failed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Manually initiate second consistency check (MDC). 2) If problem persists replace affected disk." --#STATE OPERATIONAL ::= 10408 -- EVT_MDC_CANCELED svrTrapLDMDCAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC aborted on logical drive." --#TYPE "MDC aborted on logical drive" --#SUMMARY "Adapter %s: MDC aborted on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10409 -- EVT_MDC_PAUSED svrTrapLDMDCPaused TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC suspended on logical drive." --#TYPE "MDC suspended on logical drive" --#SUMMARY "Adapter %s: MDC suspended on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10410 -- EVT_MDC_STARTED_UNINITIALIZED svrTrapLDUninitialisedMDCStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC started on uninitialized logical drive." --#TYPE "MDC started on uninitialized logical drive" --#SUMMARY "Adapter %s: MDC started on uninitialized logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10411 -- EVT_LD_STATE_CHANGE_OP_TO_DEG svrTrapLDStateChangedOpToDeg TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to degraded." --#TYPE "State change from operational to degraded" --#SUMMARY "Adapter %s: State change on logical drive %s from operational to degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE DEGRADED ::= 10412 -- EVT_LD_STATE_CHANGE_OP_TO_PAR_DEG svrTrapLDStateChangedOpToParDeg TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to partially degraded." --#TYPE "State change from operational to partially degraded" --#SUMMARY "Adapter %s: State change on logical drive %s from operational to partially degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE DEGRADED ::= 10413 -- EVT_LD_STATE_CHANGE_OP_TO_FAIL svrTrapLDStateChangedOpToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to failed." --#TYPE "State change from operational to failed" --#SUMMARY "Adapter %s: State change on logical drive %s from operational to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Check version of RAID controller/iRMC firmware, and BIOS." --#STATE NONOPERATIONAL ::= 10414 -- EVT_LD_STATE_CHANGE_DEG_TO_OP svrTrapLDStateChangedDegToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from degraded to operational." --#TYPE "State change from degraded to operational" --#SUMMARY "Adapter %s: State change on logical drive %s from degraded to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10415 -- EVT_LD_STATE_CHANGE_DEG_TO_DEG svrTrapLDStateChangedDegToDeg TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from degraded to degraded." --#TYPE "State change from degraded to degraded" --#SUMMARY "Adapter %s: State change on logical drive %s from degraded to degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE DEGRADED ::= 10416 -- EVT_LD_STATE_CHANGE_DEG_TO_PAR_DEG svrTrapLDStateChangedDegToParDeg TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from degraded to partially degraded." --#TYPE "State change from degraded to partially degraded" --#SUMMARY "Adapter %s: State change on logical drive %s from degraded to partially degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10417 -- EVT_LD_STATE_CHANGE_DEG_TO_FAIL svrTrapLDStateChangedDegToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from degraded to failed." --#TYPE "State change from degraded to failed" --#SUMMARY "Adapter %s: State change on logical drive %s from degraded to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Replace affected disks. 2) The array has to be recreated. Note: Data loss is probable." --#STATE NONOPERATIONAL ::= 10418 -- EVT_LD_STATE_CHANGE_PAR_DEG_TO_OP svrTrapLDStateChangedParDegToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from partially degraded to operational." --#TYPE "State change from partially degraded to operational" --#SUMMARY "Adapter %s: State change on logical drive %s from partially degraded to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10419 -- EVT_LD_STATE_CHANGE_PAR_DEG_TO_DEG svrTrapLDStateChangedParDegToDeg TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from partially degraded to degraded." --#TYPE "State change from partially degraded to degraded" --#SUMMARY "Adapter %s: State change on logical drive %s from partially degraded to degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE DEGRADED ::= 10420 -- EVT_LD_STATE_CHANGE_PAR_DEG_TO_PAR_DEG svrTrapLDStateChangedParDegToParDeg TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from partially degraded to partially degraded." --#TYPE "State change from partially degraded to partially degraded" --#SUMMARY "Adapter %s: State change on logical drive %s from partially degraded to partially degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE DEGRADED ::= 10421 -- EVT_LD_STATE_CHANGE_PAR_DEG_TO_FAIL svrTrapLDStateChangedParDegToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from partially degraded to failed." --#TYPE "State change from partially degraded to failed" --#SUMMARY "Adapter %s: State change on logical drive %s from partially degraded to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Replace affected disks. 2) The array has to be recreated. Note: Data loss is probable." --#STATE NONOPERATIONAL ::= 10422 -- EVT_LD_STATE_CHANGE_FAIL_TO_OP svrTrapLDStateChangedFailToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to operational." --#TYPE "State change from failed to operational" --#SUMMARY "Adapter %s: State change on logical drive %s from failed to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10423 -- EVT_LD_STATE_CHANGE_FAIL_TO_DEG svrTrapLDStateChangedFailToDeg TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to degraded." --#TYPE "State change from failed to degraded" --#SUMMARY "Adapter %s: State change on logical drive %s from failed to degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10424 -- EVT_LD_STATE_CHANGE_FAIL_TO_PAR_DEG svrTrapLDStateChangedFailToParDeg TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to partially degraded." --#TYPE "State change from failed to partially degraded" --#SUMMARY "Adapter %s: State change on logical drive %s from failed to partially degraded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10425 -- EVT_LD_STATE_CHANGE_FAIL_TO_FAIL svrTrapLDStateChangedFailToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to failed." --#TYPE "State change from failed to failed" --#SUMMARY "Adapter %s: State change on logical drive %s from failed to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 10426 -- EVT_PD_STATE_CHANGE_BY_USER_AVAIL_TO_FAIL svrTrapPDStateChangeByUserAvailToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from available to failed." --#TYPE "State change by user from available to failed" --#SUMMARY "Adapter %s: State change by user on disk (%s) from available to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE NONOPERATIONAL ::= 10427 -- EVT_PD_STATE_CHANGE_BY_USER_AVAIL_TO_HS svrTrapPDStateChangeByUserAvailToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from available to hot spare." --#TYPE "State change by user from available to hot spare" --#SUMMARY "Adapter %s: State change by user on disk (%s) from available to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10428 -- EVT_PD_STATE_CHANGE_BY_USER_AVAIL_TO_RBLD svrTrapPDStateChangeByUserAvailToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from available to rebuilding." --#TYPE "State change by user from available to rebuilding" --#SUMMARY "Adapter %s: State change by user on disk (%s) from available to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10429 -- EVT_PD_STATE_CHANGE_BY_USER_AVAIL_TO_OP svrTrapPDStateChangeByUserAvailToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from available to operational." --#TYPE "State change by user from available to operational" --#SUMMARY "Adapter %s: State change by user on disk (%s) from available to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10430 -- EVT_PD_STATE_CHANGE_BY_USER_FAIL_TO_AVAIL svrTrapPDStateChangeByUserFailToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from failed to available." --#TYPE "State change by user from failed to available" --#SUMMARY "Adapter %s: State change by user on disk (%s) from failed to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10431 -- EVT_PD_STATE_CHANGE_BY_USER_FAIL_TO_FAIL svrTrapPDStateChangeByUserFailToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from failed to failed." --#TYPE "State change by user from failed to failed" --#SUMMARY "Adapter %s: State change by user on disk (%s) from failed to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE NONOPERATIONAL ::= 10432 -- EVT_PD_STATE_CHANGE_BY_USER_FAIL_TO_HS svrTrapPDStateChangeByUserFailToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from failed to hot spare." --#TYPE "State change by user from failed to hot spare" --#SUMMARY "Adapter %s: State change by user on disk (%s) from failed to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10433 -- EVT_PD_STATE_CHANGE_BY_USER_FAIL_TO_RBLD svrTrapPDStateChangeByUserFailToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from failed to rebuilding." --#TYPE "State change by user from failed to rebuilding" --#SUMMARY "Adapter %s: State change by user on disk (%s) from failed to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10434 -- EVT_PD_STATE_CHANGE_BY_USER_FAIL_TO_OP svrTrapPDStateChangeByUserFailToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from failed to operational." --#TYPE "State change by user from failed to operational" --#SUMMARY "Adapter %s: State change by user on disk (%s) from failed to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10435 -- EVT_PD_STATE_CHANGE_BY_USER_HS_TO_AVAIL svrTrapPDStateChangeByUserHSToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from hot spare to available." --#TYPE "State change by user from hot spare to available" --#SUMMARY "Adapter %s: State change by user on disk (%s) from hot spare to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10436 -- EVT_PD_STATE_CHANGE_BY_USER_HS_TO_FAIL svrTrapPDStateChangeByUserHSToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from hot spare to failed." --#TYPE "State change by user from hot spare to failed" --#SUMMARY "Adapter %s: State change by user on disk (%s) from hot spare to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE NONOPERATIONAL ::= 10437 -- EVT_PD_STATE_CHANGE_BY_USER_HS_TO_HS svrTrapPDStateChangeByUserHSToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from hot spare to hot spare." --#TYPE "State change by user from hot spare to hot spare" --#SUMMARY "Adapter %s: State change by user on disk (%s) from hot spare to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10438 -- EVT_PD_STATE_CHANGE_BY_USER_HS_TO_RBLD svrTrapPDStateChangeByUserHSToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from hot spare to rebuilding." --#TYPE "State change by user from hot spare to rebuilding" --#SUMMARY "Adapter %s: State change by user on disk (%s) from hot spare to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10439 -- EVT_PD_STATE_CHANGE_BY_USER_HS_TO_OP svrTrapPDStateChangeByUserHSToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from hot spare to operational." --#TYPE "State change by user from hot spare to operational" --#SUMMARY "Adapter %s: State change by user on disk (%s) from hot spare to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10440 -- EVT_PD_STATE_CHANGE_BY_USER_RBLD_TO_AVAIL svrTrapPDStateChangeByUserRbldToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from rebuilding to available." --#TYPE "State change by user from rebuilding to available" --#SUMMARY "Adapter %s: State change by user on disk (%s) from rebuilding to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10441 -- EVT_PD_STATE_CHANGE_BY_USER_RBLD_TO_FAIL svrTrapPDStateChangeByUserRbldToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from rebuilding to failed." --#TYPE "State change by user from rebuilding to failed" --#SUMMARY "Adapter %s: State change by user on disk (%s) from rebuilding to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE NONOPERATIONAL ::= 10442 -- EVT_PD_STATE_CHANGE_BY_USER_RBLD_TO_HS svrTrapPDStateChangeByUserRbldToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from rebuilding to hot spare." --#TYPE "State change by user from rebuilding to hot spare" --#SUMMARY "Adapter %s: State change by user on disk (%s) from rebuilding to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10443 -- EVT_PD_STATE_CHANGE_BY_USER_RBLD_TO_RBLD svrTrapPDStateChangeByUserRbldToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from rebuilding to rebuilding." --#TYPE "State change by user from rebuilding to rebuilding" --#SUMMARY "Adapter %s: State change by user on disk (%s) from rebuilding to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10444 -- EVT_PD_STATE_CHANGE_BY_USER_RBLD_TO_OP svrTrapPDStateChangeByUserRbldToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from rebuilding to operational." --#TYPE "State change by user from rebuilding to operational" --#SUMMARY "Adapter %s: State change by user on disk (%s) from rebuilding to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10445 -- EVT_PD_STATE_CHANGE_BY_USER_OP_TO_AVAIL svrTrapPDStateChangeByUserOpToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from operational to available." --#TYPE "State change by user from operational to available" --#SUMMARY "Adapter %s: State change by user on disk (%s) from operational to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10446 -- EVT_PD_STATE_CHANGE_BY_USER_OP_TO_FAIL svrTrapPDStateChangeByUserOpToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from operational to failed." --#TYPE "State change by user from operational to failed" --#SUMMARY "Adapter %s: State change by user on disk (%s) from operational to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE NONOPERATIONAL ::= 10447 -- EVT_PD_STATE_CHANGE_BY_USER_OP_TO_HS svrTrapPDStateChangeByUserOpToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from operational to hot spare." --#TYPE "State change by user from operational to hot spare" --#SUMMARY "Adapter %s: State change by user on disk (%s) from operational to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10448 -- EVT_PD_STATE_CHANGE_BY_USER_OP_TO_RBLD svrTrapPDStateChangeByUserOpToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from operational to rebuilding." --#TYPE "State change by user from operational to rebuilding" --#SUMMARY "Adapter %s: State change by user on disk (%s) from operational to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10449 -- EVT_PD_STATE_CHANGE_BY_USER_OP_TO_OP svrTrapPDStateChangeByUserOpToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from operational to operational." --#TYPE "State change by user from operational to operational" --#SUMMARY "Adapter %s: State change by user on disk (%s) from operational to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10450 -- EVT_PD_STATE_CHANGE_AVAIL_TO_FAIL svrTrapPDStateChangeAvailToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from available to failed." --#TYPE "State change from available to failed" --#SUMMARY "Adapter %s: State change on disk (%s) from available to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10451 -- EVT_PD_STATE_CHANGE_AVAIL_TO_HS svrTrapPDStateChangeAvailToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from available to hot spare." --#TYPE "State change from available to hot spare" --#SUMMARY "Adapter %s: State change on disk (%s) from available to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10452 -- EVT_PD_STATE_CHANGE_AVAIL_TO_RBLD svrTrapPDStateChangeAvailToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from available to rebuilding." --#TYPE "State change from available to rebuilding" --#SUMMARY "Adapter %s: State change on disk (%s) from available to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10453 -- EVT_PD_STATE_CHANGE_AVAIL_TO_OP svrTrapPDStateChangeAvailToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from available to operational." --#TYPE "State change from available to operational" --#SUMMARY "Adapter %s: State change on disk (%s) from available to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10454 -- EVT_PD_STATE_CHANGE_FAIL_TO_AVAIL svrTrapPDStateChangeFailToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to available." --#TYPE "State change from failed to available" --#SUMMARY "Adapter %s: State change on disk (%s) from failed to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10455 -- EVT_PD_STATE_CHANGE_FAIL_TO_FAIL svrTrapPDStateChangeFailToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to failed." --#TYPE "State change from failed to failed" --#SUMMARY "Adapter %s: State change on disk (%s) from failed to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 10456 -- EVT_PD_STATE_CHANGE_FAIL_TO_HS svrTrapPDStateChangeFailToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to hot spare." --#TYPE "State change from failed to hot spare" --#SUMMARY "Adapter %s: State change on disk (%s) from failed to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10457 -- EVT_PD_STATE_CHANGE_FAIL_TO_RBLD svrTrapPDStateChangeFailToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to rebuilding." --#TYPE "State change from failed to rebuilding" --#SUMMARY "Adapter %s: State change on disk (%s) from failed to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10458 -- EVT_PD_STATE_CHANGE_FAIL_TO_OP svrTrapPDStateChangeFailToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to operational." --#TYPE "State change from failed to operational" --#SUMMARY "Adapter %s: State change on disk (%s) from failed to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10459 -- EVT_PD_STATE_CHANGE_HS_TO_AVAIL svrTrapPDStateChangeHSToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from hot spare to available." --#TYPE "State change from hot spare to available" --#SUMMARY "Adapter %s: State change on disk (%s) from hot spare to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10460 -- EVT_PD_STATE_CHANGE_HS_TO_FAIL svrTrapPDStateChangeHSToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from hot spare to failed." --#TYPE "State change from hot spare to failed" --#SUMMARY "Adapter %s: State change on disk (%s) from hot spare to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10461 -- EVT_PD_STATE_CHANGE_HS_TO_HS svrTrapPDStateChangeHSToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from hot spare to hot spare." --#TYPE "State change from hot spare to hot spare" --#SUMMARY "Adapter %s: State change on disk (%s) from hot spare to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10462 -- EVT_PD_STATE_CHANGE_HS_TO_RBLD svrTrapPDStateChangeHSToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from hot spare to rebuilding." --#TYPE "State change from hot spare to rebuilding" --#SUMMARY "Adapter %s: State change on disk (%s) from hot spare to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10463 -- EVT_PD_STATE_CHANGE_HS_TO_OP svrTrapPDStateChangeHSToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from hot spare to operational." --#TYPE "State change from hot spare to operational" --#SUMMARY "Adapter %s: State change on disk (%s) from hot spare to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10464 -- EVT_PD_STATE_CHANGE_RBLD_TO_AVAIL svrTrapPDStateChangeRbldToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from rebuilding to available." --#TYPE "State change from rebuilding to available" --#SUMMARY "Adapter %s: State change on disk (%s) from rebuilding to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10465 -- EVT_PD_STATE_CHANGE_RBLD_TO_FAIL svrTrapPDStateChangeRbldToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from rebuilding to failed." --#TYPE "State change from rebuilding to failed" --#SUMMARY "Adapter %s: State change on disk (%s) from rebuilding to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Manually initiate a second rebuild (e.g. via ServerView RAID Manager). 2) If problem persists replace affected disk." --#STATE NONOPERATIONAL ::= 10466 -- EVT_PD_STATE_CHANGE_RBLD_TO_HS svrTrapPDStateChangeRbldToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from rebuilding to hot spare." --#TYPE "State change from rebuilding to hot spare" --#SUMMARY "Adapter %s: State change on disk (%s) from rebuilding to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10467 -- EVT_PD_STATE_CHANGE_RBLD_TO_RBLD svrTrapPDStateChangeRbldToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from rebuilding to rebuilding." --#TYPE "State change from rebuilding to rebuilding" --#SUMMARY "Adapter %s: State change on disk (%s) from rebuilding to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10468 -- EVT_PD_STATE_CHANGE_RBLD_TO_OP svrTrapPDStateChangeRbldToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from rebuilding to operational." --#TYPE "State change from rebuilding to operational" --#SUMMARY "Adapter %s: State change on disk (%s) from rebuilding to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10469 -- EVT_PD_STATE_CHANGE_OP_TO_AVAIL svrTrapPDStateChangeOpToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to available." --#TYPE "State change from operational to available" --#SUMMARY "Adapter %s: State change on disk (%s) from operational to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10470 -- EVT_PD_STATE_CHANGE_OP_TO_FAIL svrTrapPDStateChangeOpToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to failed." --#TYPE "State change from operational to failed" --#SUMMARY "Adapter %s: State change on disk (%s) from operational to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10471 -- EVT_PD_STATE_CHANGE_OP_TO_HS svrTrapPDStateChangeOpToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to hot spare." --#TYPE "State change from operational to hot spare" --#SUMMARY "Adapter %s: State change on disk (%s) from operational to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10472 -- EVT_PD_STATE_CHANGE_OP_TO_RBLD svrTrapPDStateChangeOpToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to rebuilding." --#TYPE "State change from operational to rebuilding" --#SUMMARY "Adapter %s: State change on disk (%s) from operational to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10473 -- EVT_PD_STATE_CHANGE_OP_TO_OP svrTrapPDStateChangeOpToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to operational." --#TYPE "State change from operational to operational" --#SUMMARY "Adapter %s: State change on disk (%s) from operational to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10474 -- EVT_MDC_DOUBLE_MEDIUM_ERRORS_DETECTED svrTrapLDMDCDoubleMediumErrorsDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC detected uncorrectable multiple medium errors on logical drive." --#TYPE "MDC detected uncorrectable multiple medium errors on logical drive" --#SUMMARY "Adapter %s: MDC detected uncorrectable multiple medium errors (disk (%s) at LBA %s on logical drive %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10475 -- EVT_PD_MISSING_AFTER_REBOOT svrTrapPDMissingAfterReboot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk missing after reboot." --#TYPE "Disk missing after reboot" --#SUMMARY "Adapter %s: Disk (%s) missing after reboot (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check your RAID configuration." --#STATE OPERATIONAL ::= 10476 -- EVT_LD_MISSING_AFTER_REBOOT svrTrapLDMissingAfterReboot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive missing after reboot." --#TYPE "Logical drive missing after reboot" --#SUMMARY "Adapter %s: Logical drive %s missing after reboot (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check your RAID configuration." --#STATE OPERATIONAL ::= 10477 -- EVT_PD_APPEARED_AFTER_REBOOT svrTrapPDAppearedAfterReboot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk appeared new after reboot." --#TYPE "Disk appeared new after reboot" --#SUMMARY "Adapter %s: Disk (%s) appeared new after reboot (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10478 -- EVT_LD_APPEARED_AFTER_REBOOT svrTrapLDAppearedAfterReboot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive appeared new after reboot." --#TYPE "Logical drive appeared new after reboot" --#SUMMARY "Adapter %s: Logical drive %s appeared new after reboot (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10479 -- EVT_CTRL_PUNCTURE_ENABLED svrTrapCtrlPunctureEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Puncture enabled." --#TYPE "Puncture enabled" --#SUMMARY "Adapter %s: Puncturing of LBAs enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10480 -- EVT_CTRL_PUNCTURE_DISABLED svrTrapCtrlPunctureDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Puncture disabled." --#TYPE "Puncture disabled" --#SUMMARY "Adapter %s: Puncturing of LBAs disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10481 -- EVT_ENCL_SIM_NOT_INSTALLED svrTrapEnclSimNotInstalled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure I/O module not installed." --#TYPE "Enclosure I/O module not installed" --#SUMMARY "Adapter %s: Enclosure %s I/O module %s not installed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10482 -- EVT_PACKAGE_VERSION svrTrapPackageVersion TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Package version." --#TYPE "Package version" --#SUMMARY "Adapter %s: Package version %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10483 -- EVT_LD_MV_CORRECTED_MEDIUM_ERROR svrTrapLDMVCorrectedMediumError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Media verification corrected error." --#TYPE "Media verification corrected error" --#SUMMARY "Adapter %s: Media verification corrected error (logical drive %s at LBA %s on disk (%s) at LBA %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10484 -- EVT_PD_STATE_CHANGE_AVAIL_TO_OFFL svrTrapPDStateChangeAvailToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from available to offline." --#TYPE "State change from available to offline" --#SUMMARY "Adapter %s: State change on disk (%s) from available to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10485 -- EVT_PD_STATE_CHANGE_BY_USER_AVAIL_TO_OFFL svrTrapPDStateChangeByUserAvailToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from available to offline." --#TYPE "State change by user from available to offline" --#SUMMARY "Adapter %s: State change by user on disk (%s) from available to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10486 -- EVT_PD_STATE_CHANGE_BY_USER_FAIL_TO_OFFL svrTrapPDStateChangeByUserFailToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from failed to offline." --#TYPE "State change by user from failed to offline" --#SUMMARY "Adapter %s: State change by user on disk (%s) from failed to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10487 -- EVT_PD_STATE_CHANGE_BY_USER_HS_TO_OFFL svrTrapPDStateChangeByUserHotspareToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from hot spare to offline." --#TYPE "State change by user from hot spare to offline" --#SUMMARY "Adapter %s: State change by user on disk (%s) from hot spare to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10488 -- EVT_PD_STATE_CHANGE_BY_USER_OFFL_TO_AVAIL svrTrapPDStateChangeByUserOfflineToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from offline to available." --#TYPE "State change by user from offline to available" --#SUMMARY "Adapter %s: State change by user on disk (%s) from offline to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10489 -- EVT_PD_STATE_CHANGE_BY_USER_OFFL_TO_FAIL svrTrapPDStateChangeByUserOfflineToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from offline to failed." --#TYPE "State change by user from offline to failed" --#SUMMARY "Adapter %s: State change by user on disk (%s) from offline to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE NONOPERATIONAL ::= 10490 -- EVT_PD_STATE_CHANGE_BY_USER_OFFL_TO_HS svrTrapPDStateChangeByUserOfflineToHotspare TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from offline to hot spare." --#TYPE "State change by user from offline to hot spare" --#SUMMARY "Adapter %s: State change by user on disk (%s) from offline to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10491 -- EVT_PD_STATE_CHANGE_BY_USER_OFFL_TO_OFFL svrTrapPDStateChangeByUserOfflineToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from offline to offline." --#TYPE "State change by user from offline to offline" --#SUMMARY "Adapter %s: State change by user on disk (%s) from offline to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10492 -- EVT_PD_STATE_CHANGE_BY_USER_OFFL_TO_OP svrTrapPDStateChangeByUserOfflineToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from offline to operational." --#TYPE "State change by user from offline to operational" --#SUMMARY "Adapter %s: State change by user on disk (%s) from offline to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10493 -- EVT_PD_STATE_CHANGE_BY_USER_OFFL_TO_RBLD svrTrapPDStateChangeByUserOfflineToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from offline to rebuilding." --#TYPE "State change by user from offline to rebuilding" --#SUMMARY "Adapter %s: State change by user on disk (%s) from offline to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10494 -- EVT_PD_STATE_CHANGE_BY_USER_OP_TO_OFFL svrTrapPDStateChangeByUserOpToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from operational to offline." --#TYPE "State change by user from operational to offline" --#SUMMARY "Adapter %s: State change by user on disk (%s) from operational to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10495 -- EVT_PD_STATE_CHANGE_BY_USER_RBLD_TO_OFFL svrTrapPDStateChangeByUserRbldToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from rebuilding to offline." --#TYPE "State change by user from rebuilding to offline" --#SUMMARY "Adapter %s: State change by user on disk (%s) from rebuilding to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10496 -- EVT_PD_STATE_CHANGE_FAIL_TO_OFFL svrTrapPDStateChangeFailToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to offline." --#TYPE "State change from failed to offline" --#SUMMARY "Adapter %s: State change on disk (%s) from failed to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10497 -- EVT_PD_STATE_CHANGE_HS_TO_OFFL svrTrapPDStateChangeHSToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from hot spare to offline." --#TYPE "State change from hot spare to offline" --#SUMMARY "Adapter %s: State change on disk (%s) from hot spare to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Manually set the disk to hot spare again (e.g. via ServerView RAID Manager). 2) If problem persists replace affected disk." --#STATE NONOPERATIONAL ::= 10498 -- EVT_PD_STATE_CHANGE_OFFL_TO_AVAIL svrTrapPDStateChangeOfflineToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from offline to available." --#TYPE "State change from offline to available" --#SUMMARY "Adapter %s: State change on disk (%s) from offline to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10499 -- EVT_PD_STATE_CHANGE_OFFL_TO_FAIL svrTrapPDStateChangeOfflineToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from offline to failed." --#TYPE "State change from offline to failed" --#SUMMARY "Adapter %s: State change on disk (%s) from offline to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10500 -- EVT_PD_STATE_CHANGE_OFFL_TO_HS svrTrapPDStateChangeOfflineToHS TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from offline to hot spare." --#TYPE "State change from offline to hot spare" --#SUMMARY "Adapter %s: State change on disk (%s) from offline to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10501 -- EVT_PD_STATE_CHANGE_OFFL_TO_OFFL svrTrapPDStateChangeOfflineToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from offline to offline." --#TYPE "State change from offline to offline" --#SUMMARY "Adapter %s: State change on disk (%s) from offline to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10502 -- EVT_PD_STATE_CHANGE_OFFL_TO_OP svrTrapPDStateChangeOfflineToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from offline to operational." --#TYPE "State change from offline to operational" --#SUMMARY "Adapter %s: State change on disk (%s) from offline to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10503 -- EVT_PD_STATE_CHANGE_OFFL_TO_RBLD svrTrapPDStateChangeOfflineToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from offline to rebuilding." --#TYPE "State change from offline to rebuilding" --#SUMMARY "Adapter %s: State change on disk (%s) from offline to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10504 -- EVT_PD_STATE_CHANGE_OP_TO_OFFL svrTrapPDStateChangeOpToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to offline." --#TYPE "State change from operational to offline" --#SUMMARY "Adapter %s: State change on disk (%s) from operational to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Only informational if status change was forced by user otherwise: 1) Replace affected disk." --#STATE DEGRADED ::= 10505 -- EVT_PD_STATE_CHANGE_RBLD_TO_OFFL svrTrapPDStateChangeRbldToOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from rebuilding to offline." --#TYPE "State change from rebuilding to offline" --#SUMMARY "Adapter %s: State change on disk (%s) from rebuilding to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Only informational if status change was forced by user otherwise: 1) Replace affected disk." --#STATE DEGRADED ::= 10506 -- EVT_CACHE_FLUSHED svrTrapCacheFlushed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Data in cache flushed during power up." --#TYPE "Data in cache flushed during power up" --#SUMMARY "Adapter %s: Data in cache flushed during power up (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10507 -- EVT_CACHE_NOT_FLUSHED svrTrapCacheNotFlushed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Data in cache not flushed during power up." --#TYPE "Data in cache not flushed during power up" --#SUMMARY "Adapter %s: Data in cache not flushed during power up (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "If the problem occurs repeatedly call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10508 -- EVT_REBUILD_RESUMED svrTrapRebuildResumed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild resumed on disk." --#TYPE "Rebuild resumed on disk" --#SUMMARY "Adapter %s: Rebuild resumed on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10509 -- EVT_AUTO_REBUILD_STARTED svrTrapAutoRebuildStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic rebuild started on logical drive." --#TYPE "Automatic rebuild started on logical drive" --#SUMMARY "Adapter %s: Automatic rebuild started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10510 -- EVT_BGI_RESTARTED svrTrapBGIRestarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI restarted on logical drive." --#TYPE "BGI restarted on logical drive" --#SUMMARY "Adapter %s: BGI restarted on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10511 -- EVT_LOGICALDRIVE_DISK_MEDIA_ERROR svrTrapLDPDMediaError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive error on disk media." --#TYPE "Logical drive error on disk media" --#SUMMARY "Adapter %s: Logical drive %s: Error on disk %s %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10512 -- EVT_LD_REBUILD_RESUMED svrTrapLDRebuildResumed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild on logical drive resumed." --#TYPE "Rebuild on logical drive resumed" --#SUMMARY "Adapter %s: Rebuild on logical drive %s resumed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10513 -- EVT_CHECK_ERROR_LBA svrTrapLDConCheckFinishedWithLBAErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check finished with errors on logical drive." --#TYPE "Consistency check finished with errors on logical drive" --#SUMMARY "Adapter %s: Consistency check finished with errors on logical drive %s: %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Manually initiate second consistency check (MDC). 2) If problem persists backup data from affected logical drive. 3) Delete and recreate affected logical drive. 4) Restore data." --#STATE OPERATIONAL ::= 10514 -- EVT_CHECK_ERROR_LOG svrTrapLDConCheckErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Error on logical drive detected." --#TYPE "Error on logical drive detected" --#SUMMARY "Adapter %s: Error on logical drive %s detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check/replace cable between controller and affected disk. 2) If problem persists replace disk." --#STATE OPERATIONAL ::= 10515 -- EVT_DISK_TEMPORARY_OFFLINE svrTrapPDForcedFromFailedToOnline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk forced from failed to online." --#TYPE "Disk forced from failed to online" --#SUMMARY "Adapter %s: Disk (%s) forced from failed to online (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10516 -- EVT_TRANSFER_SPEED_CHANGED svrTrapPDTransferSpeedValueChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Transfer speed of disk changed." --#TYPE "Transfer speed of disk changed" --#SUMMARY "Adapter %s: Transfer speed of disk (%s) changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Check/replace cable between controller and affected disk. 2) If problem persists replace disk." --#STATE OPERATIONAL ::= 10517 -- EVT_SAS_PORT_LINK_LOST svrTrapSASPortLinkLost TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS port lost link." --#TYPE "SAS port lost link" --#SUMMARY "Adapter %s: SAS port %s lost link (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Unplug affected disk, wait 30 seconds, reinsert it. 2) Check/replace cable between controller and affected disk. 3) Check version of RAID controller/iRMC firmware, and BIOS. 4) Replace affected disk." --#STATE OPERATIONAL ::= 10518 -- EVT_SAS_PORT_LINK_RESTORED svrTrapSASPortLinkRestored TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS port restored link." --#TYPE "SAS port restored link" --#SUMMARY "Adapter %s: SAS port %s restored link (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10519 -- EVT_CTRL_CACHE_MODE_BACK svrTrapCacheModeChangedToWriteBack TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache mode changed to Write-back." --#TYPE "Cache mode changed to Write-back" --#SUMMARY "Adapter %s: Cache mode changed to Write-back (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10520 -- EVT_CTRL_CACHE_MODE_WRITETHROUGH svrTrapCacheModeChangedToWriteThrough TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache mode changed to Write-through." --#TYPE "Cache mode changed to Write-through" --#SUMMARY "Adapter %s: Cache mode changed to Write-through (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10521 -- EVT_PD_SPARE_AFFINITY_IGNORED svrTrapPDSpareAffinityIgnored TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Global affinity hot spare commissioned in a different enclosure." --#TYPE "Global affinity hot spare commissioned in a different enclosure" --#SUMMARY "Adapter %s: Global affinity hot spare (%s) commissioned in a different enclosure (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your RAID configuration." --#STATE OPERATIONAL ::= 10522 -- EVT_FOREIGN_CFG_TABLE_OVERFLOW svrTrapForeignConfigTableOverflow TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Foreign configuration table overflow." --#TYPE "Foreign configuration table overflow" --#SUMMARY "Adapter %s: Foreign configuration table overflow (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10523 -- EVT_FOREIGN_CFG_PARTIAL_IMPORT svrTrapForeignConfigPartialImport TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Partial foreign configuration imported." --#TYPE "Partial foreign configuration imported" --#SUMMARY "Adapter %s: Partial foreign configuration imported, disks not imported (device numbers): %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Only parts of your config were imported. 1) Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10524 -- EVT_SAS_MUX_ACTIVATED_CONNECTOR svrTrapSASMuxActivatedConnector TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Connector is active." --#TYPE "Connector is active" --#SUMMARY "Adapter %s: Connector %s is active (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10525 -- EVT_CTRL_MISSING_AFTER_REBOOT svrTrapctrlmissingafterreboot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter missing after reboot." --#TYPE "Adapter missing after reboot" --#SUMMARY "Adapter %s: Adapter missing after reboot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Note: Only informational if controller was removed by user otherwise: 1) Unplug affected controller, wait 30 seconds, reinsert it. 2) If problem persists replace affected controller. 3) If problem persists replace mainboard." --#STATE OPERATIONAL ::= 10526 -- EVT_CTRL_APPEARED_AFTER_REBOOT svrTrapctrlappearedafterreboot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter appeared new after reboot." --#TYPE "Adapter appeared new after reboot" --#SUMMARY "Adapter %s: Adapter appeared new after reboot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10527 -- EVT_DISK_REBUILD_CANCELED svrTrapPDRebuildAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild aborted on disk." --#TYPE "Rebuild aborted on disk" --#SUMMARY "Adapter %s: Rebuild aborted on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Only informational if rebuild was aborted by user otherwise: 1) Initiate a rebuild again (e.g. via ServerView RAID Manager)." --#STATE DEGRADED ::= 10528 -- EVT_CHECK_ERROR_CORRECTABLE svrTrapCheckErrorCorrectable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check finished with correctable errors on logical drive." --#TYPE "Consistency check finished with correctable errors on logical drive" --#SUMMARY "Adapter %s: Consistency check finished with %s correctable errors on logical drive %s (Server %s)" --#ARGUMENTS { 2, 4, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Manually initiate second consistency check (MDC). 2) If problem persists backup data from affected logical drive. 3) Delete and recreate affected logical drive. 4) Restore data." --#STATE OPERATIONAL ::= 10529 -- EVT_CHECK_ERROR_UNCORRECTABLE svrTrapCheckErrorUnCorrectable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check finished with uncorrectable errors on logical drive." --#TYPE "Consistency check finished with uncorrectable errors on logical drive" --#SUMMARY "Adapter %s: Consistency check finished with %s uncorrectable errors on logical drive %s (Server %s)" --#ARGUMENTS { 2, 4, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Backup data from affected logical drive. 2) Delete and recreate affected logical drive. 3) Restore data." --#STATE OPERATIONAL ::= 10530 -- EVT_MDC_ERROR_CORRECTABLE svrTrapMDCErrorCorrectable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC finished with correctable errors on logical drive." --#TYPE "MDC finished with correctable errors on logical drive" --#SUMMARY "Adapter %s: MDC finished with %s correctable errors on logical drive %s (Server %s)" --#ARGUMENTS { 2, 4, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10531 -- EVT_MDC_ERROR_UNCORRECTABLE svrTrapMDCErrorUnCorrectable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC finished with uncorrectable errors on logical drive." --#TYPE "MDC finished with uncorrectable errors on logical drive" --#SUMMARY "Adapter %s: MDC finished with %s uncorrectable errors on logical drive %s (Server %s)" --#ARGUMENTS { 2, 4, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Backup data from affected logical drive. 2) Delete and recreate affected logical drive. 3) Restore data." --#STATE OPERATIONAL ::= 10532 -- EVT_RESET_ERROR_COUNTERS svrTrapResetErrorCounters TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Error counters reset on disk." --#TYPE "Error counters reset on disk" --#SUMMARY "Adapter %s: Error counters reset on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10533 -- EVT_ADAPTER_PROPERTY_CHANGED svrTrapAdapterPropertyChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Changed adapter property detected after reboot." --#TYPE "Changed adapter property detected after reboot" --#SUMMARY "Adapter %s: Changed adapter property detected after reboot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check your adapter properties (e.g. via ServerView RAID Manager)." --#STATE OPERATIONAL ::= 10534 -- EVT_CTRL_FRU svrTrapAdapterFRU TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Board revision." --#TYPE "Board revision" --#SUMMARY "Adapter %s: Board revision %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10535 -- EVT_PD_COMMAND_TIMEOUT svrTrapPDCommandTimeout TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Command timeout on disk." --#TYPE "Command timeout on disk" --#SUMMARY "Adapter %s: Command timeout on disk (%s), CDB:%s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Only if problem occurs repeatedly: 1) Check/replace cable between controller and affected disk. 2) If problem persists replace affected disk and/or backplane." --#STATE OPERATIONAL ::= 10536 -- EVT_PD_RESET svrTrapPDReset TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk reset." --#TYPE "Disk reset" --#SUMMARY "Adapter %s: Disk (%s) reset (type %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Only if problem occurs repeatedly: 1) Check/replace cable between controller and affected disk. 2) If problem persists replace affected disk." --#STATE OPERATIONAL ::= 10537 -- EVT_LD_BBM_LOG_80_PERCENT_FULL svrTrapLDLog80Full TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table on logical drive is 80 percent full." --#TYPE "Bad block table on logical drive is 80 percent full" --#SUMMARY "Adapter %s: Bad block table on logical drive %s is 80 percent full (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check for additional error messages for affected disk." --#STATE OPERATIONAL ::= 10538 -- EVT_LD_BBM_LOG_FULL svrTrapLDLogFull TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table on logical drive is full." --#TYPE "Bad block table on logical drive is full" --#SUMMARY "Adapter %s: Bad block table on logical drive %s is full; unable to log LBA %s (on disk (%s) at LBA %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check for additional error messages for affected disk." --#STATE OPERATIONAL ::= 10539 -- EVT_LD_LOG_MEDIUM_ERROR svrTrapLDLogUncorrMediumError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Uncorrectable medium error logged for logical drive." --#TYPE "Uncorrectable medium error logged for logical drive" --#SUMMARY "Adapter %s: Uncorrectable medium error logged for logical drive %s at LBA %s (on disk (%s) at LBA %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check for additional error messages for affected disk." --#STATE OPERATIONAL ::= 10540 -- EVT_LD_CORRECTED_MEDIUM_ERROR svrTrapLDMediumErrorCorr TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Medium error corrected on logical drive." --#TYPE "Medium error corrected on logical drive" --#SUMMARY "Adapter %s: Medium error corrected on logical drive %s at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "Check for additional error messages for affected disk." --#STATE OPERATIONAL ::= 10541 -- EVT_PD_BBM_LOG_100_PERCENT_FULL svrTrapPDBadBlockLog100Full TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table on disk is 100 percent full." --#TYPE "Bad block table on disk is 100 percent full" --#SUMMARY "Adapter %s: Bad block table on disk (%s) is 100 percent full (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10542 -- EVT_LD_BBM_LOG_100_PERCENT_FULL svrTrapLDBadBlockLog100Full TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table on logical drive is 100 percent full." --#TYPE "Bad block table on logical drive is 100 percent full" --#SUMMARY "Adapter %s: Bad block table on logical drive %s is 100 percent full (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check for additional error messages for affected disk." --#STATE OPERATIONAL ::= 10543 -- EVT_DIAG_FAULTY_IOP_DETECTED svrTrapDiagFaultyIOPDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter needs replacement, faulty IOP detected." --#TYPE "Adapter needs replacement, faulty IOP detected" --#SUMMARY "Adapter %s: Adapter needs replacement, faulty IOP detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Replace affected RAID controller." --#STATE NONOPERATIONAL ::= 10544 -- EVT_PD_COPYBACK_START svrTrapPDCopyBackStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback started on disk from disk." --#TYPE "Copyback started on disk from disk" --#SUMMARY "Adapter %s: Copyback started on disk (%s) from disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10545 -- EVT_PD_COPYBACK_ABORT svrTrapPDCopyBackAbort TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback aborted on disk from disk." --#TYPE "Copyback aborted on disk from disk" --#SUMMARY "Adapter %s: Copyback aborted on disk (%s) from disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10546 -- EVT_PD_COPYBACK_DONE svrTrapPDCopyBackDone TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback complete on disk from disk." --#TYPE "Copyback complete on disk from disk" --#SUMMARY "Adapter %s: Copyback complete on disk (%s) from disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10547 -- EVT_PD_COPYBACK_PROGRESS svrTrapPDCopyBackProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback progress." --#TYPE "Copyback progress" --#SUMMARY "Adapter %s: Copyback progress on disk (%s) is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10548 -- EVT_PD_COPYBACK_RESUME svrTrapPDCopyBackResume TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback resumed on disk." --#TYPE "Copyback resumed on disk" --#SUMMARY "Adapter %s: Copyback resumed on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10549 -- EVT_PD_COPYBACK_AUTO svrTrapPDCopyBackAuto TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback automatically started on disk." --#TYPE "Copyback automatically started on disk" --#SUMMARY "Adapter %s: Copyback automatically started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10550 -- EVT_PD_COPYBACK_FAILED svrTrapPDCopyBackFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback failed on disk." --#TYPE "Copyback failed on disk" --#SUMMARY "Adapter %s: Copyback failed on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check for additional error messages for affected disk." --#STATE OPERATIONAL ::= 10551 -- EVT_CTRL_EPOW_UNSUCCESSFUL svrTrapCtrlEpowUnsuccessful TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Early power off warning was unsuccessful." --#TYPE "Early power off warning was unsuccessful" --#SUMMARY "Adapter %s: Early power off warning was unsuccessful (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10552 -- EVT_BBU_FRU svrTrapBBUFRU TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU FRU." --#TYPE "BBU FRU" --#SUMMARY "Adapter %s: BBU FRU is %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10553 -- EVT_PD_FRU svrTrapPDFRU TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk FRU." --#TYPE "Disk FRU" --#SUMMARY "Adapter %s: Disk (%s) FRU is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10554 -- EVT_CTRL_HW_REVISION svrTrapCtrlHWRevision TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter hardware revision ID." --#TYPE "Adapter hardware revision ID" --#SUMMARY "Adapter %s: Adapter hardware revision ID %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10555 -- EVT_FOREIGN_CFG_UPGRADE_REQUIRED svrTrapForeignCfgUpgradeRequired TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Foreign configuration metadata needs to be upgraded." --#TYPE "Foreign configuration metadata needs to be upgraded" --#SUMMARY "Adapter %s: Foreign configuration metadata needs to be upgraded, may become incompatible (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10556 -- EVT_CONT_ON_ERROR_ENABLED svrTrapAdapterContOnErrorEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BIOS continue on error enabled." --#TYPE "BIOS continue on error enabled" --#SUMMARY "Adapter %s: BIOS continue on error enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10557 -- EVT_CONT_ON_ERROR_DISABLED svrTrapAdapterContOnErrorDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BIOS continue on error disabled." --#TYPE "BIOS continue on error disabled" --#SUMMARY "Adapter %s: BIOS continue on error disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10558 -- EVT_PD_FAIL_EX svrTrapPDFailEx TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Additional information for failed disk." --#TYPE "Additional information for failed disk" --#SUMMARY "Adapter %s: Additional information for failed disk (%s) - firmware version: %s, serial number %s, first use: %s, total running time: %s days (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 7, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE NONOPERATIONAL ::= 10559 -- EVT_MIGRATION_FINISHED_EX svrTrapMigrationFinishedEx TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reread disk information." --#TYPE "Reread disk information" --#SUMMARY "Adapter %s: If the logical size of logical drive %s has changed use appropriate operating system tool to reread disk information (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10560 -- EVT_ENCL_DEVICES_EXPOSURE_CHANGED svrTrapEnclDevicesExposureChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure device exposure changed." --#TYPE "Enclosure device exposure changed" --#SUMMARY "Adapter %s: Enclosure device exposure changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10561 -- EVT_CC_ABORT_ON_ERROR_CHANGED svrTrapCCAbortOnErrorChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Abort consistency check on error changed." --#TYPE "Abort consistency check on error changed" --#SUMMARY "Adapter %s: Abort consistency check on error changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10562 -- EVT_MDC_ABORT_ON_ERROR_CHANGED svrTrapMDCAbortOnErrorChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Abort MDC on error changed." --#TYPE "Abort MDC on error changed" --#SUMMARY "Adapter %s: Abort MDC on error changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10563 -- EVT_PD_SAS_REDUNDANT_PATH_RESTORED svrTrapPDSASRedundantPathRestored TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundant path restored." --#TYPE "Redundant path restored" --#SUMMARY "Adapter %s: Redundant path restored for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10564 -- EVT_PD_SAS_REDUNDANT_PATH_BROKEN svrTrapPDSASRedundantPathBroken TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundant path broken." --#TYPE "Redundant path broken" --#SUMMARY "Adapter %s: Redundant path broken for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10565 -- EVT_ENCL_REDUNDANT_ENCL_MODULE_INSERTED svrTrapEnclRedundantEnclModuleInserted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundant enclosure inserted." --#TYPE "Redundant enclosure inserted" --#SUMMARY "Adapter %s: Redundant enclosure I/O module %s inserted for I/O module %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10566 -- EVT_ENCL_REDUNDANT_ENCL_MODULE_REMOVED svrTrapEnclRedundantEnclModuleRemoved TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundant enclosure removed." --#TYPE "Redundant enclosure removed" --#SUMMARY "Adapter %s: Redundant enclosure I/O module %s removed for I/O module %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10567 -- EVT_CTRL_PR_CANT_START svrTrapCtrlPRCantStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read can't be started." --#TYPE "Patrol Read can't be started" --#SUMMARY "Adapter %s: Patrol Read can't be started, all disks are either not online, or are in a logical drive with an active process, or are in an excluded logical drive (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10568 -- EVT_PD_COPYBACK_ABORT_BY_USER svrTrapPDCopyBackAbortByUser TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback aborted by user." --#TYPE "Copyback aborted by user" --#SUMMARY "Adapter %s: Copyback aborted by user on disk (%s) from disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10569 -- EVT_PD_COPYBACK_ABORT_FOR_SPARE svrTrapPDCopyBackAbortForSpare TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback aborted on hot spare." --#TYPE "Copyback aborted on hot spare" --#SUMMARY "Adapter %s: Copyback aborted on hot spare (%s) from disk (%s) as hot spare needed for rebuild (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10570 -- EVT_PD_COPYBACK_ABORT_FOR_REBUILD svrTrapPDCopyBackAbortForRebuild TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback aborted for rebuild." --#TYPE "Copyback aborted for rebuild" --#SUMMARY "Adapter %s: Copyback aborted on disk (%s) from disk (%s) as rebuild required in the array (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10571 -- EVT_LD_CACHE_DISCARDED svrTrapCDCacheDiscarded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache discarded for logical drive (missing or offline)." --#TYPE "Cache discarded for logical drive (missing or offline)" --#SUMMARY "Adapter %s: Cache discarded for logical drive (missing or offline) %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10572 -- EVT_REDUNDANT_COPY_STARTED svrTrapRedundantCopyStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundancy building started on disk." --#TYPE "Redundancy building started on disk" --#SUMMARY "Adapter %s: Redundancy building started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10573 -- EVT_REDUNDANT_COPY_FINISHED svrTrapRedundantCopyFinished TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundancy building finished on disk." --#TYPE "Redundancy building finished on disk" --#SUMMARY "Adapter %s: Redundancy building finished on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10574 -- EVT_REDUNDANT_COPY_FAILED svrTrapRedundantCopyFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundancy building failed on disk." --#TYPE "Redundancy building failed on disk" --#SUMMARY "Adapter %s: Redundancy building failed on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10575 -- EVT_REDUNDANT_COPY_CANCELED svrTrapRedundantCopyAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundancy building aborted on disk." --#TYPE "Redundancy building aborted on disk" --#SUMMARY "Adapter %s: Redundancy building aborted on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10576 -- EVT_REDUNDANT_COPY_PAUSED svrTrapRedundantCopyPaused TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundancy building suspended on disk." --#TYPE "Redundancy building suspended on disk" --#SUMMARY "Adapter %s: Redundancy building suspended on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10577 -- EVT_IDLE_MODE_ENABLED svrTrapIdleModeEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk power management idle mode enabled." --#TYPE "Disk power management idle mode enabled" --#SUMMARY "Adapter %s: Disk (%s) power management idle mode enabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10578 -- EVT_IDLE_MODE_DISABLED svrTrapIdleModeDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk power management idle mode disabled." --#TYPE "Disk power management idle mode disabled" --#SUMMARY "Adapter %s: Disk (%s) power management idle mode disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10579 -- EVT_IDLE_TIMER_CHANGED svrTrapIdleConditionTimerChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk power management idle condition timer changed." --#TYPE "Disk power management idle condition timer changed" --#SUMMARY "Adapter %s: Disk (%s) power management idle condition timer changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10580 -- EVT_STANDBY_MODE_ENABLED svrTrapStandbyModeEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk power management standby mode enabled." --#TYPE "Disk power management standby mode enabled" --#SUMMARY "Adapter %s: Disk (%s) power management standby mode enabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10581 -- EVT_STANDBY_MODE_DISABLED svrTrapStandbyModeDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk power management standby mode disabled." --#TYPE "Disk power management standby mode disabled" --#SUMMARY "Adapter %s: Disk (%s) power management standby mode disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10582 -- EVT_STANDBY_TIMER_CHANGED svrTrapStandbyTimerChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk power management standby condition timer changed." --#TYPE "Disk power management standby condition timer changed" --#SUMMARY "Adapter %s: Disk (%s) power management standby condition timer changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10583 -- EVT_PD_TOO_SMALL_FOR_COPYBACK svrTrapPDTooSmallForCopyBack TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback cannot be started as disk is too small for disk." --#TYPE "Copyback cannot be started as disk is too small for disk" --#SUMMARY "Adapter %s: Copyback cannot be started as disk (%s) is too small for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10584 -- EVT_PD_NO_COPYBACK_SAS_SATA_MIX_NOT_ALLOWED_IN_LD svrTrapPDNoCopyBackSASSATAMixNotAllowedInLD TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback cannot be started on disk from disk as SAS/SATA mixing is not supported in an array." --#TYPE "Copyback cannot be started on disk from disk as SAS/SATA mixing is not supported in an array" --#SUMMARY "Adapter %s: Copyback cannot be started on disk (%s) from disk (%s) as SAS/SATA mixing is not supported in an array (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10585 -- EVT_PD_FW_DOWNLOAD_START svrTrapPDFWDownloadStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware update started on disk." --#TYPE "Firmware update started on disk" --#SUMMARY "Adapter %s: Firmware update started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10586 -- EVT_PD_FW_DOWNLOAD_COMPLETE svrTrapPDFWDownloadComplete TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware update completed on disk." --#TYPE "Firmware update completed on disk" --#SUMMARY "Adapter %s: Firmware update completed on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10587 -- EVT_PD_FW_DOWNLOAD_TIMEOUT svrTrapPDFWDownloadTimeout TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware update timeout on disk." --#TYPE "Firmware update timeout on disk" --#SUMMARY "Adapter %s: Firmware update timeout on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10588 -- EVT_PD_FW_DOWNLOAD_FAILED svrTrapPDFWDownloadFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware update failed on disk." --#TYPE "Firmware update failed on disk" --#SUMMARY "Adapter %s: Firmware update failed on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10589 -- EVT_CTRL_PROP_CHANGED svrTrapCtrlPropChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter properties changed." --#TYPE "Adapter properties changed" --#SUMMARY "Adapter %s: Adapter properties changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10590 -- EVT_CTRL_PR_PROP_CHANGED svrTrapCtrlPRPropChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read properties changed." --#TYPE "Patrol Read properties changed" --#SUMMARY "Adapter %s: Patrol Read properties changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10591 -- EVT_CTRL_CC_SCHEDULE_PROP_CHANGED svrTrapCtrlCCSchedulePropChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC schedule properties changed." --#TYPE "MDC schedule properties changed" --#SUMMARY "Adapter %s: MDC schedule properties changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10592 -- EVT_BBU_PROP_CHANGED svrTrapCtrlBBUPropChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU properties changed." --#TYPE "BBU properties changed" --#SUMMARY "Adapter %s: BBU properties changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10593 -- EVT_MDC_RESUMED svrTrapMDCContinuedOnLogicalDrive TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC resumed on logical drive." --#TYPE "MDC resumed on logical drive" --#SUMMARY "Adapter %s: MDC resumed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10594 -- EVT_CTRL_SPINDOWN_MODE_ENABLED svrTrapCtrlSpindownModeEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Spindown mode enabled." --#TYPE "Spindown mode enabled" --#SUMMARY "Adapter %s: Spindown mode enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10595 -- EVT_CTRL_SPINDOWN_MODE_DISABLED svrTrapCtrlSpindownModeDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Spindown mode disabled." --#TYPE "Spindown mode disabled" --#SUMMARY "Adapter %s: Spindown mode disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10596 -- EVT_CTRL_SPINDOWN_DELAY_CHANGED svrTrapCtrlSpindownDelayChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Spindown delay changed." --#TYPE "Spindown delay changed" --#SUMMARY "Adapter %s: Spindown delay changed to %s seconds (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10597 -- EVT_CTRL_SPINUP_DELAY_CHANGED svrTrapCtrlSpinupDelayChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Spinup delay changed." --#TYPE "Spinup delay changed" --#SUMMARY "Adapter %s: Spinup delay changed to %s seconds (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10598 -- EVT_REDUNDANT_COPY_RATE_CHANGED_EX svrTrapAdapterRedundantCopyRateChangedEx TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundancy build rate changed." --#TYPE "Redundancy build rate changed" --#SUMMARY "Adapter %s: Redundancy build rate changed to %s percent (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10599 -- EVT_COPY_BACK_RATE_CHANGED_EX svrTrapAdapterCopybackRateChangedEx TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback rate changed." --#TYPE "Copyback rate changed" --#SUMMARY "Adapter %s: Copyback rate changed to %s percent (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10600 -- EVT_BBU_PERIODIC_RELEARN_PENDING svrTrapBBUPeriodicRelearnPending TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Periodic BBU relearn is pending." --#TYPE "Periodic BBU relearn is pending" --#SUMMARY "Adapter %s: Periodic BBU relearn is pending. Please initiate manual learn cycle as automatic learn is not enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Initiate manual learn cycle as automatic learn is not enabled." --#STATE OPERATIONAL ::= 10601 -- EVT_CTRL_LOCK_KEY_CREATED svrTrapCtrlLockKeyCreated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key created." --#TYPE "Disk security key created" --#SUMMARY "Adapter %s: Disk security key created (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10602 -- EVT_CTRL_LOCK_KEY_BACKEDUP svrTrapCtrlLockKeyBackedup TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key backed up." --#TYPE "Disk security key backed up" --#SUMMARY "Adapter %s: Disk security key backed up (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10603 -- EVT_CTRL_LOCK_KEY_VERIFIED_ESCROW svrTrapCtrlLockKeyVerifiedEscrow TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key from escrow, verified." --#TYPE "Disk security key from escrow, verified" --#SUMMARY "Adapter %s: Disk security key from escrow, verified (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10604 -- EVT_CTRL_LOCK_KEY_REKEYED svrTrapCtrlLockKeyRekeyed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key changed." --#TYPE "Disk security key changed" --#SUMMARY "Adapter %s: Disk security key changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10605 -- EVT_CTRL_LOCK_KEY_REKEY_FAILED svrTrapCtrlLockKeyRekeyFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key, re-key operation failed." --#TYPE "Disk security key, re-key operation failed" --#SUMMARY "Adapter %s: Disk security key, re-key operation failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10606 -- EVT_CTRL_LOCK_KEY_INVALID svrTrapCtrlLockKeyInvalid TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key is invalid." --#TYPE "Disk security key is invalid" --#SUMMARY "Adapter %s: Disk security key is invalid (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10607 -- EVT_CTRL_LOCK_KEY_DESTROYED svrTrapCtrlLockKeyDestroyed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key destroyed." --#TYPE "Disk security key destroyed" --#SUMMARY "Adapter %s: Disk security key destroyed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10608 -- EVT_CTRL_ESCROW_KEY_INVALID svrTrapCtrlEscrowKeyInvalid TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key from escrow is invalid." --#TYPE "Disk security key from escrow is invalid" --#SUMMARY "Adapter %s: Disk security key from escrow is invalid (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10609 -- EVT_LD_SECURED svrTrapLDSecured TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is now secured." --#TYPE "Logical drive is now secured" --#SUMMARY "Adapter %s: Logical drive %s is now secured (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10610 -- EVT_LD_PARTIALLY_SECURED svrTrapLDPartiallySecured TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is partially secured." --#TYPE "Logical drive is partially secured" --#SUMMARY "Adapter %s: Logical drive %s is partially secured (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10611 -- EVT_PD_SECURED svrTrapPDSecured TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security activated." --#TYPE "Disk security activated" --#SUMMARY "Adapter %s: Disk (%s) security activated (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10612 -- EVT_PD_UNSECURED svrTrapPDUnsecured TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security disabled." --#TYPE "Disk security disabled" --#SUMMARY "Adapter %s: Disk (%s) security disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10613 -- EVT_PD_REPROVISIONED svrTrapPDReprovisioned TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk is reprovisioned." --#TYPE "Disk is reprovisioned" --#SUMMARY "Adapter %s: Disk (%s) is reprovisioned (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10614 -- EVT_PD_LOCK_KEY_REKEYED svrTrapPDLockKeyRekeyed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key changed." --#TYPE "Disk security key changed" --#SUMMARY "Adapter %s: Disk (%s) security key changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10615 -- EVT_PD_SECURITY_FAILURE svrTrapPDSecurityFailure TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Security subsystem problems detected for disk." --#TYPE "Security subsystem problems detected for disk" --#SUMMARY "Adapter %s: Security subsystem problems detected for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10616 -- EVT_LD_CACHE_PINNED svrTrapLDCachePinned TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter cache preserved for missing or offline logical drive." --#TYPE "Adapter cache preserved for missing or offline logical drive" --#SUMMARY "Adapter %s: Adapter cache preserved for missing or offline logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check error messages for related logical drive and resolve problems." --#STATE OPERATIONAL ::= 10617 -- EVT_CTRL_BOOT_LDS_CACHE_PINNED svrTrapBootLDsCachePinned TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter cache preserved for missing or offline logical drives." --#TYPE "Adapter cache preserved for missing or offline logical drives" --#SUMMARY "Adapter %s: Adapter cache preserved for missing or offline logical drives (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check the reason why the logical drives are missing. 2) If the deletion of logical drives was intended, confirm the deletion of pinned cache data at next boot. 3) If not intended, check for defect disks and bring the logical drives at least to the status 'degraded'. Afterwards the adapter will write the pinned cache to the logical drives." --#STATE OPERATIONAL ::= 10618 -- EVT_CTRL_LDS_CACHE_DISCARDED_BY_USER svrTrapLDsCacheDiscardedByUser TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter cache discarded by user for logical drives." --#TYPE "Adapter cache discarded by user for logical drives" --#SUMMARY "Adapter %s: Adapter cache discarded by user for logical drives (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10619 -- EVT_LD_CACHE_DESTAGED svrTrapLDCacheDestaged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter cache destaged for logical drive." --#TYPE "Adapter cache destaged for logical drive" --#SUMMARY "Adapter %s: Adapter cache destaged for logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10620 -- EVT_LD_CC_STARTED_ON_INCONSISTENT_LD svrTrapLDCCStartedOnInconsistentLD TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC started on an inconsistent logical drive." --#TYPE "MDC started on an inconsistent logical drive" --#SUMMARY "Adapter %s: MDC started on an inconsistent logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10621 -- EVT_CTRL_LOCK_KEY_FAILED svrTrapCtrlLockKeyFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key failure, cannot access secured configuration." --#TYPE "Disk security key failure, cannot access secured configuration" --#SUMMARY "Adapter %s: Disk security key failure, cannot access secured configuration (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10622 -- EVT_CTRL_SECRET_KEY_INVALID svrTrapCtrlSecretKeyInvalid TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security pass phrase from user is invalid." --#TYPE "Disk security pass phrase from user is invalid" --#SUMMARY "Adapter %s: Disk security pass phrase from user is invalid (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10623 -- EVT_CONFIGURATION_WRITTEN_TO_FILE svrTrapConfigurationWrittenToFile TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Complete RAID configuration written to file on the server." --#TYPE "Complete RAID configuration written to file on the server" --#SUMMARY "Complete RAID configuration written to file '%s' on the server (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10624 -- EVT_ABNORMAL_SHUTDOWN svrTrapAbnormalShutdown TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Abnormal shutdown sequence detected." --#TYPE "Abnormal shutdown sequence detected" --#SUMMARY "Adapter %s: Abnormal shutdown sequence detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10625 -- EVT_CTLR_INTERNAL_HARD_ERROR svrTrapCtlrInternalHardError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal hardware error." --#TYPE "Internal hardware error" --#SUMMARY "Adapter %s: Internal hardware error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10626 -- EVT_CTLR_INTERNAL_HARD_ERROR_POST svrTrapCtlrInternalHardErrorPOST TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal hardware error during POST." --#TYPE "Internal hardware error during POST" --#SUMMARY "Adapter %s: Internal hardware error during POST (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10627 -- EVT_PD_BBT_THRESHOLD_EXCEEDED svrTrapPDBBTThresholdExceeded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table threshold exceeded." --#TYPE "Bad block table threshold exceeded" --#SUMMARY "Adapter %s: Bad block table of disk (%s) threshold exceeded; table is about to overflow (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10628 -- EVT_PD_BBT_CLEARED svrTrapPDBBTCleared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table cleared." --#TYPE "Bad block table cleared" --#SUMMARY "Adapter %s: Bad block table of disk (%s) cleared (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10629 -- EVT_PD_FAIL_BBT svrTrapPDFailBBT TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failed due to bad block table overflow." --#TYPE "Disk failed due to bad block table overflow" --#SUMMARY "Adapter %s: Disk (%s) failed due to bad block table overflow (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10630 -- EVT_PD_FAIL_BOOT svrTrapPDFailBoot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failure detected during POST." --#TYPE "Disk failure detected during POST" --#SUMMARY "Adapter %s: Disk (%s) failure detected during POST (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10631 -- EVT_CTLR_FAIL_BOOT svrTrapCtlrFailBoot TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Failure detected during POST." --#TYPE "Failure detected during POST" --#SUMMARY "Adapter %s: Failure detected during POST (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 10632 -- EVT_PD_MULTI_FAIL svrTrapPDMultiFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Multiple failure on disk detected." --#TYPE "Multiple failure on disk detected" --#SUMMARY "Adapter %s: Multiple failure on disk (%s) detected, internal info %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10633 -- EVT_BGI_STARTED_CTLR_CHANGE svrTrapBGIStartedCtlrChange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI started due to adapter exchange." --#TYPE "BGI started due to adapter exchange" --#SUMMARY "Adapter %s: BGI started due to adapter exchange (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10634 -- EVT_PD_FAIL_PR svrTrapPDFailPR TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failure detected by Patrol Read." --#TYPE "Disk failure detected by Patrol Read" --#SUMMARY "Adapter %s: Disk (%s) failure detected by Patrol Read (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10635 -- EVT_PD_FAIL_REDUNDANT_COPY_NO_ERROR svrTrapPDFailRedundantCopyNoError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failure detected after successfully building redundancy." --#TYPE "Disk failure detected after successfully building redundancy" --#SUMMARY "Adapter %s: Disk (%s) failure detected after successfully building redundancy (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10636 -- EVT_PD_FAIL_REDUNDANT_COPY_ERROR svrTrapPDFailRedundantCopyError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failure detected after aborting building redundancy." --#TYPE "Disk failure detected after aborting building redundancy" --#SUMMARY "Adapter %s: Disk (%s) failure detected after aborting building redundancy (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10637 -- EVT_PD_FAIL svrTrapPDFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failed." --#TYPE "Disk failed" --#SUMMARY "Adapter %s: Disk (%s) failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10638 -- EVT_PD_FAIL_EX2 svrTrapPDFailEx2 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failed." --#TYPE "Disk failed" --#SUMMARY "Adapter %s: Disk (%s) failed, internal info %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10639 -- EVT_CTLR_CHANGED svrTrapCtlrChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter was exchanged." --#TYPE "Adapter was exchanged" --#SUMMARY "Adapter %s was exchanged (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10640 -- EVT_CTLR_FLASH_UPLOAD_STARTED svrTrapCtlrFlashUploadStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware upload started." --#TYPE "Firmware upload started" --#SUMMARY "Adapter %s: Firmware upload started (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10641 -- EVT_CTLR_FLASH_UPLOAD_RUNNING svrTrapCtlrFlashUploadDone TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware upload is executing." --#TYPE "Firmware upload is executing" --#SUMMARY "Adapter %s: Firmware upload is executing (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10642 -- EVT_CTLR_WRITE_CONFIG_DONE svrTrapCtlrWriteConfigDone TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Save configuration." --#TYPE "Save configuration" --#SUMMARY "Adapter %s: Save configuration (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10643 -- EVT_ARRAYS_CREATED svrTrapArraysCreated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Arrays created." --#TYPE "Arrays created" --#SUMMARY "Adapter %s: Arrays %s created (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10644 -- EVT_ARRAYS_DELETED svrTrapArraysDeleted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Arrays deleted." --#TYPE "Arrays deleted" --#SUMMARY "Adapter %s: Arrays %s deleted (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10645 -- EVT_CTLR_SET_TRACE_MODE svrTrapCtlrSetTraceMode TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Trace mode changed." --#TYPE "Trace mode changed" --#SUMMARY "Adapter %s: Trace mode changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10646 -- EVT_CTLR_CLEAR_PANIC_DUMP_DATA svrTrapCtlrClearPanicDumpData TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Panic dump data deleted." --#TYPE "Panic dump data deleted" --#SUMMARY "Adapter %s: Panic dump data deleted (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10647 -- EVT_CTLR_FORCE_PANIC svrTrapCtlrForcePanic TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Panic forced." --#TYPE "Panic forced" --#SUMMARY "Adapter %s: Panic forced (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10648 -- EVT_CTLR_SET_SCRIPT svrTrapCtlrSetScript TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Startup script set." --#TYPE "Startup script set" --#SUMMARY "Adapter %s: Startup script set (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10649 -- EVT_CTLR_EXBIOS_PARAM_CHANGED svrTrapCtlrEXBIOSParamChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "EXBIOS parameter changed." --#TYPE "EXBIOS parameter changed" --#SUMMARY "Adapter %s: EXBIOS parameter changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10650 -- EVT_CTLR_SET_AUTO_OFFLINE svrTrapCtlrSetAutoOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Auto offline recovery mode changed." --#TYPE "Auto offline recovery mode changed" --#SUMMARY "Adapter %s: Auto offline recovery mode changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10651 -- EVT_CTLR_SET_CLOCK svrTrapCtlrSetClock TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Clock time changed." --#TYPE "Clock time changed" --#SUMMARY "Adapter %s: Clock time changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10652 -- EVT_CTLR_SET_FACTORY_SETTINGS svrTrapCtlrSetFactorySettings TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Factory shipment settings restored." --#TYPE "Factory shipment settings restored" --#SUMMARY "Adapter %s: Factory shipment settings restored (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10653 -- EVT_CTLR_DISK_LOG_CLEARED svrTrapCtlrDiskLogCleared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal log cleared." --#TYPE "Internal log cleared" --#SUMMARY "Adapter %s: Internal log cleared (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10654 -- EVT_CTLR_NVRAM_LOG_CLEARED svrTrapCtlrNVRAMLogCleared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "NVRAM log cleared." --#TYPE "NVRAM log cleared" --#SUMMARY "Adapter %s: NVRAM log cleared (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10655 -- EVT_CTLR_REFRESH_UNIQUE_KEY svrTrapCtlrRefreshUniqueKey TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unique key refreshed." --#TYPE "Unique key refreshed" --#SUMMARY "Adapter %s: Unique key refreshed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10656 -- EVT_CTLR_SET_WRITE_CHECK_PARAM svrTrapCtlrSetWriteCheckParam TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write check parameter changed." --#TYPE "Write check parameter changed" --#SUMMARY "Adapter %s: Write check parameter changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10657 -- EVT_CTLR_OP_FAILED svrTrapCtlrOpFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Operation failed." --#TYPE "Operation failed" --#SUMMARY "Adapter %s: Operation failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10658 -- EVT_CTLR_NEW_FIRMWARE_VERSION svrTrapCtlrNewFirmwareVersion TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "New firmware version detected." --#TYPE "New firmware version detected" --#SUMMARY "Adapter %s: New firmware version %s detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10659 -- EVT_CTLR_DG_WITHOUT_LD svrTrapCtlrDGWithoutLD TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Array without logical drive left." --#TYPE "Array without logical drive left" --#SUMMARY "Adapter %s: Array %s without logical drive left (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "There is an array which has no logical drive. Create a logical drive to use the array." --#STATE OPERATIONAL ::= 10660 -- EVT_CTLR_INCORRECT_CALENDAR svrTrapCtlrIncorrectCalendar TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Incorrect calendar parameter detected." --#TYPE "Incorrect calendar parameter detected" --#SUMMARY "Adapter %s: Incorrect calendar parameter detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the scheduler settings." --#STATE OPERATIONAL ::= 10661 -- EVT_LD_COPY_BACK_ABORTED_BBT_OVER svrTrapCtlrSIUBBT TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback on logical drive aborted due to bad block table overflow." --#TYPE "Copyback on logical drive aborted due to bad block table overflow" --#SUMMARY "Adapter %s: Copyback on logical drive %s aborted due to bad block table overflow (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "A large number of uncorrectable bad blocks were detected on logical drive. 1) Restore last good data." --#STATE OPERATIONAL ::= 10662 -- EVT_LD_REDUNDANT_COPY_ABORTED_BBT_OVER svrTrapCtlrSIUBBTEnd TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Redundant copy on logical drive aborted due to bad block table overflow." --#TYPE "Redundant copy on logical drive aborted due to bad block table overflow" --#SUMMARY "Adapter %s: Redundant copy on logical drive %s aborted due to bad block table overflow (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "A large number of uncorrectable bad blocks were detected on logical drive. 1) Restore last good data." --#STATE OPERATIONAL ::= 10663 -- EVT_CTLR_BBT_INIT svrTrapCtlrBBTInit TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table expansion area initialized." --#TYPE "Bad block table expansion area initialized" --#SUMMARY "Adapter %s: Bad block table expansion area initialized (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10664 -- EVT_CTLR_BBT_INIT_FAILED svrTrapCtlrBBTInitFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table expansion area initialization failed." --#TYPE "Bad block table expansion area initialization failed" --#SUMMARY "Adapter %s: Bad block table expansion area initialization failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10665 -- EVT_LD_DISK_ERROR_ON_WRITE svrTrapLDDiskErrorOnWrite TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk error detected by write data on logical drive during redundant copy." --#TYPE "Disk error detected by write data on logical drive during redundant copy" --#SUMMARY "Adapter %s: Disk error detected by write data on logical drive %s during redundant copy (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10666 -- EVT_PD_BAD_BLOCK svrTrapPDBadBlock TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block detected on disk." --#TYPE "Bad block detected on disk" --#SUMMARY "Adapter %s: Bad block detected on disk (%s), %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10667 -- EVT_PD_MULTIDEAD_RECOVERY svrTrapPDMultideadRecovery TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Multiple failure recovery on disk successful." --#TYPE "Multiple failure recovery on disk successful" --#SUMMARY "Adapter %s: Multiple failure recovery on disk (%s) successful (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10668 -- EVT_PD_HS_AVAILABLE svrTrapPDHSAvailable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hot spare available." --#TYPE "Hot spare available" --#SUMMARY "Adapter %s: Hot spare available (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10669 -- EVT_PD_PR_START svrTrapPDPRStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read (one cycle) started on disk." --#TYPE "Patrol Read (one cycle) started on disk" --#SUMMARY "Adapter %s: Patrol Read (one cycle) started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10670 -- EVT_PD_PR_END svrTrapPDPREnd TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read (one cycle) finished on disk." --#TYPE "Patrol Read (one cycle) finished on disk" --#SUMMARY "Adapter %s: Patrol Read (one cycle) finished on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10671 -- EVT_PD_SAS_ERROR svrTrapPDSASError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Error detected on disk." --#TYPE "Error detected on disk" --#SUMMARY "Adapter %s: Error detected on disk (%s), %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10672 -- EVT_PD_SAS_RECOVERED svrTrapPDSASRecovered TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Error recovered on disk." --#TYPE "Error recovered on disk" --#SUMMARY "Adapter %s: Error recovered on disk (%s), %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10673 -- EVT_PD_MEDIA_RECOVERED svrTrapPDMediaRecovered TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Media error recovered on disk by reassigning new block." --#TYPE "Media error recovered on disk by reassigning new block" --#SUMMARY "Adapter %s: Media error recovered on disk (%s) by reassigning new block (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10674 -- EVT_CTLR_PD_MOVE_LD svrTrapCTLRPDMoveLD TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk location in logical drive changed." --#TYPE "Disk location in logical drive changed" --#SUMMARY "Adapter %s: Disk location in logical drive changed from port %s to port %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10675 -- EVT_CTLR_PD_INCR_COLD svrTrapCTLRPDIncrCold TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk increased by cold swap." --#TYPE "Disk increased by cold swap" --#SUMMARY "Adapter %s: Disk increased by cold swap on port %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10676 -- EVT_CTLR_PD_DECR_COLD svrTrapCTLRPDDecrCold TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk decreased by cold swap." --#TYPE "Disk decreased by cold swap" --#SUMMARY "Adapter %s: Disk decreased by cold swap on port %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10677 -- EVT_CTLR_PD_EXCH_COLD svrTrapCTLRPDExchCold TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk exchanged by cold swap." --#TYPE "Disk exchanged by cold swap" --#SUMMARY "Adapter %s: Disk exchanged by cold swap on port %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10678 -- EVT_CTLR_SAS_IFRATE svrTrapCTLRSASIFRate TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS interface rate changed." --#TYPE "SAS interface rate changed" --#SUMMARY "Adapter %s: SAS interface rate changed on port %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10679 -- EVT_CTLR_DRIVER_ERROR svrTrapCtlrDriverError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Driver error." --#TYPE "Driver error" --#SUMMARY "Adapter %s: Driver error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the driver version." --#STATE OPERATIONAL ::= 10680 -- EVT_PD_COPYBACK_START1 svrTrapPDCopybackStart1 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback started on disk." --#TYPE "Copyback started on disk" --#SUMMARY "Adapter %s: Copyback started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10681 -- EVT_PD_COPYBACK_ABORT1 svrTrapPDCopybackAbort1 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback aborted on disk." --#TYPE "Copyback aborted on disk" --#SUMMARY "Adapter %s: Copyback aborted on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10682 -- EVT_PD_COPYBACK_DONE1 svrTrapPDCopybackDone1 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback complete on disk." --#TYPE "Copyback complete on disk" --#SUMMARY "Adapter %s: Copyback complete on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10683 -- EVT_CTLR_INTERNAL_HARD_ERROR1 svrTrapCtlrInternalHardError1 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal hardware error." --#TYPE "Internal hardware error" --#SUMMARY "Adapter %s: Internal hardware error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10684 -- EVT_CTLR_INTERNAL_HARD_ERROR2 svrTrapCtlrInternalHardError2 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal hardware error." --#TYPE "Internal hardware error" --#SUMMARY "Adapter %s: Internal hardware error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10685 -- EVT_PD_BBT_OVERFLOW svrTrapPDBBTOverflow TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk bad block table overflow error." --#TYPE "Disk bad block table overflow error" --#SUMMARY "Adapter %s: Disk (%s) bad block table overflow error (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "A large number of uncorrectable bad blocks were detected on the disk. 1) Restore last good data." --#STATE OPERATIONAL ::= 10686 -- EVT_BBU_REMOTE_CONNECTOR_ERROR svrTrapBBURemoteConnectorError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Error with the remote BBU connector cable detected." --#TYPE "Error with the remote BBU connector cable detected" --#SUMMARY "Adapter %s: Error with the remote BBU connector cable detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace the BBU data/power cable." --#STATE OPERATIONAL ::= 10687 -- EVT_PD_MULTI_FAIL_POST svrTrapPDMultiFailPOST TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Multiple failure on disk detected during POST." --#TYPE "Multiple failure on disk detected during POST" --#SUMMARY "Adapter %s: Multiple failure on disk (%s) detected during POST, internal info %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Replace affected disk. 2) Replace affected backplane or the data cable." --#STATE NONOPERATIONAL ::= 10688 -- EVT_PD_SAS_IFERR_RATE_HIGH svrTrapPDSASIfrateHigh TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failed due to SAS/SATA interface error rate too high." --#TYPE "Disk failed due to SAS/SATA interface error rate too high" --#SUMMARY "Adapter %s: Disk (%s) failed due to SAS/SATA interface error rate too high (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Replace affected disk. 2) Replace affected backplane or the data cable." --#STATE NONOPERATIONAL ::= 10689 -- EVT_PD_OFFLINE_REDUNDANT_COPY_START svrTrapPDMarkedOfflineRedundantCopy TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Operation to mark disk offline (redundant copy) started." --#TYPE "Operation to mark disk offline (redundant copy) started" --#SUMMARY "Adapter %s: Operation to mark disk (%s) offline (redundant copy) started (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10690 -- EVT_LD_REGISTER_MIGRATION svrTrapLDRegisterMigration TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "RAID migration registered for logical drive." --#TYPE "RAID migration registered for logical drive" --#SUMMARY "Adapter %s: RAID migration registered for logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10691 -- EVT_LD_MDC_ABORT_BY_USER svrTrapLDMDCAbortByUser TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MDC aborted by user on logical drive." --#TYPE "MDC aborted by user on logical drive" --#SUMMARY "Adapter %s: MDC aborted by user on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10692 -- EVT_ALARM_SET svrTrapAlarmSet TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Alarm set." --#TYPE "Alarm set" --#SUMMARY "Adapter %s: Alarm set (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10693 -- EVT_LD_DEGRADED_BBT svrTrapLDDegradedBBT TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive degraded due to bad block table overflow." --#TYPE "Logical drive degraded due to bad block table overflow" --#SUMMARY "Adapter %s: Logical drive %s degraded due to bad block table overflow (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "A large number of uncorrectable bad blocks were detected on the disk. 1) Restore last good data." --#STATE DEGRADED ::= 10694 -- EVT_PD_DRIVER_WRITE_ERROR svrTrapPDDriverWriteError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failed due to write error detection by driver." --#TYPE "Disk failed due to write error detection by driver" --#SUMMARY "Adapter %s: Disk (%s) failed due to write error detection by driver (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10695 -- EVT_PD_ABNORMAL_CAPACITY svrTrapPDAbnormalCapacity TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Abnormal capacity of disk in logical drive detected." --#TYPE "Abnormal capacity of disk in logical drive detected" --#SUMMARY "Adapter %s: Abnormal capacity of disk (%s) in logical drive detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the array configuration." --#STATE OPERATIONAL ::= 10696 -- EVT_PD_ABNORMAL_TYPE svrTrapPDAbnormalType TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Illegal type of disk in logical drive detected." --#TYPE "Illegal type of disk in logical drive detected" --#SUMMARY "Adapter %s: Illegal type of disk (%s) in logical drive detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the array configuration." --#STATE OPERATIONAL ::= 10697 -- EVT_LD_NO_BACK_RECOV_BBT_OVER svrTrapLDNoBackRecovBBTOver TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Background recovery of logical drive could not be started due to bad block table overflow." --#TYPE "Background recovery of logical drive could not be started due to bad block table overflow" --#SUMMARY "Adapter %s: Background recovery of logical drive %s could not be started due to bad block table overflow (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10698 -- EVT_HS_PNPADD svrTrapHSDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "New hot spare detected." --#TYPE "New hot spare detected" --#SUMMARY "Adapter %s: New hot spare (%s) detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10699 -- EVT_CTLR_INTERNAL_PCI_HARD_ERROR svrTrapCtlrInternalPCIHardError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal PCI hardware error." --#TYPE "Internal PCI hardware error" --#SUMMARY "Adapter %s: Internal PCI hardware error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected RAID controller." --#STATE OPERATIONAL ::= 10700 -- EVT_PD_BBT_UPDATE svrTrapPDBBTUpdate TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table was updated by disk." --#TYPE "Bad block table was updated by disk" --#SUMMARY "Adapter %s: Bad block table was updated by disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10701 -- EVT_CTLR_PD_INVALID_START svrTrapPDInvalidStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Invalid disk on port during start up detected." --#TYPE "Invalid disk on port during start up detected" --#SUMMARY "Adapter %s: Invalid disk on port %s during start up detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10702 -- EVT_CTLR_PD_INVALID_HOT_SWAP svrTrapPDInvalidHotSwap TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Invalid disk on port during hot swap detected." --#TYPE "Invalid disk on port during hot swap detected" --#SUMMARY "Adapter %s: Invalid disk on port %s during hot swap detected (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10703 -- EVT_PD_SMART_BY_ERROR_THRESHOLD svrTrapPDSMARTByErrorThreshold TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SMART error on disk because internal error threshold on adapter is exceeded." --#TYPE "SMART error on disk because internal error threshold on adapter is exceeded" --#SUMMARY "Adapter %s: SMART error on disk (%s) because internal error threshold on adapter is exceeded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Disk reports a prefailure. The affected disk might fail soon. 1) Replace the disk during next maintenance." --#STATE OPERATIONAL ::= 10704 -- EVT_CTLR_FIRMWARE_DRIVER_MISMATCH svrTrapCtlrFirmwareDriverMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware and driver version mismatch." --#TYPE "Firmware and driver version mismatch" --#SUMMARY "Adapter %s: Firmware and driver version mismatch (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the driver and firmware version." --#STATE OPERATIONAL ::= 10705 -- EVT_CTLR_RESET_RECEIVED svrTrapCtlrResetReceived TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reset received." --#TYPE "Reset received" --#SUMMARY "Adapter %s: Reset received (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10706 -- EVT_PD_OFFLINE_START svrTrapPDOfflineStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Operation to mark disk offline started." --#TYPE "Operation to mark disk offline started" --#SUMMARY "Adapter %s: Operation to mark disk (%s) offline started (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10707 -- EVT_ARRAYS_DELETE_START svrTrapArraysDeleteStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Operation to delete arrays started." --#TYPE "Operation to delete arrays started" --#SUMMARY "Adapter %s: Operation to delete arrays %s started (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10708 -- EVT_LOGICALDRIVE_DELETE_START svrTrapLDDeleteStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Operation to delete logical drive started." --#TYPE "Operation to delete logical drive started" --#SUMMARY "Adapter %s: Operation to delete logical drive %s started (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10709 -- EVT_GLOBAL_HOTSPARE_DELETE_START svrTrapGlobalHotspareDeleteStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Operation to delete global hot spare on disk started." --#TYPE "Operation to delete global hot spare on disk started" --#SUMMARY "Adapter %s: Operation to delete global hot spare on disk (%s) started (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10710 -- EVT_PD_NOT_READY svrTrapPDNotReady TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failed since it never entered ready state." --#TYPE "Disk failed since it never entered ready state" --#SUMMARY "Adapter %s: Disk (%s) failed since it never entered ready state, %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10711 -- EVT_INTERNAL_SOFTWARE_IF_ERROR svrTrapInternalSoftwareIFError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal software interface error." --#TYPE "Internal software interface error" --#SUMMARY "Adapter %s: Internal software interface error (function: %s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: The driver encountered an error. 1) Check the status of the operating system. 2) Reboot your system." --#STATE OPERATIONAL ::= 10712 -- EVT_DEVICE_OPEN_ERROR svrTrapDeviceOpenError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Device open error." --#TYPE "Device open error" --#SUMMARY "Adapter %s: Device open error (device: %s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: The driver encountered an error. 1) Check the status of the operating system. 2) Reboot your system." --#STATE OPERATIONAL ::= 10713 -- EVT_IOCTL_SEND_ERROR svrTrapIoctlSendError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Ioctl send error." --#TYPE "Ioctl send error" --#SUMMARY "Adapter %s: Ioctl send error (details: %s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: The driver encountered an error. 1) Check the status of the operating system. 2) Reboot your system." --#STATE OPERATIONAL ::= 10714 -- EVT_INSUFFICIENT_MEMORY svrTrapInsufficientMemory TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Insufficient application memory." --#TYPE "Insufficient application memory" --#SUMMARY "Adapter %s: Insufficient application memory (function: %s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: The driver encountered an error. 1) Check the status of the operating system. 2) Reboot your system." --#STATE OPERATIONAL ::= 10715 -- EVT_SYS_API_ERROR svrTrapSysAPIError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "System API error." --#TYPE "System API error" --#SUMMARY "Adapter %s: System API error (code: %s, function/item: %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: The driver encountered an error. 1) Check the status of the operating system. 2) Reboot your system." --#STATE OPERATIONAL ::= 10716 -- EVT_FW_INIT_FAILED svrTrapFWInitFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware initialization failed." --#TYPE "Firmware initialization failed" --#SUMMARY "Adapter %s: Firmware initialization failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Replace affected RAID controller." --#STATE NONOPERATIONAL ::= 10717 -- EVT_FW_RECOVERY_FAILED svrTrapFWRecoveryFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware recovery failed." --#TYPE "Firmware recovery failed" --#SUMMARY "Adapter %s: Firmware recovery failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Replace affected RAID controller." --#STATE NONOPERATIONAL ::= 10718 -- EVT_IOCTL_BUSY svrTrapIoctlBusy TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Ioctl busy." --#TYPE "Ioctl busy" --#SUMMARY "Adapter %s: Ioctl busy (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10719 -- EVT_BOOT_LOGICALDRIVE_NUMBER_CHANGED svrTrapBootLogicalDriveNumberChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive number for boot changed." --#TYPE "Logical drive number for boot changed" --#SUMMARY "Adapter %s: Logical drive number for boot changed to %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10720 -- EVT_PD_POWER_STATE_CHANGE_ACTIVE_TO_STOP svrTrapPDPowerStateChangeActiveToStop TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change on disk from active to stopped." --#TYPE "Power state change on disk from active to stopped" --#SUMMARY "Adapter %s: Power state change on disk (%s) from active to stopped (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10721 -- EVT_PD_POWER_STATE_CHANGE_STOP_TO_ACTIVE svrTrapPDPowerStateChangeStopToActive TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change on disk from stopped to active." --#TYPE "Power state change on disk from stopped to active" --#SUMMARY "Adapter %s: Power state change on disk (%s) from stopped to active (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10722 -- EVT_ENCL_ELEMENT_STATUS_CHANGED svrTrapEnclElementStatusChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure element status changed." --#TYPE "Enclosure element status changed" --#SUMMARY "Adapter %s: Enclosure %s element (SES code %s) status changed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10723 -- EVT_CTLR_FIRMWARE_UPDATED svrTrapCtlrFirmwareUpdated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware upload process finished." --#TYPE "Firmware upload process finished" --#SUMMARY "Adapter %s: Firmware upload process finished (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10724 -- EVT_CTLR_PD_FW_UPLOAD_START svrTrapCtlrPDFWUploadStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk firmware update process started." --#TYPE "Disk firmware update process started" --#SUMMARY "Adapter %s: Disk firmware update process started (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10725 -- EVT_CTLR_PD_FW_UPLOAD_END svrTrapCtlrPDFWUploadEnd TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk firmware update process finished." --#TYPE "Disk firmware update process finished" --#SUMMARY "Adapter %s: Disk firmware update process finished (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10726 -- EVT_CTLR_TOD_CHANGED svrTrapCtlrTODChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Difference in time information changed." --#TYPE "Difference in time information changed" --#SUMMARY "Adapter %s: Difference in time information changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10727 -- EVT_CTLR_INIT_FACTORY_SETTINGS svrTrapCtlrInitFactorySettings TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Factory shipment settings initialized." --#TYPE "Factory shipment settings initialized" --#SUMMARY "Adapter %s: Factory shipment settings initialized (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10728 -- EVT_BBU_RECALIBRATION_NEEDED svrTrapBBURecalibrationNeeded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU requires recalibration." --#TYPE "BBU requires recalibration" --#SUMMARY "Adapter %s: BBU requires reconditioning; please initiate recalibration (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Initiate manual recalibration process (e.g. via ServerView RAID Manager). Note: Do not interrupt the charging process by reboots or shutdowns. 2) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10729 -- EVT_PD_NO_REBUILD_HDD_SSD_MIX_NOT_ALLOWED_IN_LD svrTrapNoRebuildHDDSDDMix TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk rebuild not possible as HDD/SSD mix is not supported in an array." --#TYPE "Disk rebuild not possible as HDD/SSD mix is not supported in an array" --#SUMMARY "Adapter %s: Disk (%s) rebuild not possible as HDD/SSD mix is not supported in an array (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10730 -- EVT_PD_NO_COPYBACK_HDD_SSD_MIX_NOT_ALLOWED_IN_LD svrTrapPDNoCopybackHDDSDDMix TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback cannot be started on disk from disk as HDD/SSD mix is not supported in an array." --#TYPE "Copyback cannot be started on disk from disk, as HDD/SSD mix is not supported in an array" --#SUMMARY "Adapter %s: Copyback cannot be started on disk (%s) from disk (%s), as HDD/SSD mix is not supported in an array (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10731 -- EVT_TASK_PROBLEM svrTrapTaskProblem TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Task for object cannot be started. The scheduler will try to start the task again later." --#TYPE "Task for object cannot be started. The scheduler will try to start the task again later" --#SUMMARY "Task %s for object %s cannot be started (error %s). The scheduler will try to start the task again later (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the error code. Then check the controller settings, scheduler settings and disk/logical drive/BBU status." --#STATE OPERATIONAL ::= 10732 -- EVT_TASK_START svrTrapTaskStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Task was started." --#TYPE "Task was started" --#SUMMARY "Task %s for object %s was started by scheduler (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10733 -- EVT_TASK_STOP svrTrapTaskStop TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Task for object cannot be started. The scheduler has disabled the task." --#TYPE "Task for object cannot be started. The scheduler has disabled the task" --#SUMMARY "Task %s for object %s cannot be started (error %s). The scheduler has disabled the task (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check the error code. Then check the controller settings, scheduler settings and disk/logical drive/BBU status." --#STATE NONOPERATIONAL ::= 10734 -- EVT_LD_BBM_LOG_CLEARED svrTrapLDBBMLogCleared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Bad block table of logical drive cleared." --#TYPE "Bad block table of logical drive cleared" --#SUMMARY "Adapter %s: Bad block table of logical drive %s cleared (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10735 -- EVT_SAS_TOPOLOGY_ERROR svrTrapSASTopologyError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "SAS topology error." --#TYPE "SAS topology error" --#SUMMARY "Adapter %s: SAS topology error: %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Unplug affected disk, wait 30 seconds, reinsert it. 2) Replace affected disk. 3) Replace affected backplane or the data cable." --#STATE NONOPERATIONAL ::= 10736 -- EVT_BBU_AUTOMATIC_RECALIBRATION svrTrapBBUAutomaticRecalibration TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU requires recalibration automatically initiated." --#TYPE "BBU requires recalibration automatically initiated" --#SUMMARY "Adapter %s: BBU required reconditioning; recalibration initiated (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10737 -- EVT_TASK_POWER svrTrapTaskPower TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Task for object could not be started at the normal execution time because the service or system was down." --#TYPE "Task for object could not be started at the normal execution time because the service or system was down" --#SUMMARY "Task %s for object %s could not be started at the normal execution time because the service or system was down (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the scheduler settings." --#STATE OPERATIONAL ::= 10738 -- EVT_TASK_SKIP svrTrapTaskSkip TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Task for object cannot be started. The task will be set to the next regular execution time." --#TYPE "Task for object cannot be started. The scheduler will try to start the task again later" --#SUMMARY "Task %s for object %s cannot be started (error %s). The task will be set to the next regular execution time (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check the error code. Then check the controller settings, scheduler settings and disk/logical drive/BBU status." --#STATE OPERATIONAL ::= 10739 -- EVT_LD_CORRECTED_CLUSTER_OF_MEDIUM_ERRORS svrTrapLDCorrectedClusterOfMediumErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cluster of medium errors corrected for logical drive." --#TYPE "Cluster of medium errors corrected for logical drive" --#SUMMARY "Adapter %s: Cluster of medium errors corrected for logical drive %s at %s (on disk %s at %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10740 -- EVT_CTRL_HOST_BUS_SCAN_REQUESTED svrTrapCtrlHostBusScanRequested TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Host bus rescan requested." --#TYPE "Host bus rescan requested" --#SUMMARY "Adapter %s: Host bus rescan requested (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10741 -- EVT_CTRL_FACTORY_REPURPOSED svrTrapCtrlFactoryRepurposed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter repurposed and factory defaults restored." --#TYPE "Adapter repurposed and factory defaults restored" --#SUMMARY "Adapter %s: Adapter repurposed and factory defaults restored (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10742 -- EVT_CTRL_LOCK_KEY_BINDING_UPDATED svrTrapCtrlLockKeyBindingUpdated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security key binding updated." --#TYPE "Disk security key binding updated" --#SUMMARY "Adapter %s: Disk security key binding updated (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10743 -- EVT_PD_STATE_CHANGE_AVAIL_TO_CB svrTrapPDStateChangeAvailToCB TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from available to copyback." --#TYPE "State change from available to copyback" --#SUMMARY "Adapter %s: State change on disk (%s) from available to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10744 -- EVT_PD_STATE_CHANGE_AVAIL_TO_SYS svrTrapPDStateChangeAvailToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from available to JBOD." --#TYPE "State change from available to JBOD" --#SUMMARY "Adapter %s: State change on disk (%s) from available to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10745 -- EVT_PD_STATE_CHANGE_FAIL_TO_CB svrTrapPDStateChangeFailToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to copyback." --#TYPE "State change from failed to copyback" --#SUMMARY "Adapter %s: State change on disk (%s) from failed to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10746 -- EVT_PD_STATE_CHANGE_FAIL_TO_SYS svrTrapPDStateChangeFailToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to JBOD." --#TYPE "State change from failed to JBOD" --#SUMMARY "Adapter %s: State change on disk (%s) from failed to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10747 -- EVT_PD_STATE_CHANGE_HS_TO_CB svrTrapPDStateChangeHsToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from hot spare to copyback." --#TYPE "State change from hot spare to copyback" --#SUMMARY "Adapter %s: State change on disk (%s) from hot spare to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10748 -- EVT_PD_STATE_CHANGE_HS_TO_SYS svrTrapPDStateChangeHsToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from hot spare to JBOD." --#TYPE "State change from hot spare to JBOD" --#SUMMARY "Adapter %s: State change on disk (%s) from hot spare to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10749 -- EVT_PD_STATE_CHANGE_RBLD_TO_CB svrTrapPDStateChangeRbldToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from rebuilding to copyback." --#TYPE "State change from rebuilding to copyback" --#SUMMARY "Adapter %s: State change on disk (%s) from rebuilding to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10750 -- EVT_PD_STATE_CHANGE_RBLD_TO_SYS svrTrapPDStateChangeRbldToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from rebuilding to JBOD." --#TYPE "State change from rebuilding to JBOD" --#SUMMARY "Adapter %s: State change on disk (%s) from rebuilding to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10751 -- EVT_PD_STATE_CHANGE_OP_TO_CB svrTrapPDStateChangeOpToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to copyback." --#TYPE "State change from operational to copyback" --#SUMMARY "Adapter %s: State change on disk (%s) from operational to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10752 -- EVT_PD_STATE_CHANGE_OP_TO_SYS svrTrapPDStateChangeOpToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to JBOD." --#TYPE "State change from operational to JBOD" --#SUMMARY "Adapter %s: State change on disk (%s) from operational to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10753 -- EVT_PD_STATE_CHANGE_CB_TO_AVAIL svrTrapPDStateChangeCbToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from copyback to available." --#TYPE "State change from copyback to available" --#SUMMARY "Adapter %s: State change on disk (%s) from copyback to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10754 -- EVT_PD_STATE_CHANGE_CB_TO_FAIL svrTrapPDStateChangeCbToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from copyback to failed." --#TYPE "State change from copyback to failed" --#SUMMARY "Adapter %s: State change on disk (%s) from copyback to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10755 -- EVT_PD_STATE_CHANGE_CB_TO_HS svrTrapPDStateChangeCbToHs TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from copyback to hot spare." --#TYPE "State change from copyback to hot spare" --#SUMMARY "Adapter %s: State change on disk (%s) from copyback to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10756 -- EVT_PD_STATE_CHANGE_CB_TO_OFFL svrTrapPDStateChangeCbToOffl TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from copyback to offline." --#TYPE "State change from copyback to offline" --#SUMMARY "Adapter %s: State change on disk (%s) from copyback to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10757 -- EVT_PD_STATE_CHANGE_CB_TO_OP svrTrapPDStateChangeCbToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from copyback to operational." --#TYPE "State change from copyback to operational" --#SUMMARY "Adapter %s: State change on disk (%s) from copyback to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10758 -- EVT_PD_STATE_CHANGE_CB_TO_RBLD svrTrapPDStateChangeCbToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from copyback to rebuilding." --#TYPE "State change from copyback to rebuilding" --#SUMMARY "Adapter %s: State change on disk (%s) from copyback to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10759 -- EVT_PD_STATE_CHANGE_CB_TO_CB svrTrapPDStateChangeCbToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from copyback to copyback." --#TYPE "State change from copyback to copyback" --#SUMMARY "Adapter %s: State change on disk (%s) from copyback to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10760 -- EVT_PD_STATE_CHANGE_CB_TO_SYS svrTrapPDStateChangeCbToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from copyback to JBOD." --#TYPE "State change from copyback to JBOD" --#SUMMARY "Adapter %s: State change on disk (%s) from copyback to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10761 -- EVT_PD_STATE_CHANGE_SYS_TO_AVAIL svrTrapPDStateChangeSysToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from JBOD to available." --#TYPE "State change from JBOD to available" --#SUMMARY "Adapter %s: State change on disk (%s) from JBOD to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10762 -- EVT_PD_STATE_CHANGE_SYS_TO_FAIL svrTrapPDStateChangeSysToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from JBOD to failed." --#TYPE "State change from JBOD to failed" --#SUMMARY "Adapter %s: State change on disk (%s) from JBOD to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10763 -- EVT_PD_STATE_CHANGE_SYS_TO_HS svrTrapPDStateChangeSysToHs TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from JBOD to hot spare." --#TYPE "State change from JBOD to hot spare" --#SUMMARY "Adapter %s: State change on disk (%s) from JBOD to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10764 -- EVT_PD_STATE_CHANGE_SYS_TO_OFFL svrTrapPDStateChangeSysToOffl TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from JBOD to offline." --#TYPE "State change from JBOD to offline" --#SUMMARY "Adapter %s: State change on disk (%s) from JBOD to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE NONOPERATIONAL ::= 10765 -- EVT_PD_STATE_CHANGE_SYS_TO_OP svrTrapPDStateChangeSysToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from JBOD to operational." --#TYPE "State change from JBOD to operational" --#SUMMARY "Adapter %s: State change on disk (%s) from JBOD to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10766 -- EVT_PD_STATE_CHANGE_SYS_TO_RBLD svrTrapPDStateChangeSysToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from JBOD to rebuilding." --#TYPE "State change from JBOD to rebuilding" --#SUMMARY "Adapter %s: State change on disk (%s) from JBOD to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10767 -- EVT_PD_STATE_CHANGE_SYS_TO_CB svrTrapPDStateChangeSysToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from JBOD to copyback." --#TYPE "State change from JBOD to copyback" --#SUMMARY "Adapter %s: State change on disk (%s) from JBOD to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10768 -- EVT_PD_STATE_CHANGE_SYS_TO_SYS svrTrapPDStateChangeSysToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from JBOD to JBOD." --#TYPE "State change from JBOD to JBOD" --#SUMMARY "Adapter %s: State change on disk (%s) from JBOD to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10769 -- EVT_PD_STATE_CHANGE_BY_USER_AVAIL_TO_CB svrTrapPDStateChangeByUserAvailToCB TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from available to copyback." --#TYPE "State change by user from available to copyback" --#SUMMARY "Adapter %s: State change by user on disk (%s) from available to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10770 -- EVT_PD_STATE_CHANGE_BY_USER_AVAIL_TO_SYS svrTrapPDStateChangeByUserAvailToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from available to JBOD." --#TYPE "State change by user from available to JBOD" --#SUMMARY "Adapter %s: State change by user on disk (%s) from available to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10771 -- EVT_PD_STATE_CHANGE_BY_USER_FAIL_TO_CB svrTrapPDStateChangeByUserFailToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from failed to copyback." --#TYPE "State change by user from failed to copyback" --#SUMMARY "Adapter %s: State change by user on disk (%s) from failed to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10772 -- EVT_PD_STATE_CHANGE_BY_USER_FAIL_TO_SYS svrTrapPDStateChangeByUserFailToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from failed to JBOD." --#TYPE "State change by user from failed to JBOD" --#SUMMARY "Adapter %s: State change by user on disk (%s) from failed to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10773 -- EVT_PD_STATE_CHANGE_BY_USER_HS_TO_CB svrTrapPDStateChangeByUserHsToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from hot spare to copyback." --#TYPE "State change by user from hot spare to copyback" --#SUMMARY "Adapter %s: State change by user on disk (%s) from hot spare to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10774 -- EVT_PD_STATE_CHANGE_BY_USER_HS_TO_SYS svrTrapPDStateChangeByUserHsToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from hot spare to JBOD." --#TYPE "State change by user from hot spare to JBOD" --#SUMMARY "Adapter %s: State change by user on disk (%s) from hot spare to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10775 -- EVT_PD_STATE_CHANGE_BY_USER_RBLD_TO_CB svrTrapPDStateChangeByUserRbldToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from rebuilding to copyback." --#TYPE "State change by user from rebuilding to copyback" --#SUMMARY "Adapter %s: State change by user on disk (%s) from rebuilding to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10776 -- EVT_PD_STATE_CHANGE_BY_USER_RBLD_TO_SYS svrTrapPDStateChangeByUserRbldToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from rebuilding to JBOD." --#TYPE "State change by user from rebuilding to JBOD" --#SUMMARY "Adapter %s: State change by user on disk (%s) from rebuilding to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10777 -- EVT_PD_STATE_CHANGE_BY_USER_OP_TO_CB svrTrapPDStateChangeByUserOpToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from operational to copyback." --#TYPE "State change by user from operational to copyback" --#SUMMARY "Adapter %s: State change by user on disk (%s) from operational to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10778 -- EVT_PD_STATE_CHANGE_BY_USER_OP_TO_SYS svrTrapPDStateChangeByUserOpToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from operational to JBOD." --#TYPE "State change by user from operational to JBOD" --#SUMMARY "Adapter %s: State change by user on disk (%s) from operational to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10779 -- EVT_PD_STATE_CHANGE_BY_USER_CB_TO_AVAIL svrTrapPDStateChangeByUserCbToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from copyback to available." --#TYPE "State change by user from copyback to available" --#SUMMARY "Adapter %s: State change by user on disk (%s) from copyback to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10780 -- EVT_PD_STATE_CHANGE_BY_USER_CB_TO_FAIL svrTrapPDStateChangeByUserCbToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from copyback to failed." --#TYPE "State change by user from copyback to failed" --#SUMMARY "Adapter %s: State change by user on disk (%s) from copyback to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10781 -- EVT_PD_STATE_CHANGE_BY_USER_CB_TO_HS svrTrapPDStateChangeByUserCbToHs TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from copyback to hot spare." --#TYPE "State change by user from copyback to hot spare" --#SUMMARY "Adapter %s: State change by user on disk (%s) from copyback to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10782 -- EVT_PD_STATE_CHANGE_BY_USER_CB_TO_OFFL svrTrapPDStateChangeByUserCbToOffl TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from copyback to offline." --#TYPE "State change by user from copyback to offline" --#SUMMARY "Adapter %s: State change by user on disk (%s) from copyback to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10783 -- EVT_PD_STATE_CHANGE_BY_USER_CB_TO_OP svrTrapPDStateChangeByUserCbToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from copyback to operational." --#TYPE "State change by user from copyback to operational" --#SUMMARY "Adapter %s: State change by user on disk (%s) from copyback to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10784 -- EVT_PD_STATE_CHANGE_BY_USER_CB_TO_RBLD svrTrapPDStateChangeByUserCbToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from copyback to rebuilding." --#TYPE "State change by user from copyback to rebuilding" --#SUMMARY "Adapter %s: State change by user on disk (%s) from copyback to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10785 -- EVT_PD_STATE_CHANGE_BY_USER_CB_TO_CB svrTrapPDStateChangeByUserCbToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from copyback to copyback." --#TYPE "State change by user from copyback to copyback" --#SUMMARY "Adapter %s: State change by user on disk (%s) from copyback to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10786 -- EVT_PD_STATE_CHANGE_BY_USER_CB_TO_SYS svrTrapPDStateChangeByUserCbToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from copyback to JBOD." --#TYPE "State change by user from copyback to JBOD" --#SUMMARY "Adapter %s: State change by user on disk (%s) from copyback to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10787 -- EVT_PD_STATE_CHANGE_BY_USER_SYS_TO_AVAIL svrTrapPDStateChangeByUserSysToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from JBOD to available." --#TYPE "State change by user from JBOD to available" --#SUMMARY "Adapter %s: State change by user on disk (%s) from JBOD to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10788 -- EVT_PD_STATE_CHANGE_BY_USER_SYS_TO_FAIL svrTrapPDStateChangeByUserSysToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from JBOD to failed." --#TYPE "State change by user from JBOD to failed" --#SUMMARY "Adapter %s: State change by user on disk (%s) from JBOD to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE NONOPERATIONAL ::= 10789 -- EVT_PD_STATE_CHANGE_BY_USER_SYS_TO_HS svrTrapPDStateChangeByUserSysToHs TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from JBOD to hot spare." --#TYPE "State change by user from JBOD to hot spare" --#SUMMARY "Adapter %s: State change by user on disk (%s) from JBOD to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10790 -- EVT_PD_STATE_CHANGE_BY_USER_SYS_TO_OFFL svrTrapPDStateChangeByUserSysToOffl TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from JBOD to offline." --#TYPE "State change by user from JBOD to offline" --#SUMMARY "Adapter %s: State change by user on disk (%s) from JBOD to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE DEGRADED ::= 10791 -- EVT_PD_STATE_CHANGE_BY_USER_SYS_TO_OP svrTrapPDStateChangeByUserSysToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from JBOD to operational." --#TYPE "State change by user from JBOD to operational" --#SUMMARY "Adapter %s: State change by user on disk (%s) from JBOD to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10792 -- EVT_PD_STATE_CHANGE_BY_USER_SYS_TO_RBLD svrTrapPDStateChangeByUserSysToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from JBOD to rebuilding." --#TYPE "State change by user from JBOD to rebuilding" --#SUMMARY "Adapter %s: State change by user on disk (%s) from JBOD to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10793 -- EVT_PD_STATE_CHANGE_BY_USER_SYS_TO_CB svrTrapPDStateChangeByUserSysToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from JBOD to copyback." --#TYPE "State change by user from JBOD to copyback" --#SUMMARY "Adapter %s: State change by user on disk (%s) from JBOD to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10794 -- EVT_PD_STATE_CHANGE_BY_USER_SYS_TO_SYS svrTrapPDStateChangeByUserSysToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from JBOD to JBOD." --#TYPE "State change by user from JBOD to JBOD" --#SUMMARY "Adapter %s: State change by user on disk (%s) from JBOD to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10795 -- EVT_PD_STATE_CHANGE_OFFL_TO_CB svrTrapPDStateChangeOfflToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from offline to copyback." --#TYPE "State change from offline to copyback" --#SUMMARY "Adapter %s: State change on disk (%s) from offline to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10796 -- EVT_PD_STATE_CHANGE_BY_USER_OFFL_TO_CB svrTrapPDStateChangeByUserOfflToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from offline to copyback." --#TYPE "State change by user from offline to copyback" --#SUMMARY "Adapter %s: State change by user on disk (%s) from offline to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10797 -- EVT_PD_STATE_CHANGE_OFFL_TO_SYS svrTrapPDStateChangeOfflToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from offline to JBOD." --#TYPE "State change from offline to JBOD" --#SUMMARY "Adapter %s: State change on disk (%s) from offline to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10798 -- EVT_PD_STATE_CHANGE_BY_USER_OFFL_TO_SYS svrTrapPDStateChangeByUserOfflToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from offline to JBOD." --#TYPE "State change by user from offline to JBOD" --#SUMMARY "Adapter %s: State change by user on disk (%s) from offline to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10799 -- EVT_CTRL_LOCK_KEY_EKM_MODE svrTrapCtrlLockKeyEKMMode TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security is in external key management mode." --#TYPE "Disk security is in external key management mode" --#SUMMARY "Adapter %s: Disk security is in external key management mode (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10800 -- EVT_CTRL_LOCK_KEY_EKM_FAILURE svrTrapCtrlLockKeyEKMFailure TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk security failed to communicate with external key management system." --#TYPE "Disk security failed to communicate with external key management system" --#SUMMARY "Adapter %s: Disk security failed to communicate with external key management system (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10801 -- EVT_PD_LOCK_KEY_REQUIRED svrTrapPDLockKeyRequired TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk needs key." --#TYPE "Disk needs key" --#SUMMARY "Adapter %s: Disk (%s) needs key to be %s %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10802 -- EVT_LD_SECURE_FAILED svrTrapLDSecureFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive secure failed." --#TYPE "Logical drive secure failed" --#SUMMARY "Adapter %s: Logical drive %s secure failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10803 -- EVT_CTRL_ONLINE_RESET svrTrapCtrlOnlineReset TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Controller encountered a fatal error and was reset." --#TYPE "Controller encountered a fatal error and was reset" --#SUMMARY "Adapter %s: Controller encountered a fatal error and was reset (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Replace affected RAID controller." --#STATE OPERATIONAL ::= 10804 -- EVT_CFG_CMD_LOST svrTrapCfgCmdLost TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Configuration command could not be committed to disk." --#TYPE "Configuration command could not be committed to disk" --#SUMMARY "Adapter %s: Configuration command could not be committed to disk, please retry (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10805 -- EVT_PD_COD_STALE svrTrapPDCODStale TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "COD on disk updated as it was stale." --#TYPE "COD on disk updated as it was stale" --#SUMMARY "Adapter %s: COD on disk (%s) updated as it was stale (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10806 -- EVT_PD_POWER_STATE_CHANGE_ACTIVE_TO_STOP_FAILED svrTrapPDPowerStateChangeActiveToStopFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change failed on disk (from active to stopped)." --#TYPE "Power state change failed on disk (from active to stopped)" --#SUMMARY "Adapter %s: Power state change failed on disk (%s) (from active to stopped) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10807 -- EVT_PD_POWER_STATE_CHANGE_STOP_TO_ACTIVE_FAILED svrTrapPDPowerStateChangeStopToActiveFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change failed on disk (from stopped to active)." --#TYPE "Power state change failed on disk (from stopped to active)" --#SUMMARY "Adapter %s: Power state change failed on disk (%s) (from stopped to active) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10808 -- EVT_LD_NOT_READY svrTrapLDNotReady TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is not ready." --#TYPE "Logical drive is not ready" --#SUMMARY "Adapter %s: Logical drive %s is not ready (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10809 -- EVT_LD_IS_READY svrTrapLDIsReady TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is ready." --#TYPE "Logical drive is ready" --#SUMMARY "Adapter %s: Logical drive %s is ready (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10810 -- EVT_MAIL_SUCCESSFULLY_SENT svrTrapMailSuccessfullySent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Test E-mail was sent successfully." --#TYPE "Test E-mail was sent successfully" --#SUMMARY "Test E-mail was sent successfully (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10811 -- EVT_ADAPTER_REPLACED svrTrapAdapterReplaced TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter has been replaced during reboot." --#TYPE "Adapter has been replaced during reboot" --#SUMMARY "Adapter %s: Adapter has been replaced during reboot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10812 -- EVT_ENCL_POWER_REMOVED svrTrapEnclPowerRemoved TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure power supply removed." --#TYPE "Enclosure power supply removed" --#SUMMARY "Adapter %s: Enclosure %s power supply %s removed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10813 -- EVT_ENCL_POWER_SUPPLY_OFF svrTrapEnclPowerSupplyOff TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure power supply turned off." --#TYPE "Enclosure power supply turned off" --#SUMMARY "Adapter %s: Enclosure %s power supply %s turned off (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10814 -- EVT_ENCL_POWER_INSERTED svrTrapEnclPowerInserted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure power supply inserted." --#TYPE "Enclosure power supply inserted" --#SUMMARY "Adapter %s: Enclosure %s power supply %s inserted (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10815 -- EVT_ENCL_POWER_SUPPLY_ON svrTrapEnclPowerSupplyOn TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure power supply turned on." --#TYPE "Enclosure power supply turned on" --#SUMMARY "Adapter %s: Enclosure %s power supply %s turned on (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10816 -- EVT_ENCL_TEMPERATURE_BELOW_WARNING svrTrapEnclTemperatureBelowWarning TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure temperature sensor below warning threshold." --#TYPE "Enclosure temperature sensor below warning threshold" --#SUMMARY "Adapter %s: Enclosure %s temperature sensor %s below warning threshold (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Check environmental temperature." --#STATE OPERATIONAL ::= 10817 -- EVT_ENCL_TEMPERATURE_BELOW_ERROR svrTrapEnclTemperatureBelowError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure temperature sensor below error threshold." --#TYPE "Enclosure temperature sensor below error threshold" --#SUMMARY "Adapter %s: Enclosure %s temperature sensor %s below error threshold (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check environmental temperature." --#STATE OPERATIONAL ::= 10818 -- EVT_ENCL_TEMPERATURE_ABOVE_WARNING svrTrapEnclTemperatureAboveWarning TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure temperature sensor above warning threshold." --#TYPE "Enclosure temperature sensor above warning threshold" --#SUMMARY "Adapter %s: Enclosure %s temperature sensor %s above warning threshold (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Check installation of all air flow channels, closed housing, and unblocked louvers. 2) Check environmental temperature." --#STATE OPERATIONAL ::= 10819 -- EVT_ENCL_TEMPERATURE_ABOVE_ERROR svrTrapEnclTemperatureAboveError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure temperature sensor above error threshold." --#TYPE "Enclosure temperature sensor above error threshold" --#SUMMARY "Adapter %s: Enclosure %s temperature sensor %s above error threshold (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Check installation of all air flow channels, closed housing, and unblocked louvers. 2) Check environmental temperature." --#STATE OPERATIONAL ::= 10820 -- EVT_PD_POWER_STATE_CHANGE_ACTIVE_TO_TRANSITION svrTrapPDPowerStateChangeActiveToTransition TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change on disk from active to transition." --#TYPE "Power state change on disk from active to transition" --#SUMMARY "Adapter %s: Power state change on disk (%s) from active to transition (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10821 -- EVT_PD_POWER_STATE_CHANGE_ACTIVE_TO_TRANSITION_FAILED svrTrapPDPowerStateChangeChangeActiveToTransitionFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change failed on disk (from active to transition)." --#TYPE "Power state change failed on disk (from active to transition)" --#SUMMARY "Adapter %s: Power state change failed on disk (%s) (from active to transition) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10822 -- EVT_PD_POWER_STATE_CHANGE_STOP_TO_TRANSITION svrTrapPDPowerStateChangeStopToTransition TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change on disk from stopped to transition." --#TYPE "Power state change on disk from stopped to transition" --#SUMMARY "Adapter %s: Power state change on disk (%s) from stopped to transition (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10823 -- EVT_PD_POWER_STATE_CHANGE_STOP_TO_TRANSITION_FAILED svrTrapPDPowerStateChangeChangeStopToTransitionFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change failed on disk (from stopped to transition)." --#TYPE "Power state change failed on disk (from stopped to transition)" --#SUMMARY "Adapter %s: Power state change failed on disk (%s) (from stopped to transition) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10824 -- EVT_PD_POWER_STATE_CHANGE_TRANSITION_TO_ACTIVE svrTrapPDPowerStateChangeTransitionToActive TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change on disk from transition to active." --#TYPE "Power state change on disk from transition to active" --#SUMMARY "Adapter %s: Power state change on disk (%s) from transition to active (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10825 -- EVT_PD_POWER_STATE_CHANGE_TRANSITION_TO_ACTIVE_FAILED svrTrapPDPowerStateChangeChangeTransitionToActiveFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change failed on disk (from transition to active)." --#TYPE "Power state change failed on disk (from transition to active)" --#SUMMARY "Adapter %s: Power state change failed on disk (%s) (from transition to active) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10826 -- EVT_PD_POWER_STATE_CHANGE_TRANSITION_TO_STOP svrTrapPDPowerStateChangeTransitionToStop TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change on disk from transition to stopped." --#TYPE "Power state change on disk from transition to stopped" --#SUMMARY "Adapter %s: Power state change on disk (%s) from transition to stopped (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10827 -- EVT_PD_POWER_STATE_CHANGE_TRANSITION_TO_STOP_FAILED svrTrapPDPowerStateChangeChangeTransitionToStopFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power state change failed on disk (from transition to stopped)." --#TYPE "Power state change failed on disk (from transition to stopped)" --#SUMMARY "Adapter %s: Power state change failed on disk (%s) (from transition to stopped) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10828 -- EVT_CTRL_RESET_EXPANDER svrTrapCtrlResetExpander TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reset on-board expander." --#TYPE "Reset on-board expander" --#SUMMARY "Adapter %s: Reset on-board expander (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10829 -- EVT_ENCL_TEMPERATURE_INCREASE svrTrapEnclTemperatureIncrease TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure temperature sensor temperature increase detected." --#TYPE "Enclosure temperature sensor temperature increase detected" --#SUMMARY "Adapter %s: Enclosure %s temperature sensor %s temperature increase detected (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10830 -- EVT_ENCL_TEMPERATURE_DROP svrTrapEnclTemperatureDrop TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure temperature sensor temperature drop detected." --#TYPE "Enclosure temperature sensor temperature drop detected" --#SUMMARY "Adapter %s: Enclosure %s temperature sensor %s temperature drop detected (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10831 -- EVT_ENCL_FAN_SPEED_LOW svrTrapEnclFanSpeedLow TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure fan speed changed to low." --#TYPE "Enclosure fan speed changed to low" --#SUMMARY "Adapter %s: Enclosure %s fan %s speed changed to low (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10832 -- EVT_ENCL_FAN_SPEED_MEDIUM svrTrapEnclFanSpeedMedium TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure fan speed changed to medium." --#TYPE "Enclosure fan speed changed to medium" --#SUMMARY "Adapter %s: Enclosure %s fan %s speed changed to medium (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10833 -- EVT_ENCL_FAN_SPEED_HIGH svrTrapEnclFanSpeedHigh TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Enclosure fan speed changed to high." --#TYPE "Enclosure fan speed changed to high" --#SUMMARY "Adapter %s: Enclosure %s fan %s speed changed to high (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10834 -- EVT_PD_OFFLINE_EXCESSIVE_PHY_ERRORS svrTrapPDOfflineExcessivePhyErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk will be set offline due to SAS/SATA interface error rate too high." --#TYPE "Disk will be set offline due to SAS/SATA interface error rate too high" --#SUMMARY "Adapter %s: Disk (%s) will be set offline due to SAS/SATA interface error rate too high (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10835 -- EVT_PD_WRITE_CACHE_ENABLED svrTrapPDWriteCacheEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write cache on disk enabled." --#TYPE "Write cache on disk enabled" --#SUMMARY "Adapter %s: Write cache on disk (%s) enabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10836 -- EVT_PD_WRITE_CACHE_DISABLED svrTrapPDWriteCacheDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write cache on disk disabled." --#TYPE "Write cache on disk disabled" --#SUMMARY "Adapter %s: Write cache on disk (%s) disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10837 -- EVT_PD_NCQ_ENABLED svrTrapPDNCQEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Native Command Queuing on disk enabled." --#TYPE "Native Command Queuing on disk enabled" --#SUMMARY "Adapter %s: Native Command Queuing (NCQ) on disk (%s) enabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10838 -- EVT_PD_NCQ_DISABLED svrTrapPDNCQDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Native Command Queuing on disk disabled." --#TYPE "Native Command Queuing on disk disabled" --#SUMMARY "Adapter %s: Native Command Queuing (NCQ) on disk (%s) disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10839 -- EVT_AUTO_REBUILD_HOTSPARE svrTrapAutoRebuildHotspare TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic rebuild will use hot spares." --#TYPE "Automatic rebuild will use hot spares" --#SUMMARY "Adapter %s: Automatic rebuild will use hot spares (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10840 -- EVT_AUTO_REBUILD_AVAILABLE_HOTSPARE svrTrapAutoRebuildAvailableHotspare TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Automatic rebuild will use available disks and hot spares." --#TYPE "Automatic rebuild will use available disks and hot spares" --#SUMMARY "Adapter %s: Automatic rebuild will use available disks and hot spares (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10841 -- EVT_PATROL_READ_RATE_CHANGED svrTrapPatrolReadRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read rate changed." --#TYPE "Patrol Read rate changed" --#SUMMARY "Adapter %s: Patrol Read rate changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10842 -- EVT_MIGRATION_RATE_CHANGED svrTrapMigrationRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Migration rate changed." --#TYPE "Migration rate changed" --#SUMMARY "Adapter %s: Migration rate changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10843 -- EVT_INITIALIZATION_RATE_CHANGED svrTrapInitializationRateChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization rate changed." --#TYPE "Initialization rate changed" --#SUMMARY "Adapter %s: Initialization rate changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10844 -- EVT_CHECK_RESUMED svrTrapConsistencyCheckContinuedOnLogicalDrive TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check resumed on logical drive." --#TYPE "Consistency check resumed on logical drive" --#SUMMARY "Adapter %s: Consistency check resumed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10845 -- EVT_CHECK_REJECTED svrTrapConsistencyCheckRejectedOnLogicalDrive TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Consistency check rejected on uninitialized logical drive." --#TYPE "Consistency check rejected on uninitialized logical drive" --#SUMMARY "Adapter %s: Consistency check rejected on uninitialized logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Initiate manual MDC to initialize the logical drive." --#STATE OPERATIONAL ::= 10846 -- EVT_INITIALIZATION_PAUSED svrTrapLDInitPaused TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization suspended on logical drive." --#TYPE "Initialization suspended on logical drive" --#SUMMARY "Adapter %s: Initialization suspended on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10847 -- EVT_INITIALIZATION_RESUMED svrTrapLDInitResumed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization resumed on logical drive." --#TYPE "Initialization resumed on logical drive" --#SUMMARY "Adapter %s: Initialization resumed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10848 -- EVT_LD_IS_SSC svrTrapLDIsSSC TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is used for CacheCade." --#TYPE "Logical drive is used for CacheCade" --#SUMMARY "Adapter %s: Logical drive %s is used for CacheCade with capacity %s MB (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10849 -- EVT_LD_IS_USING_SSC svrTrapLDIsUsingSSC TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is using CacheCade." --#TYPE "Logical drive is using CacheCade" --#SUMMARY "Adapter %s: Logical drive %s is using CacheCade %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10850 -- EVT_LD_IS_NOT_USING_SSC svrTrapLDIsNotUsingSSC TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is no longer using CacheCade." --#TYPE "Logical drive is no longer using CacheCade" --#SUMMARY "Adapter %s: Logical drive %s is no longer using CacheCade %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10851 -- EVT_LD_SSC_SIZE_CHANGED svrTrapLDSSCSizeChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "CacheCade capacity changed." --#TYPE "CacheCade capacity changed" --#SUMMARY "Adapter %s: CacheCade %s capacity changed and is now %s MB (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10852 -- EVT_BBU_CANNOT_DO_TRANSPARENT_LEARN svrTrapBBUCannotDoTransparentLearn TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU life has degraded and cannot initiate transparent learn cycles." --#TYPE "BBU life has degraded and cannot initiate transparent learn cycles" --#SUMMARY "Adapter %s: BBU life has degraded and cannot initiate transparent learn cycles (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Initiate manual relearn cycle. 2) If problem persists replace BBU." --#STATE OPERATIONAL ::= 10853 -- EVT_CTRL_PFK_APPLIED svrTrapCtrlPFKApplied TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MegaRAID Advanced Software Options key applied." --#TYPE "MegaRAID Advanced Software Options key applied" --#SUMMARY "Adapter %s: MegaRAID Advanced Software Options (%s) key applied (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10854 -- EVT_CTRL_PFK_TRANSFERRED svrTrapCtrlPFKTransferred TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MegaRAID Advanced Software Options key transferred." --#TYPE "MegaRAID Advanced Software Options key transferred" --#SUMMARY "Adapter %s: MegaRAID Advanced Software Options (%s) key transferred (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10855 -- EVT_CTRL_PFK_SERIALNUM svrTrapCtrlPFKSerialnum TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MegaRAID Advanced Software Options serial number." --#TYPE "MegaRAID Advanced Software Options serial number" --#SUMMARY "Adapter %s: MegaRAID Advanced Software Options serial number %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10856 -- EVT_CTRL_PFK_SERIALNUM_MISMATCH svrTrapCtrlPFKSerialnumMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MegaRAID Advanced Software Options serial number mismatch." --#TYPE "MegaRAID Advanced Software Options serial number mismatch" --#SUMMARY "Adapter %s: MegaRAID Advanced Software Options serial number mismatch. Key Vault serial number is %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Controller serial number does not match with MegaRAID Advanced Software Options key. Apply key to appropriate controller." --#STATE OPERATIONAL ::= 10857 -- EVT_BBU_REPLACEMENT_NEEDED_SOH_NOT_OPTIMAL svrTrapBBUReplacementNeededSOHNotOptimal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU cannot support data retention." --#TYPE "BBU cannot support data retention" --#SUMMARY "Adapter %s: BBU cannot support data retention for more than %s hours (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "BBU capacity is decreased and buffering of data in controller cache is limited. To reach full data retention time replace BBU." --#STATE OPERATIONAL ::= 10858 -- EVT_LD_POWER_STATE_CHANGE svrTrapLDPowerStateChange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive power policy changed." --#TYPE "Logical drive power policy changed" --#SUMMARY "Adapter %s: Logical drive %s: %s changed (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10859 -- EVT_LD_POWER_STATE_MAX_UNAVAILABLE svrTrapLDPowerStateMaxUnavailable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive cannot transition to maximum power savings." --#TYPE "Logical drive cannot transition to maximum power savings" --#SUMMARY "Adapter %s: Logical drive %s cannot transition to maximum power savings (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10860 -- EVT_CTRL_HOST_DRIVER_LOADED svrTrapCtrlHostDriverLoaded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Driver is loaded and operational." --#TYPE "Driver is loaded and operational" --#SUMMARY "Adapter %s: Driver is loaded and operational (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10861 -- EVT_LD_MIRROR_BROKEN svrTrapLDMirrorBroken TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive mirror broken." --#TYPE "Logical drive mirror broken" --#SUMMARY "Adapter %s: Logical drive %s mirror broken (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10862 -- EVT_LD_MIRROR_JOINED svrTrapLDMirrorJoined TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive mirror joined." --#TYPE "Logical drive mirror joined" --#SUMMARY "Adapter %s: Logical drive %s mirror joined (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10863 -- EVT_PD_SAS_WIDE_PORT_LINK_FAILURE svrTrapPDSASWidePortLinkFailure TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk link failed in SAS wide port." --#TYPE "Disk link failed in SAS wide port" --#SUMMARY "Adapter %s: Disk (%s) link %s failed in SAS wide port (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Unplug affected disk, wait 30 seconds, reinsert it. 2) Check/replace cable between controller and affected disk. 3) Check version of RAID controller/iRMC firmware, and BIOS. 4) Replace affected disk." --#STATE OPERATIONAL ::= 10864 -- EVT_PD_SAS_WIDE_PORT_LINK_RESTORED svrTrapPDSASWidePortLinkRestored TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk link restored in SAS wide port." --#TYPE "Disk link restored in SAS wide port" --#SUMMARY "Adapter %s: Disk (%s) link %s restored in SAS wide port (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10865 -- EVT_TMM_FRU svrTrapTMMFRU TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Memory module FRU." --#TYPE "Memory module FRU" --#SUMMARY "Adapter %s: Memory module FRU is %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10866 -- EVT_BBU_REPLACEMENT_NEEDED svrTrapBBUReplacementNeeded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "FBU power pack is sub-optimal." --#TYPE "FBU power pack is sub-optimal" --#SUMMARY "Adapter %s: FBU power pack is sub-optimal (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Replace FBU." --#STATE OPERATIONAL ::= 10867 -- EVT_FOREIGN_CFG_AUTO_IMPORT_NONE svrTrapForeignConfigAutoImportNone TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Foreign configuration auto-import did not import any drives." --#TYPE "Foreign configuration auto-import did not import any drives" --#SUMMARY "Adapter %s: Foreign configuration auto-import did not import any drives (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Attempt to import a foreign config failed. 1) Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10868 -- EVT_BBU_MICROCODE_UPDATE_REQUIRED svrTrapBBUMicrocodeUpdateRequired TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "FBU firmware update required." --#TYPE "FBU firmware update required" --#SUMMARY "Adapter %s: FBU firmware update required (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10869 -- EVT_LD_SSC_SIZE_EXCEEDED svrTrapLDSSCSizeExceeded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "CacheCade capacity exceeds maximum allowed size." --#TYPE "CacheCade capacity exceeds maximum allowed size" --#SUMMARY "Adapter %s: CacheCade %s capacity exceeds maximum allowed size of %s MB, extra capacity is not used (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10870 -- EVT_LD_PI_LOST svrTrapLDPILost TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive protection information lost." --#TYPE "Logical drive protection information lost" --#SUMMARY "Adapter %s: Logical drive %s protection information lost (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10871 -- EVT_PD_SHIELD_DIAG_PASS svrTrapPDShieldDiagPass TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Diagnostics passed for disk." --#TYPE "Diagnostics passed for disk" --#SUMMARY "Adapter %s: Diagnostics passed for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10872 -- EVT_PD_SHIELD_DIAG_FAIL svrTrapPDShieldDiagFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Diagnostics failed for disk." --#TYPE "Diagnostics failed for disk" --#SUMMARY "Adapter %s: Diagnostics failed for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE OPERATIONAL ::= 10873 -- EVT_CTRL_SERVER_POWER_DIAG_STARTED svrTrapCtrlServerPowerDiagStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Server power capability diagnostic test started." --#TYPE "Server power capability diagnostic test started" --#SUMMARY "Adapter %s: Server power capability diagnostic test started (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10874 -- EVT_PD_RBLD_DRIVE_CACHE_ENABLED svrTrapPDRbldDriveCacheEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk cache settings enabled during rebuild for disk." --#TYPE "Disk cache settings enabled during rebuild for disk" --#SUMMARY "Adapter %s: Disk cache settings enabled during rebuild for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10875 -- EVT_PD_RBLD_DRIVE_CACHE_RESTORED svrTrapPDRbldDriveCacheRestored TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk cache settings restored after rebuild for disk." --#TYPE "Disk cache settings restored after rebuild for disk" --#SUMMARY "Adapter %s: Disk cache settings restored after rebuild for disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10876 -- EVT_PD_EMERGENCY_SPARE_COMMISSIONED svrTrapPDEmergencySpareCommissioned TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk commissioned as emergency spare." --#TYPE "Disk commissioned as emergency spare" --#SUMMARY "Adapter %s: Disk (%s) commissioned as emergency spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10877 -- EVT_PD_EMERGENCY_SPARE_COMMISSIONED_REMINDER svrTrapPDEmergencySpareCommissionedReminder TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reminder: Potential non-optimal configuration because disk is commissioned as emergency spare." --#TYPE "Reminder: Potential non-optimal configuration because disk is commissioned as emergency spare" --#SUMMARY "Adapter %s: Reminder: Potential non-optimal configuration because disk (%s) is commissioned as emergency spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10878 -- EVT_LD_BGI_SUSPENDED svrTrapLDBGISuspended TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI suspended on logical drive." --#TYPE "BGI suspended on logical drive" --#SUMMARY "Adapter %s: BGI suspended on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10879 -- EVT_LD_BGI_RESUMED svrTrapLDBGIResumed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BGI resumed on logical drive." --#TYPE "BGI resumed on logical drive" --#SUMMARY "Adapter %s: BGI resumed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10880 -- EVT_LD_RECON_SUSPENDED svrTrapLDReconSuspended TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Migration suspended on logical drive." --#TYPE "Migration suspended on logical drive" --#SUMMARY "Adapter %s: Migration suspended on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10881 -- EVT_PD_COPYBACK_SUSPENDED svrTrapPDCopybackSuspended TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Copyback suspended on disk." --#TYPE "Copyback suspended on disk" --#SUMMARY "Adapter %s: Copyback suspended on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10882 -- EVT_LD_CC_SUSPENDED_REMINDER svrTrapLDCCSuspendedReminder TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reminder: MDC suspended on logical drive." --#TYPE "Reminder: MDC suspended on logical drive" --#SUMMARY "Adapter %s: Reminder: MDC suspended on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10883 -- EVT_LD_BGI_SUSPENDED_REMINDER svrTrapLDBGISuspendedReminder TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reminder: BGI suspended on logical drive." --#TYPE "Reminder: BGI suspended on logical drive" --#SUMMARY "Adapter %s: Reminder: BGI suspended on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10884 -- EVT_LD_RECON_SUSPENDED_REMINDER svrTrapLDReconSuspendedReminder TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reminder: Migration suspended on logical drive." --#TYPE "Reminder: Migration suspended on logical drive" --#SUMMARY "Adapter %s: Reminder: Migration suspended on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10885 -- EVT_PD_RBLD_SUSPENDED_REMINDER svrTrapPDRbldSuspendedReminder TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reminder: Rebuild suspended on disk." --#TYPE "Reminder: Rebuild suspended on disk" --#SUMMARY "Adapter %s: Reminder: Rebuild suspended on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10886 -- EVT_PD_COPYBACK_SUSPENDED_REMINDER svrTrapPDCopybackSuspendedReminder TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reminder: Copyback suspended on disk." --#TYPE "Reminder: Copyback suspended on disk" --#SUMMARY "Adapter %s: Reminder: Copyback suspended on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10887 -- EVT_CTRL_PR_SUSPENDED_REMINDER svrTrapCtrlPRSuspendedReminder TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reminder: Patrol Read suspended." --#TYPE "Reminder: Patrol Read suspended" --#SUMMARY "Adapter %s: Reminder: Patrol Read suspended (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10888 -- EVT_PD_ERASE_ABORTED svrTrapPDEraseAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase aborted on disk." --#TYPE "Erase aborted on disk" --#SUMMARY "Adapter %s: Erase aborted on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10889 -- EVT_PD_ERASE_FAILED svrTrapPDEraseFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase failed on disk." --#TYPE "Erase failed on disk" --#SUMMARY "Adapter %s: Erase failed on disk (%s) (error %s) (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10890 -- EVT_PD_ERASE_PROGRESS svrTrapPDEraseProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase progress on disk." --#TYPE "Erase progress on disk" --#SUMMARY "Adapter %s: Erase progress on disk (%s) is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10891 -- EVT_PD_ERASE_STARTED svrTrapPDEraseStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase started on disk." --#TYPE "Erase started on disk" --#SUMMARY "Adapter %s: Erase started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10892 -- EVT_PD_ERASE_SUCCESSFUL svrTrapPDEraseSuccessful TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase finished on disk." --#TYPE "Erase finished on disk" --#SUMMARY "Adapter %s: Erase finished on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10893 -- EVT_LD_ERASE_ABORTED svrTrapLDEraseAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase aborted on logical drive." --#TYPE "Erase aborted on logical drive" --#SUMMARY "Adapter %s: Erase aborted on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10894 -- EVT_LD_ERASE_FAILED svrTrapLDEraseFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase failed on logical drive." --#TYPE "Erase failed on logical drive" --#SUMMARY "Adapter %s: Erase failed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "1) Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10895 -- EVT_LD_ERASE_PROGRESS svrTrapLDEraseProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase progress on logical drive." --#TYPE "Erase progress on logical drive" --#SUMMARY "Adapter %s: Erase progress on logical drive %s is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10896 -- EVT_LD_ERASE_START svrTrapLDEraseStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase started on logical drive." --#TYPE "Erase started on logical drive" --#SUMMARY "Adapter %s: Erase started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10897 -- EVT_LD_ERASE_SUCCESSFUL svrTrapLDEraseSuccessful TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Erase finished on logical drive." --#TYPE "Erase finished on logical drive" --#SUMMARY "Adapter %s: Erase finished on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10898 -- EVT_LD_ERASE_POTENTIAL_LEAKAGE svrTrapLDErasePotentialLeakage TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Potential leakage during erase on logical drive." --#TYPE "Potential leakage during erase on logical drive" --#SUMMARY "Adapter %s: Potential leakage during erase on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10899 -- EVT_BBU_CHARGE_DISABLED_OTC svrTrapBBUChargeDisabledOTC TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU charging was suspended due to high BBU temperature." --#TYPE "BBU charging was suspended due to high BBU temperature" --#SUMMARY "Adapter %s: BBU charging was suspended due to high BBU temperature (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Bring system back to normal operating temperature." --#STATE OPERATIONAL ::= 10900 -- EVT_BBU_MICROCODE_UPDATED svrTrapBBUMicrocodeUpdated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "FBU firmware update finished." --#TYPE "FBU firmware update finished" --#SUMMARY "Adapter %s: FBU firmware update finished (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10901 -- EVT_BBU_MICROCODE_UPDATE_FAILED svrTrapBBUMicrocodeUpdateFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "FBU firmware update failed." --#TYPE "FBU firmware update failed" --#SUMMARY "Adapter %s: FBU firmware update failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10902 -- EVT_LD_ACCESS_BLOCKED_SSC_OFFLINE svrTrapLDAccessBlockedSSCOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive access blocked as cached data in CacheCade is unavailable." --#TYPE "Logical drive access blocked as cached data in CacheCade is unavailable" --#SUMMARY "Adapter %s: Logical drive %s access blocked as cached data in CacheCade is unavailable (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 10903 -- EVT_LD_SSC_DISASSOCIATE_START svrTrapLDSSCDisassociateStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "CacheCade disassociate started on logical drive." --#TYPE "CacheCade disassociate started on logical drive" --#SUMMARY "Adapter %s: CacheCade disassociate started on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10904 -- EVT_LD_SSC_DISASSOCIATE_DONE svrTrapLDSSCDisassociateDone TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "CacheCade disassociate finished on logical drive." --#TYPE "CacheCade disassociate finished on logical drive" --#SUMMARY "Adapter %s: CacheCade disassociate finished on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10905 -- EVT_LD_SSC_DISASSOCIATE_FAILED svrTrapLDSSCDisassociateFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "CacheCade disassociate failed on logical drive." --#TYPE "CacheCade disassociate failed on logical drive" --#SUMMARY "Adapter %s: CacheCade disassociate failed on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10906 -- EVT_LD_SSC_DISASSOCIATE_PROGRESS svrTrapLDSSCDisassociateProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "CacheCade disassociate progress on logical drive." --#TYPE "CacheCade disassociate progress on logical drive" --#SUMMARY "Adapter %s: CacheCade disassociate progress on logical drive %s is %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10907 -- EVT_LD_SSC_DISASSOCIATE_ABORT_BY_USER svrTrapLDSSCDisassociateAbortByUser TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "CacheCade disassociate aborted by user on logical drive." --#TYPE "CacheCade disassociate aborted by user on logical drive" --#SUMMARY "Adapter %s: CacheCade disassociate aborted by user on logical drive %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10908 -- EVT_PD_SENSE_WARNING svrTrapPDSenseWarning TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unexpected sense." --#TYPE "Unexpected sense" --#SUMMARY "Adapter %s: Unexpected sense: Disk (%s), Key/ASC/ASCQ: %s: %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10909 -- EVT_PD_SENSE_ERROR svrTrapPDSenseError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unexpected sense." --#TYPE "Unexpected sense" --#SUMMARY "Adapter %s: Unexpected sense: Disk (%s), Key/ASC/ASCQ: %s: %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10910 -- EVT_PD_REBUILD_PAUSED svrTrapPDRebuildPaused TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild suspended on disk." --#TYPE "Rebuild suspended on disk" --#SUMMARY "Adapter %s: Rebuild suspended on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE DEGRADED ::= 10911 -- EVT_PD_REBUILD_RESUMED svrTrapPDRebuildResumed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Rebuild resumed on disk." --#TYPE "Rebuild resumed on disk" --#SUMMARY "Adapter %s: Rebuild resumed on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10912 -- EVT_SAS_PHY_LINK_SPEED_UPDATED svrTrapSASPhyLinkSpeedUpdated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Link speed changed on SAS port and PHY." --#TYPE "Link speed changed on SAS port and PHY" --#SUMMARY "Adapter %s: Link speed changed on SAS port %s and PHY %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10913 -- EVT_CTRL_PFK_DEACTIVATED svrTrapCtrlPFKDeactivated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MegaRAID Advanced Software Options were deactivated for." --#TYPE "MegaRAID Advanced Software Options were deactivated for" --#SUMMARY "Adapter %s: MegaRAID Advanced Software Options were deactivated for - %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10914 -- EVT_LD_ACCESS_UNBLOCKED svrTrapLDAccessUnblocked TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is now accessible." --#TYPE "Logical drive is now accessible" --#SUMMARY "Adapter %s: Logical drive %s is now accessible (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10915 -- EVT_LD_IS_USING_SSC_2 svrTrapLDIsUsingSSC2 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is using CacheCade." --#TYPE "Logical drive is using CacheCade" --#SUMMARY "Adapter %s: Logical drive %s is using CacheCade (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10916 -- EVT_LD_IS_NOT_USING_SSC_2 svrTrapLDIsNotUsingSSC2 TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is no longer using CacheCade." --#TYPE "Logical drive is no longer using CacheCade" --#SUMMARY "Adapter %s: Logical drive %s is no longer using CacheCade (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10917 -- EVT_PD_PR_ABORTED svrTrapPDPRAborted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol Read aborted on disk." --#TYPE "Patrol Read aborted on disk" --#SUMMARY "Adapter %s: Patrol Read aborted on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: If there are errors directly before or after this event, perform the proper recovery action for that error. 1) For information only." --#STATE OPERATIONAL ::= 10918 -- EVT_PD_TRANSIENT_ERROR_DETECTED svrTrapPDTransientErrorDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Transient error detected while communicating with disk." --#TYPE "Transient error detected while communicating with disk" --#SUMMARY "Adapter %s: Transient error detected while communicating with disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Doesn't affect the normal operation of the system, but can lead to degraded performance due to retries. 1) Replace affected disk/backplane/cable at next service." --#STATE OPERATIONAL ::= 10919 -- EVT_PNPADD_EX svrTrapPNPADDEx TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Additional information for detected disk." --#TYPE "Additional information for detected disk" --#SUMMARY "Adapter %s: Additional information for detected disk (%s) - firmware version: %s, serial number %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10920 -- EVT_RAID_MANAGER_STARTED svrTrapRAIDManagerStarted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "RAID Manager started." --#TYPE "RAID Manager started" --#SUMMARY "RAID Manager started (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10921 -- EVT_RAID_MANAGER_STOPPED svrTrapRAIDManagerStopped TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "RAID Manager stopped." --#TYPE "RAID Manager stopped" --#SUMMARY "RAID Manager stopped (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10922 -- EVT_PD_STATE_CHANGE_SHIELD_TO_AVAIL svrTrapPDStateChangeShieldToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from shielded to available." --#TYPE "State change from shielded to available" --#SUMMARY "Adapter %s: State change on disk (%s) from shielded to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10923 -- EVT_PD_STATE_CHANGE_SHIELD_TO_OFFL svrTrapPDStateChangeShieldToOffl TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from shielded to offline." --#TYPE "State change from shielded to offline" --#SUMMARY "Adapter %s: State change on disk (%s) from shielded to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE DEGRADED ::= 10924 -- EVT_PD_STATE_CHANGE_SHIELD_TO_FAIL svrTrapPDStateChangedShieldToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from shielded to failed." --#TYPE "State change from shielded to failed" --#SUMMARY "Adapter %s: State change on disk (%s) from shielded to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10925 -- EVT_PD_STATE_CHANGE_SHIELD_TO_HS svrTrapPDStateChangeShieldToHs TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from shielded to hot spare." --#TYPE "State change from shielded to hot spare" --#SUMMARY "Adapter %s: State change on disk (%s) from shielded to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10926 -- EVT_PD_STATE_CHANGE_SHIELD_TO_RBLD svrTrapPDStateChangeShieldToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from shielded to rebuilding." --#TYPE "State change from shielded to rebuilding" --#SUMMARY "Adapter %s: State change on disk (%s) from shielded to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10927 -- EVT_PD_STATE_CHANGE_SHIELD_TO_OP svrTrapPDStateChangeShieldToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from shielded to operational." --#TYPE "State change from shielded to operational" --#SUMMARY "Adapter %s: State change on disk (%s) from shielded to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10928 -- EVT_PD_STATE_CHANGE_SHIELD_TO_CB svrTrapPDStateChangeShieldToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from shielded to copyback." --#TYPE "State change from shielded to copyback" --#SUMMARY "Adapter %s: State change on disk (%s) from shielded to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10929 -- EVT_PD_STATE_CHANGE_SHIELD_TO_SYS svrTrapPDStateChangeShieldToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from shielded to JBOD." --#TYPE "State change from shielded to JBOD" --#SUMMARY "Adapter %s: State change on disk (%s) from shielded to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10930 -- EVT_PD_STATE_CHANGE_SHIELD_TO_SHIELD svrTrapPDStateChangedShieldToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from shielded to shielded." --#TYPE "State change from shielded to shielded" --#SUMMARY "Adapter %s: State change on disk (%s) from shielded to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10931 -- EVT_PD_STATE_CHANGE_AVAIL_TO_SHIELD svrTrapPDStateChangedAvailToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from available to shielded." --#TYPE "State change from available to shielded" --#SUMMARY "Adapter %s: State change on disk (%s) from available to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10932 -- EVT_PD_STATE_CHANGE_OFFL_TO_SHIELD svrTrapPDStateChangedOfflToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from offline to shielded." --#TYPE "State change from offline to shielded" --#SUMMARY "Adapter %s: State change on disk (%s) from offline to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10933 -- EVT_PD_STATE_CHANGE_FAIL_TO_SHIELD svrTrapPDStateChangedFailToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from failed to shielded." --#TYPE "State change from failed to shielded" --#SUMMARY "Adapter %s: State change on disk (%s) from failed to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10934 -- EVT_PD_STATE_CHANGE_HS_TO_SHIELD svrTrapPDStateChangedHsToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from hot spare to shielded." --#TYPE "State change from hot spare to shielded" --#SUMMARY "Adapter %s: State change on disk (%s) from hot spare to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10935 -- EVT_PD_STATE_CHANGE_RBLD_TO_SHIELD svrTrapPDStateChangedRbldToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from rebuilding to shielded." --#TYPE "State change from rebuilding to shielded" --#SUMMARY "Adapter %s: State change on disk (%s) from rebuilding to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10936 -- EVT_PD_STATE_CHANGE_OP_TO_SHIELD svrTrapPDStateChangedOpToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from operational to shielded." --#TYPE "State change from operational to shielded" --#SUMMARY "Adapter %s: State change on disk (%s) from operational to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10937 -- EVT_PD_STATE_CHANGE_CB_TO_SHIELD svrTrapPDStateChangedCbToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from copyback to shielded." --#TYPE "State change from copyback to shielded" --#SUMMARY "Adapter %s: State change on disk (%s) from copyback to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10938 -- EVT_PD_STATE_CHANGE_SYS_TO_SHIELD svrTrapPDStateChangedSysToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change from JBOD to shielded." --#TYPE "State change from JBOD to shielded" --#SUMMARY "Adapter %s: State change on disk (%s) from JBOD to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10939 -- EVT_PD_STATE_CHANGE_BY_USER_SHIELD_TO_AVAIL svrTrapPDStateChangeByUserShieldToAvail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from shielded to available." --#TYPE "State change by user from shielded to available" --#SUMMARY "Adapter %s: State change by user on disk (%s) from shielded to available (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10940 -- EVT_PD_STATE_CHANGE_BY_USER_SHIELD_TO_OFFL svrTrapPDStateChangeByUserShieldToOffl TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from shielded to offline." --#TYPE "State change by user from shielded to offline" --#SUMMARY "Adapter %s: State change by user on disk (%s) from shielded to offline (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE DEGRADED ::= 10941 -- EVT_PD_STATE_CHANGE_BY_USER_SHIELD_TO_FAIL svrTrapPDStateChangeByUserShieldToFail TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from shielded to failed." --#TYPE "State change by user from shielded to failed" --#SUMMARY "Adapter %s: State change by user on disk (%s) from shielded to failed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10942 -- EVT_PD_STATE_CHANGE_BY_USER_SHIELD_TO_HS svrTrapPDStateChangeByUserShieldToHs TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from shielded to hot spare." --#TYPE "State change by user from shielded to hot spare" --#SUMMARY "Adapter %s: State change by user on disk (%s) from shielded to hot spare (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10943 -- EVT_PD_STATE_CHANGE_BY_USER_SHIELD_TO_RBLD svrTrapPDStateChangeByUserShieldToRbld TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from shielded to rebuilding." --#TYPE "State change by user from shielded to rebuilding" --#SUMMARY "Adapter %s: State change by user on disk (%s) from shielded to rebuilding (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10944 -- EVT_PD_STATE_CHANGE_BY_USER_SHIELD_TO_OP svrTrapPDStateChangeByUserShieldToOp TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from shielded to operational." --#TYPE "State change by user from shielded to operational" --#SUMMARY "Adapter %s: State change by user on disk (%s) from shielded to operational (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10945 -- EVT_PD_STATE_CHANGE_BY_USER_SHIELD_TO_CB svrTrapPDStateChangeByUserShieldToCb TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from shielded to copyback." --#TYPE "State change by user from shielded to copyback" --#SUMMARY "Adapter %s: State change by user on disk (%s) from shielded to copyback (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10946 -- EVT_PD_STATE_CHANGE_BY_USER_SHIELD_TO_SYS svrTrapPDStateChangeByUserShieldToSys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from shielded to JBOD." --#TYPE "State change by user from shielded to JBOD" --#SUMMARY "Adapter %s: State change by user on disk (%s) from shielded to JBOD (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10947 -- EVT_PD_STATE_CHANGE_BY_USER_SHIELD_TO_SHIELD svrTrapPDStateChangeByUserShieldToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from shielded to shielded." --#TYPE "State change by user from shielded to shielded" --#SUMMARY "Adapter %s: State change by user on disk (%s) from shielded to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Replace affected disk." --#STATE NONOPERATIONAL ::= 10948 -- EVT_PD_STATE_CHANGE_BY_USER_AVAIL_TO_SHIELD svrTrapPDStateChangeByUserAvailToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from available to shielded." --#TYPE "State change by user from available to shielded" --#SUMMARY "Adapter %s: State change by user on disk (%s) from available to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10949 -- EVT_PD_STATE_CHANGE_BY_USER_OFFL_TO_SHIELD svrTrapPDStateChangeByUserOfflToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from offline to shielded." --#TYPE "State change by user from offline to shielded" --#SUMMARY "Adapter %s: State change by user on disk (%s) from offline to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10950 -- EVT_PD_STATE_CHANGE_BY_USER_FAIL_TO_SHIELD svrTrapPDStateChangeByUserFailToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from failed to shielded." --#TYPE "State change by user from failed to shielded" --#SUMMARY "Adapter %s: State change by user on disk (%s) from failed to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10951 -- EVT_PD_STATE_CHANGE_BY_USER_HS_TO_SHIELD svrTrapPDStateChangeByUserHsToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from hot spare to shielded." --#TYPE "State change by user from hot spare to shielded" --#SUMMARY "Adapter %s: State change by user on disk (%s) from hot spare to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10952 -- EVT_PD_STATE_CHANGE_BY_USER_RBLD_TO_SHIELD svrTrapPDStateChangeByUserRbldToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from rebuilding to shielded." --#TYPE "State change by user from rebuilding to shielded" --#SUMMARY "Adapter %s: State change by user on disk (%s) from rebuilding to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10953 -- EVT_PD_STATE_CHANGE_BY_USER_OP_TO_SHIELD svrTrapPDStateChangeByUserOpToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from operational to shielded." --#TYPE "State change by user from operational to shielded" --#SUMMARY "Adapter %s: State change by user on disk (%s) from operational to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10954 -- EVT_PD_STATE_CHANGE_BY_USER_CB_TO_SHIELD svrTrapPDStateChangeByUserCbToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from copyback to shielded." --#TYPE "State change by user from copyback to shielded" --#SUMMARY "Adapter %s: State change by user on disk (%s) from copyback to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10955 -- EVT_PD_STATE_CHANGE_BY_USER_SYS_TO_SHIELD svrTrapPDStateChangeByUserSysToShield TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "State change by user from JBOD to shielded." --#TYPE "State change by user from JBOD to shielded" --#SUMMARY "Adapter %s: State change by user on disk (%s) from JBOD to shielded (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Wait until checking in shielded state is completed. 2) Perform action according to upcoming status." --#STATE NONOPERATIONAL ::= 10956 -- EVT_CTRL_INTERNAL_ERROR svrTrapCtrlInternalError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal error." --#TYPE "Internal error" --#SUMMARY "Adapter %s: Internal error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "If problem persists after reboot, call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 10957 -- EVT_CTRL_INCOMPATIBLE_PCI_BANDWIDTH svrTrapCtrlIncompatiblePCIBandwidth TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Incompatible PCI slot bandwidth." --#TYPE "Incompatible PCI slot bandwidth" --#SUMMARY "Adapter %s: Incompatible PCI slot bandwidth (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Reinstall adapter in a compatible PCI slot." --#STATE NONOPERATIONAL ::= 10958 -- EVT_CTRL_PARTIAL_WRITE_THROTTLING svrTrapCtrlPartialWriteThrottling TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write performance reduced." --#TYPE "Write performance reduced" --#SUMMARY "Adapter %s: Write performance reduced (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check additional status property for more information." --#STATE OPERATIONAL ::= 10959 -- EVT_CTRL_MAXIMUM_WRITE_THROTTLING svrTrapCtrlMaximumWriteThrottling TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write operations maximally reduced." --#TYPE "Write operations maximally reduced" --#SUMMARY "Adapter %s: Write operations maximally reduced (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Check additional status property for more information." --#STATE OPERATIONAL ::= 10960 -- EVT_CTRL_TEMPERATURE_NEAR_ERROR svrTrapCtrlTemperatureNearError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Temperature close to error threshold." --#TYPE "Temperature close to error threshold" --#SUMMARY "Adapter %s: Temperature close to error threshold (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Increase cooling or reduce write load." --#STATE OPERATIONAL ::= 10961 -- EVT_CTRL_TEMPERATURE_ABOVE_ERROR svrTrapCtrlTemperatureAboveError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Temperature above error threshold." --#TYPE "Temperature above error threshold" --#SUMMARY "Adapter %s: Temperature above error threshold (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Increase cooling or reduce write load." --#STATE NONOPERATIONAL ::= 10962 -- EVT_CTRL_INTERNAL_VOLTAGE_OUT_OF_RANGE svrTrapCtrlInternalVoltageOutOfRange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Internal voltage out of range." --#TYPE "Internal voltage out of range" --#SUMMARY "Adapter %s: Internal voltage out of range (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "If problem persists after reboot, call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 10963 -- EVT_CTRL_AUXILIARY_VOLTAGE_OUT_OF_RANGE svrTrapCtrlAuxiliaryVoltageOutOfRange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Auxiliary voltage out of range." --#TYPE "Auxiliary voltage out of range" --#SUMMARY "Adapter %s: Auxiliary voltage out of range (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "If problem persists after reboot, call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 10964 -- EVT_CTRL_FLASHBACK svrTrapCtrlFlashback TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flashback error." --#TYPE "Flashback error" --#SUMMARY "Adapter %s: Flashback error (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "1) Backup data from affected adapter. 2) Replace adapter as soon as possible. 3) Restore data." --#STATE NONOPERATIONAL ::= 10965 -- EVT_CTRL_NONCORRECTABLE_PCI_ERRORS svrTrapCtrlNonCorrectablePCIErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Non-correctable PCI errors detected." --#TYPE "Non-correctable PCI errors detected" --#SUMMARY "Adapter %s: Non-correctable PCI errors detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "If problem persists after reboot, call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 10966 -- EVT_CTRL_TEMPERATURE_ABOVE_WARN svrTrapCtrlTemperatureAboveWarn TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Temperature above warning threshold." --#TYPE "Temperature above warning threshold" --#SUMMARY "Adapter %s: Temperature above warning threshold (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Increase cooling or reduce write load." --#STATE OPERATIONAL ::= 10967 -- EVT_CTRL_NEAR_WEARING_OUT svrTrapCtrlNearWearingOut TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Memory is close to wearing out." --#TYPE "Memory is close to wearing out" --#SUMMARY "Adapter %s: Memory is close to wearing out (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Formatting to a smaller size will free up reserve." --#STATE OPERATIONAL ::= 10968 -- EVT_CTRL_NONOPTIMAL_PCI_BANDWIDTH svrTrapCtrlNonOptimalPCISlotBandwidth TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Non-optimal PCI slot bandwidth." --#TYPE "Non-optimal PCI slot bandwidth" --#SUMMARY "Adapter %s: Non-optimal PCI slot bandwidth (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Reinstall adapter in an optimal PCI slot." --#STATE OPERATIONAL ::= 10969 -- EVT_CTRL_CORRECTABLE_PCI_ERRORS svrTrapCtrlCorrectablePCIErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Correctable PCI errors detected." --#TYPE "Correctable PCI errors detected" --#SUMMARY "Adapter %s: Correctable PCI errors detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 10970 -- EVT_CTRL_NO_POWERLOSS_PROTECTION svrTrapCtrlNoPowerlossProtection TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power loss protection disabled." --#TYPE "Power loss protection disabled" --#SUMMARY "Adapter %s: Power loss protection disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Activate power loss protection." --#STATE OPERATIONAL ::= 10971 -- EVT_CTRL_POWER_WRITE_REGULATION svrTrapCtrlPowerWriteRegulation TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write regulation activated due to power constraints of PCI slot." --#TYPE "Write regulation activated due to power constraints of PCI slot" --#SUMMARY "Adapter %s: Write regulation activated due to power constraints of PCI slot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "If this condition persists, switch to a higher powered PCI slot or attach external power cable." --#STATE OPERATIONAL ::= 10972 -- EVT_CTRL_TEMPERATURE_WRITE_REGULATION svrTrapCtrlTemperatureWriteRegulation TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write regulation activated due to high temperature." --#TYPE "Write regulation activated due to high temperature" --#SUMMARY "Adapter %s: Write regulation activated due to high temperature (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "If this condition persists, increase air flow, lower room temperature or reduce write load." --#STATE OPERATIONAL ::= 10973 -- EVT_CTRL_LIFESPAN_WRITE_REGULATION svrTrapCtrlLifespanWriteRegulation TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write regulation activated to ensure adapter lifespan." --#TYPE "Write regulation activated to ensure adapter lifespan" --#SUMMARY "Adapter %s: Write regulation activated to ensure adapter lifespan (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "If this condition persists, reduce write load." --#STATE OPERATIONAL ::= 10974 -- EVT_CTRL_MINIMAL svrTrapCtrlMinimal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Running in minimal status." --#TYPE "Running in minimal status" --#SUMMARY "Adapter %s: Running in minimal status (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Check additional status property for more information." --#STATE OPERATIONAL ::= 10975 -- EVT_CTRL_PCI_OVERPOWER svrTrapCtrlPCIOverpower TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "PCI power budget alarm." --#TYPE "PCI power budget alarm" --#SUMMARY "Adapter %s: PCI power budget alarm (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Switch to a higher powered PCI slot or attach external power cable." --#STATE OPERATIONAL ::= 10976 -- EVT_CTRL_LEB_MAP_MISSING svrTrapCtrlLEBMapMissing TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "LEB map missing." --#TYPE "LEB map missing" --#SUMMARY "Adapter %s: LEB map missing (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "If problem persists after reboot, call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10977 -- EVT_CTRL_UPDATE_IN_PROGRESS svrTrapCtrlUpdateInProgress TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Update in progress." --#TYPE "Update in progress" --#SUMMARY "Adapter %s: Update in progress (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "The adapter will not be usable until formatting is complete." --#STATE OPERATIONAL ::= 10978 -- EVT_CTRL_RESERVES_DEPLETED svrTrapCtrlReservesDepleted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reserves depleted." --#TYPE "Reserves depleted" --#SUMMARY "Adapter %s: Reserves depleted (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Formatting to a smaller size will free up reserve." --#STATE OPERATIONAL ::= 10979 -- EVT_CTRL_NORMAL svrTrapCtrlNormal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter normal." --#TYPE "Adapter normal" --#SUMMARY "Adapter %s: Adapter normal (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10980 -- EVT_CTRL_ATTACH_FAILED svrTrapCtrlAttachFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Attach failed." --#TYPE "Attach failed" --#SUMMARY "Adapter %s: Attach failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "If problem persists, call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 10981 -- EVT_CTRL_DETACH_FAILED svrTrapCtrlDetachFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Detach failed." --#TYPE "Detach failed" --#SUMMARY "Adapter %s: Detach failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Force detach. 2) If problem persists, call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10982 -- EVT_CTRL_ATTACHED svrTrapCtrlAttached TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Attached." --#TYPE "Attached" --#SUMMARY "Adapter %s: Attached (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10983 -- EVT_CTRL_DETACHED svrTrapCtrlDetached TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Detached." --#TYPE "Detached" --#SUMMARY "Adapter %s: Detached (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "For information only." --#STATE NONOPERATIONAL ::= 10984 -- EVT_PD_FORMAT_CHANGED svrTrapPDFormatChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Format of disk changed." --#TYPE "Format of disk changed" --#SUMMARY "Adapter %s: Format of disk (%s) changed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10985 -- EVT_LOG_CLEARED svrTrapFileLogCleared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "File log cleared." --#TYPE "File log cleared" --#SUMMARY "File log cleared (Server %s)" --#ARGUMENTS { 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10986 -- EVT_PD_OFFLINE_SMART svrTrapPDOfflineSmart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk will be set offline due to SMART error." --#TYPE "Disk will be set offline due to SMART error" --#SUMMARY "Adapter %s: Disk (%s) will be set offline due to SMART error (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10987 -- EVT_PD_OFFLINE_SENSE_KEYS svrTrapPDOfflineSenseKeys TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk will be set offline due to too many unexpected sense events." --#TYPE "Disk will be set offline due to too many unexpected sense events" --#SUMMARY "Adapter %s: Disk (%s) will be set offline due to too many unexpected sense events (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10988 -- EVT_LD_PI_ERR_IN_CACHE svrTrapLDPIErrInCache TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Protection information error in cache for logical drive." --#TYPE "Protection information error in cache for logical drive" --#SUMMARY "Adapter %s: Protection information error in cache for logical drive %s at LBA %s (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10989 -- EVT_CTRL_FLASH_IMAGE_UNSUPPORTED svrTrapCtrlFlashImageUnsupported TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Flash downloaded image is not supported." --#TYPE "Flash downloaded image is not supported" --#SUMMARY "Adapter %s: Flash downloaded image is not supported (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10990 -- EVT_BBU_MODE_SET svrTrapBBUModeSet TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU mode selected." --#TYPE "BBU mode selected" --#SUMMARY "Adapter %s: BBU mode selected - %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10991 -- EVT_BBU_PERIODIC_RELEARN_RESCHEDULED svrTrapBBUPeriodicRelearnRescheduled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Periodic BBU relearn was missed and rescheduled." --#TYPE "Periodic BBU relearn was missed and rescheduled" --#SUMMARY "Adapter %s: Periodic BBU relearn was missed, and rescheduled to %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10992 -- EVT_CTRL_RESETNOW_START svrTrapCtrlResetnowStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter reset requested by host." --#TYPE "Adapter reset requested by host" --#SUMMARY "Adapter %s: Adapter reset requested by host (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10993 -- EVT_CTRL_RESETNOW_DONE svrTrapCtrlResetnowDone TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter reset requested by host completed." --#TYPE "Adapter reset requested by host completed" --#SUMMARY "Adapter %s: Adapter reset requested by host, completed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 10994 -- EVT_L3_CACHE_ERROR svrTrapL3CacheError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "L3 cache error has been detected." --#TYPE "L3 cache error has been detected" --#SUMMARY "Adapter %s: L3 cache error has been detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10995 -- EVT_L2_CACHE_ERROR svrTrapL2CacheError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "L2 cache error has been detected." --#TYPE "L2 cache error has been detected" --#SUMMARY "Adapter %s: L2 cache error has been detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10996 -- EVT_CTRL_BOOT_HEADLESS_MODE_HAD_ERRORS svrTrapCtrlBootHeadlessModeHadErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter booted in headless mode with errors." --#TYPE "Adapter booted in headless mode with errors" --#SUMMARY "Adapter %s: Adapter booted in headless mode with errors (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10997 -- EVT_CTRL_BOOT_SAFE_MODE_FOR_ERRORS svrTrapCtrlBootSafeModeForErrors TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter booted to safe mode due to critical errors." --#TYPE "Adapter booted to safe mode due to critical errors" --#SUMMARY "Adapter %s: Adapter booted to safe mode due to critical errors (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10998 -- EVT_CTRL_BOOT_ERROR_WARNING svrTrapCtrlBootErrorWarning TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Warning during boot." --#TYPE "Warning during boot" --#SUMMARY "Adapter %s: Warning during boot - %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 10999 -- EVT_CTRL_BOOT_ERROR_CRITICAL svrTrapCtrlBootErrorCritical TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Critical error during boot." --#TYPE "Critical error during boot" --#SUMMARY "Adapter %s: Critical error during boot - %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11000 -- EVT_CTRL_BOOT_ERROR_FATAL svrTrapCtrlBootErrorFatal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Fatal error during boot." --#TYPE "Fatal error during boot" --#SUMMARY "Adapter %s: Fatal error during boot - %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 11001 -- EVT_HA_NODE_JOIN svrTrapHANodeJoin TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Peer adapter has joined high availability domain." --#TYPE "Peer adapter has joined high availability domain" --#SUMMARY "Adapter %s: Peer adapter has joined high availability domain (ID: %s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11002 -- EVT_HA_NODE_BREAK svrTrapHANodeBreak TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Peer adapter has left high availability domain." --#TYPE "Peer adapter has left high availability domain" --#SUMMARY "Adapter %s: Peer adapter has left high availability domain (ID: %s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11003 -- EVT_HA_PD_IS_REMOTE svrTrapHAPDIsRemote TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk is managed by peer adapter." --#TYPE "Disk is managed by peer adapter" --#SUMMARY "Adapter %s: Disk (%s) is managed by peer adapter (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11004 -- EVT_HA_PD_IS_LOCAL svrTrapHAPDIsLocal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk is managed by local adapter." --#TYPE "Disk is managed by local adapter" --#SUMMARY "Adapter %s: Disk (%s) is managed by local adapter (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11005 -- EVT_HA_LD_IS_REMOTE svrTrapHALDIsRemote TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is managed by peer adapter." --#TYPE "Logical drive is managed by peer adapter" --#SUMMARY "Adapter %s: Logical drive %s is managed by peer adapter (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11006 -- EVT_HA_LD_IS_LOCAL svrTrapHALDIsLocal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is managed by local adapter." --#TYPE "Logical drive is managed by local adapter" --#SUMMARY "Adapter %s: Logical drive %s is managed by local adapter (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11007 -- EVT_HA_LD_TARGET_ID_CONFLICT svrTrapHALDTargetIDConflict TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive has a conflict in high availability domain." --#TYPE "Logical drive has a conflict in high availability domain" --#SUMMARY "Adapter %s: Logical drive %s has a conflict in high availability domain (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11008 -- EVT_HA_LD_ACCESS_IS_SHARED svrTrapHALDAccessIsShared TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive access is shared." --#TYPE "Logical drive access is shared" --#SUMMARY "Adapter %s: Logical drive %s access is shared (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11009 -- EVT_HA_LD_ACCESS_IS_EXCLUSIVE svrTrapHALDAccessIsExclusive TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive access is exclusive." --#TYPE "Logical drive access is exclusive" --#SUMMARY "Adapter %s: Logical drive %s access is exclusive (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11010 -- EVT_HA_LD_INCOMPATIBLE svrTrapHALDIncompatible TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is incompatible in the high availability domain." --#TYPE "Logical drive is incompatible in the high availability domain" --#SUMMARY "Adapter %s: Logical drive %s is incompatible in the high availability domain (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11011 -- EVT_HA_PEER_INCOMPATIBLE svrTrapHAPeerIncompatible TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Peer adapter is incompatible." --#TYPE "Peer adapter is incompatible" --#SUMMARY "Adapter %s: Peer adapter is incompatible (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11012 -- EVT_HA_HW_INCOMPATIBLE svrTrapHAHWIncompatible TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapters in the high availability domain are incompatible." --#TYPE "Adapters in the high availability domain are incompatible" --#SUMMARY "Adapter %s: Adapters in the high availability domain are incompatible (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11013 -- EVT_HA_CTRLPROP_INCOMPATIBLE svrTrapHACtrlpropIncompatible TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter properties are incompatible between local and peer adapters." --#TYPE "Adapter properties are incompatible between local and peer adapters" --#SUMMARY "Adapter %s: Adapter properties are incompatible between local and peer adapters (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11014 -- EVT_HA_FW_VERSION_MISMATCH svrTrapHAFWVersionMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware versions do not match in the high availability domain." --#TYPE "Firmware versions do not match in the high availability domain" --#SUMMARY "Adapter %s: Firmware versions do not match in the high availability domain (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11015 -- EVT_HA_FEATURES_MISMATCH svrTrapHAFeaturesMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "MegaRAID Advanced Software Options do not match in the high availability domain." --#TYPE "MegaRAID Advanced Software Options do not match in the high availability domain" --#SUMMARY "Adapter %s: MegaRAID Advanced Software Options %s do not match in the high availability domain (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11016 -- EVT_HA_CACHE_MIRROR_ONLINE svrTrapHACacheMirrorOnline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "High availability cache mirror is online." --#TYPE "High availability cache mirror is online" --#SUMMARY "Adapter %s: High availability cache mirror is online (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11017 -- EVT_HA_CACHE_MIRROR_OFFLINE svrTrapHACacheMirrorOffline TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "High availability cache mirror is offline." --#TYPE "High availability cache mirror is offline" --#SUMMARY "Adapter %s: High availability cache mirror is offline (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11018 -- EVT_LD_ACCESS_BLOCKED_PEER_UNAVAILABLE svrTrapLDAccessBlockedPeerUnavailable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive access blocked as cached data from peer adapter is unavailable." --#TYPE "Logical drive access blocked as cached data from peer adapter is unavailable" --#SUMMARY "Adapter %s: Logical drive %s access blocked as cached data from peer adapter is unavailable (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 11019 -- EVT_BBU_UNSUPPORTED svrTrapBBUUnsupported TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "FBU power pack is not supported." --#TYPE "FBU power pack is not supported" --#SUMMARY "Adapter %s: FBU power pack is not supported. Please replace the pack (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11020 -- EVT_PD_TEMP_HIGH svrTrapPDTempHigh TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk temperature is above warning threshold." --#TYPE "Disk temperature is above warning threshold" --#SUMMARY "Adapter %s: Disk (%s) temperature (%s C) is above warning threshold (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11021 -- EVT_PD_TEMP_CRITICAL svrTrapPDTempCritical TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk temperature is above critical threshold." --#TYPE "Disk temperature is above critical threshold" --#SUMMARY "Adapter %s: Disk (%s) temperature (%s C) is above critical threshold (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11022 -- EVT_PD_TEMP_NORMAL svrTrapPDTempNormal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk temperature is normal." --#TYPE "Disk temperature is normal" --#SUMMARY "Adapter %s: Disk (%s) temperature (%s C) is normal (Server %s)" --#ARGUMENTS { 2, 3, 4, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11023 -- EVT_PD_IO_THROTTLED svrTrapPDIOThrottled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk IOs are being throttled." --#TYPE "Disk IOs are being throttled" --#SUMMARY "Adapter %s: Disk (%s) IOs are being throttled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11024 -- EVT_PD_IO_NOT_THROTTLED svrTrapPDIONotThrottled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk IOs are normal (no throttling)." --#TYPE "Disk IOs are normal (no throttling)" --#SUMMARY "Adapter %s: Disk (%s) IOs are normal (no throttling) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11025 -- EVT_PD_LIFE svrTrapPDLife TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk has life left." --#TYPE "Disk has life left" --#SUMMARY "Adapter %s: Disk (%s) has %s percent life left. Life left thresholds - warning: %s percent, critical: %s percent (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11026 -- EVT_PD_LIFE_NOT_OPTIMAL svrTrapPDLifeNotOptimal TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk life left is below optimal." --#TYPE "Disk life left is below optimal" --#SUMMARY "Adapter %s: Disk (%s) life left (%s percent) is below optimal. Life left thresholds - warning: %s percent, critical: %s percent (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11027 -- EVT_PD_LIFE_CRITICAL svrTrapPDLifeCritical TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk life left is critical." --#TYPE "Disk life left is critical" --#SUMMARY "Adapter %s: Disk (%s) life left (%s percent) is critical. Life left thresholds - warning: %s percent, critical: %s percent (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 6, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11028 -- EVT_PD_FAILURE_LOCKEDUP svrTrapPDFailureLockedup TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk failure device locked-up." --#TYPE "Disk failure device locked-up" --#SUMMARY "Adapter %s: Disk (%s) failure, device locked-up (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11029 -- EVT_CTRL_HOST_DRIVER_UPDATE_NEEDED svrTrapCtrlHostDriverUpdateNeeded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Driver needs to be upgraded." --#TYPE "Driver needs to be upgraded" --#SUMMARY "Adapter %s: Driver needs to be upgraded %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11030 -- EVT_HA_POSSIBLE_PEER_COMM_LOSS svrTrapHAPossiblePeerCommLoss TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Direct communication with peer adapters was not established." --#TYPE "Direct communication with peer adapters was not established" --#SUMMARY "Adapter %s: Direct communication with peer adapter(s) was not established. Please check proper cable connections (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11031 -- EVT_CTRL_FLASH_SIGNED_COMPONENT_NOT_PRESENT svrTrapCtrlFlashSignedComponentNotPresent TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Firmware image does not contain signed component." --#TYPE "Firmware image does not contain signed component" --#SUMMARY "Adapter %s: Firmware image does not contain signed component (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11032 -- EVT_CTRL_FLASH_AUTHENTICATION_FAILURE svrTrapCtrlFlashAuthenticationFailure TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Authentication failure of the signed firmware image." --#TYPE "Authentication failure of the signed firmware image" --#SUMMARY "Adapter %s: Authentication failure of the signed firmware image (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11033 -- EVT_LD_SET_BOOT_DEVICE svrTrapLDSetBootDevice TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Setting logical drive as boot device." --#TYPE "Setting logical drive as boot device" --#SUMMARY "Adapter %s: Setting logical drive %s as boot device (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11034 -- EVT_PD_SET_BOOT_DEVICE svrTrapPDSetBootDevice TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Setting disk as boot device." --#TYPE "Setting disk as boot device" --#SUMMARY "Adapter %s: Setting disk (%s) as boot device (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11035 -- EVT_BBU_TEMPERATURE_CHANGED svrTrapBBUTemperatureChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "The BBU temperature is changed." --#TYPE "The BBU temperature is changed" --#SUMMARY "Adapter %s: The BBU temperature is changed to %s C (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11036 -- EVT_CTRL_TEMPERATURE_CHANGED svrTrapCtrlTemperatureChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "The adapter temperature is changed." --#TYPE "The adapter temperature is changed" --#SUMMARY "Adapter %s: The adapter temperature is changed to %s C (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11037 -- EVT_NVCACHE_BACKUP_UNAVAILABLE svrTrapNVCacheBackupUnavailable TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "FBU capacity is too less to support data backup." --#TYPE "FBU capacity is too less to support data backup" --#SUMMARY "Adapter %s: FBU capacity is too less to support data backup. Write-back logical drives will be converted to Write-through (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11038 -- EVT_NVCACHE_CONSIDER_REPLACEMENT svrTrapNVCacheConsiderReplacement TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "FBU data backup capacity has decreased consider replacement." --#TYPE "FBU data backup capacity has decreased consider replacement" --#SUMMARY "Adapter %s: FBU data backup capacity has decreased, consider replacement (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11039 -- EVT_NVCACHE_INVALID svrTrapNVCacheInvalid TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "FBU device failed." --#TYPE "FBU device failed" --#SUMMARY "Adapter %s: FBU device failed, cannot support data retention (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11040 -- EVT_BOOT_DEVICE_INVALID svrTrapBootDeviceInvalid TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Boot device reset." --#TYPE "Boot device reset" --#SUMMARY "Adapter %s: Boot device reset, setting target ID as invalid (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11041 -- EVT_HA_SSC_WB_POOL_SIZE_MISMATCH svrTrapHASSCWBPoolSizeMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write-back Nytro cache size mismatch between the servers." --#TYPE "Write-back Nytro cache size mismatch between the servers" --#SUMMARY "Adapter %s: Write-back Nytro cache size mismatch between the servers. The Nytro cache size was adjusted to %s GB (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11042 -- EVT_HA_SSC_NONSHARED_VD_WB_ASSOCIATION svrTrapHASSCNonsharedVDWBAssociation TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is not shared between servers but assigned for caching." --#TYPE "Logical drive is not shared between servers but assigned for caching" --#SUMMARY "Adapter %s: Logical drive %s is not shared between servers but assigned for caching. Write-back Nytro cache content of the logical drive will be mirrored (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11043 -- EVT_CTRL_POWER_IO_THROTTLE_START svrTrapCtrlPowerIOThrottleStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power watts usage base IOs throttle started." --#TYPE "Power watts usage base IOs throttle started" --#SUMMARY "Adapter %s: Power %s watts usage base IOs throttle started (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11044 -- EVT_CTRL_POWER_IO_THROTTLE_STOP svrTrapCtrlPowerIOThrottleStop TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Power base IOs throttle stopped." --#TYPE "Power base IOs throttle stopped" --#SUMMARY "Adapter %s: Power base IOs throttle stopped (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11045 -- EVT_CTRL_TUNABLE_PARAMETERS_CHANGED svrTrapCtrlTunableParametersChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter tunable parameters changed." --#TYPE "Adapter tunable parameters changed" --#SUMMARY "Adapter %s: Adapter tunable parameter(s) changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11046 -- EVT_CTRL_TEMP_WITHIN_OPTIMAL_RANGE svrTrapCtrlTempWithinOptimalRange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter operating temperature within normal range." --#TYPE "Adapter operating temperature within normal range" --#SUMMARY "Adapter %s: Adapter operating temperature within normal range, full operation restored (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11047 -- EVT_CTRL_TEMP_ABOVE_OPTIMAL_RANGE svrTrapCtrlTempAboveOptimalRange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Temperature threshold exceeded for the adapter." --#TYPE "Temperature threshold exceeded for the adapter" --#SUMMARY "Adapter %s: Temperature threshold exceeded for the adapter. This may indicate inadequate cooling in the system chassis. Adapter has switched to lower performance mode (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11048 -- EVT_HOST_WARNING_STATUS svrTrapHostWarningStatus TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter defect or no adapter detected on host." --#TYPE "Adapter defect or no adapter detected on host" --#SUMMARY "Adapter defect or no adapter detected on host %s (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11049 -- EVT_HOST_ERROR_STATUS svrTrapHostErrorStatus TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Connection to host failed." --#TYPE "Connection to host failed" --#SUMMARY "Connection to host %s failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11050 -- EVT_HOST_OK_STATUS svrTrapHostOkStatus TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Connection to host established." --#TYPE "Connection to host established" --#SUMMARY "Connection to host %s established (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11051 -- EVT_HA_MODE_HA_FEATURE_SET svrTrapHAModeHAFeatureSet TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter supports high availability mode currently functioning with high availability feature set." --#TYPE "Adapter supports high availability mode currently functioning with high availability feature set" --#SUMMARY "Adapter %s: Adapter supports high availability mode, currently functioning with high availability feature set (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11052 -- EVT_HA_MODE_SC_FEATURE_SET svrTrapHAModeSCFeatureSet TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter supports high availability mode currently functioning with single adapter feature set." --#TYPE "Adapter supports high availability mode currently functioning with single adapter feature set" --#SUMMARY "Adapter %s: Adapter supports high availability mode, currently functioning with single adapter feature set (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11053 -- EVT_NVCACHE_COMPONENT_MISMATCH svrTrapFBUComponentMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "FBU components mismatch." --#TYPE "FBU components mismatch" --#SUMMARY "Adapter %s: FBU components mismatch. Write-back logical drives will be converted to write-through (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11054 -- EVT_CTRL_ENTER_MAINTENANCE_MODE svrTrapCtrlEnterMaintenanceMode TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter has entered maintenance mode." --#TYPE "Adapter has entered maintenance mode" --#SUMMARY "Adapter %s: Adapter has entered maintenance mode (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11055 -- EVT_CTRL_EXIT_MAINTENANCE_MODE svrTrapCtrlExitMaintenanceMode TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter has returned to normal mode." --#TYPE "Adapter has returned to normal mode" --#SUMMARY "Adapter %s: Adapter has returned to normal mode (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11056 -- EVT_HA_TOPOLOGY_MODE svrTrapHATopologyMode TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Topology is in mode." --#TYPE "Topology is in mode" --#SUMMARY "Adapter %s: Topology is in %s mode (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11057 -- EVT_HA_TOPOLOGY_LD_INCOMPATIBLE svrTrapHATopologyLDIncompatible TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cannot enter mode because logical drive would not be supported." --#TYPE "Cannot enter mode because logical drive would not be supported" --#SUMMARY "Adapter %s: Cannot enter %s mode because %s logical drive %s would not be supported (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11058 -- EVT_HA_TOPOLOGY_PD_INCOMPATIBLE svrTrapHATopologyPDIncompatible TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cannot enter mode because disk would not be supported." --#TYPE "Cannot enter mode because disk would not be supported" --#SUMMARY "Adapter %s: Cannot enter %s mode because %s disk (%s) would not be supported (Server %s)" --#ARGUMENTS { 2, 3, 4, 5, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11059 -- EVT_HOST_DELETED svrTrapHostDeleted TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Connection to host deleted." --#TYPE "Connection to host deleted" --#SUMMARY "Connection to host %s deleted (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11060 -- EVT_HOST_MODIFIED svrTrapHostModified TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Connection to host modified." --#TYPE "Connection to host modified" --#SUMMARY "Connection to host %s modified (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11061 -- EVT_BBU_BAD_EXPECTED svrTrapBBUBadExpected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "BBU relearn requires to change WriteBack logical drives to WriteThrough." --#TYPE "BBU relearn requires to change WriteBack logical drives to WriteThrough" --#SUMMARY "Adapter %s: BBU relearn requires to change WriteBack logical drives to WriteThrough (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11062 -- EVT_ALARM_SILENCED svrTrapAlarmSilenced TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Alarm silenced." --#TYPE "Alarm silenced" --#SUMMARY "Adapter %s: Alarm silenced (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11063 -- EVT_CTRL_CACHE_FLUSH_START svrTrapCtrlCacheFlushStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache flush started." --#TYPE "Cache flush started" --#SUMMARY "Adapter %s: %s cache flush started (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11064 -- EVT_CTRL_CACHE_FLUSH_DONE svrTrapCtrlCacheFlushDone TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache flush finished." --#TYPE "Cache flush finished" --#SUMMARY "Adapter %s: %s cache flush finished (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11065 -- EVT_CTRL_CACHE_FLUSH_ABORT svrTrapCtrlCacheFlushAbort TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Cache flush aborted by user." --#TYPE "Cache flush aborted by user" --#SUMMARY "Adapter %s: %s cache flush aborted by user (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11066 -- EVT_CTRL_PERSONALITY_CHANGE svrTrapCtrlPersonalityChange TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter personality changed." --#TYPE "Adapter personality changed" --#SUMMARY "Adapter %s: Adapter personality changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11067 -- EVT_CFG_AUTO_CREATED svrTrapCfgAutoCreated TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Configuration automatically created." --#TYPE "Configuration automatically created" --#SUMMARY "Adapter %s: Configuration automatically created by %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11068 -- EVT_CTRL_SWZONE_ENABLED svrTrapCtrlSwZoneEnabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Software zone enabled." --#TYPE "Software zone enabled" --#SUMMARY "Adapter %s: Software zone enabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11069 -- EVT_CTRL_SWZONE_DISABLED svrTrapCtrlSwZoneDisabled TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Software zone disabled." --#TYPE "Software zone disabled" --#SUMMARY "Adapter %s: Software zone disabled (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11070 -- EVT_LD_INIT_ABORTED_DUE_TO_RESET svrTrapLDInitAbortedDueToReset TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Initialization aborted on logical drive due to adapter reset." --#TYPE "Initialization aborted on logical drive due to adapter reset" --#SUMMARY "Adapter %s: Initialization aborted on logical drive %s due to adapter reset (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11071 -- EVT_HA_CTRL_LOCK_KEY_MISMATCH svrTrapHACtrlLockKeyMismatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Peer adapter security key mismatch." --#TYPE "Peer adapter security key mismatch" --#SUMMARY "Adapter %s: Peer adapter security key mismatch (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11072 -- EVT_HA_CTRL_LOCK_KEY_MATCH svrTrapHACtrlLockKeyMatch TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Peer adapter security key match." --#TYPE "Peer adapter security key match" --#SUMMARY "Adapter %s: Peer adapter security key match (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11073 -- EVT_HA_LD_COMPATIBLE svrTrapHALDCompatible TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive is now compatible in the high availability domain." --#TYPE "Logical drive is now compatible in the high availability domain" --#SUMMARY "Adapter %s: Logical drive %s is now compatible in the high availability domain (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11074 -- EVT_PD_OPERATION_DELAYED svrTrapPDOperationDelayed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk operation delayed." --#TYPE "Disk operation delayed" --#SUMMARY "Adapter %s: Disk (%s) operation delayed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11075 -- EVT_LD_OPERATION_DELAYED svrTrapLDOperationDelayed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive operation delayed." --#TYPE "Logical drive operation delayed" --#SUMMARY "Adapter %s: Logical drive %s operation delayed (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11076 -- EVT_CTRL_GENERIC_MESSAGE svrTrapCtrlGenericMessage TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Message." --#TYPE "Message" --#SUMMARY "Adapter %s: Message: %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11077 -- EVT_LD_VF_MAP svrTrapLDVFMap TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Virtual function map." --#TYPE "Virtual function map" --#SUMMARY "Adapter %s: Virtual function map: %s (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11078 -- EVT_CTRL_TEMP_CRITICAL svrTrapCtrlTempCritical TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Solution will shut down due to maximum temperature threshold exception." --#TYPE "Solution will shut down due to maximum temperature threshold exception" --#SUMMARY "Adapter %s: Solution will shut down due to maximum temperature threshold exception. This may indicate inadequate system cooling (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY CRITICAL --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE NONOPERATIONAL ::= 11079 -- EVT_CTRL_CHASSIS_SHUTDOWN svrTrapCtrlChassisShutdown TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Shutdown chassis command received from host." --#TYPE "Shutdown chassis command received from host" --#SUMMARY "Adapter %s: Shutdown chassis command received from host (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11080 -- EVT_CTRL_CHASSIS_RESTART svrTrapCtrlChassisRestart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Restart chassis command received from host." --#TYPE "Restart chassis command received from host" --#SUMMARY "Adapter %s: Restart chassis command received from host (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11081 -- EVT_CTRL_INFO_CHANGED svrTrapCtrlInfoChanged TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter information changed." --#TYPE "Adapter information changed" --#SUMMARY "Adapter %s: Adapter information changed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11082 -- EVT_LD_PARTIALLY_HIDDEN svrTrapLDPartiallyHidden TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Hidden policy not set for all logical drives in the array." --#TYPE "Hidden policy not set for all logical drives in the array" --#SUMMARY "Adapter %s: Hidden policy not set for all logical drives in the array (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11083 -- EVT_PD_NOT_ENTERPRISE_SELF_ENCRYPTING_DRIVE svrTrapPDNotEnterpriseSelfEncryptingDrive TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk is not an enterprise class self encrypting disk." --#TYPE "Disk is not an enterprise class self encrypting disk" --#SUMMARY "Adapter %s: Disk (%s) is not an enterprise class self encrypting disk. Encryption capability of the drive will be disabled (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11084 -- EVT_CTRL_FORCE_FLASH svrTrapCtrlForceFlash TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter firmware was updated with force option." --#TYPE "Adapter firmware was updated with force option" --#SUMMARY "Adapter %s: Adapter firmware was updated with force option (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11085 -- EVT_CTRL_WRITE_REG_POWER svrTrapCtrlWriteRegPower TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Write regulation activated due to power constraints of PCI slot." --#TYPE "Write regulation activated due to power constraints of PCI slot" --#SUMMARY "Adapter %s: Write regulation activated due to power constraints of PCI slot (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11086 -- EVT_CTRL_UNACTIVATED_FIRMWARE svrTrapCtrlUnactivatedFirmware TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Unactivated firmware available." --#TYPE "Unactivated firmware available" --#SUMMARY "Adapter %s: Unactivated firmware available (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11087 -- EVT_CTRL_RELIABILITY_DEGRADED svrTrapCtrlReliabilityDegraded TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reliability degraded." --#TYPE "Reliability degraded" --#SUMMARY "Adapter %s: Reliability degraded (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11088 -- EVT_PD_ESTIMATED_LIFETIME_BELOW_THRESHOLD svrTrapPDEstimatedLifetimeBelowThreshold TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Estimated lifetime of disk below 60 days." --#TYPE "Estimated lifetime of disk below 60 days" --#SUMMARY "Adapter %s: Estimated lifetime of disk (%s) below 60 days (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Backup your data. 2) Replace affected disk as soon as possible." --#STATE OPERATIONAL ::= 11089 -- EVT_PD_WEAR_LEVEL_COUNT_ABOVE_THRESHOLD svrTrapPDWearLevelCountAboveThreshold TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Wear level count of disk above threshold." --#TYPE "Wear level count of disk above threshold" --#SUMMARY "Adapter %s: Wear level count of disk (%s) above threshold (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Backup your data. 2) Replace affected disk as soon as possible to avoid malfunction (read only mode)." --#STATE OPERATIONAL ::= 11090 -- EVT_PD_RESERVED_CELLS_BELOW_THRESHOLD svrTrapPDReservedCellsBelowThreshold TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Reserve space of disk below threshold." --#TYPE "Reserve space of disk below threshold" --#SUMMARY "Adapter %s: Reserve space of disk (%s) below threshold (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "1) Backup your data. 2) Replace affected disk as soon as possible to avoid malfunction (read only mode)." --#STATE OPERATIONAL ::= 11091 -- EVT_PD_AVERAGE_USAGE_ABOVE_SPECIFICATION svrTrapPDAverageUsageAboveSpecification TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Average write usage of disk above specification." --#TYPE "Average write usage of disk above specification" --#SUMMARY "Adapter %s: Average write usage of disk (%s) above specification (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Decrease amount of write accesses to the disk." --#STATE OPERATIONAL ::= 11092 -- EVT_CTRL_PNPADD svrTrapNewCtrlDetected TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "New adapter detected." --#TYPE "New adapter detected" --#SUMMARY "Adapter %s: New adapter detected (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11093 -- EVT_CTRL_PNPREMOVE svrTrapCtrlRemoved TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Adapter removed." --#TYPE "Adapter removed" --#SUMMARY "Adapter %s: Adapter removed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Note: Only informational if adapter was removed by user." --#STATE OPERATIONAL ::= 11094 -- EVT_LD_ACCESS_POLICY_SET_TO_RW svrTrapLDAccessPolicySetToRW TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Logical drive default access policy is set to read/write mode." --#TYPE "Logical drive default access policy is set to read/write mode" --#SUMMARY "Adapter %s: Logical drive %s default access policy is set to read/write mode (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11095 -- EVT_CTRL_FLASH_TRANSIENT_ERROR svrTrapCtrlFlashTransientError TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disabling writes to flash due to a critical error." --#TYPE "Disabling writes to flash due to a critical error" --#SUMMARY "Adapter %s: Disabling writes to flash due to a critical error. Reboot the system to enable writes to flash again (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11096 -- EVT_CTRL_FLASH_FAILED svrTrapCtrlFlashFailed TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disabling writes to flash as the part has failed." --#TYPE "Disabling writes to flash as the part has failed" --#SUMMARY "Adapter %s: Disabling writes to flash as the part has failed (Server %s)" --#ARGUMENTS { 2, 0 } --#SEVERITY MAJOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11097 -- EVT_PD_LOCATE_START svrTrapPDLocateStart TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Locate LED started on disk." --#TYPE "Locate LED started on disk" --#SUMMARY "Adapter %s: Locate LED started on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11098 -- EVT_PD_LOCATE_STOP svrTrapPDLocateStop TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Locate LED stopped on disk." --#TYPE "Locate LED stopped on disk" --#SUMMARY "Adapter %s: Locate LED stopped on disk (%s) (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11099 -- EVT_PD_PR_CONFLICT_ABORT svrTrapPDPRConflictAbort TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Patrol read aborted on disk due to conflict with other background operations." --#TYPE "Patrol read aborted on disk due to conflict with other background operations" --#SUMMARY "Adapter %s: Patrol read aborted on disk (%s) due to conflict with other background operations (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "For information only." --#STATE OPERATIONAL ::= 11100 -- EVT_PD_DEGRADED_MEDIA svrTrapPDDegradedMedia TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk has bad media events." --#TYPE "Disk has bad media events" --#SUMMARY "Adapter %s: Disk (%s) has bad media events (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY INFORMATIONAL --#TIMEINDEX 1 --#HELP "" --#STATE OPERATIONAL ::= 11101 -- EVT_PD_DEGRADED_MEDIA_POOR_PERFORMANCE svrTrapPDDegradedMediaPoorPerformance TRAP-TYPE ENTERPRISE svrNotifications VARIABLES { svrTrapInfoServerName, svrTrapInfoTime, svrTrapInfoPlaceHolder1, svrTrapInfoPlaceHolder2, svrTrapInfoPlaceHolder3, svrTrapInfoPlaceHolder4, svrTrapInfoPlaceHolder5, svrTrapInfoPlaceHolder6 } DESCRIPTION "Disk has bad performance due to bad media events." --#TYPE "Disk has bad performance due to bad media events" --#SUMMARY "Adapter %s: Disk (%s) has bad performance due to bad media events (Server %s)" --#ARGUMENTS { 2, 3, 0 } --#SEVERITY MINOR --#TIMEINDEX 1 --#HELP "Call your local Fujitsu Helpdesk." --#STATE OPERATIONAL ::= 11102 END